“Micro to nano : multiscale IR analyses reveal zinc soap heterogeneity in a 19th-century painting by Corot”. Ma X, Pavlidis G, Dillon E, Beltran V, Schwartz JJ, Thoury M, Borondics F, Sandt C, Kjoller K, Berrie BH, Centrone A, Analytical chemistry 94, 3103 (2022). http://doi.org/10.1021/ACS.ANALCHEM.1C04182
Abstract: Formation and aggregation of metal carboxylates (metal soaps) can degrade the appearance and integrity of oil paints, challenging efforts to conserve painted works of art. Endeavors to understand the root cause of metal soap formation have been hampered by the limited spatial resolution of Fourier transform infrared microscopy (mu-FTIR). We overcome this limitation using optical photothermal infrared spectroscopy (O-PTIR) and photothermal-induced resonance (PTIR), two novel methods that provide IR spectra with approximate to 500 and approximate to 10 nm spatial resolutions, respectively. The distribution of chemical phases in thin sections from the top layer of a 19th-century painting is investigated at multiple scales (mu-FTIR approximate to 10(2) mu m(3), O-PTIR approximate to 10(-1) mu m(3), PTIR approximate to 10(-5) mu m(3)). The paint samples analyzed here are found to be mixtures of pigments (cobalt green, lead white), cured oil, and a rich array of intermixed, small (often << 0.1 mu m(3)) zinc soap domains. We identify Zn stearate and Zn oleate crystalline soaps with characteristic narrow IR peaks (approximate to 1530-1558 cm(-1)) and a heterogeneous, disordered, water-permeable, tetrahedral zinc soap phase, with a characteristic broad peak centered at approximate to 1596 cm(-1). We show that the high signal-to-noise ratio and spatial resolution afforded by O-PTIR are ideal for identifying phase-separated (or locally concentrated) species with low average concentration, while PTIR provides an unprecedented nanoscale view of distributions and associations of species in paint. This newly accessible nanocompositional information will advance our knowledge of chemical processes in oil paint and will stimulate new art conservation practices.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1021/ACS.ANALCHEM.1C04182
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 76, 3313 (2004). http://doi.org/10.1021/ac040052x
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 32
DOI: 10.1021/ac040052x
|
|
|
“Thin-layer potentiometry for creatinine detection in undiluted human urine using ion-exchange membranes as barriers for charged interferences”. Liu Y, Cánovas R, Crespo GA, Cuartero M, Analytical Chemistry 92, 3315 (2020). http://doi.org/10.1021/ACS.ANALCHEM.9B05231
Abstract: Herein, thin-layer potentiometry combined with ion-exchange membranes as barriers for charged interferences is demonstrated for the analytical detection of creatinine (CRE) in undiluted human urine. Briefly, CRE diffuses through an anion-exchange membrane (AEM) from a sample contained in one fluidic compartment to a second reservoir, containing the enzyme CRE deiminase. There, CRE reacts with the enzyme, and the formation of ammonium is dynamically monitored by potentiometric ammonium-selective electrodes. This analytical concept is integrated into a lab-on-a-chip microfluidic cell that allows for a high sample throughput and the operation under stop-flow mode, which allows CRE to passively diffuse across the AEM. Conveniently, positively charged species (i.e., potassium, sodium, and ammonium, among others) are repelled by the AEM and never reach the ammonium-selective electrodes; thus, possible interference in the response can be avoided. As a result, the dynamic potential response of the electrodes is entirely ascribed to the stoichiometric formation of ammonium. The new CRE biosensor exhibits a Nernstian slope, within a linear range of response from 1 to 50 mM CRE concentration. As expected, the response time (15–60 min) primarily depends on the CRE diffusion across the AEM. CRE analysis in urine samples displayed excellent results, without requiring sample pretreatment (before the introduction of the sample in the microfluidic chip) and with high compatibility with development into a potential point-of-care clinical tool. In an attempt to decrease the analysis time, the presented analytical methodology for CRE detection is translated into an all-solid-state platform, in which the enzyme is immobilized on the surface of the ammonium-selective electrode and with the AEM on top. While more work is necessary in this direction, the CRE sensor appears to be promising for CRE analysis in both urine and blood.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.9B05231
|
|
|
“Unique opto-electronic structure and photo reduction properties of sulfur doped lead chromates explaining their instability in paintings”. Rahemi V, Sarmadian N, Anaf W, Janssens K, Lamoen D, Partoens B, De Wael K, Analytical chemistry 89, 3326 (2017). http://doi.org/10.1021/ACS.ANALCHEM.6B03803
Abstract: Chrome yellow refers to a group of synthetic inorganic pigments that became popular as an artists material from the second quarter of the 19th century. The color of the pigment, in which the chromate ion acts as a chromophore, is related to its chemical composition (PbCr1-xSxO4, with 0≤x≤0.8) and crystalline structure (monoclinic/orthorhombic). Their shades range from the yellow-orange to the paler yellow tones with increasing sulfate amount. These pigments show remarkable signs of degradation after limited time periods. Pure PbCrO4 (crocoite in its natural form) has a deep yellow color and is relatively stable, while the co-precipitate with lead sulfate (PbCr1-xSxO4) has a paler shade and seems to degrade faster. This degradation is assumed to be related to the reduction of Cr(VI) to Cr(III). We show that on increasing the sulfur(S)-content in chrome yellow, the band gap increases. Typically, when increasing the band gap, one might assume that a decrease in photo activity is the result. However, the photo activity relative to the Cr content, and thus Cr reduction, of sulfur-rich PbCr1-xSxO4 is found to be much higher compared to the sulfur-poor or non-doped lead chromates. This discrepancy can be explained by the evolution of the crystal and electronic structure as function of the sulfur content: first-principles density functional theory calculations show that both the absorption coefficient and reflection coefficients of the lead chromates change as a result of the sulfate doping in such a way that the generation of electron-hole pairs under illumination relative to the total Cr content increases. These changes in the material properties explain why paler shade yellow colors of this pigment are more prone to discoloration. The electronic structure calculations also demonstrate that lead chromate and its co-precipitates are p-type semiconductors, which explains the observed reduction reaction. As understanding this phenomenon is valuable in the field of cultural heritage, this study is the first joint action of photo-electrochemical measurements and first-principles calculations to approve the higher tendency of sulfur-rich lead chromates to darken.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 7
DOI: 10.1021/ACS.ANALCHEM.6B03803
|
|
|
“Spatially resolved (semi)quantitative determination of iron (Fe) in plants by means of synchrotron micro X-ray fluorescence”. Terzano R, Alfeld M, Janssens K, Vekemans B, Schoonjans T, Vincze L, Tomasi N, Pinton R, Cesco S, Analytical and bioanalytical chemistry 405, 3341 (2013). http://doi.org/10.1007/S00216-013-6768-6
Abstract: Iron (Fe) is an essential element for plant growth and development; hence determining Fe distribution and concentration inside plant organs at the microscopic level is of great relevance to better understand its metabolism and bioavailability through the food chain. Among the available microanalytical techniques, synchrotron mu-XRF methods can provide a powerful and versatile array of analytical tools to study Fe distribution within plant samples. In the last years, the implementation of new algorithms and detection technologies has opened the way to more accurate (semi)quantitative analyses of complex matrices like plant materials. In this paper, for the first time the distribution of Fe within tomato roots has been imaged and quantified by means of confocal mu-XRF and exploiting a recently developed fundamental parameter-based algorithm. With this approach, Fe concentrations ranging from few hundreds of ppb to several hundreds of ppm can be determined at the microscopic level without cutting sections. Furthermore, Fe (semi)quantitative distribution maps were obtained for the first time by using two opposing detectors to collect simultaneously the XRF radiation emerging from both sides of an intact cucumber leaf.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 27
DOI: 10.1007/S00216-013-6768-6
|
|
|
“Assessing the molecular weight of a conducting polymer by grazing emission XRF”. Blockhuys F, Claes M, Van Grieken R, Geise HJ, Analytical chemistry 72, 3366 (2000). http://doi.org/10.1021/AC990877K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990877K
|
|
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 76, 3445 (2004). http://doi.org/10.1021/AC0400820
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC0400820
|
|
|
“Direct current glow discharge mass spectrometric analysis of Macor ceramic using a secondary cathode”. Schelles W, Van Grieken R, Analytical chemistry 68, 3570 (1996). http://doi.org/10.1021/AC960441U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC960441U
|
|
|
“Amperometric flow-injection analysis of phenols induced by reactive oxygen species generated under daylight irradiation of titania impregnated with horseradish peroxidase”. Rahemi V, Trashin S, Hafideddine Z, Van Doorslaer S, Meynen V, Gorton L, De Wael K, Analytical Chemistry 92, 3643 (2020). http://doi.org/10.1021/acs.analchem.9b04617
Abstract: Titanium dioxide (TiO2) is a unique material for biosensing applications due to its capability of hosting enzymes. For the first time, we show that TiO2 can accumulate reactive oxygen species (ROS) under daylight irradiation and can support the catalytic cycle of horseradish peroxidase (HRP) without the need of H2O2 to be present in the solution. Phenolic compounds, such as hydroquinone (HQ) and 4-aminophenol (4-AP), were detected amperometrically in flow-injection analysis (FIA) mode via the use of an electrode modified with TiO2 impregnated with HRP. In contrast to the conventional detection scheme, no H2O2 was added to the analyte solution. Basically, the inherited ability of TiO2 to generate reactive oxygen species is used as a strategy to avoid adding H2O2 in the solution during the detection of phenolic compounds. Electron paramagnetic resonance (EPR) spectroscopy indicates the presence of ROS on titania which, in interaction with HRP, initiate the electrocatalysis toward phenolic compounds. The amperometric response to 4-AP was linear in the concentration range between 0.05 and 2 μM. The sensitivity was 0.51 A M–1 cm–2, and the limit of detection (LOD) 26 nM. The proposed sensor design opens new opportunities for the detection of phenolic traces by HRP-based electrochemical biosensors, yet in a more straightforward and sensitive way following green chemistry principles of avoiding the use of reactive and harmful chemical, such as H2O2.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
Times cited: 3
DOI: 10.1021/acs.analchem.9b04617
|
|
|
“Three-dimensional chemical characterization of complex silver halide microcrystals by scanning ion microprobe mass analysis”. Verlinden G, Janssens G, Gijbels R, van Espen P, Geuens I, Analytical chemistry 69, 3773 (1997). http://doi.org/10.1021/ac970010r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 6
DOI: 10.1021/ac970010r
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 78, 3917 (2006). http://doi.org/10.1021/ac060597m
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 112
DOI: 10.1021/ac060597m
|
|
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 78, 4069 (2006). http://doi.org/10.1021/AC060688J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC060688J
|
|
|
“Interface for reproducible, multishot direct analysis of solid-phase microextraction samples”. Newsome GA, Kavich G, Alvarez-Martin A, Analytical Chemistry 92, 4182 (2020). http://doi.org/10.1021/ACS.ANALCHEM.9B05691
Abstract: An enclosed interface that joins a direct analysis in real time (DART) probe, solid-phase microextraction (SPME) fiber, and the inlet of a high-resolution mass spectrometer is described. Unlike other systems to couple SPME sampling to ambient mass spectrometry, the interface is able to perform discrete analyses on different areas of a single SPME fiber device for up to three technical replicate measurements of one sampling event. Inlet flow speed and desorption temperature are optimized, and reproducibility is demonstrated between replicate analyses on the same derivatized SPME fiber and with sequential fiber sampling events, yielding analyte measurement center of variance (CV) from 3 to 6%. Conditioning is also performed with the enclosed DART. The interface is a straightforward addition to commercially available technologies, and machine diagrams for custom components operated with SPME/DART/MS equipment are included.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.9B05691
|
|
|
“Optimized transport setup for high repetition rate pulse-separated analysis in laser ablation-inductively coupled plasma mass spectrometry”. Lindner H, Autrique D, Garcia CC, Niemax K, Bogaerts A, Analytical chemistry 81, 4241 (2009). http://doi.org/10.1021/ac802627x
Abstract: An optimized laser ablation setup, proposed for high repetition rate inductively coupled plasma mass spectrometry (ICPMS) analyses such as 2D imaging or depth profiling, is presented. For such applications, the particle washout time needs to be as short as possible to allow high laser pulse frequencies for reduced analysis time. Therefore, it is desirable to have an ablation setup that operates as a laminar flow reactor (LFR). A top-down strategy was applied that resulted in the present design. In the first step, a previously applied ablation setup was analyzed on the basis of computational fluid dynamics (CFD) results presented by D. Autrique et al. (Spectrochim. Acta, B 2008, 63, 257−270). By means of CFD simulations, the design was modified in such a way that it operated in the LFR regime. Experimental results demonstrate that the current design can indeed be regarded as an LFR. Furthermore, the operation under LFR conditions allowed some insight into the initial radial concentration distribution if the experimental ICPMS signal and analytical expressions are taken into account. Recommendations for a modified setup for more resilient spatial distributions are given. With the present setup, a washout time of 140 ms has been achieved for a 3% signal area criterion. Therefore, 7 Hz repetition rates can be applied with the present setup. Using elementary formulas of the analytical model, an upper bound for the washout times for similar setups can be predicted. The authors believe that the presented setup geometry comes close to the achievable limit for reliable short washout times.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 18
DOI: 10.1021/ac802627x
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 80, 4317 (2008). http://doi.org/10.1021/ac8006297
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 53
DOI: 10.1021/ac8006297
|
|
|
“Heterogeneity assessment in individual CaCO3-CaSO4 particles using ultrathin window electron probe X-ray microanalysis”. Ro C-U, Oh K-Y, Osán J, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 73, 4574 (2001). http://doi.org/10.1021/AC010438X
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC010438X
|
|
|
“Atomic spectroscopy: a review”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 82, 4653 (2010). http://doi.org/10.1021/ac1010469
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 65
DOI: 10.1021/ac1010469
|
|
|
“Unraveling the effect of the aptamer complementary element on the performance of duplexed aptamers : a thermodynamic study”. Dillen A, Vandezande W, Daems D, Lammertyn J, Analytical And Bioanalytical Chemistry 413, 4739 (2021). http://doi.org/10.1007/S00216-021-03444-Y
Abstract: Duplexed aptamers (DAs) are widespread aptasensor formats that simultaneously recognize and signal the concentration of target molecules. They are composed of an aptamer and aptamer complementary element (ACE) which consists of a short oligonucleotide that partially inhibits the aptamer sequence. Although the design principles to engineer DAs are straightforward, the tailored development of DAs for a particular target is currently based on trial and error due to limited knowledge of how the ACE sequence affects the final performance of DA biosensors. Therefore, we have established a thermodynamic model describing the influence of the ACE on the performance of DAs applied in equilibrium assays and demonstrated that this relationship can be described by the binding strength between the aptamer and ACE. To validate our theoretical findings, the model was applied to the 29-mer anti-thrombin aptamer as a case study, and an experimental relation between the aptamer-ACE binding strength and performance of DAs was established. The obtained results indicated that our proposed model could accurately describe the effect of the ACE sequence on the performance of the established DAs for thrombin detection, applied for equilibrium assays. Furthermore, to characterize the binding strength between the aptamer and ACEs evaluated in this work, a set of fitting equations was derived which enables thermodynamic characterization of DNA-based interactions through thermal denaturation experiments, thereby overcoming the limitations of current predictive software and chemical denaturation experiments. Altogether, this work encourages the development, characterization, and use of DAs in the field of biosensing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
DOI: 10.1007/S00216-021-03444-Y
|
|
|
“The use of potentiometric sensors to study (bio)molecular interactions”. De Wael K, Daems D, Van Camp G, Nagels LJ, Analytical chemistry 84, 4921 (2012). http://doi.org/10.1021/AC3005428
Abstract: Potentiometric sensors were used to study molecular interactions in liquid environments, with sensorgram methodology. This is demonstrated with a lipophilic rubber-, and with a collagen based hydrogel sensor coating. The investigated molecules were promazine and tartaric acid respectively. The sensors were placed in a hydrodynamic wall jet system for the recording of sensorgrams. mV sensor responses were first converted to a signal, expressing the concentration of adsorbed organic ions. Using a linearization method, a pseudo first order kinetic model of adsorption was shown to fit the experimental results perfectly. Kass, kon and koff values were calculated.. The technique can be used over 4 decades of concentration, and it is very sensitive to low MW compounds as well as to multiply charged large biomolecules. This study is the first to demonstrate the application of potentiometric sensors as an alternative and complement to SPR methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 10
DOI: 10.1021/AC3005428
|
|
|
“A Monte Carlo model for studying the microheterogeneity of trace elements in reference materials by means of synchrotron microscopic X-ray fluorescence”. Kempenaers L, Janssens K, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Simionovici AS, Adams F, Analytical chemistry 74, 5017 (2002). http://doi.org/10.1021/AC025662G
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 21
DOI: 10.1021/AC025662G
|
|
|
“Grazing-exit particle-induced X-ray emission analysis with extremely low background”. Tsuji K, Spolnik Z, Wagatsuma K, Van Grieken RE, Vis RD, Analytical chemistry 71, 5033 (1999). http://doi.org/10.1021/AC990568U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990568U
|
|
|
“Correlation between the fluorination degree of perfluorinated zinc phthalocyanines, their singlet oxygen generation ability, and their photoelectrochemical response for phenol sensing”. Neven L, Barich H, Ching HYV, Khan SU, Colomier C, Patel HH, Gorun SM, Verbruggen S, Van Doorslaer S, De Wael K, Analytical chemistry 94, 5221 (2022). http://doi.org/10.1021/ACS.ANALCHEM.1C04357
Abstract: Electron-withdrawing perfluoroalkyl peripheral groups grafted on phthalocyanine (Pc) macrocycles improve their single-site isolation, solubility, and resistance to self-oxidation, all beneficial features for catalytic applications. A high degree of fluorination also enhances the reducibility of Pcs and could alter their singlet oxygen (1O2) photoproduction. The ethanol/toluene 20:80 vol % solvent mixture was found to dissolve perfluorinated FnPcZn complexes, n = 16, 52, and 64, and minimize the aggregation of the sterically unencumbered F16PcZn. The 1O2 production ability of FnPcZn complexes was examined using 9,10-dimethylanthracene (DMA) and 2,2,6,6-tetramethylpiperidine (TEMP) in combination with UV–vis and electron paramagnetic resonance (EPR) spectroscopy, respectively. While the photoreduction of F52PcZn and F64PcZn in the presence of redox-active TEMP lowered 1O2 production, DMA was a suitable 1O2 trap for ranking the complexes. The solution reactivity was complemented by solid-state studies via the construction of photoelectrochemical sensors based on TiO2-supported FnPcZn, FnPcZn|TiO2. Phenol photo-oxidation by 1O2, followed by its electrochemical reduction, defines a redox cycle, the 1O2 production having been found to depend on the value of n and structural features of the supported complexes. Consistent with solution studies, F52PcZn was found to be the most efficient 1O2 generator. The insights on reactivity testing and structural–activity relationships obtained may be useful for designing efficient and robust sensors and for other 1O2-related applications of FnPcZn.
Keywords: A1 Journal article; Organic synthesis (ORSY); Sustainable Energy, Air and Water Technology (DuEL); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.1C04357
|
|
|
“Levamisole : a common adulterant in cocaine street samples hindering electrochemical detection of cocaine”. De Jong M, Florea A, de Vries A-M, van Nuijs ALN, Covaci A, Van Durme F, Martins JC, Samyn N, De Wael K, Analytical chemistry 90, 5290 (2018). http://doi.org/10.1021/ACS.ANALCHEM.8B00204
Abstract: The present work investigates the electrochemical determination of cocaine in the presence of levamisole, one of the most common adulterants found in cocaine street samples. Levamisole misleads cocaine color tests, giving a blue color (positive test) even in the absence of cocaine. Moreover, the electrochemical detection of cocaine is also affected by the presence of levamisole, with a suppression of the oxidation signal of cocaine. When levamisole is present in the sample in ratios higher than 1:1, the cocaine signal is no longer detected, thus leading to false negative results. Mass spectrometry and nuclear magnetic resonance were used to investigate if the signal suppression is due to the formation of a complex between cocaine and levamisole in bulk solution. Strategies to eliminate this suppressing effect are further suggested in this manuscript. In a first approach, the increase of the pH of the sample solution from pH 7 to pH 12 allowed the voltammetric determination of cocaine in the presence of levamisole in a concentration range from 10 to 5000 μM at nonmodified graphite disposable electrodes with a detection limit of 5 μM. In a second approach, the graphite electrode was cathodically pretreated, resulting in the presence of oxidation peaks of both cocaine and levamisole, with a detection limit for cocaine of 3 μM over the linear range of concentrations from 10 to 2500 μM. Both these strategies have been successfully applied for the simultaneous detection of cocaine and levamisole in three street samples on unmodified graphite disposable electrodes.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 6.32
Times cited: 8
DOI: 10.1021/ACS.ANALCHEM.8B00204
|
|
|
“Direct sensing of superoxide and its relatives reactive oxygen and nitrogen species in phosphate buffers during cold atmospheric plasmas exposures”. Girard-Sahun F, Lefrancois P, Badets V, Arbault S, Clement F, Analytical Chemistry 94, 5555 (2022). http://doi.org/10.1021/ACS.ANALCHEM.1C04998
Abstract: This study aims at sensing in situ reactive oxygen and nitrogen species (RONS) and specifically superoxide anion (O-2(center dot-)) in aqueous buffer solutions exposed to cold atmospheric plasmas (CAPs). CAPs were generated by ionizing He gas shielded with variable N-2/O-2 mixtures. Thanks to ultramicroelectrodes protected against the high electric fields transported by the ionization waves of CAPs, the production of superoxide and several RONS was electrochemically directly detected in liquids during their plasma exposure. Complementarily, optical emissive spectroscopy (OES) was used to study the plasma phase composition and its correlation with the chemistry in the exposed liquid. The specific production of O-2(center dot-), a biologically reactive redox species, was analyzed by cyclic voltammetry (CV), in both alkaline (pH 11), where the species is fairly stable, and physiological (pH 7.4) conditions, where it is unstable. To understand its generation with respect to the plasma chemistry, we varied the shielding gas composition of CAPs to directly impact on the RONS composition at the plasma-liquid interface. We observed that the production and accumulation of RONS in liquids, including O(2)(center dot-)depends on the plasma composition, with N-2-based shieldings providing the highest superoxide concentrations (few 10s of micromolar at most) and of its derivatives (hundreds of micromolar). In situ spectroscopic and electrochemical analyses provide a high resolution kinetic and quantitative understanding of the interactions between CAPs and physiological solutions for biomedical applications.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.1C04998
|
|
|
“Quantitative determination of low-Z elements in single atmospheric particles on boron substrates by automated scanning electron microscopy: energy-dispersive X-ray spectrometry”. Choël M, Deboudt K, Osán J, Flament P, Van Grieken R, Analytical chemistry 77, 5686 (2005). http://doi.org/10.1021/AC050739X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC050739X
|
|
|
“Modeling plasmas in analytical chemistry—an example of cross-fertilization”. Bogaerts A, Analytical And Bioanalytical Chemistry 412, 6059 (2020). http://doi.org/10.1007/s00216-020-02587-8
Abstract: This paper gives an overview of the modeling work developed in our group in the last 25 years for various plasmas used in analytical spectrochemistry, i.e., glow discharges (GDs), inductively coupled plasmas (ICPs), and laser ablation (LA) for sample introduction in the ICP and for laser-induced breakdown spectroscopy (LIBS). The modeling approaches are briefly presented, which are different for each case, and some characteristic results are illustrated. These plasmas are used not only in analytical chemistry but also in other applications, and the insights obtained in these other fields were quite helpful for us to develop models for the analytical plasmas. Likewise, there is now a huge interest in plasma–liquid interaction, atmospheric pressure glow discharges (APGDs), and dielectric barrier discharges (DBDs) for environmental, medical, and materials applications of plasmas. The insights obtained in these fields are also very relevant for ambient desorption/ionization sources and for liquid sampling, which are nowadays very popular in analytical chemistry, and they could be very helpful in developing models for these sources as well.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.3
DOI: 10.1007/s00216-020-02587-8
|
|
|
“Determination of platinum, palladium, and rhodium in automotive catalysts using high-energy secondary target X-ray fluorescence spectrometry”. van Meel K, Smekens A, Behets M, Kazandjian P, Van Grieken R, Analytical chemistry 79, 6383 (2007). http://doi.org/10.1021/AC070815R
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070815R
|
|
|
“Macroscopic X-ray powder diffraction scanning, a new method for highly selective chemical imaging of works of art : instrument optimization”. Vanmeert F, de Nolf W, De Meyer S, Dik J, Janssens K, Analytical chemistry 90, 6436 (2018). http://doi.org/10.1021/ACS.ANALCHEM.8B00240
Abstract: In the past decade macroscopic X-ray fluorescence imaging (MA-XRF) has become established as a method for the noninvasive investigation of flat painted surfaces, yielding large scale elemental maps. MA-XRF is limited by a lack of specificity, only allowing for indirect pigment identification based on the simultaneous presence of chemical elements. The high specificity of X-ray powder diffraction (XRPD) mapping is already being exploited at synchrotron facilities for investigations at the (sub)microscopic scale, but the technique has not yet been employed using lab sources. In this paper we present the development of a novel MA-XRPD/XRF instrument based on a laboratory X-ray source. Several combinations of X-ray sources and area detectors are evaluated in terms of their spatial and angular resolution and their sensitivity. The highly specific imaging capability of the combined MA-XRPD/XRF instrument is demonstrated on a 15th/16th century illuminated manuscript directly revealing the distribution of a large number of inorganic pigments, including the uncommon yellow pigment massicot (o-PbO). The case study illustrates the wealth of new mapping information that can be obtained in a noninvasive manner using the laboratory MA-XRPD/XRF instrument.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 11
DOI: 10.1021/ACS.ANALCHEM.8B00240
|
|
|
“Visualization of a lost painting by Vincent van Gogh using synchrotron radiation based X-ray fluorescence elemental mapping”. Dik J, Janssens K, van der Snickt G, van der Loeff L, Rickers K, Cotte M, Analytical chemistry 80, 6436 (2008). http://doi.org/10.1021/AC800965G
Abstract: Vincent van Gogh (1853−1890), one of the founding fathers of modern painting, is best known for his vivid colors, his vibrant painting style, and his short but highly productive career. His productivity is even higher than generally realized, as many of his known paintings cover a previous composition. This is thought to be the case in one-third of his early period paintings. Van Gogh would often reuse the canvas of an abandoned painting and paint a new or modified composition on top. These hidden paintings offer a unique and intimate insight into the genesis of his works. Yet, current museum-based imaging tools are unable to properly visualize many of these hidden images. We present the first-time use of synchrotron radiation based X-ray fluorescence mapping, applied to visualize a womans head hidden under the work Patch of Grass by Van Gogh. We recorded decimeter-scale, X-ray fluorescence intensity maps, reflecting the distribution of specific elements in the paint layers. In doing so we succeeded in visualizing the hidden face with unprecedented detail. In particular, the distribution of Hg and Sb in the red and light tones, respectively, enabled an approximate color reconstruction of the flesh tones. This reconstruction proved to be the missing link for the comparison of the hidden face with Van Goghs known paintings. Our approach literally opens up new vistas in the nondestructive study of hidden paint layers, which applies to the oeuvre of Van Gogh in particular and to old master paintings in general.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 178
DOI: 10.1021/AC800965G
|
|
|
“Macroscopic X-ray powder diffraction scanning : possibilities for quantitative and depth-selective parchment analysis”. Vanmeert F, de Nolf W, Dik J, Janssens K, Analytical chemistry 90, 6445 (2018). http://doi.org/10.1021/ACS.ANALCHEM.8B00241
Abstract: At or below the surface of painted works of art, valuable information is present that provides insights into an objects past, such as the artists technique and the creative process that was followed or its conservation history but also on its current state of preservation. Various noninvasive techniques have been developed over the past 2 decades that can probe this information either locally (via point analysis) or on a macroscopic scale (e.g., full-field imaging and raster scanning). Recently macroscopic X-ray powder diffraction (MA-XRPD) mapping using laboratory X-ray sources was developed. This method can visualize highly specific chemical distributions at the macroscale (dm(2)). In this work we demonstrate the synergy between the quantitative aspects of powder diffraction and the noninvasive scanning capability of MA-XRPD highlighting the potential of the method to reveal new types of information. Quantitative data derived from a 15th/16th century illuminated sheet of parchment revealed three lead white pigments with different hydrocerussite-cerussite compositions in specific pictorial elements, while quantification analysis of impurities in the blue azurite pigment revealed two distinct azurite types: one rich in barite and one in quartz. Furthermore, on the same artifact, the depth-selective possibilities of the method that stem from an exploitation of the shift of the measured diffraction peaks with respect to reference data are highlighted. The influence of different experimental parameters on the depth-selective analysis results is briefly discussed. Promising stratigraphic information could be obtained, even though the analysis is hampered by not completely understood variations in the unit cell dimensions of the crystalline pigment phases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 6
DOI: 10.1021/ACS.ANALCHEM.8B00241
|
|