“Damage functions and mechanism equations derived from limestone weathering in field exposure”. Delalieux F, Cardell-Fernandez C, Torfs K, Vleugels G, Van Grieken RE, Water, air and soil pollution 139, 75 (2002). http://doi.org/10.1023/A:1015827031669
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1015827031669
|
“Atmospheric particulate element concentrations and deposition rates in French Polynesia”. Rojas CM, Injuk J, Van Grieken RE, Maenhaut W, Journal de recherche océanographique 25, 74 (2000)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Micro-analysis of individual aerosol particles using electron, proton and laser beams”. de Bock LA, Jambers W, Van Grieken RE, South African journal of chemistry = Suid-Afrikaanse tydskrif vir chemie 49, 65 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
“Weathering of treated and untreated limestones in atmospheric exposures”. Vleugels GJ, Van Grieken RE, Journal of preservation technology 23, 48 (1991)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
“Study of the Antarctic aerosol using X-ray fluorescence and single particle analysis”. Rojas CM, Van Grieken RE, Cantillano ME, Scientific series of the Chilean Antarctic Institute (Ser. Cinet. INACH) 42, 37 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Phosphorus, calcium and lead distribution in collagen in lead induced soft tissue calcification : an ultrastructural and X-ray microanalytical study”. Vandeputte DF, Jacob WA, Van Grieken RE, Matrix 10, 33 (1990). http://doi.org/10.1016/S0934-8832(11)80135-6
Abstract: Repeated intraperitoneal injections of lead acetate in rats caused a calcification of the skin of the abdomen near the site of the injections. In the lead-induced calcifications, electron dense collagen bundles could be observed. On the surface of the collagen fibrils, needle-like crystals were visible. With energy-dispersive X-ray analysis, phosphorus, calcium and lead were detected in the electron dense collagen bundles. X-ray maps of the P-Kα, Ca-Kα, and Pb-Lα plus Pb-Lβ lines showed an equivalent distribution along the collagen fibrils for phosphorus and calcium. The occurrence of the most electron dense areas in the STEM-image was comparable to the lead distribution. A good correlation existed between the structural and the elemental images of the same area. Although the medicinal use of preparations containing lead is no longer recommended, some are still prescribed. From our results we can conclude that they should not be applied to injured or inflamed skin.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0934-8832(11)80135-6
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 60, 28r (1988). http://doi.org/10.1021/AC00163A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00163A002
|
“Study of aluminium-exposed fish by scanning proton microprobe analysis”. Eeckhaoudt S, Van Grieken RE, Cholewa M, Legge GJF, Microchimica acta 122, 17 (1996). http://doi.org/10.1007/BF01252401
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01252401
|
“Determination of barium, lanthanum, cerium and neodymium in lateritic materials by various energy-dispersive X-ray fluorescence techniques and neutron activation analysis”. Labrecque JJ, Beusen JM, Van Grieken RE, X-ray spectrometry 15, 13 (1986). http://doi.org/10.1002/XRS.1300150105
Abstract: A comparison of four methods for the determination of barium, lanthanum, cerium and neodymium in lateritic materials from Brazil is presented. Three of the methods were based on x-ray fluorescence (XRF) spectroscopy: two by radioisotope excitation (Co-57 and Am-241) and one by secondary target XRF (a molybdenum target with a tungsten anode). The other method was based on neutron activation analysis employing both a Ge(Li) coaxial detector and a high-purity germanium detector. The results from these four methods were similar for lanthanum, cerium and neodymium, but for barium at low concentrations (<500 ppm) the neutron activation and the secondary target XRF methods were not suitable. Data on the precision and accuracy of these methods using a series of standard reference rocks are given. The advantages and limitations of each of these methods with respect to the analysis of lateritic materials are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150105
|
“Applying digital image processing to SEM-EDX and BSE images to determine and quantify porosity and salts with depth in porous media”. Cardell C, Yebra A, Van Grieken RE, Microchimica acta 140, 9 (2002). http://doi.org/10.1007/S006040200063
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040200063
|
“Analysis of heterogeneous CaCO3-CaSO4 single particles using ultra-thin window EPMA”. Ro C-U, Oh K-Y, Van Grieken RE, (2000)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Application of proton induced X-ray emission analysis to the St. Louis regional air pollution study”. Akselsson R, Orsini C, Meinert DL, Johansson TB, Van Grieken RE, Kaufmann HC, Chapman KR, Nelson JW, Winchester JW, (1976)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Background aerosol concentrations at the Namib-Atlantic interface”. Annegarn HJ, Van Grieken RE, Winchester JW, Sellschop JPF, von Blottnitz F, (1979)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Characterisation of individual suspension particles in the Ems estuary”. Bernard PC, Van Grieken RE, Eisma D, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Evaluation of different techniques used to determine aluminium in patients with chronic renal failure”. Visser WJ, Van de Vyver FL, Verbueken AH, d'Haese P, Bekaert AB, Van Grieken RE, Duursma SA, de Broe ME, (1985)
Keywords: P3 Proceeding; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“LAMMA in nephrotoxicity studies”. Verbueken AH, Paulus GJ, Van de Vyver FL, Verpooten GA, Visser WJ, de Broe ME, Van Grieken RE, (1984)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Use of grazing emission XRF spectrometry for silicon wafer surface contamination measurements”. de Gendt S, Kenis K, Mertens PW, Heyns MM, Claes M, Van Grieken RE, Bailleul A, Knotter M, de Bokx PK, (1996)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|