Home | << 1 2 3 4 5 6 >> |
Records | |||||
---|---|---|---|---|---|
Author | Radtke, G.; Botton, G.A.; Verbeeck, J. | ||||
Title | Electron inelastic, scattering and anisotropy: the two-dimensional point of view | Type | A1 Journal article | ||
Year | 2006 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 106 | Issue | 11-12 | Pages | 1082-1090 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The measurement of the electronic structure of anisotropic materials using energy loss near edge structure (ELNES) spectroscopy is an important field of microanalysis in transmission electron microscopy. We present a novel method to study the angular dependence of electron inelastic scattering in anisotropic materials. This method has been applied to the study of 1s -> pi* and sigma* transitions on the carbon K edge in pyrolitic graphite. An excellent agreement between experimental and theoretical two-dimensional scattering patterns has been found. In particular, the need of a fully relativistic calculation of the inelastic scattering cross-section to explain the experimental results is demonstrated. (c) 2006 Elsevier B.V. All rights reserved. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000241592900018 | Publication Date | 2006-07-04 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 5 | Open Access | |
Notes | Approved | Most recent IF: 2.843; 2006 IF: 1.706 | |||
Call Number | UA @ lucian @ c:irua:61381UA @ admin @ c:irua:61381 | Serial | 936 | ||
Permanent link to this record | |||||
Author | Van Aert, S.; Verbeeck, J.; Erni, R.; Bals, S.; Luysberg, M.; van Dyck, D.; Van Tendeloo, G. | ||||
Title | Quantitative atomic resolution mapping using high-angle annular dark field scanning transmission electron microscopy | Type | A1 Journal article | ||
Year | 2009 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 109 | Issue | 10 | Pages | 1236-1244 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | A model-based method is proposed to relatively quantify the chemical composition of atomic columns using high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) images. The method is based on a quantification of the total intensity of the scattered electrons for the individual atomic columns using statistical parameter estimation theory. In order to apply this theory, a model is required describing the image contrast of the HAADF STEM images. Therefore, a simple, effective incoherent model has been assumed which takes the probe intensity profile into account. The scattered intensities can then be estimated by fitting this model to an experimental HAADF STEM image. These estimates are used as a performance measure to distinguish between different atomic column types and to identify the nature of unknown columns with good accuracy and precision using statistical hypothesis testing. The reliability of the method is supported by means of simulated HAADF STEM images as well as a combination of experimental images and electron energy-loss spectra. It is experimentally shown that statistically meaningful information on the composition of individual columns can be obtained even if the difference in averaged atomic number Z is only 3. Using this method, quantitative mapping at atomic resolution using HAADF STEM images only has become possible without the need of simultaneously recorded electron energy loss spectra. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000270015200004 | Publication Date | 2009-05-28 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 166 | Open Access | |
Notes | Fwo; Esteem 026019 | Approved | Most recent IF: 2.843; 2009 IF: 2.067 | ||
Call Number | UA @ lucian @ c:irua:78585UA @ admin @ c:irua:78585 | Serial | 2748 | ||
Permanent link to this record | |||||
Author | Goris, B.; Bals, S.; van den Broek, W.; Verbeeck, J.; Van Tendeloo, G. | ||||
Title | Exploring different inelastic projection mechanisms for electron tomography | Type | A1 Journal article | ||
Year | 2011 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 111 | Issue | 8 | Pages | 1262-1267 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | Several different projection mechanisms that all make use of inelastically scattered electrons are used for electron tomography. The advantages and the disadvantages of these methods are compared to HAADFSTEM tomography, which is considered as the standard electron tomography technique in materials science. The different inelastic setups used are energy filtered transmission electron microscopy (EFTEM), thickness mapping based on the log-ratio method and bulk plasmon mapping. We present a comparison that can be used to select the best inelastic signal for tomography, depending on different parameters such as the beam stability and nature of the sample. The appropriate signal will obviously also depend on the exact information which is requested. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000300461100039 | Publication Date | 2011-03-07 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 21 | Open Access | |
Notes | Fwo; Iap; Esteem 026019 | Approved | Most recent IF: 2.843; 2011 IF: 2.471 | ||
Call Number | UA @ lucian @ c:irua:91260UA @ admin @ c:irua:91260 | Serial | 1151 | ||
Permanent link to this record | |||||
Author | Verbeeck, J.; Bertoni, G. | ||||
Title | Deconvolution of core electron energy loss spectra | Type | A1 Journal article | ||
Year | 2009 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 109 | Issue | 11 | Pages | 1343-1352 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Different deconvolution methods for removing multiple scattering and instrumental broadening from core loss electron energy loss spectra are compared with special attention to the artefacts they introduce. The Gaussian modifier method, Wiener filter, maximum entropy, and model based methods are described. Their performance is compared on virtual spectra where the true single scattering distribution is known. A test on experimental spectra confirms the good performance of model based deconvolution in comparison to maximum entropy methods and shows the advantage of knowing the estimated error bars from a single spectrum acquisition. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000270765800005 | Publication Date | 2009-07-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 13 | Open Access | |
Notes | Fwo; Esteem 026019 | Approved | Most recent IF: 2.843; 2009 IF: 2.067 | ||
Call Number | UA @ lucian @ c:irua:79073UA @ admin @ c:irua:79073 | Serial | 610 | ||
Permanent link to this record | |||||
Author | Wang, A.; Chen, F.R.; Van Aert, S.; van Dyck, D. | ||||
Title | A method to determine the local surface profile from reconstructed exit waves | Type | A1 Journal article | ||
Year | 2011 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 111 | Issue | 8 | Pages | 1352-1359 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | Reconstructed exit waves are useful to quantify unknown structure parameters such as the position and composition of the atom columns at atomic scale. Existing techniques provide a complex wave in a flat plane which is close to the plane where the electrons leave the atom columns. However, due to local deviation in the flatness of the exit surface, there will be an offset between the plane of reconstruction and the actual exit of a specific atom column. Using the channelling theory, it has been shown that this defocus offset can in principle be determined atom column-by-atom column. As such, the surface roughness could be quantified at atomic scale. However, the outcome strongly depends on the initial plane of reconstruction especially in a crystalline structure. If this plane is further away from the true exit, the waves of the atom columns become delocalized and interfere mutually which strongly complicates the interpretation of the exit wave in terms of the local structure. In this paper, we will study the delocalization with defocus using the channelling theory in a more systematic way. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000300461100049 | Publication Date | 2011-05-03 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 3 | Open Access | |
Notes | Fwo | Approved | Most recent IF: 2.843; 2011 IF: 2.471 | ||
Call Number | UA @ lucian @ c:irua:88941 | Serial | 2017 | ||
Permanent link to this record | |||||
Author | Ke, X.; Bals, S.; Romo Negreira, A.; Hantschel, T.; Bender, H.; Van Tendeloo, G. | ||||
Title | TEM sample preparation by FIB for carbon nanotube interconnects | Type | A1 Journal article | ||
Year | 2009 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 109 | Issue | 11 | Pages | 1353-1359 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000270765800006 | Publication Date | 2009-07-11 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 21 | Open Access | |
Notes | Esteem 026019; Iap | Approved | Most recent IF: 2.843; 2009 IF: 2.067 | ||
Call Number | UA @ lucian @ c:irua:79074 | Serial | 3485 | ||
Permanent link to this record | |||||
Author | Van Aert, S.; Chen, J.H.; van Dyck, D. | ||||
Title | Linear versus non-linear structural information limit in high-resolution transmission electron microscopy | Type | A1 Journal article | ||
Year | 2010 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 110 | Issue | 11 | Pages | 1404-1410 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | A widely used performance criterion in high-resolution transmission electron microscopy (HRTEM) is the information limit. It corresponds to the inverse of the maximum spatial object frequency that is linearly transmitted with sufficient intensity from the exit plane of the object to the image plane and is limited due to partial temporal coherence. In practice, the information limit is often measured from a diffractogram or from Young's fringes assuming a weak phase object scattering beyond the inverse of the information limit. However, for an aberration corrected electron microscope, with an information limit in the sub-angstrom range, weak phase objects are no longer applicable since they do not scatter sufficiently in this range. Therefore, one relies on more strongly scattering objects such as crystals of heavy atoms observed along a low index zone axis. In that case, dynamical scattering becomes important such that the non-linear and linear interaction may be equally important. The non-linear interaction may then set the experimental cut-off frequency observed in a diffractogram. The goal of this paper is to quantify both the linear and the non-linear information transfer in terms of closed form analytical expressions. Whereas the cut-off frequency set by the linear transfer can be directly related with the attainable resolution, information from the non-linear transfer can only be extracted using quantitative, model-based methods. In contrast to the historic definition of the information limit depending on microscope parameters only, the expressions derived in this paper explicitly incorporate their dependence on the structure parameters as well. In order to emphasize this dependence and to distinguish from the usual information limit, the expressions derived for the inverse cut-off frequencies will be referred to as the linear and non-linear structural information limit. The present findings confirm the well-known result that partial temporal coherence has different effects on the transfer of the linear and non-linear terms, such that the non-linear imaging contributions are damped less than the linear imaging contributions at high spatial frequencies. This will be important when coherent aberrations such as spherical aberration and defocus are reduced. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000282562100008 | Publication Date | 2010-07-15 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 6 | Open Access | |
Notes | Fwo | Approved | Most recent IF: 2.843; 2010 IF: 2.063 | ||
Call Number | UA @ lucian @ c:irua:83689 | Serial | 1821 | ||
Permanent link to this record | |||||
Author | Schattschneider, P.; Verbeeck, J. | ||||
Title | Theory of free electron vortices | Type | A1 Journal article | ||
Year | 2011 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 111 | Issue | 9/10 | Pages | 1461-1468 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The recent creation of electron vortex beams and their first practical application motivates a better understanding of their properties. Here, we develop the theory of free electron vortices with quantized angular momentum, based on solutions of the Schrödinger equation for cylindrical boundary conditions. The principle of transformation of a plane wave into vortices with quantized angular momentum, their paraxial propagation through round magnetic lenses, and the effect of partial coherence are discussed. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000300461200002 | Publication Date | 2011-07-26 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 57 | Open Access | |
Notes | Esteem 026019 | Approved | Most recent IF: 2.843; 2011 IF: 2.471 | ||
Call Number | UA @ lucian @ c:irua:91882 | Serial | 3617 | ||
Permanent link to this record | |||||
Author | de Backer, A.; Van Aert, S.; van Dyck, D. | ||||
Title | High precision measurements of atom column positions using model-based exit wave reconstruction | Type | A1 Journal article | ||
Year | 2011 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 111 | Issue | 9/10 | Pages | 1475-1482 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | In this paper, it has been investigated how to measure atom column positions as accurately and precisely as possible using a focal series of images. In theory, it is expected that the precision would considerably improve using a maximum likelihood estimator based on the full series of focal images. As such, the theoretical lower bound on the variances of the unknown atom column positions can be attained. However, this approach is numerically demanding. Therefore, maximum likelihood estimation has been compared with the results obtained by fitting a model to a reconstructed exit wave rather than to the full series of focal images. Hence, a real space model-based exit wave reconstruction technique based on the channelling theory is introduced. Simulations show that the reconstructed complex exit wave contains the same amount of information concerning the atom column positions as the full series of focal images. Only for thin samples, which act as weak phase objects, this information can be retrieved from the phase of the reconstructed complex exit wave. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000300461200004 | Publication Date | 2011-07-28 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 8 | Open Access | |
Notes | Fwo | Approved | Most recent IF: 2.843; 2011 IF: 2.471 | ||
Call Number | UA @ lucian @ c:irua:91879 | Serial | 1438 | ||
Permanent link to this record | |||||
Author | van den Broek, W.; Van Aert, S.; van Dyck, D. | ||||
Title | A model based atomic resolution tomographic algorithm | Type | A1 Journal article | ||
Year | 2009 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 109 | Issue | 12 | Pages | 1485-1490 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | Tomography with high angular annular dark field scanning transmission electron microscopy at atomic resolution can be greatly improved if one is able to take advantage of prior knowledge. In this paper we present a reconstruction technique that explicitly takes into account the microscope parameters and the atomic nature of the projected object. This results in a more accurate estimate of the atomic positions and in a good resistance to noise. The reconstruction is a maximum likelihood estimator of the object. Moreover, the limits to the precision have been explored, allowing for a prediction of the amount of expected noise in the reconstruction for a certain experimental setup. We believe that the proposed reconstruction technique can be generalized to other tomographic experiments. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000271840200010 | Publication Date | 2009-08-28 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 17 | Open Access | |
Notes | Approved | Most recent IF: 2.843; 2009 IF: 2.067 | |||
Call Number | UA @ lucian @ c:irua:78588 | Serial | 2097 | ||
Permanent link to this record | |||||
Author | Rosenauer, A.; Schowalter, M.; Titantah, J.T.; Lamoen, D. | ||||
Title | An emission-potential multislice approximation to simulate thermal diffuse scattering in high-resolution transmission electron microscopy | Type | A1 Journal article | ||
Year | 2008 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 108 | Issue | 12 | Pages | 1504-1513 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Thermal diffuse scattered electrons significantly contribute to high-resolution transmission electron microscopy images. Their intensity adds to the background and is peaked at positions of atomic columns. In this paper we suggest an approximation to simulate intensity of thermal diffuse scattered electrons in plane-wave illumination transmission electron microscopy using an emission-potential multislice algorithm which is computationally less intensive than the frozen lattice approximation or the mutual intensity approach. Intensity patterns are computed for Au and InSb for different crystal orientations. These results are compared with intensities from the frozen lattice approximation based on uncorrelated vibration of atoms as well as with the frozen phonon approximation for Au. The frozen phonon method uses a detailed phonon model based on force constants we computed by a density functional theory approach. The comparison shows that our suggested emission-potential method is in close agreement with both the frozen lattice and the frozen phonon approximations. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000260808300002 | Publication Date | 2008-04-21 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 25 | Open Access | |
Notes | Approved | Most recent IF: 2.843; 2008 IF: 2.629 | |||
Call Number | UA @ lucian @ c:irua:72919 | Serial | 1033 | ||
Permanent link to this record | |||||
Author | Croitoru, M.D.; van Dyck, D.; Liu, Y.Z.; Zhang, Z. | ||||
Title | Measurement of specimen thickness by phase change determination in TEM | Type | A1 Journal article | ||
Year | 2008 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 108 | Issue | 12 | Pages | 1616-1622 |
Keywords | A1 Journal article; Condensed Matter Theory (CMT); Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | A non-destructive method for measuring the thickness of thin amorphous films composed of light elements has been developed. The method employs the statistics of the phase of the electron exit wave function. The accuracy of this method has been checked numerically by the multislice method and compared with that based on the mean inner potential. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000260808300016 | Publication Date | 2008-06-23 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 2 | Open Access | |
Notes | Approved | Most recent IF: 2.843; 2008 IF: 2.629 | |||
Call Number | UA @ lucian @ c:irua:75643 | Serial | 1961 | ||
Permanent link to this record | |||||
Author | Velazco, A.; Nord, M.; Béché, A.; Verbeeck, J. | ||||
Title | Evaluation of different rectangular scan strategies for STEM imaging | Type | A1 Journal article | ||
Year | 2020 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | Issue | Pages | 113021 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | STEM imaging is typically performed by raster scanning a focused electron probe over a sample. Here we investigate and compare three different scan patterns, making use of a programmable scan engine that allows to arbitrarily set the sequence of probe positions that are consecutively visited on the sample. We compare the typical raster scan with a so-called ‘snake’ pattern where the scan direction is reversed after each row and a novel Hilbert scan pattern that changes scan direction rapidly and provides an homogeneous treatment of both scan directions. We experimentally evaluate the imaging performance on a single crystal test sample by varying dwell time and evaluating behaviour with respect to sample drift. We demonstrate the ability of the Hilbert scan pattern to more faithfully represent the high frequency content of the image in the presence of sample drift. It is also shown that Hilbert scanning provides reduced bias when measuring lattice parameters from the obtained scanned images while maintaining similar precision in both scan directions which is especially important when e.g. performing strain analysis. Compared to raster scanning with flyback correction, both snake and Hilbert scanning benefit from dose reduction as only small probe movement steps occur. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000544042800007 | Publication Date | 2020-05-21 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 13 | Open Access | OpenAccess |
Notes | A.V., A.B. and J.V. acknowledge funding through FWO project G093417N ('Compressed sensing enabling low dose imaging in transmission electron microscopy') from the Flanders Research Fund. M.N. received support for this work from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 838001. J.V acknowledges funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 823717 – ESTEEM3. | Approved | Most recent IF: 2.2; 2020 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:169225 | Serial | 6369 | ||
Permanent link to this record | |||||
Author | Fatermans, J.; den Dekker, Aj.; Müller-Caspary, K.; Gauquelin, N.; Verbeeck, J.; Van Aert, S. | ||||
Title | Atom column detection from simultaneously acquired ABF and ADF STEM images | Type | A1 Journal article | ||
Year | 2020 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 219 | Issue | Pages | 113046 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | In electron microscopy, the maximum a posteriori (MAP) probability rule has been introduced as a tool to determine the most probable atomic structure from high-resolution annular dark-field (ADF) scanning transmission electron microscopy (STEM) images exhibiting low contrast-to-noise ratio (CNR). Besides ADF imaging, STEM can also be applied in the annular bright-field (ABF) regime. The ABF STEM mode allows to directly visualize light-element atomic columns in the presence of heavy columns. Typically, light-element nanomaterials are sensitive to the electron beam, limiting the incoming electron dose in order to avoid beam damage and leading to images exhibiting low CNR. Therefore, it is of interest to apply the MAP probability rule not only to ADF STEM images, but to ABF STEM images as well. In this work, the methodology of the MAP rule, which combines statistical parameter estimation theory and model-order selection, is extended to be applied to simultaneously acquired ABF and ADF STEM images. For this, an extension of the commonly used parametric models in STEM is proposed. Hereby, the effect of specimen tilt has been taken into account, since small tilts from the crystal zone axis affect, especially, ABF STEM intensities. Using simulations as well as experimental data, it is shown that the proposed methodology can be successfully used to detect light elements in the presence of heavy elements. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000594768500005 | Publication Date | 2020-06-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 9 | Open Access | OpenAccess |
Notes | The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (No. W.O.010.16N, No. G.0368.15N, No. G.0502.18N, EOS 30489208). This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 770887). The authors acknowledge funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 823717 – ESTEEM3. The direct electron detector (Medipix3, Quantum Detectors) was funded by the Hercules fund from the Flemish Government. K. M. C. acknowledges funding from the Initiative and Network Fund of the Helmholtz Association (Germany) under contract VH-NG-1317. The authors thank Mark Huijben from the University of Twente (Enschede, The Netherlands) for providing the LiMn2O4 sample used in section 4.2 of this study. N. G., J. V., and S. V. A. acknowledge funding from the University of Antwerp through the Concerted Research Actions (GOA) project Solarpaint and the TOP project. | Approved | Most recent IF: 2.2; 2020 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:169706 | Serial | 6373 | ||
Permanent link to this record | |||||
Author | Gorji, S.; Kashiwar, A.; Mantha, L.S.; Kruk, R.; Witte, R.; Marek, P.; Hahn, H.; Kübel, C.; Scherer, T. | ||||
Title | Nanowire facilitated transfer of sensitive TEM samples in a FIB | Type | A1 Journal article | ||
Year | 2020 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 219 | Issue | Pages | 113075 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | We introduce a facile approach to transfer thin films and other mechanically sensitive TEM samples inside a FIB with minimal introduction of stress and bending. The method is making use of a pre-synthetized flexible freestanding Ag nanowire attached to the tip of a typical tungsten micromanipulator inside the FIB. The main advantages of this approach are the significantly reduced stress-induced bending during transfer and attachment of the TEM sample, the very short time required to attach and cut the nanowire, the operation at very low dose and ion current, and only using the e-beam for Pt deposition during the transfer of sensitive TEM samples. This results in a reduced sample preparation time and reduced exposure to the ion beam or e-beam for Pt deposition during the sample preparation and thus also reduced contamination and beam damage. The method was applied to a number of thin films and different TEM samples in order to illustrate the advantageous benefits of the concept. In particular, the technique has been successfully tested for the transfer of a thin film onto a MEMS heating chip for in situ TEM experiments. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | Publication Date | 2020-07-15 | ||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record | |
Impact Factor | 2.2 | Times cited | Open Access | ||
Notes | Approved | Most recent IF: 2.2; 2020 IF: 2.843 | |||
Call Number | UA @ admin @ c:irua:183618 | Serial | 6871 | ||
Permanent link to this record | |||||
Author | Prabhakara, V.; Jannis, D.; Guzzinati, G.; Béché, A.; Bender, H.; Verbeeck, J. | ||||
Title | HAADF-STEM block-scanning strategy for local measurement of strain at the nanoscale | Type | A1 Journal article | ||
Year | 2020 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 219 | Issue | Pages | 113099 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Lattice strain measurement of nanoscale semiconductor devices is crucial for the semiconductor industry as strain substantially improves the electrical performance of transistors. High resolution scanning transmission electron microscopy (HR-STEM) imaging is an excellent tool that provides spatial resolution at the atomic scale and strain information by applying Geometric Phase Analysis or image fitting procedures. However, HR-STEM images regularly suffer from scanning distortions and sample drift during image acquisition. In this paper, we propose a new scanning strategy that drastically reduces artefacts due to drift and scanning distortion, along with extending the field of view. It consists of the acquisition of a series of independent small subimages containing an atomic resolution image of the local lattice. All subimages are then analysed individually for strain by fitting a nonlinear model to the lattice images. The method allows flexible tuning of spatial resolution and the field of view within the limits of the dynamic range of the scan engine while maintaining atomic resolution sampling within the subimages. The obtained experimental strain maps are quantitatively benchmarked against the Bessel diffraction technique. We demonstrate that the proposed scanning strategy approaches the performance of the diffraction technique while having the advantage that it does not require specialized diffraction cameras. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000594768500006 | Publication Date | 2020-09-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 4 | Open Access | OpenAccess |
Notes | A.B. D.J. and J.V. acknowledge funding through FWO project G093417N ('Compressed sensing enabling low dose imaging in transmission electron microscopy') from the Flanders Research Fund. J.V acknowledges funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 823717 – ESTEEM3. The Qu-Ant-EM microscope and the direct electron detector used in the diffraction experiments was partly funded by the Hercules fund from the Flemish Government. This project has received funding from the GOA project “Solarpaint” of the University of Antwerp. GG acknowledges support from a postdoctoral fellowship grant from the Fonds Wetenschappelijk Onderzoek – Vlaanderen (FWO). Special thanks to Dr. Thomas Nuytten, Prof. Dr. Wilfried Vandervorst, Dr. Paola Favia, Dr. Olivier Richard from IMEC, Leuven and Prof. Dr. Sara Bals from EMAT, Antwerp for their continuous support and collaboration with the project and to the IMEC processing group for the device fabrication. | Approved | Most recent IF: 2.2; 2020 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:172485 | Serial | 6404 | ||
Permanent link to this record | |||||
Author | De wael, A.; De Backer, A.; Van Aert, S. | ||||
Title | Hidden Markov model for atom-counting from sequential ADF STEM images: Methodology, possibilities and limitations | Type | A1 Journal article | ||
Year | 2020 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 219 | Issue | Pages | 113131 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | We present a quantitative method which allows us to reliably measure dynamic changes in the atomic structure of monatomic crystalline nanomaterials from a time series of atomic resolution annular dark field scanning transmission electron microscopy images. The approach is based on the so-called hidden Markov model and estimates the number of atoms in each atomic column of the nanomaterial in each frame of the time series. We discuss the origin of the improved performance for time series atom-counting as compared to the current state-of-the-art atom-counting procedures, and show that the so-called transition probabilities that describe the probability for an atomic column to lose or gain one or more atoms from frame to frame are particularly important. Using these transition probabilities, we show that the method can also be used to estimate the probability and cross section related to structural changes. Furthermore, we explore the possibilities for applying the method to time series recorded under variable environmental conditions. The method is shown to be promising for a reliable quantitative analysis of dynamic processes such as surface diffusion, adatom dynamics, beam effects, or in situ experiments. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000594770500003 | Publication Date | 2020-10-03 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes | This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 770887 and No. 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through grants to A.D.w. and A.D.B. and projects G.0502.18N and EOS 30489208. | Approved | Most recent IF: 2.2; 2020 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:172449 | Serial | 6417 | ||
Permanent link to this record | |||||
Author | Vanrompay, H.; Skorikov, A.; Bladt, E.; Béché, A.; Freitag, B.; Verbeeck, J.; Bals, S. | ||||
Title | Fast versus conventional HAADF-STEM tomography of nanoparticles: advantages and challenges | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 221 | Issue | Pages | 113191 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | HAADF-STEM tomography is a widely used experimental technique for analyzing nanometer-scale crystalline structures of a large variety of materials in three dimensions. Unfortunately, the acquisition of conventional HAADF-STEM tilt series can easily take up one hour or more, depending on the complexity of the experiment. It is therefore far from straightforward to investigate samples that do not withstand long acquisition or to acquire large amounts of tilt series during a single TEM experiment. The latter would lead to the ability to obtain statistically meaningful 3D data, or to perform in situ 3D characterizations with a much shorter time resolution. Various HAADF-STEM acquisition strategies have been proposed to accelerate the tomographic acquisition and reduce the required electron dose. These methods include tilting the holder continuously while acquiring a projection “movie” and a hybrid, incremental, methodology which combines the benefits of the conventional and continuous technique. However, until now an experimental evaluation has been lacking. In this paper, the different acquisition strategies will be experimentally compared in terms of speed, resolution and electron dose. This evaluation will be performed based on experimental tilt series acquired for various metallic nanoparticles with different shapes and sizes. We discuss the data processing involved with the fast HAADF-STEM tilt series and provide a general guideline when which acquisition strategy should be preferentially used. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000612539600003 | Publication Date | 2020-12-08 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 15 | Open Access | OpenAccess |
Notes | We acknowledge Prof. Luis M. Liz-Marzán and co-workers of the Bionanoplasmonics Laboratory, CIC biomaGUNE, Spain for providing the Au@Ag nanoparticles, Prof. Sara. E. Skrabalak and co-workers of Indiana University, United States for the provision of the Au octopods and Prof. Teri W. Odom of Northwestern University, United States for the provision of the Au nanostars. H.V. acknowledges financial support by the Research Foundation Flanders (FWO grant 1S32617N). S.B acknowledges financial support by the Research Foundation Flanders (FWO grant G.0381.16N). This project received funding as well from the European Union’s Horizon 2020 research and innovation program under grant agreement No 731019 (EUSMI) and No 815128 (REALNANO). The authors acknowledge the entire EMAT technical staff for their support.; sygma | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:174551 | Serial | 6660 | ||
Permanent link to this record | |||||
Author | Li, C.; Tardajos, A.P.; Wang, D.; Choukroun, D.; Van Daele, K.; Breugelmans, T.; Bals, S. | ||||
Title | A simple method to clean ligand contamination on TEM grids | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 221 | Issue | Pages | 113195 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Applied Electrochemistry & Catalysis (ELCAT) | ||||
Abstract | Colloidal nanoparticles (NPs) including nanowires and nanosheets made by chemical methods involve many organic ligands. When the structure of NPs is investigated via transmission electron microscopy (TEM), the organic ligands act as a source for e-beam induced deposition and this causes substantial build-up of carbon layers in the investigated areas, which is typically referred to as “contamination” in the eld of electron mi- croscopy. This contamination is often more severe for scanning TEM, a technique that is based on a focused electron beam and hence higher electron dose rate. In this paper, we report a simple and effective method to clean drop-cast TEM grids that contain NPs with ligands. Using a combination of activated carbon and ethanol, this method effectively reduces the amount of ligands on TEM grids, and therefore greatly improves the quality of electron microscopy images and subsequent analytical measurements. This ef cient and facile method can be helpful during electron microscopy investigation of different kinds of nanomaterials that suffer from ligand- induced contamination. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000612539600002 | Publication Date | 0000-00-00 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 10 | Open Access | OpenAccess |
Notes | This research was funded by the University Antwerp GOA project (ID 33928). DW acknowledges an Individual Fellowship funded by the Marie Sklodowska-Curie Actions (MSCA) in Horizon 2020 program (grant 894254 SuprAtom). | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:174947 | Serial | 6666 | ||
Permanent link to this record | |||||
Author | Koo, J.; Dahl, A.B.; Bærentzen, J.A.; Chen, Q.; Bals, S.; Dahl, V.A. | ||||
Title | Shape from projections via differentiable forward projector for computed tomography | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 224 | Issue | Pages | 113239 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | In computed tomography, the reconstruction is typically obtained on a voxel grid. In this work, however, we propose a mesh-based reconstruction method. For tomographic problems, 3D meshes have mostly been studied to simulate data acquisition, but not for reconstruction, for which a 3D mesh means the inverse process of estimating shapes from projections. In this paper, we propose a differentiable forward model for 3D meshes that bridge the gap between the forward model for 3D surfaces and optimization. We view the forward projection as a rendering process, and make it differentiable by extending recent work in differentiable rendering. We use the proposed forward model to reconstruct 3D shapes directly from projections. Experimental results for single-object problems show that the proposed method outperforms traditional voxel-based methods on noisy simulated data. We also apply the proposed method on electron tomography images of nanoparticles to demonstrate the applicability of the method on real data. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000744576800008 | Publication Date | 2021-03-11 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 3 | Open Access | OpenAccess |
Notes | EU Horizon 2020 MSCA Innovative Training Network MUMMERING Grant Number 765604. | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:183267 | Serial | 6825 | ||
Permanent link to this record | |||||
Author | De wael, A.; De Backer, A.; Lobato, I.; Van Aert, S. | ||||
Title | Modelling ADF STEM images using elliptical Gaussian peaks and its effects on the quantification of structure parameters in the presence of sample tilt | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | Issue | Pages | 113391 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | A small sample tilt away from a main zone axis orientation results in an elongation of the atomic columns in ADF STEM images. An often posed research question is therefore whether the ADF STEM image intensities of tilted nanomaterials should be quantified using a parametric imaging model consisting of elliptical rather than the currently used symmetrical peaks. To this purpose, simulated ADF STEM images corresponding to different amounts of sample tilt are studied using a parametric imaging model that consists of superimposed 2D elliptical Gaussian peaks on the one hand and symmetrical Gaussian peaks on the other hand. We investigate the quantification of structural parameters such as atomic column positions and scattering cross sections using both parametric imaging models. In this manner, we quantitatively study what can be gained from this elliptical model for quantitative ADF STEM, despite the increased parameter space and computational effort. Although a qualitative improvement can be achieved, no significant quantitative improvement in the estimated structure parameters is achieved by the elliptical model as compared to the symmetrical model. The decrease in scattering cross sections with increasing sample tilt is even identical for both types of parametric imaging models. This impedes direct comparison with zone axis image simulations. Nonetheless, we demonstrate how reliable atom-counting can still be achieved in the presence of small sample tilt. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000704334200001 | Publication Date | 2021-09-24 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | Open Access | OpenAccess | |
Notes | This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 770887 and No. 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through grants to A.D.w. and A.D.B. and projects G.0502.18N, G.0267.18N, and EOS 30489208. S.V.A. acknowledges TOP BOF funding from the University of Antwerp.; esteem3JRA; esteem3reported | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:181462 | Serial | 6810 | ||
Permanent link to this record | |||||
Author | Velazco, A.; Béché, A.; Jannis, D.; Verbeeck, J. | ||||
Title | Reducing electron beam damage through alternative STEM scanning strategies, Part I: Experimental findings | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 232 | Issue | Pages | 113398 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The highly energetic electrons in a transmission electron microscope (TEM) can alter or even completely destroy the structure of samples before sufficient information can be obtained. This is especially problematic in the case of zeolites, organic and biological materials. As this effect depends on both the electron beam and the sample and can involve multiple damage pathways, its study remained difficult and is plagued with irreproducibility issues, circumstantial evidence, rumors, and a general lack of solid data. Here we take on the experimental challenge to investigate the role of the STEM scan pattern on the damage behavior of a commercially available zeolite sample with the clear aim to make our observations as reproducible as possible. We make use of a freely programmable scan engine that gives full control over the tempospatial distribution of the electron probe on the sample and we use its flexibility to obtain multiple repeated experiments under identical conditions comparing the difference in beam damage between a conventional raster scan pattern and a newly proposed interleaved scan pattern that provides exactly the same dose and dose rate and visits exactly the same scan points. We observe a significant difference in beam damage for both patterns with up to 11 % reduction in damage (measured from mass loss). These observations demonstrate without doubt that electron dose, dose rate and acceleration voltage are not the only parameters affecting beam damage in (S)TEM experiments and invite the community to rethink beam damage as an unavoidable consequence of applied electron dose. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000714819200002 | Publication Date | 2021-10-02 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 18 | Open Access | OpenAccess |
Notes | A.V., D.J., A.B. and J.V. acknowledge funding from FWO project G093417N (’Compressed sensing enabling low dose imaging in transmission electron microscopy’) and G042920N (’Coincident event detection for advanced spectroscopy in transmission electron microscopy’). This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 823717 ESTEEM3. The Qu-Ant-EM microscope was partly funded by the Hercules fund from the Flemish Government. J.V. acknowledges funding from GOA project “Solarpaint” of the University of Antwerp.; JRA; reported | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:183282 | Serial | 6818 | ||
Permanent link to this record | |||||
Author | Jannis, D.; Hofer, C.; Gao, C.; Xie, X.; Béché, A.; Pennycook, Tj.; Verbeeck, J. | ||||
Title | Event driven 4D STEM acquisition with a Timepix3 detector: Microsecond dwell time and faster scans for high precision and low dose applications | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 233 | Issue | Pages | 113423 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Four dimensional scanning transmission electron microscopy (4D STEM) records the scattering of electrons in a material in great detail. The benefits offered by 4D STEM are substantial, with the wealth of data it provides facilitating for instance high precision, high electron dose efficiency phase imaging via centre of mass or ptychography based analysis. However the requirement for a 2D image of the scattering to be recorded at each probe position has long placed a severe bottleneck on the speed at which 4D STEM can be performed. Recent advances in camera technology have greatly reduced this bottleneck, with the detection efficiency of direct electron detectors being especially well suited to the technique. However even the fastest frame driven pixelated detectors still significantly limit the scan speed which can be used in 4D STEM, making the resulting data susceptible to drift and hampering its use for low dose beam sensitive applications. Here we report the development of the use of an event driven Timepix3 direct electron camera that allows us to overcome this bottleneck and achieve 4D STEM dwell times down to 100 ns; orders of magnitude faster than what has been possible with frame based readout. We characterize the detector for different acceleration voltages and show that the method is especially well suited for low dose imaging and promises rich datasets without compromising dwell time when compared to conventional STEM imaging. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000734396800003 | Publication Date | 2021-11-13 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 31 | Open Access | OpenAccess |
Notes | This project has received funding from the Euro- pean Union’s Horizon 2020 Research Infrastructure – Integrating Activities for Advanced Communities under grant agreement No 823717 – ESTEEM3. J.V. and A.B. acknowledge funding from FWO project G093417N (‘Compressed sensing enabling low dose imaging in transmission electron microscopy’). J.V. and D.J. ac- knowledge funding from FWO project G042920N ‘Co- incident event detection for advanced spectroscopy in transmission electron microscopy’. We acknowledge funding under the European Union’s Horizon 2020 re- search and innovation programme (J.V. and D.J un- der grant agreement No 101017720, FET-Proactive EBEAM, and C.H., C.G., X.X. and T.J.P. from the Eu- ropean Research Council (ERC) Grant agreement No. 802123-HDEM).; esteem3JRA; esteem3reported | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:183948 | Serial | 6828 | ||
Permanent link to this record | |||||
Author | Robert, Hl.; Lobato, I.; Lyu, Fj.; Chen, Q.; Van Aert, S.; Van Dyck, D.; Müller-Caspary, K. | ||||
Title | Dynamical diffraction of high-energy electrons investigated by focal series momentum-resolved scanning transmission electron microscopy at atomic resolution | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 233 | Issue | Pages | 113425 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | We report a study of scattering dynamics in crystals employing momentum-resolved scanning transmission electron microscopy under varying illumination conditions. As we perform successive changes of the probe focus, multiple real-space signals are obtained in dependence of the shape of the incident electron wave. With support from extensive simulations, each signal is shown to be characterised by an optimum focus for which the contrast is maximum and which differs among different signals. For instance, a systematic focus mismatch is found between images formed by high-angle scattering, being sensitive to thickness and chemical composition, and the first moment in diffraction space, being sensitive to electric fields. It follows that a single recording at one specific probe focus is usually insufficient to characterise materials comprehensively. Most importantly, we demonstrate in experiment and simulation that the second moment ( |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000734396800009 | Publication Date | 2021-11-13 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes | We thank Dr. Florian Winkler for valuable discussions and experimental work at the early stages of this study. This work was supported by the Initiative and Network Fund of the Helmholtz Association (Germany) under contracts VH-NG-1317 and ZT-I-0025. This project furthermore received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (grant agreement No. 770887). | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:184833 | Serial | 6898 | ||
Permanent link to this record | |||||
Author | Jannis, D.; Velazco, A.; Béché, A.; Verbeeck, J. | ||||
Title | Reducing electron beam damage through alternative STEM scanning strategies, Part II: Attempt towards an empirical model describing the damage process | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | Issue | Pages | 113568 | ||
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | In this second part of a series we attempt to construct an empirical model that can mimick all experimental observations made regarding the role of an alternative interleaved scan pattern in STEM imaging on the beam damage in a specific zeolite sample. We make use of a 2D diffusion model that describes the dissipation of the deposited beam energy in the sequence of probe positions that are visited during the scan pattern. The diffusion process allows for the concept of trying to ‘outrun’ the beam damage by carefully tuning the dwell time and distance between consecutively visited probe positions. We add a non linear function to include a threshold effect and evaluate the accumulated damage in each part of the image as a function of scan pattern details. Together, these ingredients are able to describe qualitatively all aspects of the experimental data and provide us with a model that could guide a further optimisation towards even lower beam damage without lowering the applied electron dose. We deliberately remain vague on what is diffusing here which avoids introducing too many sample specific details. This provides hope that the model can be applied also in sample classes that were not yet studied in such great detail by adjusting higher level parameters: a sample dependent diffusion constant and damage threshold. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000832788000003 | Publication Date | 0000-00-00 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 4 | Open Access | OpenAccess |
Notes | D.J., A.V, A.B. and J.V. acknowledge funding from FWO project G093417N (’Compressed sensing enabling low dose imaging in transmission electron microscopy’) and G042920N (’Coincident event detection for advanced spectroscopy in transmission electron microscopy’). This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 823717 ESTEEM3. The Qu-Ant-EM microscope was partly funded by the Hercules fund from the Flemish Government. J.V. acknowledges funding from GOA project “Solarpaint” of the University of Antwerp .; esteem3reported; esteem3jra; | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:188535 | Serial | 7071 | ||
Permanent link to this record | |||||
Author | Sentürk, D.G.; De Backer, A.; Friedrich, T.; Van Aert, S. | ||||
Title | Optimal experiment design for element specific atom counting using multiple annular dark field scanning transmission electron microscopy detectors | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 242 | Issue | Pages | 113626 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | This paper investigates the possible benefits for counting atoms of different chemical nature when analysing multiple 2D scanning transmission electron microscopy (STEM) images resulting from independent annular dark field (ADF) detector regimes. To reach this goal, the principles of statistical detection theory are used to quantify the probability of error when determining the number of atoms in atomic columns consisting of multiple types of elements. In order to apply this theory, atom-counting is formulated as a statistical hypothesis test, where each hypothesis corresponds to a specific number of atoms of each atom type in an atomic column. The probability of error, which is limited by the unavoidable presence of electron counting noise, can then be computed from scattering-cross sections extracted from multiple ADF STEM images. Minimisation of the probability of error as a function of the inner and outer angles of a specified number of independent ADF collection regimes results in optimal experimental designs. Based on simulations of spherical Au@Ag and Au@Pt core–shell nanoparticles, we investigate how the combination of two non-overlapping detector regimes helps to improve the probability of error when unscrambling two types of atoms. In particular, the combination of a narrow low angle ADF detector with a detector formed by the remaining annular collection regime is found to be optimal. The benefit is more significant if the atomic number Z difference becomes larger. In addition, we show the benefit of subdividing the detector regime into three collection areas for heterogeneous nanostructures based on a structure consisting of three types of elements, e.g., a mixture of Au, Ag and Al atoms. Finally, these results are compared with the probability of error resulting when one would ultimately use a pixelated 4D STEM detector and how this could help to further reduce the incident electron dose. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000873778100001 | Publication Date | 0000-00-00 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes | This work was supported by the European Research Council (Grant 770887 PICOMETRICS to S. Van Aert and Grant 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0346.21N and EOS 30489208) and a postdoctoral grant to A. De Backer. S. Van Aert acknowledges funding from the University of Antwerp Research fund (BOF).; esteem3reported; esteem3jra | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:190925 | Serial | 7118 | ||
Permanent link to this record | |||||
Author | Zhang, Z.; Lobato, I.; De Backer, A.; Van Aert, S.; Nellist, P. | ||||
Title | Fast generation of calculated ADF-EDX scattering cross-sections under channelling conditions | Type | A1 Journal article | ||
Year | 2023 | Publication | Ultramicroscopy | Abbreviated Journal | |
Volume | 246 | Issue | Pages | 113671 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Advanced materials often consist of multiple elements which are arranged in a complicated structure. Quantitative scanning transmission electron microscopy is useful to determine the composition and thickness of nanostructures at the atomic scale. However, significant difficulties remain to quantify mixed columns by comparing the resulting atomic resolution images and spectroscopy data with multislice simulations where dynamic scattering needs to be taken into account. The combination of the computationally intensive nature of these simulations and the enormous amount of possible mixed column configurations for a given composition indeed severely hamper the quantification process. To overcome these challenges, we here report the development of an incoherent non-linear method for the fast prediction of ADF-EDX scattering cross-sections of mixed columns under channelling conditions. We first explain the origin of the ADF and EDX incoherence from scattering physics suggesting a linear dependence between those two signals in the case of a high-angle ADF detector. Taking EDX as a perfect incoherent reference mode, we quantitatively examine the ADF longitudinal incoherence under different microscope conditions using multislice simulations. Based on incoherent imaging, the atomic lensing model previously developed for ADF is now expanded to EDX, which yields ADF-EDX scattering cross-section predictions in good agreement with multislice simulations for mixed columns in a core–shell nanoparticle and a high entropy alloy. The fast and accurate prediction of ADF-EDX scattering cross-sections opens up new opportunities to explore the wide range of ordering possibilities of heterogeneous materials with multiple elements. | ||||
Address | |||||
Corporate Author | Zezhong Zhang | Thesis | |||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000995063900001 | Publication Date | 2022-12-28 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes | European Research Council 770887 PICOMETRICS; Fonds Wetenschappelijk Onderzoek No.G.0502.18N; Horizon 2020, 770887 ; Horizon 2020 Framework Programme; European Research Council, 823717 ESTEEM3 ; esteem3reported; esteem3JRa | Approved | Most recent IF: 2.2; 2023 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:195890 | Serial | 7251 | ||
Permanent link to this record | |||||
Author | De Backer, A.; Bals, S.; Van Aert, S. | ||||
Title | A decade of atom-counting in STEM: From the first results toward reliable 3D atomic models from a single projection | Type | A1 Journal article | ||
Year | 2023 | Publication | Ultramicroscopy | Abbreviated Journal | |
Volume | Issue | Pages | 113702 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Quantitative structure determination is needed in order to study and understand nanomaterials at the atomic scale. Materials characterisation resulting in precise structural information is a crucial point to understand the structure–property relation of materials. Counting the number of atoms and retrieving the 3D atomic structure of nanoparticles plays an important role here. In this paper, an overview will be given of the atom-counting methodology and its applications over the past decade. The procedure to count the number of atoms will be discussed in detail and it will be shown how the performance of the method can be further improved. Furthermore, advances toward mixed element nanostructures, 3D atomic modelling based on the atom-counting results, and quantifying the nanoparticle dynamics will be highlighted. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000953765800001 | Publication Date | 2023-02-10 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 3 | Open Access | OpenAccess |
Notes | This work was supported by the European Research Council (Grant 770887 PICOMETRICS to S. Van Aert, Grant 815128 REALNANO to S. Bals, and Grant 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0267.18N, G.0502.18N, G.0346.21N, and EOS 30489208) and a postdoctoral grant to A. De Backer. S. Van Aert acknowledges funding from the University of Antwerp Research fund (BOF) . The authors also thank the colleagues who have contributed to this work over the years, including T. Altantzis, E. Arslan Irmak, K.J. Batenburg, E. Bladt, A. De wael, R. Erni, C. Faes, B. Goris, L. Jones, L.M. Liz-Marzán, I. Lobato, G.T. Martinez, P.D. Nellist, M.D. Rosell, A. Rosenauer, K.H.W. van den Bos, A. Varambhia, and Z. Zhang.; esteem3reported; esteem3JRA | Approved | Most recent IF: 2.2; 2023 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:195896 | Serial | 7236 | ||
Permanent link to this record | |||||
Author | Lobato, I.; De Backer, A.; Van Aert, S. | ||||
Title | Real-time simulations of ADF STEM probe position-integrated scattering cross-sections for single element fcc crystals in zone axis orientation using a densely connected neural network | Type | A1 Journal article | ||
Year | 2023 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 251 | Issue | Pages | 113769 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Quantification of annular dark field (ADF) scanning transmission electron microscopy (STEM) images in terms of composition or thickness often relies on probe-position integrated scattering cross sections (PPISCS). In order to compare experimental PPISCS with theoretically predicted ones, expensive simulations are needed for a given specimen, zone axis orientation, and a variety of microscope settings. The computation time of such simulations can be in the order of hours using a single GPU card. ADF STEM simulations can be efficiently parallelized using multiple GPUs, as the calculation of each pixel is independent of other pixels. However, most research groups do not have the necessary hardware, and, in the best-case scenario, the simulation time will only be reduced proportionally to the number of GPUs used. In this manuscript, we use a learning approach and present a densely connected neural network that is able to perform real-time ADF STEM PPISCS predictions as a function of atomic column thickness for most common face-centered cubic (fcc) crystals (i.e., Al, Cu, Pd, Ag, Pt, Au and Pb) along [100] and [111] zone axis orientations, root-mean-square displacements, and microscope parameters. The proposed architecture is parameter efficient and yields accurate predictions for the PPISCS values for a wide range of input parameters that are commonly used for aberration-corrected transmission electron microscopes. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 001011617200001 | Publication Date | 2023-06-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes | This work was supported by the European Research Council (Grant 770887 PICOMETRICS to S. Van Aert). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G034621N and G0A7723N) and a postdoctoral grant to A. De Backer. S. Van Aert acknowledges funding from the University of Antwerp Research fund (BOF), Belgium. | Approved | Most recent IF: 2.2; 2023 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:197275 | Serial | 8812 | ||
Permanent link to this record | |||||
Author | Denisov, N.; Jannis, D.; Orekhov, A.; Müller-Caspary, K.; Verbeeck, J. | ||||
Title | Characterization of a Timepix detector for use in SEM acceleration voltage range | Type | A1 Journal article | ||
Year | 2023 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 253 | Issue | Pages | 113777 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Hybrid pixel direct electron detectors are gaining popularity in electron microscopy due to their excellent properties. Some commercial cameras based on this technology are relatively affordable which makes them attractive tools for experimentation especially in combination with an SEM setup. To support this, a detector characterization (Modulation Transfer Function, Detective Quantum Efficiency) of an Advacam Minipix and Advacam Advapix detector in the 15–30 keV range was made. In the current work we present images of Point Spread Function, plots of MTF/DQE curves and values of DQE(0) for these detectors. At low beam currents, the silicon detector layer behaviour should be dominant, which could make these findings transferable to any other available detector based on either Medipix2, Timepix or Timepix3 provided the same detector layer is used. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 001026912700001 | Publication Date | 2023-06-08 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes | The authors acknowledge the financial support of the Research Foundation Flanders (FWO, Belgium) project SBO S000121N. The authors are grateful to Dr. Lobato for productive discussion of methods. | Approved | Most recent IF: 2.2; 2023 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:198258 | Serial | 8815 | ||
Permanent link to this record |