“Fast steel-cleanness characterization by means of laser-assisted plasma spectrometric methods”. Mueller G, Stahnke F, Bleiner D, Talanta : the international journal of pure and applied analytical chemistry
T2 –, 34th Colloquium Spectroscopicum Internationale, SEP 04-09, 2005, Univ Antwerp, Antwerp, BELGIUM (2006). http://doi.org/10.1016/J.TALANTA.2006.05.047
Abstract: Laser-assisted plasma spectrometry is a palette of analytical techniques (L-OES, LA-ICP-MS) capable of fast spatially-resolved elemental analysis in the micrometer range. For fast estimation of the occurrence in steel samples of non-metallic inclusions, which degrade the material's technical properties, simultaneous OES detection and sequential ICP-MS detection were compared. Histograms were obtained for the intensity distribution of the acquired signals (laser pulse statistics). The skewness coefficient of the histograms for Al (indicator of non-metallic inclusions) was found to be clearly dependent on the fraction of non-metallic inclusions in the case of scanning L-OES. For LA-ICP-MS less clear dependence was observed, which was influenced by the acquisition characteristics. In fact, less measurement throughput limited for LA-ICP-MS the counting statistics to an extent that overrides the benefit of higher detection power as compared to L-OES. (c) 2006 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
Times cited: 12
DOI: 10.1016/J.TALANTA.2006.05.047
|
|
|
“FIB, TEM and LA-ICPMS investigations on melt inclusions in Martian meteorites –, Analytical capabilities and geochemical insights”. Bleiner D, Macri M, Gasser P, Sautter V, Maras A, Talanta : the international journal of pure and applied analytical chemistry (2006). http://doi.org/10.1016/J.TALANTA.2005.08.022
Abstract: In order to obtain full information coverage on melt inclusions in Martian meteorites (subgroup nakhlites) complementary micro-analytical techniques were used, i.e. focused ion beam, transmission electron microscopy and laser ablation. Using focused ion beam several lamellae for transmission electron microscopy were prepared and secondary electron images of cross-sections could be acquired. Laser ablation-inductively coupled plasma mass spectrometry analyses were performed on selected inclusions to obtain mass-oriented bulk composition of inclusions at depth. The differences in composition between melt inclusions in olivine and augite crystals would suggest a xenocrystic origin for olivine. Furthermore, electron diffraction patterns clearly indicated that the SiO2-rich phase in inclusions from augite in meteorites from Northwest Africa site is re-crystallized, whereas it is still vitreous in the inclusions from Nakhla sampling site. Therefore, different post-entrapment evolutions were active for the two nakhlite meteorite sets, the Nakhla and the NWA817 set. Melt inclusions in Nakhla olivine presented alteration veins, which were presumably produced before their landing on Earth. If this is the case, this would indicate a alteration stage already on Mars with all the consequence in terms of climate history. Melt inclusions in Nakhla augite resulted unaffected by any alteration or modification following the entrapment, and therefore represent the best candidate to indicate the pristine magma composition. (c) 2005 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
Times cited: 9
DOI: 10.1016/J.TALANTA.2005.08.022
|
|
|
“Unlocking the full power of electrochemical fingerprinting for on-site sensing applications”. Moro G, Barich H, Driesen K, Montiel NF, Neven L, Mendonca CD, Thiruvottriyur Shanmugam S, Daems E, De Wael K, Analytical And Bioanalytical Chemistry , 1 (2020). http://doi.org/10.1007/S00216-020-02584-X
Abstract: Electrochemical sensing for the semi-quantitative detection of biomarkers, drugs, environmental contaminants, food additives, etc. shows promising results in point-of-care diagnostics and on-site monitoring. More specifically, electrochemical fingerprint (EF)-based sensing strategies are considered an inviting approach for the on-site detection of low molecular weight molecules. The fast growth of electrochemical sensors requires defining the concept of direct electrochemical fingerprinting in sensing. The EF can be defined as the unique electrochemical signal or pattern, mostly recorded by voltammetric techniques, specific for a certain molecule that can be used for its quantitative or semi-quantitative identification in a given analytical context with specified circumstances. The performance of EF-based sensors can be enhanced by considering multiple features of the signal (i.e., oxidation or reduction patterns), in combination with statistical data analysis or sample pretreatments or by including electrode surface modifiers to enrich the EF. In this manuscript, some examples of EF-based sensors, strategies to improve their performances, and open challenges are discussed to unlock the full power of electrochemical fingerprinting for on-site sensing applications.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.3
Times cited: 3
DOI: 10.1007/S00216-020-02584-X
|
|
|
“Characterization of individual particle types in coastal air by laser microprobe mass analysis”. Bruynseels F, Storms H, Tavares T, Van Grieken R, International journal of environmental analytical chemistry 23, 1 (1985). http://doi.org/10.1080/03067318508076430
Abstract: Laser Microprobe Mass Analysis (LAMMA) was used in a preliminary study to characterize aerosol particles from a beach and inland sites and from a heavily industrialized area. As many as six types of both positive and negative mass spectra with different inorganic and organic signals could be distinguished in the different particle size ranges. Information about the elemental composition and the speciation of S and N was obtained. With increasing distance from sea, progressive uptake of nitrate in seasalt particles was found. Complex particles, containing soot and organic ammonium sulfate, were also detected.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318508076430
|
|
|
“Single-run ion chromatographic separation of inorganic and low-molecular-mass organic anions under isocratic elution: application to environmental samples”. Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 79, 16 (2009). http://doi.org/10.1016/J.TALANTA.2009.02.044
Abstract: For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 ìm particle size), Allsep A-2 (7 ìm particle size), and IC SI-50 4E (5 ìm particle size). A complete baseline separation for all analyzed anions (i.e., F−, acetate, formate, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F−, Ac−, For−, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2009.02.044
|
|
|
“Characterization of individual estuarine and marine particles by LAMMA and EPXMA”. Wouters L, Bernard P, Van Grieken R, International journal of environmental analytical chemistry 34, 17 (1988). http://doi.org/10.1080/03067318808029918
Abstract: Laser microprobe mass analysis (LAMMA) was applied to particulate matter from the Atlantic Ocean. Inferring information about the surface layer by LAMMA was not probe X-ray microanalysis (EPXMA). Geochemically relevant groups of particles had been identified by EPXMA and cluster analysis. For both locations, the most abundant ones appeared to be those rich in silicon and the alumino-silicates. Afterwards LAMMA was applied to obtain more information about the trace element composition and surface characteristics. The iron-rich phase appeared to contain significant amounts of heavy metals and of phosphate. Lead appeared to be associated in detectable amounts with alumino-silicates in the Scheldt but not with those in the Atlantic Ocean. Inferring information about the surface layer by LAMMA was not always unambiguous.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318808029918
|
|
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 60, 28r (1988). http://doi.org/10.1021/AC00163A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00163A002
|
|
|
“The half-life of 28Al”. Van Schandevijl R, Van Grieken R, Hoste J, Journal of radioanalytical chemistry 9, 55 (1971). http://doi.org/10.1007/BF02514012
Abstract: The half-life of28Al was redetermined on aluminium samples of different origin. Three different counting techniques were applied. The availability of highly purified samples (up to 99.9999%), the use of very fast electronic counting equipment and a complete automatisation allowed a good precision to be obtained in the final result of 2.2405 min.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02514012
|
|
|
“Co-precipitation with iron hydroxide and X-ray fluorescence analysis of trace metals in water”. Chakravorty R, Van Grieken R, International journal of environmental analytical chemistry 11, 67 (1982). http://doi.org/10.1080/03067318208071563
Abstract: Preconcentration of transition trace ions by coprecipitation on iron-hydroxide has been combined with energy-dispersive X-ray fluorescence for environmental water analysis. The optimized preconcentration procedure implies adding 2 mg of iron to a 200 ml water sample, adding dilute NaOH up to pH 9, filtering off on a Nuclepore membrane after a 1 h equilibration time, and analyzing. Quantitative recoveries could then be obtained for Ni, Cu, Zn and Pb, e.g. at the 10 μg/l level in waters of varying salinity while Mn was partially collected. (In fact, for a given problem the iron carrier amount can be adjusted to obtain a satisfactory compromise between high recovery and low detection limit). The precision is 7-8% at the 10 μg/l level, and the detection limits are in the 0.5-1 μg/l range. Various environmental water samples are analysed by way of illustration.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318208071563
|
|
|
“Concentration profiles of metal contaminants in fluvial sediments of a rural-urban drainage basin in Tanzania”. Hellar-Kihampa H, Potgieter-Vermaak S, De Wael K, Lugwisha E, van Espen P, Van Grieken R, International journal of environmental analytical chemistry 94, 77 (2014). http://doi.org/10.1080/03067319.2013.791976
Abstract: This study investigated concentration profiles of trace, rare earth and platinum group metals in fluvial sediments from the Pangani river basin (43,650 km2), one of the largest river basins in Tanzania, to assess its environmental quality. Sediment samples were collected in two distinct seasons from 12 representative sites of diverse land-use practices and characterised by ICP-MS after optimised microwave digestion. Ecological risks were assessed by evaluation of pollution index and comparison with legislated sediment quality guidelines (SQG). The results revealed contamination by some trace metals (e.g. Pb, V, Cu, Cr, Ni, Cd, As, Co, Mn and Zn) in concentrations ranging from 0.7 to 2940 mg kg−1, and four rare earth elements (Y, Ce, Nd, Yb) in concentrations ranging from 0.9 (Yb) to 500 mg kg−1 dry weight (Ce), which significantly exceeded the estimated background values at some stations. Palladium was the only platinum group element that was detected in quantifiable concentrations (0.33.5 mg kg−1). Concentrations of some trace metals exceeded the SQGs at some localised areas. Principal component analysis and multivariate correlations indicated geochemical characteristics of the area as the major control of metal concentrations and spatial variability. Organic matter and clay contents also played a significant role in metal distributions. Assessment of land-use practices upstream of the sampling locations was used to trace potential anthropogenic sources of metal enrichments, where highest levels were found in areas close to urban centres and agricultural activities. The study provides baseline data for future monitoring programs, and highlights the need for more comprehensive analysis involving a wider spatio-temporal scale and ecotoxicological risk assessment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.208
Times cited: 5
DOI: 10.1080/03067319.2013.791976
|
|
|
“Chelating 2,2′-diaminodiethylamine cellulose filters and X-ray fluorescence for preconcentration and trace analysis of natural waters”. Smits J, Van Grieken R, International journal of environmental analytical chemistry 9, 81 (1981). http://doi.org/10.1080/03067318108071902
Abstract: The 2,2′-diaminodiethylamine (DEN) functional group can be expected to have ideal properties for the chelation of transition metals and their collection from aqueous solutions, independent of the alkali and alkaline earth ions concentration. Introducing DEN into cellulose filters allows straightforward preconcentration of trace cations by a simple filtration step, and the DEN-filter constitutes a suitable target for X-ray fluorescence (XRF) analysis. The linearity between the XRF-response on the loaded DEN-filter and the trace cation concentration in the solution appears excellent, up to a total filter capacity of ca. 3 μeq.cm−2. The detection limits are around 0.5 μg. l−1 in most practical cases. Accuracy and precision are around 10%. The applicability of the proposed procedure is illustrated on a comparative basis by XRF-analysis of drinking water and surface water, after preconcentration by DEN-filtration and by alternative procedures.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318108071902
|
|
|
“Spatial neutron flux distributions around A 14 MeV neutron generator”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 10, 95 (1972). http://doi.org/10.1007/BF02518771
Abstract: The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02518771
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 62, 101r (1990). http://doi.org/10.1021/AC00211A001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00211A001
|
|
|
“Emerging halogenated flame retardants in the indoor environment”. Poma G, McGrath TJ, Christia C, Govindan M, Covaci A, Comprehensive analytical chemistry 88, 107 (2020). http://doi.org/10.1016/BS.COAC.2019.10.004
Abstract: Indoor environments are considered an important contributor to external human exposure to halogenated flame retardants (HFRs) due to the large amounts of chemicals currently incorporated in indoor equipment and the time humans spend every day in indoor environments. In this chapter, the presence and use of novel brominated flame retardants (NBFRs), dechlorane plus (DPs), chlorinated organophosphorus flame retardants (Cl-PFRs) and chlorinated paraffins (CPs) in indoor dust, air and consumer products collected from different indoor microenvironments (homes, public indoor spaces, and vehicles) are discussed. While data on the concentrations of HFRs in indoor dust and air are widely available, figures are still scarce for consumer products, such as textiles and foams, furnishings, flooring, electric and electronic products and building materials. This knowledge gaps still represents the biggest obstacle in linking eventual sources of contamination to the presence and chemical patterns in indoor dust and air.
Keywords: A1 Journal article; Pharmacology. Therapy; Electron microscopy for materials research (EMAT); Toxicological Centre
DOI: 10.1016/BS.COAC.2019.10.004
|
|
|
“Present and future applications of beam techniques in environmental microanalysis”. Jambers W, Van Grieken R, Trends in analytical chemistry 15, 114 (1996). http://doi.org/10.1016/0165-9936(95)00098-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0165-9936(95)00098-4
|
|
|
“A general-purpose interface between fortran and the low-level functions of the ibm-pc”. Janssens K, van Espen P, Trends in analytical chemistry 7, 128 (1988). http://doi.org/10.1016/0165-9936(88)87009-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0165-9936(88)87009-2
|
|
|
“Mitigation strategies for radiation damage in the analysis of ancient materials”. Bertrand L, Schoeeder S, Anglos D, Breese MBH, Janssens K, Moini M, Simon A, Trends in analytical chemistry 66, 128 (2015). http://doi.org/10.1016/J.TRAC.2014.10.005
Abstract: The study of materials in cultural heritage artifacts and micro-samples benefits from diagnostic techniques based on intense radiation sources, such as synchrotrons, ion-beam accelerators and lasers. While most of the corresponding techniques are classified as non-destructive, investigation with photons or charged particles entails a number of fundamental processes that may induce changes in materials. These changes depend on irradiation parameters, properties of materials and environmental factors. In some cases, radiation-induced damage may be detected by visual inspection. When it is not, irradiation may still lead to atomic and molecular changes resulting in immediate or delayed alteration and bias of future analyses. Here we review the effects of radiation reported on a variety of cultural heritage materials and describe the usual practice for assessing short-term and long-term effects. This review aims to raise awareness and encourage subsequent research activities to limit radiation side effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 35
DOI: 10.1016/J.TRAC.2014.10.005
|
|
|
“X-ray spectrometry”. Török SB, Van Grieken RE, Analytical chemistry 64r, 180 (1992)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Characterization of aerosol-associated lead by DPASV and LAMMA”. Wonders JHAM, Houweling S, de Bont FAJ, van Leeuwen HP, Eeckhaoudt SM, Van Grieken R, International journal of environmental analytical chemistry 56, 193 (1994). http://doi.org/10.1080/03067319408034100
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319408034100
|
|
|
“X-ray spectrometry”. Szalóki I, Török SB, Ro C-U, Injuk J, Van Grieken RE, Analytical chemistry 72, 211 (2000). http://doi.org/10.1021/A1000018H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/A1000018H
|
|
|
“Trace metal analysis of water containing humic substances by X-ray fluorescence”. Vanderborght BM, Van Grieken RE, International journal of environmental analytical chemistry 5, 221 (1978). http://doi.org/10.1080/03067317808071147
Abstract: Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067317808071147
|
|
|
“Geometry errors in 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 13, 225 (1973). http://doi.org/10.1007/BF02514126
Abstract: The effects of inaccurate sample sizes and sample positioning on 14 MeV neutron activation analysis results are estimated for 30, 20 and 10 mm diameter targets. It appears that axial positioning is the most critical parameter and that using a larger tritium target will yield an overall improvement of the reproducibility.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02514126
|
|
|
“Leaching of nutrients and trace metals from aerosol samples: a comparison between a re-circulation and an ultrasound system”. Eyckmans K, Zhang J, de Hoog J, Joos P, Van Grieken R, International journal of environmental analytical chemistry 80, 227 (2001). http://doi.org/10.1080/03067310108044372
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067310108044372
|
|
|
“A microanalytical study of the gills of aluminium-exposed rainbow trout (Salmo gairdneri)”. Goossenaerts C, Van Grieken R, Jacob W, Witters H, Vanderborght O, International journal of environmental analytical chemistry 34, 227 (1988). http://doi.org/10.1080/03067319808026840
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319808026840
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Reviews in analytical chemistry 56, 241r (1984)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 58, 279r (1986). http://doi.org/10.1021/AC00296A019
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00296A019
|
|
|
“Investigation of heterogeneous reactions of PAH's on particle surfaces using laser microprobe mass analysis”. Niessner R, Klockow D, Bruynseels F, Van Grieken R, International journal of environmental analytical chemistry 22, 281 (1985). http://doi.org/10.1080/03067318508076427
Abstract: Artificially generated NaCl particles were coated with PAH's by using a condensation technique. These particles were exposed to reactive gases like ozone, bromine and nitrogen dioxide. The original as well as the exposed particles were investigated by fluorimetric analysis and by LAMMA (Laser Microprobe Mass Analysis) in the desorption mode, which allows the evaporation and characterization of surfaces of single particles. The results are interpreted in terms of possible heterogeneous atmospheric reactions. The reactivity of the considered PAH's towards nitrogen dioxide was found to be negligible. The structure of the reaction products formed with ozone was partially elucidated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318508076427
|
|
|
“Performance of total reflection and grazing emission X-ray fluorescence spectrometry for the determination of trace metals in drinking water in relation to other analytical techniques”. Hołynska B, Olko M, Ostachowicz B, Ostachowicz J, Wegrzynek D, Claes M, Van Grieken R, de Bokx P, Kump P, Necemer M, Fresenius' journal of analytical chemistry 362, 294 (1998). http://doi.org/10.1007/S002160051077
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051077
|
|
|
“Equilibrium constants for trace elements in natural waters”. Van 't dack L, Blommaert W, Vandelannoote R, Gijbels R, van Grieken R, Reviews in analytical chemistry 7, 297 (1983)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|