“Use of laser microprobe mass analysis (LAMMA) for localizing multiple elements in soft and hard tissues”. Verbueken AH, van de Vijver FL, Visser WJ, Roels F, Van Grieken R, de Broe ME, Biological trace element research 13, 397 (1987). http://doi.org/10.1007/BF02796651
Abstract: The potential of laser microprobe mass analysis (LAMMA) as a sensitive microanalytical technique was explored in applications relevant to nephrology. Aluminum and associated elements, such as iron, were localized in fresh tissue biopsies obtained from uremic patients treatment by chronic hemodialysis. The LAMMA was applied to serum, liver, bone, and parathyroid glands of such patients. In addition, we used LAMMA to evaluate the specificity and sensitivity of routine histochemistry, in particular on human bone sections stained by the aluminon method. The high, multielemental sensitivity and molecular microprobe potential of LAMMA established important advantages over other microchemical methods forin situ analysis at the micron level in histological sections.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/BF02796651
|
|
|
“The use of synchrotron radiation for the characterization of artists' pigments and paintings”. Janssens K, Alfeld M, van der Snickt G, de Nolf W, Vanmeert F, Radepont M, Monico L, et al, Annual review of analytical chemistry 6, 399 (2013). http://doi.org/10.1146/ANNUREV-ANCHEM-062012-092702
Abstract: We review methods and recent studies in which macroscopic to (sub)microscopic X-ray beams were used for nondestructive analysis and characterization of pigments, paint microsamples, and/or entire paintings. We discuss the use of portable laboratory- and synchrotron-based instrumentation and describe several variants of X-ray fluorescence (XRF) analysis used for elemental analysis and imaging and combined with X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Macroscopic and microscopic (μ-)XRF variants of this method are suitable for visualizing the elemental distribution of key elements in paint multilayers. Technical innovations such as multielement, large-area XRF detectors have enabled such developments. The use of methods limited to elemental analysis or imaging usually is not sufficient to elucidate the chemical transformations that take place during natural pigment alteration processes. However, synchrotron-based combinations of μ-XRF, μ-XAS, and μ-XRD are suitable for such studies.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.435
Times cited: 46
DOI: 10.1146/ANNUREV-ANCHEM-062012-092702
|
|
|
“Electric field gradient calculations in ZnO samples implanted with 111In(111Cd)”. Abreu Y, Cruz CM, van Espen P, Pérez C, Piñera I, Leyva A, Cabal AE, Solid state communications 152, 399 (2012). http://doi.org/10.1016/J.SSC.2011.12.001
Abstract: A first-principles study of the electric field gradient (EFG) calculated for ideal and In-111(Cd-111) implanted ZnO samples is reported in the present work. The study was made for ZnO ideal hexagonal structures and supercells were introduced in order to consider the possible implantation environments. The calculation was done using the “WIEN2k” code within the density functional theory, the exchange and correlation effects were determined by the GGA approximation. Three possible In-111(Cd-111) implantation configurations were studied, one substitutional incorporation at cation site and two interstitials. The obtained EFG values for the ideal structure and the substitutional site are in good agreement with the experimental reports measured by perturbed angular correlation (PAC) and high precision nuclear magnetic resonance (NMR). Thus, the ascription of substitutional incorporation of In-111(Cd-111) probe atom at the ZnO cation site after annealing was confirmed. (C) 2011 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SSC.2011.12.001
|
|
|
“Pixe analysis of aerosol samples collected over the atlantic-ocean from a sailboat”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester WJ, Nuclear instruments and methods 181, 399 (1981). http://doi.org/10.1016/0029-554X(81)90640-6
Abstract: Size-fractionated aerosol samples, collected over the Atlantic Ocean, were analyzed for up to 20 elements by PIXE. Using a sailboat as sampling platform, duplicate samples were taken for two-day periods by means of battery operated 6-stage cascade impactors, positioned about 8 m above the sea surface. In the PIXE analysis of the fine particle stages (stages 3 to 5) a 5 times smaller beam size was used than for stages 1 and 2. This led to significant improvement in the detection limits for the former stages. The results from the duplicate impactor samples were normally in good agreement, indicating that the combined uncertainty of sampling and PIXE analysis was of the order of 20%. The precision of the PIXE analysis alone was investigated by rebombarding some samples six months after the first analysis. The trends with time of the fine particle sulfur and the coarse particle iron concentrations are discussed in some detail.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0029-554X(81)90640-6
|
|
|
“Reduction of trace metal levels in analytical-grade activated carbon”. Vanderborght B, Van Grieken R, Analytica chimica acta 89, 399 (1977). http://doi.org/10.1016/S0003-2670(01)84739-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84739-5
|
|
|
“Sedimentation rate of the floodplain sediments of the Yamuna river basin (tributary of the river Ganges, India) by using <tex>210Pb</tex>, and <tex>137Cs</tex>, techniques”. Saxena DP, Joos P, Van Grieken R, Subramanian V, Journal of radioanalytical and nuclear chemistry 251, 399 (2002). http://doi.org/10.1023/A:1014821906600
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1014821906600
|
|
|
“Inorganic mass spectrometry”. Adams F, Gijbels R, Van Grieken R Wiley, Chichester, page 404 p. (1988).
Keywords: ME3 Book as editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Assessment of air quality after the implementation of Compressed Natural Gas (CNG) as fuel in public transport in Delhi, India”. Ravindra K, Wauters E, Tyagi SK, Mor S, Van Grieken R, Environmental monitoring and assessment 115, 405 (2006). http://doi.org/10.1007/S10661-006-7051-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10661-006-7051-5
|
|
|
de Nolf W (2013) Imaging of crystalline phase distributions by means of scanning and tomographic X-ray powder diffraction. 407 p
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The major-element composition of suspended matter in the Zaire river and estuary”. Sholkovitz ER, Van Grieken R, Eisma D, Netherlands journal of sea research 12, 407 (1978). http://doi.org/10.1016/0077-7579(78)90042-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(78)90042-X
|
|
|
“Quantification in XRF analysis of intermediate-thickness samples”. Markowicz AA, Van Grieken RE page 407 (2002).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Understanding the (in)stability of semiconductor pigments by a thermodynamic approach”. Anaf W, Schalm O, Janssens K, De Wael K, Dyes and pigments 113, 409 (2015). http://doi.org/10.1016/J.DYEPIG.2014.09.015
Abstract: Several artists pigments are semiconductors. Some of these materials appear stable over time, whereas others already show remarkable signs of degradation after limited time periods. The (in)stability of these pigments can be understood using a thermodynamic approach. For several pigment-related materials, the thermodynamic oxidation and reduction potential (ϕox and ϕred) were determined and evaluated considering the absolute energy positions of the valence and conduction band edges and the water redox potentials. The positions of ϕox and ϕred can be used in a fast screening of the stability of semiconductor pigments towards photoinduced corrosion in an aqueous/humid environment. This theoretical approach corresponds well with experimental data on pigment permanence and degradation phenomena found in literature.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 3.473
Times cited: 14
DOI: 10.1016/J.DYEPIG.2014.09.015
|
|
|
“Micro X-ray diffraction and fluorescence tomography for the study of multilayered automotive paints”. de Nolf W, Janssens K, Surface and interface analysis 42, 411 (2010). http://doi.org/10.1002/SIA.3125
Abstract: Combined microscopic X-ray fluorescence/microscopic X-ray diffraction (µ-XRF/µ-XRD) tomography is a recently developed method that allows the visualization of the distribution of chemical elements and the associated crystalline phases inside complex, heterogeneous materials of extended thickness (millimeter range) in a nondestructive fashion. In this paper, the accuracy and resolution with which the individual layers in a multilayer stack of automotive paints can be distinguished is evaluated, and some of their properties measured. A paint layer system of eight layers was investigated, in which eight different crystalline substances were identified, each layer consisting of an organic, synthetic resin doped with finely milled inorganic compounds that serve as pigments or to strengthen the layer. In the XRD tomograms, all paint layers could be straightforwardly distinguished and their average thickness calculated. In case the filtered back projection method was used for tomogram reconstruction, a spatial resolution comparable to the microbeam size was obtained indicating no significant reconstruction blurring. When a more robust reconstruction method, such as the maximum-likelihood expectation maximization method, was employed, tomograms showing fewer artifacts were obtained, but with a spatial resolution that was two times worse. In the corresponding XRF tomograms, significant self-absorption distorted the element-specific tomograms corresponding to the low-energy (<7 keV) characteristic radiation and limited their usefulness. It can be concluded that microbeam XRD tomography allows the accurate visualization of the distribution of crystalline phases in multilayered automotive paint materials of millimeter dimensions with sufficient resolution to allow separate characterization of each layer in terms of its crystal-phase composition and thickness.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.132
Times cited: 70
DOI: 10.1002/SIA.3125
|
|
|
“Analysis of indoor gaseous formic and acetic acid, using radial diffusive samplers”. Stranger M, Potgieter-Vermaak S, Sacco P, Quaglio F, Pagani D, Cocheo C, Godoi AFL, Van Grieken R, Environmental monitoring and assessment 149, 411 (2009). http://doi.org/10.1007/S10661-008-0217-6
Abstract: A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 ìg m−3 and 1248 ìg m−3 were determined to be 91.2 ± 3.9 ml min−1 and 111.6 ± 2.8 ml min−1, respectively. The acetic acid sampling rate was independent of the concentration in the range 160 ìg m−31564 ìg m−3, and amounted to 97.3 ± 3.1 ml min−1. Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 321% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 ± 0.07 ìg for formic acid and 1.21 ± 0.14 ìg for acetic acid, and detection limits lower than 0.5 ìg m−3 could be achieved, which is an improvement of 9899% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10661-008-0217-6
|
|
|
“Barite formation in the Southern Ocean water column”. Stroobants N, Dehairs F, Goeyens L, Vanderheijden N, Van Grieken R, Marine chemistry 35, 411 (1991). http://doi.org/10.1016/S0304-4203(09)90033-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0304-4203(09)90033-0
|
|
|
“Specimen preparation”. Injuk J, Van Grieken R, Blank A, Eksperiandova L, Buhrke V page 411 (2006).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
|
|
“X-ray analysis of riverbank sediment of the Tisza (Hungary): identification of particles from a mine pollution event”. Osán J, Kurunczi S, Török S, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 57, 413 (2002). http://doi.org/10.1016/S0584-8547(01)00405-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00405-0
|
|
|
“Trace element composition of Zaire suspended sediments”. Martin J-M, Thomas AJ, Van Grieken RE, Netherlands journal of sea research 12, 414 (1978). http://doi.org/10.1016/0077-7579(78)90043-1
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(78)90043-1
|
|
|
“Complementary analysis of historical glass by scanning electron microscopy with energy dispersive X-ray spectroscopy and laser ablation inductiveley coupled plasma mass spectrometry”. Wagner B, Nowak A, Bulska E, Kunicki-Goldfinger J, Schalm O, Janssens K, schalm, Microchimica acta 162, 415 (2008). http://doi.org/10.1007/S00604-007-0835-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 28
DOI: 10.1007/S00604-007-0835-7
|
|
|
“Quantification problems in light element determination by grazing emission X-ray fluorescence”. Kuczumow A, Claes M, Schmeling M, Van Grieken R, de Gendt S, Journal of analytical atomic spectrometry 15, 415 (2000). http://doi.org/10.1039/A908724I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A908724I
|
|
|
“Combined SEM/EDX and micro-Raman spectroscopy analysis of uranium minerals from a former uranium mine”. Stefaniak EA, Alsecz A, Frost R, Máthé, Z, Sajó, IE, Török S, Worobiec A, Van Grieken R, Journal of hazardous materials 168, 416 (2009). http://doi.org/10.1016/J.JHAZMAT.2009.02.057
Abstract: Samples of the secondary uranium minerals collected in the abandoned uranium mine at Pecs (Hungary) were investigated by two micro-techniques: scanning electron microscopy (SEM/EDX) and micro-Raman spectroscopy (MRS). They were applied to locate U-rich particles and identify the chemical form and oxidation state of the uranium compounds. The most abundant mineral was a K and/or Na uranyl sulphate (zippeite group). U(VI) was also present in the form showing intensive Raman scattering at 860 cm−1 which can be attributed to uranium trioxide. This research has shown the successful application of micro-Raman spectroscopy for the identification of uranyl mineral species on the level of individual particles.
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.JHAZMAT.2009.02.057
|
|
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
|
|
“Efficient separation of acetate and formate by ion chromatography: application to air samples in a cultural heritage environment”. Kontozova-Deutsch V, Krata A, Deutsch F, Bencs L, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 75, 418 (2008). http://doi.org/10.1016/J.TALANTA.2007.11.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.11.025
|
|
|
Janssens KHA, Adams FCV, Rindby A (2000) Microscopic X-ray fluorescence analysis. 419 p
Keywords: MA1 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Dry aerosol deposition over the North Sea estimated from aircraft measurements”. Rojas CM, Otten PM, Van Grieken RE, Laane R page 419 (1991).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Evaluation of energy-dispersive x-ray spectra of low-Z elements from electron-probe microanalysis of individual particles”. Osán J, de Hoog J, van Espen P, Szalóki I, Ro C-U, Van Grieken R, X-ray spectrometry 30, 419 (2001). http://doi.org/10.1002/XRS.523
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.523
|
|
|
“Chemical boundary conditions for the classification of aerosol particles using computer controlled electron probe microanalysis”. Anaf W, Horemans B, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 101, 420 (2012). http://doi.org/10.1016/J.TALANTA.2012.09.051
Abstract: A method for the classification of individual aerosol particles using computer controlled electron probe microanalysis is presented. It is based on chemical boundary conditions (CBC) and enables quick and easy processing of a large set of elemental concentration data (mass%), derived from the X-ray spectra of individual particles. The particles are first classified into five major classes (sea salt related, secondary inorganic, minerals, iron-rich and carbonaceous), after which advanced data mining can be performed by examining the elemental composition of particles within each class into more detail (e.g., by ternary diagrams). The CBC method is validated and evaluated by comparing its results with the output obtained with hierarchical cluster analysis (HCA) for well-known standard particles as well as real aerosol particles collected with a cascade impactor. The CBC method gives reliable results and has a major advantage compared to HCA. CBC is based on boundary conditions that are derived from chemical logical thinking and does not require a translation of a mathematical algorithm output as does HCA. Therefore, the CBC method is more objective and enables comparison between samples without intermediate steps.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 3
DOI: 10.1016/J.TALANTA.2012.09.051
|
|
|
“Investigation of gaseous and particulate air pollutants at the Basilica Saint-Urbain in Troyes, related to the preservation of the medieval stained glass windows”. Kontozova-Deutsch V, Godoi RHM, Worobiec A, Spolnik Z, Krata A, Deutsch F, Van Grieken R, Microchimica acta 162, 425 (2008). http://doi.org/10.1007/S00604-007-0930-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S00604-007-0930-9
|
|
|
“Elemental composition of PM2.5 in Araraquara City (Southeast Brazil) during seasons with and without sugar cane burning”. Silva FS, Godoi RHM, Tauler R, de André, PA, Saldiva PHN, Van Grieken R, de Marchi MRR, Journal of environmental protection 6, 426 (2015). http://doi.org/10.4236/JEP.2015.65041
Abstract: Particulate matter with an aerodynamic diameter below 2.5 μm (PM2.5), present in polluted air, has been associated with a large spectrum of health impairments, mainly because of its deep deposition into the lungs. Araraquara City (Southeast Brazil) is surrounded by sugar-cane plantations, which are burned to facilitate the harvesting; this process causes environmental pollution due to the large amounts of soot that are released into the atmosphere. In this work, the elemental composition of PM2.5 was studied in two scenarios, namely in sugar-cane harvesting (HV) and in non-harvesting (NHV) seasons. The sampling strategy included one campaign in each season. PM2.5 was collected using a dichotomous sampler (10 L·min-1, 24 h) with PTFE filters. Information concerning the bulk elemental concentration was provided by energy-dispersive X-ray fluorescence. Enrichment factor analysis indicated that S, Cl, K, Cr, Ni, Cu, Zn, As, Cd and Pb were highly enriched relative to their crustal ratios (to Al). Principal component analysis was used to get some insight about the sources of the elements. Principal component 1 (PC1) explained 30.5% of data variance. The elements that had high loading (>0.7) were: S, Cr, As, and Pb; these are associated with combustion of fossil fuels. In principal component 2 (PC2), Cl, Cu, Zn, and Cd showed high loadings; these elements are associated with biomass burning. The Ni concentration found is three times larger than the threshold of risk for lung cancer, as recommended by the World Health Organization.
Keywords: A2 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.4236/JEP.2015.65041
|
|