van de Vijver FL, Verbueken AH, Van Grieken RE, de Broe ME, Visser WJ (1985) Laser microprobe mass analysis : a tool for evaluating histochemical staining of trace elements. 351–352
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Interpretation of aerosol trace metal particle size distributions”. Johansson TB, Van Grieken RE, Winchester JW page 356 (1975).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Detection limits of grazing-exit EPMA for particle analysis”. Tsuji K, Spolnik Z, Wagatsuma K, Nullens R, Van Grieken RE, Microchimica acta 132, 357 (2000). http://doi.org/10.1007/S006040050080
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040050080
|
“Comparison of 3 dry deposition models applied to field-measurements in the Southern Bight of the North-Sea”. Rojas CM, Van Grieken RE, Laane RW, Atmospheric environment 27, 363 (1993). http://doi.org/10.1016/0960-1686(93)90110-K
Abstract: Dry deposition velocities have been calculated using three different approaches. Turbulent wind profile theory has been used to predict the drag coefficient, wind speed and friction velocity at 10 m height when the wind speed is measured at a higher altitude. The resulting parameters were introduced in a two-layer deposition model. The second approach was the well-known model of Slinn and Slinn (1980, Atmospheric Environment 14, 1013-1016), whereas the third corresponded to the model published by Williams (1982, Atmospheric Environment 16, 1933 1938). Results point to clear differences. However, in a field experiment carried out at the Southern Bight of the North Sea, all three approaches show relatively comparable results. The role played by the size distribution of atmospheric particulate matter is essential. In our case any of the three models could have given satisfactory outcomes taking into account the wide spread of the experimental results cited in the literature for the same airshed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90110-K
|
“Laser microprobe mass analysis (LAMMA) in nephrological investigations”. Verbueken AH, Van de Vyver FL, Paulus GJ, Visser WJ, Verpooten GA, de Broe ME, Van Grieken RE page 375 (1984).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Analysis of X-ray spectra excited by X rays, electrons, and protons in monazite”. Annegarn HJ, Madiba CCP, Sellschop JPF, Genz H, Hoffmann DHH, Low W, Richter A, Van Grieken RE, Physical review : C : nuclear physics 16, 379 (1977). http://doi.org/10.1103/PHYSREVC.16.379
Abstract: Mineral monazite from Malaysia has been investigated by energy dispersive x-ray analysis employing three different methods: x-ray, relativistic electron and proton induced excitation. An upper limit of 15 ppm has been placed on the possible concentration of the superheavy element with Z=126.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1103/PHYSREVC.16.379
|
“Trace metals in the St-Louis aerosol”. Winchester JW, Meinert DL, Nelson JW, Johansson TB, Van Grieken RE, Orsini C, Kaufmann HC, Akselsson R page 385 (1975).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Quantification in XRF analysis of intermediate-thickness samples”. Markowicz AA, Van Grieken RE page 407 (2002).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace element composition of Zaire suspended sediments”. Martin J-M, Thomas AJ, Van Grieken RE, Netherlands journal of sea research 12, 414 (1978). http://doi.org/10.1016/0077-7579(78)90043-1
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(78)90043-1
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
“Dry aerosol deposition over the North Sea estimated from aircraft measurements”. Rojas CM, Otten PM, Van Grieken RE, Laane R page 419 (1991).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Laser microprobe mass analysis : a review of applications in the life sciences”. Verbueken AH, Bruynseels FJ, Van Grieken RE, Biomedical mass spectrometry 12, 438 (1985). http://doi.org/10.1002/BMS.1200120903
Abstract: The characteristics and analytical utility of laser microprobe mass analysis (LAMMA) are described and evaluated, and a short history of this recent microanalytical technique is presented. A review of the areas of application of LAMMA and related laser microprobes is presented with special emphasis on applications in the life sciences.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200120903
|
“Laser microprobe mass analysis (LAMMA) of parathyroid glands from dialysis patients”. Verbueken AH, Van de Vyver FL, Nouwen EJ, Roels F, de Broe ME, Van Grieken RE page 443 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
“Classification of estuarine particles using automated electron-microprobe analysis and multivariate techniques”. Bernard PC, Van Grieken RE, Eisma D, Environmental science and technology 20, 467 (1986). http://doi.org/10.1021/ES00147A005
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00147A005
|
“X-ray spectrometry”. Török SB, Labar J, Injuk J, Van Grieken RE, Analytical chemistry R68, 467 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Composition of individual aerosol particles in the marine boundary layer over seas of the Western Russian Arctic”. Shevchenko VP, Van Grieken RE, van Malderen H, Lisitzin AP, Kuptsov VM, Serova VV, Doklady earth sciences 366, 546 (1999)
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Doped albumin : stndardization possibilities for LAMMA-analysis of thin freeze-dried cryosections of biological tissue”. Verbueken AH, Jacob WA, Frederik PM, Busing WM, Hersten RC, Van Grieken RE, Journal de physique 45, 561 (1984)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Geophysical applicability of aerosol size distribution measurements using cascade impactors and proton-induced X-ray-emission”. Van Grieken RE, Johansson TB, Akselsson KR, Winchester JW, Nelson JW, Chapman KR, Atmospheric environment : an international journal 10, 571 (1976). http://doi.org/10.1016/0004-6981(76)90040-8
Abstract: Proton Induced X-ray Emission, (PIXE), is capable of high precision analysis for trace element components of aerosol particle size fractions sampled by cascade impactor. A statistical evaluation of data quality has been carried out in order to distinguish between analytical uncertainties in the PIXE procedure, errors caused by cascade impactor performance and by other factors in the sampling procedure, and geophysical causes of differences in composition and particle size distributions of the elements in aerosols. Replicate analyses and simultaneous samplings taken in north Florida and St. Louis have been used for the data evaluation. In addition to the analytical error the sampling procedure contributes an error of ~ 10% to be added quadratically. The resulting precision is sufficient to evaluate the data in geophysical terms. This is illustrated by means of sample sets taken simultaneously in an urban, forest and coastal environment of the same region.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(76)90040-8
|
“Laser microprobe mass spectrometric identification of cyclosporine-induced intrarenal microliths in rat”. Verbueken AH, Van Grieken RE, Verpooten GA, de Broe ME, Wedeen RP, Biological mass spectrometry 21, 590 (1992). http://doi.org/10.1002/BMS.1200211111
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200211111
|
“Ultrastructural localization of aluminium in liver of aluminium maltol-treated rabbits by laser microprobe mass analysis”. Vandeputte D, Van Grieken RE, Jacob WA, Savory J, Bertholf RL, Wills MR, Biomedical and environmental mass spectrometry 18, 598 (1989). http://doi.org/10.1002/BMS.1200180815
Abstract: By means of laser microprobe mass analysis (LAMMA), we have studied the ultrastructural localization of aluminium in livers of aluminium maltol-treated rabbits. This animal model was developed to study long-term aluminium toxicity using systemic (intravenous) administration of aluminium. We could only detect aluminium in electron-dense inclusion bodies found in large, sometimes multinucleated cells. These results prove that the actual observation of aluminium deposits in liver with LAMMA gives more information than bulk analysis and can be very useful to explore mechanisms of toxicity.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200180815
|
“Atmospheric particles”. Harrison RM, Van Grieken RE page 610 p. (1998).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace metal fractionation effects between sea water and aerosols from bubble bursting”. Van Grieken RE, Johansson TB, Winchester JW, Journal de recherches atmosphériques 8, 611 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Laser microprobe mass analysis (LAMMA) to study lead intoxication at the subcellular level”. Vandeputte DF, Verbueken AH, Jacob WA, Van Grieken RE, Acta pharmacologica et toxicologica 59, 617 (1986). http://doi.org/10.1111/J.1600-0773.1986.TB02840.X
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0773.1986.TB02840.X
|
“Elemental analysis of aerosols using proton-scattering”. Nelson JW, Williams I, Johansson TB, Van Grieken RE, IEEE transactions on nuclear science Ns21, 618 (1974). http://doi.org/10.1109/TNS.1974.4327522
Abstract: Elemental analysis for all of the light elements up through chlorine by elastic scattering of 16 MeV protons has been shown to be feasible. Basic problems associated with such measurements are discussed including kinematics, angular distribution, and sample backings. Spectra are presented for air particulate matter for both a total filter (Nuclepore) and a size fractionated air impactor (polystyrene backed) sample. The method is absolute, non destructive and can be used in conjunction with proton induced x-ray fluorescence to quantitatively analyze all elements in the same sample in minutes of time.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1109/TNS.1974.4327522
|
“Co-crystallization with 1-(2-pyridylazo)-2-naphthol, and X-ray fluorescence, for trace metal analysis of water”. Vanderstappen MG, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 25, 653 (1978). http://doi.org/10.1016/0039-9140(78)80166-0
Abstract: Adding 20mg of 1-(2-pyridylazo)-2-naphthol (PAN) to a water sample at 70°, and filtering off the precipitate after cooling, gives efficient preconcentration prior to X-ray fluorescence analysis of water. Up to the capacity of about 100 μeq of PAN used, the trace metal recoveries are around 90% or higher for Cr3+, Mn2+, Ni2+, Cu2+, Zn2+, Hg2+ and Eu3+, and above 70% for many other ions. The recovery yields usually do not vary critically with pH in the neutral pH-range, and are practically independent of the sample salinity, sample volume and trace-metal concentration. Enrichment factors as high as 2 × 105 can be achieved. Counting statistics would then allow detection limits of 0.03 ppM. The blank levels in commercial PAN, however, lead to typical detection limits of about 1 ppm. The coefficient of variation is typically in the 510% range at the 10-ppM level. The accuracy and applicability of the procedure are illustrated by comparative analyses on samples of synthetic solutions, river and drinking water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(78)80166-0
|
“Sample preparation for XRF”. Injuk J, Van Grieken RE page 657 (1992).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Aerosol-soil fractionation for Namib Desert samples”. Eltayeb MAH, Van Grieken RE, Maenhaut W, Annegarn HAJ, Atmospheric environment: part A : general topics 27, 669 (1993). http://doi.org/10.1016/0960-1686(93)90185-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90185-2
|
“Characterization of the spheroliths present in primary atypical bandkeratopathy using laser microprobe mass analysis”. Vandeputte DF, Van Grieken RE, Foets BJJ, Misotten L, Biomedical and environmental mass spectrometry 18, 753 (1989). http://doi.org/10.1002/BMS.1200180918
Abstract: Laser microprobe mass analysis was applied to study the chemical composition of spheroliths in the Bowman's membrane of patients suffering from primary atypical bandkeratopathy. The inclusions appear to consist mainly of calcium phosphate.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200180918
|
“Marine influences on aerosol composition in the coastal zone”. Johansson TB, Van Grieken RE, Winchester JW, Journal de recherches atmosphériques 8, 761 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|