Records |
Links |
|
Author |
Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A. |
|
|
Title |
Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen |
Type |
A1 Journal article |
|
Year |
1973 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
65 |
Issue |
1 |
Pages |
1-17 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
A1973Q019300001 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.513 |
Times cited |
12 |
Open Access |
|
|
|
Notes |
|
Approved |
|
|
|
Call Number |
UA @ lucian @ c:irua:116364 |
Serial |
3465 |
|
Permanent link to this record |
|
|
|
|
Author |
Johansson, T.B.; Nelson, J.W.; Van Grieken, R.E.; Winchester, J.W. |
|
|
Title |
Elemental analysis of aerosol-size fractions by proton-induced X-ray-emission |
Type |
A1 Journal article |
|
Year |
1973 |
Publication |
Transactions of the American Nuclear Society |
Abbreviated Journal |
|
|
|
Volume |
17 |
Issue |
Nov |
Pages |
103-103 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1973R161300114 |
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-018x |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:113643 |
Serial |
7880 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R. |
|
|
Title |
Analyse van ferro-metalen door activering met 14 MeV neutronen |
Type |
MA3 Book as author |
|
Year |
1973 |
Publication |
|
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
128 p. |
|
|
Keywords |
MA3 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:117470 |
Serial |
7440 |
|
Permanent link to this record |
|
|
|
|
Author |
Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A. |
|
|
Title |
Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects |
Type |
A1 Journal article |
|
Year |
1973 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
64 |
Issue |
2 |
Pages |
187-196 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
A1973P353000003 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.513 |
Times cited |
11 |
Open Access |
|
|
|
Notes |
|
Approved |
CHEMISTRY, PHYSICAL 54/144 Q2 # PHYSICS, ATOMIC, MOLECULAR & CHEMICAL 9/35 Q2 # |
|
|
Call Number |
UA @ lucian @ c:irua:116363 |
Serial |
3464 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R.; Speecke, A.; Hoste, J. |
|
|
Title |
Geometry errors in 14 MeV neutron activation analysis |
Type |
A3 Journal article |
|
Year |
1973 |
Publication |
Journal of radioanalytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
13 |
Issue |
1 |
Pages |
225-233 |
|
|
Keywords |
A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The effects of inaccurate sample sizes and sample positioning on 14 MeV neutron activation analysis results are estimated for 30, 20 and 10 mm diameter targets. It appears that axial positioning is the most critical parameter and that using a larger tritium target will yield an overall improvement of the reproducibility. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2006-10-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0134-0719; 2064-2857 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116453 |
Serial |
7999 |
|
Permanent link to this record |
|
|
|
|
Author |
Gijbels, R.; Dams, R. |
|
|
Title |
Determination of silicon in natural and pollution aerosols by 14-MeV neutron activation analysis |
Type |
A1 Journal article |
|
Year |
1973 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
63 |
Issue |
2 |
Pages |
369-381 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
|
|
Abstract |
The determination of silicon via the 28Si(n,p)28 Al reaction by means of 14-MeV neutrons is applied to the analysis of pollution and natural aerosols. A Whatman 41 filter (40 cm2) on which airborne particulate material has been collected is compressed into a 3 × 12.7 mm pellet. Standards are prepared in the same way from clean filters spiked with a silicate solution. After a 50-s irradiation and a 75-s decay time, the sample is counted for 2 min with 5 × 5 NaI(Tl) well detector. The 1.779-MeV photopeak of 28Al is measured with a single channel sealer chain or with a multichannel analyser. The reproducibility, sensitivity and liability to interference from other elements were investigated for both counting systems. The homogeneity of the pellets and the filters was checked. The overall precision of one single-channel determination was estimated to be 3.5% after a 24-h high-volume sampling time. Samples collected in urban, industrial and remote areas with concentrations ranging from 0.05 to 15 μg Si m-3 air were analysed and the results are discussed. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
A1973O944700013 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.513 |
Times cited |
16 |
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ lucian @ c:irua:116365 |
Serial |
672 |
|
Permanent link to this record |