|
“Absorption correction in electron probe x-ray microanalysis of thin samples”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 58, 1282 (1986). http://doi.org/10.1021/AC00298A003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00298A003
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 58, 279r (1986). http://doi.org/10.1021/AC00296A019
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00296A019
|
|
|
“Enhancement effect in X-ray fluorescence analysis of environmental samples of medium thickness”. Van Dyck PM, Török SB, Van Grieken RE, Analytical chemistry 58, 1761 (1986). http://doi.org/10.1021/AC00121A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00121A036
|
|
|
“Laser microprobe mass spectrometric identification of sulfur species in single micrometer-size particles”. Bruynseels FJ, Van Grieken RE, Analytical chemistry 56, 871 (1984). http://doi.org/10.1021/AC00270A004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00270A004
|
|
|
“Embedded ion exchange beads as standards for laser microprobe mass analysis of biological specimens”. Verbueken AH, Van Grieken RE, Paulus GJ, De Bruijn WC, Analytical chemistry 56, 1362 (1984). http://doi.org/10.1021/AC00272A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00272A036
|
|
|
“Atomic number correction in electron probe X-ray microanalysis of curved samples and particles”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2798 (1984). http://doi.org/10.1021/AC00278A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00278A036
|
|
|
“Composition dependence of Bremsstrahlung background in electron-probe x-ray microanalysis”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2049 (1984). http://doi.org/10.1021/AC00276A016
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00276A016
|
|
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“Absorption correction via scattered radiation in energy-dispersive X-ray fluorescence analysis for samples of variable composition and thickness”. Van Dyck PM, Van Grieken RE, Analytical chemistry 52, 1859 (1980). http://doi.org/10.1021/AC50062A020
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50062A020
|
|
|
“Characterization of a 2,2'-diaminodiethylamine-cellulose filter toward metal cation extraction”. Smits JA, Van Grieken RE, Analytical chemistry 52, 1479 (1980). http://doi.org/10.1021/AC50059A022
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50059A022
|
|
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
|
|
“Enrichment of trace metals in water by adsorption on activated carbon”. Vanderborght BM, Van Grieken RE, Analytical chemistry 49, 311 (1977)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Geometry errors in 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 13, 225 (1973). http://doi.org/10.1007/BF02514126
Abstract: The effects of inaccurate sample sizes and sample positioning on 14 MeV neutron activation analysis results are estimated for 30, 20 and 10 mm diameter targets. It appears that axial positioning is the most critical parameter and that using a larger tritium target will yield an overall improvement of the reproducibility.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02514126
|
|
|
“Spatial neutron flux distributions around A 14 MeV neutron generator”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 10, 95 (1972). http://doi.org/10.1007/BF02518771
Abstract: The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02518771
|
|
|
“The half-life of 28Al”. Van Schandevijl R, Van Grieken R, Hoste J, Journal of radioanalytical chemistry 9, 55 (1971). http://doi.org/10.1007/BF02514012
Abstract: The half-life of28Al was redetermined on aluminium samples of different origin. Three different counting techniques were applied. The availability of highly purified samples (up to 99.9999%), the use of very fast electronic counting equipment and a complete automatisation allowed a good precision to be obtained in the final result of 2.2405 min.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02514012
|
|
|
“Simultaneous determination of silicon and phosphorus in cast iron by 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 6, 385 (1970). http://doi.org/10.1007/BF02513966
Abstract: A fast (10 min), non-destructive simultaneous determination of silicon and phosphorus in cast iron and steel by 14 MeV neutron activation was developed. The 1.78 MeV28Al activity (T=2.24 min) induced by the reaction28Si(n, p)28Al is counted on a NaI(Tl) detector. Two measurements are made to correct for the 1.81 MeV56Mn activity (T=2.58 hr) from the iron matrix. However,28Al is also produced via31P(n, α)28Al. By (n, 2n) reaction, phosphorus yields also30P (T=2.6 min), the 0.511 MeV annihilation radiation of which is counted by two opposite NaI(Tl) detectors in coincidence. Again, two successive coincidence measurements are carried out in order to take into account the53Fe activity (β+; T=8.9 min) from54Fe(n, 2n)53Fe. The28Al measurement is appropriately corrected via the computed phosphorus content. An oxygen flux monitor was used to normalize to the same flux. Nuclear interferences have been examined. Special attention has been paid to the presence of copper. The standard deviation for phosphorus being as high as ca. 0.09% P for a single determination, this technique can only be practical as an independent phosphorus analysis for high phosphorus cast irons. The precision on the28Al measurement is 5% relative for 0.2% Si and 2.5% above 1% Si.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02513966
|
|
|
“Absorption correction for X-ray-fluorescence analysis of aerosol loaded filters”. Adams FC, Van Grieken RE, Analytical chemistry 47, 1767 (1975). http://doi.org/10.1021/AC60361A040
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60361A040
|
|
|
“Elemental trace analysis of small samples by proton-induced X-ray-emission”. Johansson TB, Van Grieken RE, Nelson JW, Winchester JW, Analytical chemistry 47, 855 (1975). http://doi.org/10.1021/AC60356A035
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60356A035
|
|
|
“Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water”. Van Grieken RE, Bresseleers CM, Vanderborght BM, Analytical chemistry 49, 1326 (1977). http://doi.org/10.1021/AC50017A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50017A011
|
|
|
“Spark-source mass-spectrometric sensitivity factors for elements in a graphite matrix”. Vanderborght B, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 26, 461 (1979). http://doi.org/10.1016/0039-9140(79)80111-3
Abstract: Relative sensitivity factors for determination of 41 elements by spark-source mass-spectrometry have been measured. The samples were pressed into graphite electrodes and ionized with a radiofrequency spark. The mass spectra were recorded on a photoplate and the resulting data processed by a computer. Indium was used as standard and the relative sensitivity factors for both singly- and doubly-charged ions were determined with reference to the singly-charged indium ion, with an overall error of 30%. The mean analysis precision was 16%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(79)80111-3
|
|
|
“Selenium in environmental waters : determination, speciation and concentration levels”. Robberecht H, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 29, 823 (1982). http://doi.org/10.1016/0039-9140(82)80252-X
Abstract: This article reviews the different methods used for the determination of selenium species in all types of environmental waters. Basic difficulties are discussed and the efficiency of the methods is explained in view of the sub-μg/1. concentration levels. Special attention is paid to preconcentration steps. Published data on speciation and concentration levels in various water samples are critically reviewed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80252-X
|
|
|
“Bremsstrahlung background in electron-probe X-ray-microanalysis of thin films”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 57, 2885 (1985). http://doi.org/10.1021/AC00291A032
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00291A032
|
|
|
“Effective sample weight from scatter peaks in energy-dispersive x-ray fluorescence”. van Espen P, Van 't dack L, Adams F, Van Grieken R, Analytical chemistry 51, 961 (1979). http://doi.org/10.1021/AC50043A042
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1021/AC50043A042
|
|
|
“The use of synchrotron radiation for the characterization of artists' pigments and paintings”. Janssens K, Alfeld M, van der Snickt G, de Nolf W, Vanmeert F, Radepont M, Monico L, et al, Annual review of analytical chemistry 6, 399 (2013). http://doi.org/10.1146/ANNUREV-ANCHEM-062012-092702
Abstract: We review methods and recent studies in which macroscopic to (sub)microscopic X-ray beams were used for nondestructive analysis and characterization of pigments, paint microsamples, and/or entire paintings. We discuss the use of portable laboratory- and synchrotron-based instrumentation and describe several variants of X-ray fluorescence (XRF) analysis used for elemental analysis and imaging and combined with X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Macroscopic and microscopic (μ-)XRF variants of this method are suitable for visualizing the elemental distribution of key elements in paint multilayers. Technical innovations such as multielement, large-area XRF detectors have enabled such developments. The use of methods limited to elemental analysis or imaging usually is not sufficient to elucidate the chemical transformations that take place during natural pigment alteration processes. However, synchrotron-based combinations of μ-XRF, μ-XAS, and μ-XRD are suitable for such studies.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.435
Times cited: 46
DOI: 10.1146/ANNUREV-ANCHEM-062012-092702
|
|
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of spectromicroscopic methods : 4 : artificial aging of model samples of co-precipitates of lead chromate and lead sulfate”. Monico L, Janssens K, Miliani C, van der Snickt G, Brunetti BG, Guidi MC, Radepont M, Cotte M, Analytical chemistry 85, 860 (2013). http://doi.org/10.1021/AC3021592
Abstract: Previous investigations about the darkening of chrome yellow pigments revealed that this form of alteration is attributable to a reduction of the original Cr(VI) to Cr(III), and that the presence of sulfur-containing compounds, most often sulfates, plays a key role during this process. We recently demonstrated that different crystal forms of chrome yellow pigments (PbCrO4 and PbCr1xSxO4) are present in paintings by Vincent van Gogh. In the present work, we show how both the chemical composition and the crystalline structure of lead chromate-based pigments influence their stability. For this purpose, oil model samples made with in-house synthesized powders of PbCrO4 and PbCr1xSxO4 were artificially aged and characterized. We observed a profound darkening only for those paint models made with PbCr1xSxO4, rich in SO42 (x ≥ 0.4), and orthorhombic phases (>30 wt %). Cr and S K-edge micro X-ray absorption near edge structure investigations revealed in an unequivocal manner the formation of up to about 60% of Cr(III)-species in the outer layer of the most altered samples; conversely, independent of the paint models chemical composition, no change in the S-oxidation state was observed. Analyses employing UVvisible diffuse reflectance and Fourier transform infrared spectroscopy were performed on unaged and aged model samples in order to obtain additional information on the physicochemical changes induced by the aging treatment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 49
DOI: 10.1021/AC3021592
|
|
|
“Concentration profiles of metal contaminants in fluvial sediments of a rural-urban drainage basin in Tanzania”. Hellar-Kihampa H, Potgieter-Vermaak S, De Wael K, Lugwisha E, van Espen P, Van Grieken R, International journal of environmental analytical chemistry 94, 77 (2014). http://doi.org/10.1080/03067319.2013.791976
Abstract: This study investigated concentration profiles of trace, rare earth and platinum group metals in fluvial sediments from the Pangani river basin (43,650 km2), one of the largest river basins in Tanzania, to assess its environmental quality. Sediment samples were collected in two distinct seasons from 12 representative sites of diverse land-use practices and characterised by ICP-MS after optimised microwave digestion. Ecological risks were assessed by evaluation of pollution index and comparison with legislated sediment quality guidelines (SQG). The results revealed contamination by some trace metals (e.g. Pb, V, Cu, Cr, Ni, Cd, As, Co, Mn and Zn) in concentrations ranging from 0.7 to 2940 mg kg−1, and four rare earth elements (Y, Ce, Nd, Yb) in concentrations ranging from 0.9 (Yb) to 500 mg kg−1 dry weight (Ce), which significantly exceeded the estimated background values at some stations. Palladium was the only platinum group element that was detected in quantifiable concentrations (0.33.5 mg kg−1). Concentrations of some trace metals exceeded the SQGs at some localised areas. Principal component analysis and multivariate correlations indicated geochemical characteristics of the area as the major control of metal concentrations and spatial variability. Organic matter and clay contents also played a significant role in metal distributions. Assessment of land-use practices upstream of the sampling locations was used to trace potential anthropogenic sources of metal enrichments, where highest levels were found in areas close to urban centres and agricultural activities. The study provides baseline data for future monitoring programs, and highlights the need for more comprehensive analysis involving a wider spatio-temporal scale and ecotoxicological risk assessment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.208
Times cited: 5
DOI: 10.1080/03067319.2013.791976
|
|
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of spectromicroscopic methods : 3 : synthesis, characterization, and detection of different crystal forms of the chrome yellow pigment”. Monico L, Janssens K, Miliani C, Brunetti BG, Vagnini M, Vanmeert F, Falkenberg G, Abakumov A, Lu Y, Tian H, Verbeeck J, Radepont M, Cotte M, Hendriks E, Geldof M, van der Loeff L, Salvant J, Menu M;, Analytical chemistry 85, 860 (2013). http://doi.org/10.1021/ac302158b
Abstract: The painter, Vincent van Gogh, and some of his contemporaries frequently made use of the pigment chrome yellow that is known to show a tendency toward darkening. This pigment may correspond to various chemical compounds such as PbCrO4 and PbCr1-xSxO4, that may each be present in various crystallographic forms with different tendencies toward degradation. Investigations by X-ray diffraction (XRD), mid-Fourier Transform infrared (FTIR), and Raman instruments (benchtop and portable) and synchrotron radiation-based micro-XRD and X-ray absorption near edge structure spectroscopy performed on oil-paint models, prepared with in-house synthesized PbCrO4 and PbCr1-xSxO4, permitted us to characterize the spectroscopic features of the various forms. On the basis of these results, an extended study has been carried out on historic paint tubes and on embedded paint microsamples taken from yellow-orange/pale yellow areas of 12 Van Gogh paintings, demonstrating that Van Gogh effectively made use of different chrome yellow types. This conclusion was also confirmed by in situ mid-FTIR investigations on Van Goghs Portrait of Gauguin (Van Gogh Museum, Amsterdam).
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 79
DOI: 10.1021/ac302158b
|
|
|
“Spatially resolved (semi)quantitative determination of iron (Fe) in plants by means of synchrotron micro X-ray fluorescence”. Terzano R, Alfeld M, Janssens K, Vekemans B, Schoonjans T, Vincze L, Tomasi N, Pinton R, Cesco S, Analytical and bioanalytical chemistry 405, 3341 (2013). http://doi.org/10.1007/S00216-013-6768-6
Abstract: Iron (Fe) is an essential element for plant growth and development; hence determining Fe distribution and concentration inside plant organs at the microscopic level is of great relevance to better understand its metabolism and bioavailability through the food chain. Among the available microanalytical techniques, synchrotron mu-XRF methods can provide a powerful and versatile array of analytical tools to study Fe distribution within plant samples. In the last years, the implementation of new algorithms and detection technologies has opened the way to more accurate (semi)quantitative analyses of complex matrices like plant materials. In this paper, for the first time the distribution of Fe within tomato roots has been imaged and quantified by means of confocal mu-XRF and exploiting a recently developed fundamental parameter-based algorithm. With this approach, Fe concentrations ranging from few hundreds of ppb to several hundreds of ppm can be determined at the microscopic level without cutting sections. Furthermore, Fe (semi)quantitative distribution maps were obtained for the first time by using two opposing detectors to collect simultaneously the XRF radiation emerging from both sides of an intact cucumber leaf.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 27
DOI: 10.1007/S00216-013-6768-6
|
|
|
“Combined use of synchrotron radiation based micro-X-ray fluorescence, micro-X-ray diffraction, micro-X-ray absorption near-edge, and micro-fourier transform infrared spectroscopies for revealing an alternative degradation pathway of the pigment cadmium yellow in a painting by Van Gogh”. van der Snickt G, Janssens K, Dik J, de Nolf W, Vanmeert F, Jaroszewicz J, Cotte M, Falkenberg G, Van der Loeff L, Analytical chemistry 84, 10221 (2012). http://doi.org/10.1021/AC3015627
Abstract: Over the past years a number of studies have described the instability of the pigment cadmium yellow (CdS). In a previous paper we have shown how cadmium sulfide on paintings by James Ensor oxidizes to CdSO4 center dot H2O. The degradation process gives rise to the fading of the bright yellow color and the formation of disfiguring white crystals that are present on the paint surface in approximately 50 mu m sized globular agglomerations. Here, we study cadmium yellow in the painting “Flowers in a blue vase” by Vincent van Gogh. This painting differs from the Ensor case in the fact that (a) a varnish was superimposed onto the degraded paint surface and (b) the CdS paint area is entirely covered with an opaque crust. The latter obscures the yellow color completely and thus presents a seemingly more advanced state of degradation. Analysis of a cross-sectioned and a crushed sample by combining scanning microscopic X-ray diffraction (mu-XRD), microscopic X-ray absorption near-edge spectroscopy (mu-XANES), microscopic X-ray fluorescence (mu-XRF) based chemical state mapping and scanning microscopic Fourier transform infrared (mu-FT-IR) spectrometry allowed unravelling the complex alteration pathway. Although no crystalline CdSO4 compounds were identified on the Van Gogh paint samples, we conclude that the observed degradation was initially caused by oxidation of the original CdS pigment, similar as for the previous Ensor case. However, due to the presence of an overlying varnish containing lead-based driers and oxalate ions, secondary reactions took place. In particular, it appears that upon the photoinduced oxidation of its sulfidic counterion, the Cd2+ ions reprecipitated at the paint/varnish interface after having formed a complex with oxalate ions that themselves are considered to be degradation products of the resin and/or oil in the varnish. The SO42- anions, for their part, found a suitable reaction partner in Pb2+ ions stemming from a dissolved lead-based siccative that was added to the varnish to promote its drying. The resulting opaque anglesite compound in the varnish, in combination with the underlying CdC2O4 layer at the paint/varnish interface, account for the orange-gray crust that is disfiguring the painting on a macroscopic level. In this way, the results presented in this paper demonstrate how, through a judicious combined use of several microanalytical methods with speciation capabilities, many new insights can be obtained from two minute, but highly complex and heterogeneous paint samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 59
DOI: 10.1021/AC3015627
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 85, 670 (2013). http://doi.org/10.1021/ac3031459
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 29
DOI: 10.1021/ac3031459
|
|