|
“Nanoparticle growth and transport mechanisms in capacitively coupled silane discharges: a numerical investigation”. de Bleecker K, Bogaerts A, Goedheer WJ, , 201 (2005)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Glow discharges in emission and mass spectrometry”. Jakubowski N, Bogaerts A, Hoffmann V Blackwell, Sheffield (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“One-dimensional modelling of a capacitively coupled rf plasma in silane/helium, including small concentrations of O2 and N2”. de Bleecker K, Herrebout D, Bogaerts A, Gijbels R, Descamps P, Journal of physics: D: applied physics 36, 1826 (2003)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
|
|
“Modeling network for argon glow discharge plasmas with copper cathode”. Bogaerts A, Gijbels R Nova, New York, page 1 (2002).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Analysis of nonconducting materials by dc glow discharge spectrometry”. Bogaerts A, Schelles W, van Grieken R Wiley, Chichester, page 293 (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
“Numerical modelling of analytical glow discharges”. Bogaerts A, Gijbels R Wiley, Chichester, page 155 (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Modeling of magnetron and glow discharges”. Bogaerts A, Kolev I, Le vide: science, technique et applications 57, 296 (2002)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Interactions between DC plasma and HF fields”. Cenian A, Chernukho A, Leys C, Bogaerts A, , 389 (2001)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Modeling network for argon glow discharges: the output cannot be better than the input”. Bogaerts A, Gijbels R American Institute of Physics, Melville, N.Y., page 49 (2000).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 1
|
|
“Modeling of radio-frequency and direct current glow discharges in argon”. Bogaerts A, Gijbels R, Journal of technical physics 41, 183 (2000)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Glow discharge mass spectrometry, methods”. Bogaerts A Academic Press, San Diego, Calif., page 669 (2000).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Investigation of the electron distribution functions in low pressure electron cyclotron resonance discharges”. Kaganovich I, Misina M, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 543 (1999).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Modelling of radio frequency capacitively coupled plasma at intermediate pressures”. Berezhnoi S, Kaganovich I, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 525 (1999).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Comprehensive three-dimensional modeling network for a dc glow discharge plasma”. Bogaerts A, Gijbels R, Plasma physics reports 24, 573 (1998)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 0.984
Times cited: 8
|
|
“Modeling of glow discharges: what can we learn from it?”.Bogaerts A, Gijbels R, Analytical chemistry A-pages 69, 719 (1997)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Plasma models”. Bogaerts A, Gijbels R Wiley, New York, page 176 (1997).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Computer simulation of an analytical direct current glow discharge in argon: influence of the cell dimensions on the plasma quantities”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 12, 751 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
|
|
“Calculation of crater profiles on a flat cathode in a direct current glow discharge, and comparison with experiment”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 52, 765 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 42
|
|
“Comparison of argon and neon as discharge gases in a direct current glow discharge: a mathematical simulation”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 52, 553 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 13
|
|
“Modeling of glow discharge ion sources for mass spectrometry: potentials and limitations”. Gijbels R, Bogaerts A, Spectroscopy 9, 8 (1997)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Three-dimensional density profiles of the argon metastable atoms in a direct current glow discharge: experimental study and comparison with calculations”. Bogaerts A, Guenard RD, Smith BW, Winefordner JD, Harrison WW, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 52, 219 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 36
|
|
“Three-dimensional density profiles of sputtered atoms and ions in a direct current glow discharge: experimental study and comparison with calculations”. Bogaerts A, Wagner E, Smith BW, Winefordner JD, Pollmann D, Harrison WW, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 52, 205 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 46
|
|
Bogaerts A (1996) Mathematical modeling of a direct current glow discharge in argon. Universitaire Instelling Antwerpen, Antwerpen
Keywords: Doctoral thesis; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Recent trends in solids mass spectrometry, with special emphasis on glow discharge mass spectrometry”. Gijbels R, Bogaerts A, , 71 (1996)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Mathematical description of a direct current glow discharge in argon”. Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 355, 853 (1996)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 12
|
|
“Analysis and comparison of the co2 and co dielectric barrier discharge solid products”. Belov I, Paulussen S, Bogaerts A, Hakone Xv: International Symposium On High Pressure Low Temperature Plasma Chemistry: With Joint Cost Td1208 Workshop: Non-equilibrium Plasmas With Liquids For Water And Surface Treatment (2016)
Abstract: The CO and CO2 Dielectric Barrier Discharges (DBD) and their solid products were analyzed keeping similar energy input regimes. Gas chromatography analysis revealed the presence of CO2, CO and O-2 mixture in the exhaust of the CO2 DBD, while no O-2 was found when CO was used as a feed gas. It was shown that the C-2 Swan lines observed with optical emission spectroscopy were distinct in the CO plasma while they were not observed in the CO2 emission spectrum. Also the solid products of the plasmas exhibited remarkable differences. Nanoparticles with a diameter between10 and 300 nm, composed of Fe, O and C (Fe: O: C similar to 13: 50: 30) were produced by the CO2 DBD, while microscopic dendrite-like carbon structure (C: O similar to 73: 27) were formed in the CO plasma. The growth rate in the CO2 and CO DBDs was evaluated to be on the level of 0.15 mg/min and 15 mg/min, respectively. The difference of the CO and CO2 discharges and their products might be attributed to the oxygen content in the latter (6.4 mol.% O-2 in the exhaust) and subsequent etching of the carbonaceous film.
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Plasma based co2 conversion: a combined modeling and experimental study”. Bogaerts A, Snoeckx R, Berthelot A, Heijkers S, Wang W, Sun S, Van Laer K, Ramakers M, Michielsen I, Uytdenhouwen Y, Meynen V, Cool P, Hakone Xv: International Symposium On High Pressure Low Temperature Plasma Chemistry: With Joint Cost Td1208 Workshop: Non-equilibrium Plasmas With Liquids For Water And Surface Treatment (2016)
Abstract: In recent years there is increased interest in plasma-based CO2 conversion. Several plasma setups are being investigated for this purpose, but the most commonly used ones are a dielectric barrier discharge (DBD), a microwave (MW) plasma and a gliding arc (GA) reactor. In this proceedings paper, we will show results from our experiments in a (packed bed) DBD reactor and in a vortex-flow GA reactor, as well as from our model calculations for the detailed plasma chemistry in a DBD, MW and GA, for pure CO2 as well as mixtures of CO2 with N-2, CH4 and H2O.
Keywords: P1 Proceeding; Laboratory of adsorption and catalysis (LADCA); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
Bogaerts A, Berthelot A, Heijkers S, Kozá,k T (2015) Computer modeling of a microwave discharge used for CO2 splitting. UCO Press, Cordoba, 41–50
Keywords: P2 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
Berthelot A, Kolev S, Bogaerts A (2015) Different pressure regimes of a surface-wave discharge in argon : a modelling investigation. UCO Press, Cordoba, 57–62
Keywords: P2 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Glow discharge optical spectroscopy and mass spectrometry”. Bogaerts A John Wiley & Sons, Chichester, page 1 (2016).
Abstract: Atomic Spectroscopy Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupole mass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (500–1500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (mostly Ar) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes, and the photons or ions created in this way can be detected with optical emission spectroscopy or mass spectrometry. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. In recent years, there is also increasing interest for using GD sources for liquid and gas analyses. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution and gaseous samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This article focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GD sources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with a variety of spectroscopic and spectrometric instruments for both quantitative and qualitative analyses.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|