|
“Comparison of grazing-exit particle-induced X-ray emission with other related methods”. Tsuji K, Huisman M, Spolnik Z, Wagatsuma K, Mori Y, Van Grieken RE, Vis RD, Spectrochimica acta: part B : atomic spectroscopy 55, 1009 (2000). http://doi.org/10.1016/S0584-8547(00)00148-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(00)00148-8
|
|
|
“Preliminary experiments on grazing-exit electron probe microanalysis (GE-EPMA)”. Tsuji K, Spolnik Z, Wagatsuma K, Nullens R, Van Grieken RE, , 119 (1999)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Detection limits of grazing-exit EPMA for particle analysis”. Tsuji K, Spolnik Z, Wagatsuma K, Nullens R, Van Grieken RE, Microchimica acta 132, 357 (2000). http://doi.org/10.1007/S006040050080
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040050080
|
|
|
“Quantification in grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken RE, de Bokx PK, Urbach HP, Spectrochimica acta: part B : atomic spectroscopy 54, 1525 (1999). http://doi.org/10.1016/S0584-8547(99)00051-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00051-8
|
|
|
“Grazing-exit particle-induced X-ray emission analysis with extremely low background”. Tsuji K, Spolnik Z, Wagatsuma K, Van Grieken RE, Vis RD, Analytical chemistry 71, 5033 (1999). http://doi.org/10.1021/AC990568U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990568U
|
|
|
“Determination of trace elements in organic matrices by grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken R, Analytica chimica acta 401, 293 (1999). http://doi.org/10.1016/S0003-2670(99)00471-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(99)00471-7
|
|
|
“Enhancement of electron-induced X-ray intensity for single particles under grazing-exit conditions”. Tsuji K, Spolnik Z, Wagatsuma K, Zhang J, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1243 (1999). http://doi.org/10.1016/S0584-8547(99)00073-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00073-7
|
|
|
“Effects of IR heating on distribution and transport of gaseous air pollutants in urban and mountain churches in Poland”. Bencs L, Spolnik Z, Worobiec A, Samek L, Jutte BAHG, Van Grieken R, Journal of cultural heritage 36, 200 (2019). http://doi.org/10.1016/J.CULHER.2018.09.007
Abstract: The spatial distribution and temporal concentration variation of a set of gaseous air components (e.g., CO2, CO, H2CO, H2O) have been monitored with a multi-channel photoacoustic gas-analyzer in an urban church ( Saint Catherine's, Cracow) and a mountain church ( Saint Michaels Archangel, Szalowa) of Poland, in order to assess the likely effects of air pollution indoors under the influence of provisory electrical infrared (IR) heaters and without heating. Likewise, the ventilation characteristic and the leakage of these buildings with different constructions (i.e., plastered stone and wooden structures) with the assistance of decay curves of SF6 tracer gas was evaluated and compared. The wooden building in Szalowa, due to its more open structure, developed about one order higher ventilation rates (e.g., 0.9-1.3 h(-1)) than the stone church in Cracow (e.g., 0.1 h(-1)). The IR-heating affected only modestly the ventilation rate of the wooden church (e.g., 1.2-1.6 h(-1)), but it increased significantly that of the plastered stone church (e.g., 0.27 h(-1)). The ventilation rates were also assessed with the use of the CO2 curve decay method, and satisfactory agreement was found with those observed by the use of SF6 tracer. The spatial distribution of the studied gaseous pollutants (CO2, H2O) was found to be in some occasions nonhomogeneous in both buildings, due to the active usage of the IR-heating, especially, during a couple of consecutive liturgical services. Besides the pollution events due to ingress of gaseous air pollutants, present at enhanced levels outdoors, increased CO, CO2 and H2CO peaks were observed indoors too, which, in most cases, could be associated with incense burning. (C) 2018 Elsevier Masson SAS. All rights reserved.
Keywords: A1 Journal article; Art; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.CULHER.2018.09.007
|
|