“Chemical structure of nitrogen-doped graphene with single platinum atoms and atomic clusters as a platform for the PEMFC electrode”. Stambula S, Gauquelin N, Bugnet M, Gorantla S, Turner S, Sun S, Liu J, Zhang G, Sun X, Botton GA, The journal of physical chemistry: C : nanomaterials and interfaces 118, 3890 (2014). http://doi.org/10.1021/jp408979h
Abstract: A platform for producing stabilized Pt atoms and clusters through the combination of an N-doped graphene support and atomic layer deposition (ALD) for the Pt catalysts was investigated using transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM). It was determined, using imaging and spectroscopy techniques, that a wide range of N-dopant types entered the graphene lattice through covalent bonds without largely damaging its structure. Additionally and most notably, Pt atoms and atomic clusters formed in the absence of nanoparticles. This work provides a new strategy for experimentally producing stable atomic and subnanometer cluster catalysts, which can greatly assist the proton exchange membrane fuel cell (PEMFC) development by producing the ultimate surface area to volume ratio catalyst.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 4.536
Times cited: 57
DOI: 10.1021/jp408979h
|
“Gallium oxide nanorods : novel, template-free synthesis and high catalytic activity in epoxidation reactions”. Lueangchaichaweng W, Brooks NR, Fiorilli S, Gobechiya E, Lin K, Li L, Parres-Esclapez S, Javon E, Bals S, Van Tendeloo G, Martens JA, Kirschhock CEA, Jacobs PA, Pescarmona PP;, Angewandte Chemie: international edition in English 53, 1585 (2014). http://doi.org/10.1002/anie.201308384
Abstract: Gallium oxide nanorods with unprecedented small dimensions (20-80nm length and 3-5nm width) were prepared using a novel, template-free synthesis method. This nanomaterial is an excellent heterogeneous catalyst for the sustainable epoxidation of alkenes with H2O2, rivaling the industrial benchmark microporous titanosilicate TS-1 with linear alkenes and being much superior with bulkier substrates. A thorough characterization study elucidated the correlation between the physicochemical properties of the gallium oxide nanorods and their catalytic performance, and underlined the importance of the nanorod morphology for generating a material with high specific surface area and a high number of accessible acid sites.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 11.994
Times cited: 61
DOI: 10.1002/anie.201308384
|
“Reply to Comment on “Frustrated octahedral tilting distortion in the incommensurately modulated Li3xNd2/3-xTiO3 perovskites””. Abakumov AM, Erni R, Tsirlin AA, Chemistry of materials 26, 1288 (2014). http://doi.org/10.1021/cm500005d
Keywords: Editorial; Electron microscopy for materials research (EMAT)
Impact Factor: 9.466
Times cited: 1
DOI: 10.1021/cm500005d
|
“Design of new electrode materials for Li-ion and Na-ion batteries from the bloedite mineral Na2Mg(SO4)2\cdot4H2O”. Reynaud M, Rousse G, Abakumov AM, Sougrati MT, Van Tendeloo G, Chotard J-N, Tarascon J-M, Journal of materials chemistry A : materials for energy and sustainability 2, 2671 (2014). http://doi.org/10.1039/c3ta13648e
Abstract: Mineralogy offers a large database to search for Li- or Na-based compounds having suitable structural features for acting as electrode materials, LiFePO4 being one example. Here we further explore this avenue and report on the electrochemical properties of the bloedite type compounds Na2M(SO4)(2)center dot 4H(2)O (M = Mg, Fe, Co, Ni, Zn) and their dehydrated phases Na2M(SO4)(2) (M = Fe, Co), whose structures have been solved via complementary synchrotron X-ray diffraction, neutron powder diffraction and transmission electron microscopy. Among these compounds, the hydrated and anhydrous iron-based phases show electrochemical activity with the reversible release/uptake of 1 Na+ or 1 Li+ at high voltages of similar to 3.3 V vs. Na+/Na-0 and similar to 3.6 V vs. Li+/Li-0, respectively. Although the reversible capacities remain lower than 100 mA h g(-1), we hope this work will stress further the importance of mineralogy as a source of inspiration for designing eco-efficient electrode materials.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 8.867
Times cited: 56
DOI: 10.1039/c3ta13648e
|
“Electronic properties of graphene nano-flakes : energy gap, permanent dipole, termination effect, and Raman spectroscopy”. Singh SK, Neek-Amal M, Peeters FM, The journal of chemical physics 140, 074304 (2014). http://doi.org/10.1063/1.4865414
Abstract: The electronic properties of graphene nano-flakes (GNFs) with different edge passivation are investigated by using density functional theory. Passivation with F and H atoms is considered: C-Nc X-Nx (X = F or H). We studied GNFs with 10 < N-c < 56 and limit ourselves to the lowest energy configurations. We found that: (i) the energy difference Delta between the highest occupied molecular orbital and the lowest unoccupied molecular orbital decreases with N-c, (ii) topological defects (pentagon and heptagon) break the symmetry of the GNFs and enhance the electric polarization, (iii) the mutual interaction of bilayer GNFs can be understood by dipole-dipole interaction which were found sensitive to the relative orientation of the GNFs, (iv) the permanent dipoles depend on the edge terminated atom, while the energy gap is independent of it, and (v) the presence of heptagon and pentagon defects in the GNFs results in the largest difference between the energy of the spin-up and spin-down electrons which is larger for the H-passivated GNFs as compared to F-passivated GNFs. Our study shows clearly the effect of geometry, size, termination, and bilayer on the electronic properties of small GNFs. This study reveals important features of graphene nano-flakes which can be detected using Raman spectroscopy. (C) 2014 AIP Publishing LLC.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.965
Times cited: 30
DOI: 10.1063/1.4865414
|
“Simultaneous determination of silicon and phosphorus in cast iron by 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 6, 385 (1970). http://doi.org/10.1007/BF02513966
Abstract: A fast (10 min), non-destructive simultaneous determination of silicon and phosphorus in cast iron and steel by 14 MeV neutron activation was developed. The 1.78 MeV28Al activity (T=2.24 min) induced by the reaction28Si(n, p)28Al is counted on a NaI(Tl) detector. Two measurements are made to correct for the 1.81 MeV56Mn activity (T=2.58 hr) from the iron matrix. However,28Al is also produced via31P(n, α)28Al. By (n, 2n) reaction, phosphorus yields also30P (T=2.6 min), the 0.511 MeV annihilation radiation of which is counted by two opposite NaI(Tl) detectors in coincidence. Again, two successive coincidence measurements are carried out in order to take into account the53Fe activity (β+; T=8.9 min) from54Fe(n, 2n)53Fe. The28Al measurement is appropriately corrected via the computed phosphorus content. An oxygen flux monitor was used to normalize to the same flux. Nuclear interferences have been examined. Special attention has been paid to the presence of copper. The standard deviation for phosphorus being as high as ca. 0.09% P for a single determination, this technique can only be practical as an independent phosphorus analysis for high phosphorus cast irons. The precision on the28Al measurement is 5% relative for 0.2% Si and 2.5% above 1% Si.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02513966
|
“The half-life of 28Al”. Van Schandevijl R, Van Grieken R, Hoste J, Journal of radioanalytical chemistry 9, 55 (1971). http://doi.org/10.1007/BF02514012
Abstract: The half-life of28Al was redetermined on aluminium samples of different origin. Three different counting techniques were applied. The availability of highly purified samples (up to 99.9999%), the use of very fast electronic counting equipment and a complete automatisation allowed a good precision to be obtained in the final result of 2.2405 min.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02514012
|
“Spatial neutron flux distributions around A 14 MeV neutron generator”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 10, 95 (1972). http://doi.org/10.1007/BF02518771
Abstract: The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02518771
|
“Geometry errors in 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 13, 225 (1973). http://doi.org/10.1007/BF02514126
Abstract: The effects of inaccurate sample sizes and sample positioning on 14 MeV neutron activation analysis results are estimated for 30, 20 and 10 mm diameter targets. It appears that axial positioning is the most critical parameter and that using a larger tritium target will yield an overall improvement of the reproducibility.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02514126
|
“Enrichment of trace metals in water by adsorption on activated carbon”. Vanderborght BM, Van Grieken RE, Analytical chemistry 49, 311 (1977)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
“Characterization of a 2,2'-diaminodiethylamine-cellulose filter toward metal cation extraction”. Smits JA, Van Grieken RE, Analytical chemistry 52, 1479 (1980). http://doi.org/10.1021/AC50059A022
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50059A022
|
“Absorption correction via scattered radiation in energy-dispersive X-ray fluorescence analysis for samples of variable composition and thickness”. Van Dyck PM, Van Grieken RE, Analytical chemistry 52, 1859 (1980). http://doi.org/10.1021/AC50062A020
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50062A020
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
“Composition dependence of Bremsstrahlung background in electron-probe x-ray microanalysis”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2049 (1984). http://doi.org/10.1021/AC00276A016
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00276A016
|
“Atomic number correction in electron probe X-ray microanalysis of curved samples and particles”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2798 (1984). http://doi.org/10.1021/AC00278A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00278A036
|
“Embedded ion exchange beads as standards for laser microprobe mass analysis of biological specimens”. Verbueken AH, Van Grieken RE, Paulus GJ, De Bruijn WC, Analytical chemistry 56, 1362 (1984). http://doi.org/10.1021/AC00272A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00272A036
|
“Laser microprobe mass spectrometric identification of sulfur species in single micrometer-size particles”. Bruynseels FJ, Van Grieken RE, Analytical chemistry 56, 871 (1984). http://doi.org/10.1021/AC00270A004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00270A004
|
“Enhancement effect in X-ray fluorescence analysis of environmental samples of medium thickness”. Van Dyck PM, Török SB, Van Grieken RE, Analytical chemistry 58, 1761 (1986). http://doi.org/10.1021/AC00121A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00121A036
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 58, 279r (1986). http://doi.org/10.1021/AC00296A019
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00296A019
|
“Absorption correction in electron probe x-ray microanalysis of thin samples”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 58, 1282 (1986). http://doi.org/10.1021/AC00298A003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00298A003
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 60, 28r (1988). http://doi.org/10.1021/AC00163A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00163A002
|
“Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysis”. Wouters LC, Van Grieken RE, Linton RW, Bauer CF, Analytical chemistry 60, 2218 (1988). http://doi.org/10.1021/AC00171A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00171A011
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 62, 101r (1990). http://doi.org/10.1021/AC00211A001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00211A001
|
“Determination of protein-bound copper and zinc in some organs of the cuttlefish Sepia officinalis L”. Decleir W, Vlaeminck A, Geladi P, Van Grieken R, Comparative biochemistry and physiology : B : biochemistry and molecular biology 60, 347 (1978). http://doi.org/10.1016/0305-0491(78)90057-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0305-0491(78)90057-3
|
“Co-crystallization with 1-(2-pyridylazo)-2-naphthol, and X-ray fluorescence, for trace metal analysis of water”. Vanderstappen MG, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 25, 653 (1978). http://doi.org/10.1016/0039-9140(78)80166-0
Abstract: Adding 20mg of 1-(2-pyridylazo)-2-naphthol (PAN) to a water sample at 70°, and filtering off the precipitate after cooling, gives efficient preconcentration prior to X-ray fluorescence analysis of water. Up to the capacity of about 100 μeq of PAN used, the trace metal recoveries are around 90% or higher for Cr3+, Mn2+, Ni2+, Cu2+, Zn2+, Hg2+ and Eu3+, and above 70% for many other ions. The recovery yields usually do not vary critically with pH in the neutral pH-range, and are practically independent of the sample salinity, sample volume and trace-metal concentration. Enrichment factors as high as 2 × 105 can be achieved. Counting statistics would then allow detection limits of 0.03 ppM. The blank levels in commercial PAN, however, lead to typical detection limits of about 1 ppm. The coefficient of variation is typically in the 510% range at the 10-ppM level. The accuracy and applicability of the procedure are illustrated by comparative analyses on samples of synthetic solutions, river and drinking water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(78)80166-0
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
“Trace metal analysis of water containing humic substances by X-ray fluorescence”. Vanderborght BM, Van Grieken RE, International journal of environmental analytical chemistry 5, 221 (1978). http://doi.org/10.1080/03067317808071147
Abstract: Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067317808071147
|
“Chelating 2,2′-diaminodiethylamine cellulose filters and X-ray fluorescence for preconcentration and trace analysis of natural waters”. Smits J, Van Grieken R, International journal of environmental analytical chemistry 9, 81 (1981). http://doi.org/10.1080/03067318108071902
Abstract: The 2,2′-diaminodiethylamine (DEN) functional group can be expected to have ideal properties for the chelation of transition metals and their collection from aqueous solutions, independent of the alkali and alkaline earth ions concentration. Introducing DEN into cellulose filters allows straightforward preconcentration of trace cations by a simple filtration step, and the DEN-filter constitutes a suitable target for X-ray fluorescence (XRF) analysis. The linearity between the XRF-response on the loaded DEN-filter and the trace cation concentration in the solution appears excellent, up to a total filter capacity of ca. 3 μeq.cm−2. The detection limits are around 0.5 μg. l−1 in most practical cases. Accuracy and precision are around 10%. The applicability of the proposed procedure is illustrated on a comparative basis by XRF-analysis of drinking water and surface water, after preconcentration by DEN-filtration and by alternative procedures.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318108071902
|