“Desorption-ionization of organic compounds studied by Fourier transform laser microprobe mass spectrometry”. van Roy W, Struyf H, van Vaeck L, Gijbels R, Caravatti P, Rapid communications in mass spectrometry 8, 40 (1994). http://doi.org/10.1002/rcm.1290080108
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.253
Times cited: 5
DOI: 10.1002/rcm.1290080108
|
“Evaluation of the laser microprobe with time-of-flight mass spectrometer for organic surface and micro-analysis”. van Roy W, van Vaeck L, Gijbels R, , 1959 (1992)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“A Fourier transform laser microprobe mass spectrometer with external ion source for organic and inorganic surface and micro-analysis”. van Roy W, Struyf H, van Vaeck L, Gijbels R, Caravatti P Wiley, Chichester, page 463 (1994).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Ion current rectification, limiting and overlimiting conductances in nanopores”. van Oeffelen L, Van Roy W, Idrissi H, Charlier D, Lagae L, Borghs G, PLoS ONE 10, e0124171 (2015). http://doi.org/10.1371/journal.pone.0124171
Abstract: Previous reports on Poisson-Nernst-Planck (PNP) simulations of solid-state nanopores have focused on steady state behaviour under simplified boundary conditions. These are Neumann boundary conditions for the voltage at the pore walls, and in some cases also Donnan equilibrium boundary conditions for concentrations and voltages at both entrances of the nanopore. In this paper, we report time-dependent and steady state PNP simulations under less restrictive boundary conditions, including Neumann boundary conditions applied throughout the membrane relatively far away from the nanopore. We simulated ion currents through cylindrical and conical nanopores with several surface charge configurations, studying the spatial and temporal dependence of the currents contributed by each ion species. This revealed that, due to slow co-diffusion of oppositely charged ions, steady state is generally not reached in simulations or in practice. Furthermore, it is shown that ion concentration polarization is responsible for the observed limiting conductances and ion current rectification in nanopores with asymmetric surface charges or shapes. Hence, after more than a decade of collective research attempting to understand the nature of ion current rectification in solid-state nanopores, a relatively intuitive model is retrieved. Moreover, we measured and simulated current-voltage characteristics of rectifying silicon nitride nanopores presenting overlimiting conductances. The similarity between measurement and simulation shows that overlimiting conductances can result from the increased conductance of the electric double-layer at the membrane surface at the depletion side due to voltage-induced polarization charges.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.806
Times cited: 11
DOI: 10.1371/journal.pone.0124171
|
“Laser ionization mass spectrometry for the characterization of solid materials”. van Vaeck L, van Roy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 21, 53 (1993)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 10
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, Gijbels R, Caravatti P San Francisco Press, San Francisco, Calif., page 595 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
“Laser microprobe mass spectrometry: local surface analysis of organic and inorganic compounds”. van Vaeck L, van Roy W, Struyf H, Poels K, Gijbels R Vch, Weinheim, page 354 (1997).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Lasers in mass spectrometry: organic and inorganic instrumentation”. van Vaeck L, van Roy W, Gijbels R, Adams F Wiley, New York, page 7 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Structural characterization of organic molecules by laser mass spectrometry”. van Vaeck L, van Roy W, Gijbels R, Adams F Wiley, New York, page 177 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Assessment of local analysis by Fourier transform laser microprobe mass spectrometry with external ion source”. van Roy W, Struyf H, Kennis P, Van Vaeck L, Van Grieken R, Andrle C, Microchimica acta 120, 121 (1995). http://doi.org/10.1007/BF01244426
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01244426
|
“The feasibility of Fourier transform laser microprobe mass spectrometry for applications of local and surface analysis”. Struyf H, van Roy W, Van Vaeck L, Van Grieken R, Caravatti P, Proceedings of the European FTMS Workshop (1994)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|