“Spatial and temporal variation of anthropogenic palladium in the environment”. Bencs L, Ravindra K, Van Grieken R page 433 (2006).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Spatial and temporal variations in particulate Polycyclic Aromatic Hydrocarbon (PAH) levels over Menen (Belgium) and their relation with air mass trajectories”. Ravindra K, Wauters E, Van Grieken R page 838 (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Spatial neutron flux distributions around A 14 MeV neutron generator”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 10, 95 (1972). http://doi.org/10.1007/BF02518771
Abstract: The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02518771
|
|
|
“Speciation and distribution of sulfur and nitrogen in individual aerosol particles measured by LAMMA”. Bruynseels F, Van Grieken R, (1984)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Speciation and diurnal variation of thoracic, fine thoracic and sub-micrometer airborne particulate matter at naturally ventilated office environments”. Horemans B, Van Grieken R, Atmospheric environment : an international journal 44, 1497 (2010). http://doi.org/10.1016/J.ATMOSENV.2010.01.010
Abstract: Thoracic (PM10), fine thoracic (PM2.5) and sub-micrometer (PM1) airborne particulate matter was sampled during day and night. In total, about 100 indoor and outdoor samples were collected for each fraction at ten different office environments. Energy-dispersive X-ray fluorescence spectrometry and ion chromatography were applied for the quantification of some major and minor elements and ions in the collected aerosols. During daytime, mass concentrations were in the ranges: 1129, 8.124, and 6.618 μg m−3, with averages of 20 ± 1, 15.0 ± 0.9, and 11.0 ± 0.8 μg m−3, respectively. At night, mass concentrations were found to be significantly lower for all fractions. Indoor PM1 concentrations exceeded the corresponding outdoor levels during office hours and were thought to be elevated by office printers. Particles with diameters between 1 and 2.5 μm and 2.5 and 10 μm were mainly associated with soil dust elements and were clearly subjected to distinct periods of settling/resuspension. Indoor NO3 − levels were found to follow specific microclimatic conditions at the office environments, while daytime levels of sub-micrometer Cl− were possibly elevated by the use of Cl-containing cleaning products. Indoor carbon black concentrations were sometimes as high as 22 μg m−3 and were strongly correlated with outdoor traffic conditions.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2010.01.010
|
|
|
“Speciation and surface analysis of single particles using electron-excited X-ray emission spectrometry”. Szalóki I, Ro C-U, Osán J, de Hoog J, Van Grieken R page 569 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Speciation of aerosols by combining bulk ion chromatography and thin-window electron probe micro analysis”. Eyckmans K, de Hoog J, van der Auwera L, Van Grieken R, International journal of environmental analytical chemistry 83, 777 (2003). http://doi.org/10.1080/0306731031000118934
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/0306731031000118934
|
|
|
“Speciation of selected metals in aerosol samples by TXRF after sequential leaching”. Samek L, Ostachowicz B, Worobiec A, Spolnik Z, Van Grieken R, X-ray spectrometry 35, 226 (2006). http://doi.org/10.1002/XRS.905
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.905
|
|
|
“Specimen preparation”. Injuk J, Van Grieken R, Blank A, Eksperiandova L, Buhrke V page 411 (2006).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Spectrometric determination of silicon in food and biological samples: an interlaboratory trial”. van Dyck K, Robberecht H, van Cauwenbergh R, Deelstra H, Arnaud J, Willemyns L, Benijts F, Centeno JA, Taylor H, Soares ME, Bastos ML, Ferreira MA, d'Haese PC, Lamberts LV, Hoenig M, Knapp G, Lugowski SJ, Moens L, Riondato J, Van Grieken R, Claes M, Verheyen R, Clement L, Uytterhoeven M, Journal of analytical atomic spectrometry 15, 735 (2000). http://doi.org/10.1039/B000572J
Abstract: Accuracy and precision of silicon determination in biological matrices (serum, urine, water, beer and spinach) by spectrometric techniques (when necessary after acid destruction) were assessed by means of a collaborative interlaboratory trial. The trial was set up in accordance with ISO 5725-2 (1994). The relative overall repeatability standard deviation was acceptable. It varied between 4% for spinach powder (mean content: 176 mg kg(-1)) and 11% for serum (mean content: 5.33 mg L-1). On the other hand, the relative overall between-laboratory standard deviation was found to vary from a satisfactorily 15% for spinach after destruction (mean content: 3.32 mg L-1) to an unacceptable 107% for spinach powder (mean content: 176 mg kg(-1)). The overall conclusion of the trial was that silicon determination in biological matrices can properly be performed by spectrometric techniques. However, when sample pretreatment (i.e., acid destruction) is needed prior to silicon determination problems still remain.
Keywords: A1 Journal article; Behavioural Ecology & Ecophysiology; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B000572J
|
|
|
“Spectroscopy and ion chromatography to study the effects of air pollution on historical buildings”. Van Grieken R, Roekens E, Sweevers H, Vleugels G, Spectroscopy 10, 70 (1989)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“SPME-GC–MS for the off-gassing analysis of a complex museum object”. Alvarez-Martin A, Kavich G, Microchemical Journal 167, 106276 (2021). http://doi.org/10.1016/J.MICROC.2021.106276
Abstract: The identification of volatile organic compounds (VOCs) emitted by a complex museum object, composed of materials of different nature, has been optimized by solid-phase microextraction coupled to gas chromatography-mass spectrometry (SPME-GC–MS). The performance of two fiber coatings and four sampling times were tested and compared in order to define the best sampling conditions. The method allowed a fair extraction of volatile and semivolatile compounds emitted naturally by the object, without any type of accelerating aging. In addition, on-fiber derivatization was applied to improve the extraction efficiency and reduce the sampling time of harmful carboxylic acids emitted by the object. The results obtained are of prime importance to show the off-gassing activity of a valuable museum object in order to take further decisions related with its storage and display conditions.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 3.034
DOI: 10.1016/J.MICROC.2021.106276
|
|
|
“Standardized indoor air quality assessments as a tool to prepare heritage guardians for changing preservation conditions due to climate change”. Anaf W, Leyva Pernia D, Schalm O, Geosciences 8, Unsp 276 (2018). http://doi.org/10.3390/GEOSCIENCES8080276
Abstract: Climate change will affect the preservation conditions of our cultural heritage. Therefore, well-considered mitigation actions should be implemented to safeguard our heritage for future generations. Environmental monitoring is essential to follow up the change in preservation conditions and to evaluate the effectiveness of performed mitigation actions. To support heritage guardians in the processing and evaluation of monitored data, an indoor air quality (IAQ) index for heritage applications is introduced. The index is calculated for each measured point in time and is visualized in a user-friendly and intuitive way. The current paper describes the backbone of the IAQ-calculating algorithm. The algorithm is subsequently applied on a case study in which a mitigation action is implemented in a church.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Systems and software Modelling (AnSyMo); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.3390/GEOSCIENCES8080276
|
|
|
“State-of-the-art and research needs for trace metals”. Playford K, Colin JL, Pacyna JM, Pirrone N, Schulz M, Van Grieken R, Wrembel Z page 7 (1998).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“State-of-the-art X-ray fluorescence instrumentation for chemical analysis”. Margui E, Van Grieken R, Petro Industry News , 16 (2013)
Abstract: Nowadays, X-ray fluorescence spectrometry (XRF) is a well-established analytical technique for qualitative and quantitative elemental analysis (sometimes from Be to U) of a wide variety of samples. In particular, the truly multi-element character, acceptable speed and economy, ease of automation and the possibility to directly analyse solid samples are the most important features among the many that have made it a very mature analytical tool for routine quality controls in many industries, as well as for analytical support for the research laboratory.e recent technological advances, including the design of low-power micro-focus tubes and the novel X-ray optics and detectors have made it possible to extend XRF to the determination of low-Z elements and to obtain 2D or 3D information on a micrometre-scale. Furthermore, the recent development and commercialisation of benchtop and portable instrumentation, that offer extreme simplicity of operation in a low-cost design, have promoted even more the approach of XRF for many analytical problems.is article highlights this state-of-the art technique with regards to currently available XRF instrumentation on the market as well as recent applications in environmental and industrial fields.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Stof : begrippen, bronnen en analysmethoden”. Van Grieken R, (1985)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Stripping voltammetry of tinidazole in solubilized system and biological fluids”. Jain R, Rather JA, Colloids and surfaces: A: physicochemical and engineering aspects 378, 27 (2011). http://doi.org/10.1016/J.COLSURFA.2011.01.045
Abstract: The adsorptive voltammetric behaviour of tinidazole onto the HMDE was investigated and validated in solubilized system and biological fluids by CV, SWCAdSV and DPCAdSV. Addition of CTAB to the solution containing drug enhanced the peak current while anionic and non-ionic surfactants showed an opposite effect. The electrode process is irreversible and adsorption controlled. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for tinidazole determination. Under optimized conditions; the adsorptive stripping peak current is linear over the concentration range 7.0 × 10−9 to 6.2 × 10−7 mol/L with detection limit of 4.5 × 10−10 mol/L. The precision of the proposed method in terms of RSD is 1.2% and mean recovery of 100.01%. The applicability of proposed method is further extended to in vitro determination of the drug in biological fluids.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFA.2011.01.045
|
|
|
“Structural features of human tooth tissues affected by high dose of external ionizing radiation after nuclear catastrophe of Chernobyl plant”. Darchuk LA, Zaverbna LV, Worobiec A, Van Grieken R, Microchemical journal 97, 282 (2011). http://doi.org/10.1016/J.MICROC.2010.09.016
Abstract: The application of micro-Raman spectroscopy is discussed for the analysis of structural features of human tooth tissues affected by high doses of external ionizing radiation (0.51.7 Gy) after the nuclear plant catastrophe in Chernobyl in 1986. The results have shown significant changes in the mineral matrix of dental enamel that lead to the decrease of tooth enamel hardness. Destruction of the collagen chain of the organic matrix has been observed for dentin and cementum.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2010.09.016
|
|
|
“Structural heterogeneity within airborne particles”. Injuk J, de Bock L, Van Grieken R page 173 (1998).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Studia sezonowych zmian wewnetrznego składu powietrza atmosferycznego w kościołach zabytkowych w kontekście doboru i modyfikacji metod konserwacji obiektów zabytkowych”. Samek L, Worobiec A, Spolnik Z, Van Grieken R page 59 (2005).
Keywords: H3 Book chapter; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Study of a unique 16th century Antwerp majolica floor in the Rameyenhof castle's chapel by means of X-ray fluorescence and portable Raman analytical instrumentation”. Van de Voorde L, Vandevijvere M, Vekemans B, Van Pevenage J, Caen J, Vandenabeele P, van Espen P, Vincze L, Spectrochimica acta: part B : atomic spectroscopy 102, 28 (2014). http://doi.org/10.1016/J.SAB.2014.10.007
Abstract: The most unique and only known 16th century Antwerp majolica tile floor in Belgium is situated in a tower of the Rameyenhof castle (Gestel, Belgium). This exceptional work of art has recently been investigated in situ by using X-ray fluorescence (XRF) and Raman spectroscopy in order to study the material characteristics. This study reports on the result of the analyses based on the novel combination of non-destructive and portable instrumentation, including a handheld XRF spectrometer for obtaining elemental information and a mobile Raman spectrometer for retrieving structural and molecular information on the floor tiles in the Rameyenhof castle and on a second, similar medallion, which is stored in the Rubens House museum in Antwerp (Belgium). The investigated material, majolica, is a type of ceramic, which fascinated many people and potters throughout history by its beauty and colourful appearance. In this study the characteristic major/minor and trace element signature of 16th century Antwerp majolica is determined and the pigments used for the colourful paintings present on the floor are identified. Furthermore, based on the elemental fingerprint of the white glaze, and in particular on the presence of zinc in the tiles – an element that was not used for making 16th century majolica – valuable information about the originality of the chapel floor and the two central medallions is acquired. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1016/J.SAB.2014.10.007
|
|
|
“Study of aluminium-exposed fish by scanning proton microprobe analysis”. Eeckhaoudt S, Van Grieken RE, Cholewa M, Legge GJF, Microchimica acta 122, 17 (1996). http://doi.org/10.1007/BF01252401
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01252401
|
|
|
“A study of aluminium-exposed fish using a scanning proton microprobe”. Cholewa M, Legge GJF, Eeckhaoudt S, Van Grieken R, Proceedings of the Australian Conference on Nuclear Techniques of Analysis (1994)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Study of dpa distributions in electron irradiated YBCO slabs through MCCM algorithm”. Piñera I, Cruz CM, van Espen P, Abreu Y, Leyva A, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 274, 191 (2012). http://doi.org/10.1016/J.NIMB.2011.11.021
Abstract: The Monte Carlo assisted Classical Method (MCCM) consists on a calculation procedure for determining the displacements per atom (dpa) distribution in solid materials. This algorithm allows studying the gamma and electron irradiation damage in different materials. It is based on the electrons elastic scattering classic theories and the use of Monte Carlo simulation for the physical processes involved. The present study deals with the Monte Carlo simulation of electron irradiation effects on YBa2Cu3O7-x (YBCO) slabs using the MCNPX code system. Displacements per atom distributions are obtained through the MCCM for electron irradiation up to 10 MeV. In-depth dpa profiles for electrons and positrons are obtained and analysed. Also, dpa contributions from each atomic specie in the material are calculated. It was found that the dpa distribution is more homogeneous in the material volume when increasing energy of incident electrons. Also, the dpa produced by positrons has no relevance when irradiating with electrons, in contrast with previous similar gamma irradiation studies. All the results are presented and discussed in this contribution. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2011.11.021
|
|
|
“Study of environmental effects on deterioration of monuments: case study the cathedral of Bari, Italy”. Zezza F, Torfs K, Van Grieken R, García Pascua N, Macri F, (1996)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Study of individual estuarine suspension particles by automated electron-probe X-ray microanalysis”. Bernard P, Van Grieken R, Eisma D, (1985)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Study of individual particle types and heavy metal deposition for North Sea aerosols using micro and trace analysis techniques”. Van Grieken R, Injuk J, de Bock L, van Malderen H page 105 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Study of individual particle types and heavy metal deposition for North Sea aerosols using micro- and trace analysis techniques”. Injuk J, de Bock L, van Malderen H, Van Grieken R, (1996)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Study of inorganic ammonium compounds in individual marine aerosol particles by laser microprobe mass spectrometry”. Otten P, Bruynseels F, Van Grieken R, Analytica chimica acta 195, 117 (1987). http://doi.org/10.1016/S0003-2670(00)85654-8
Abstract: Ammonia is important in the atmosphere because it neutralizes acidic species. The relative importance of different inorganic ammonium compounds (chloride, nitrate and sulfate) in marine air chemistry was studied by single-particle characterization with the laser microprobe mass analyser. Standard aerosols were generated as a reference for compound identification, based on the fingerprint spectra obtained, and calculation of the relative sensitivity achieved for different ions in a marine aerosol matrix. The relative sensitivity for ammonium was low. Aerosol samples were collected in the Southern Bight of the North Sea under different meteorological conditions and examined for their ammonium compounds. Samples collected during an inversion period with continental influences showed a much higher content in all particles than samples collected under different meteorological conditions, where ammonium was mostly detected in the submicrometer particle-size range.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85654-8
|
|
|
“Study of microgeometry of porous materials using synchrotron computed microtomography”. Jones KW, Feng H, Lindquist WB, Adler PM, Thover JF, Vekemans B, Vincze L, Szalóki I, Van Grieken R, Adams F, Riekel C page 39 (2003).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|