|
Records |
Links |
|
Author |
van Grieken, R.; Gijbels, R.; Blommaert, W.; Vandelannoote, R.; Van 't dack, L. |
|
|
Title |
Geothermal water analysis by X-ray fluorescence and neutron activation |
Type |
H3 Book chapter |
|
Year |
1978 |
Publication |
|
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
368-378 |
|
|
Keywords |
H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
US Energy Research and Development Administration |
Place of Publication |
S.l. |
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
0000-00-00 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
PHYSICS, APPLIED 47/145 Q2 # |
|
|
Call Number |
UA @ lucian @ c:irua:117464 |
Serial |
1335 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderborght, B.; Van Grieken, R. |
|
|
Title |
Automated evaluation of photographically recorded spark-source mass spectra |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
103 |
Issue |
3 |
Pages |
223-235 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A computer routine was developed for qualitative and quantitative analysis of photographically recorded spark-source mass spectra. Particular attention is given to the case of a graphite matrix. The program starts from the line intensities (expressed as Seidel values) and isotope masses calculated from the densitometer readings by a commercially available routine. From the intensities in the different exposures (typically 15 stages), it computes the parameters for the linear parts of the density curves for each ion. Taking into account mutual interferences of multivalent ions, isotope or C-clusters, oxide, carbide and dicarbide ions, the program automatically identifies and then quantifies the elements present. The precision of the results is around 5%. Reading and complete processing of one photoplate is achieved within 23 h. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1978GD90900003 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:113631 |
Serial |
7538 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderstappen, M.G.; Van Grieken, R.E. |
|
|
Title |
Co-crystallization with 1-(2-pyridylazo)-2-naphthol, and X-ray fluorescence, for trace metal analysis of water |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
Talanta : the international journal of pure and applied analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
25 |
Issue |
11/12 |
Pages |
653-658 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Adding 20mg of 1-(2-pyridylazo)-2-naphthol (PAN) to a water sample at 70°, and filtering off the precipitate after cooling, gives efficient preconcentration prior to X-ray fluorescence analysis of water. Up to the capacity of about 100 μeq of PAN used, the trace metal recoveries are around 90% or higher for Cr3+, Mn2+, Ni2+, Cu2+, Zn2+, Hg2+ and Eu3+, and above 70% for many other ions. The recovery yields usually do not vary critically with pH in the neutral pH-range, and are practically independent of the sample salinity, sample volume and trace-metal concentration. Enrichment factors as high as 2 × 105 can be achieved. Counting statistics would then allow detection limits of 0.03 ppM. The blank levels in commercial PAN, however, lead to typical detection limits of about 1 ppm. The coefficient of variation is typically in the 510% range at the 10-ppM level. The accuracy and applicability of the procedure are illustrated by comparative analyses on samples of synthetic solutions, river and drinking water. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1978GG18200005 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0039-9140; 1873-3573 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116556 |
Serial |
7675 |
|
Permanent link to this record |
|
|
|
|
Author |
Decleir, W.; Vlaeminck, A.; Geladi, P.; Van Grieken, R. |
|
|
Title |
Determination of protein-bound copper and zinc in some organs of the cuttlefish Sepia officinalis L |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
Comparative biochemistry and physiology : B : biochemistry and molecular biology |
Abbreviated Journal |
|
|
|
Volume |
60 |
Issue |
|
Pages |
347-350 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1978FN59800001 |
Publication Date |
2003-02-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1096-4959 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116555 |
Serial |
7785 |
|
Permanent link to this record |
|
|
|
|
Author |
Sholkovitz, E.R.; Van Grieken, R.; Eisma, D. |
|
|
Title |
The major-element composition of suspended matter in the Zaire river and estuary |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
Netherlands journal of sea research |
Abbreviated Journal |
|
|
|
Volume |
12 |
Issue |
3/4 |
Pages |
407-413 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2003-08-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0077-7579; 1873-1406 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116608 |
Serial |
8195 |
|
Permanent link to this record |
|
|
|
|
Author |
Smits, J.; Van Grieken, R. |
|
|
Title |
Synthesis of a chelating cellulose filter with 2,2-diaminodiethylamine functional groups |
Type |
A3 Journal article |
|
Year |
1978 |
Publication |
Zeitschrift für angewandte Makromolekare Chemie |
Abbreviated Journal |
|
|
|
Volume |
72 |
Issue |
|
Pages |
105-113 |
|
|
Keywords |
A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116644 |
Serial |
8637 |
|
Permanent link to this record |
|
|
|
|
Author |
Martin, J.-M.; Thomas, A.J.; Van Grieken, R.E. |
|
|
Title |
Trace element composition of Zaire suspended sediments |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
Netherlands journal of sea research |
Abbreviated Journal |
|
|
|
Volume |
12 |
Issue |
3/4 |
Pages |
414-420 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2003-08-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0077-7579; 1873-1406 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116609 |
Serial |
8688 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderborght, B.M.; Van Grieken, R.E. |
|
|
Title |
Trace metal analysis of water containing humic substances by X-ray fluorescence |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
International journal of environmental analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
5 |
Issue |
3 |
Pages |
221-237 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1978FR88000005 |
Publication Date |
2007-07-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0306-7319 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116570 |
Serial |
8692 |
|
Permanent link to this record |