|   | 
Details
   web
Records
Author Van Grieken, R.E.; Bresseleers, C.M.; Vanderborght, B.M.
Title Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water Type A1 Journal article
Year 1977 Publication Analytical chemistry Abbreviated Journal
Volume 49 Issue 9 Pages 1326-1331
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author (up) Thesis
Publisher Place of Publication Editor
Language Wos A1977DP25600011 Publication Date 2005-03-08
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:113632 Serial 7639
Permanent link to this record
 

 
Author Vanderborght, B.M.; Van Grieken, R.E.
Title Enrichment of trace metals in water by adsorption on activated carbon Type A1 Journal article
Year 1977 Publication Analytical chemistry Abbreviated Journal
Volume 49 Issue 2 Pages 311-316
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author (up) Thesis
Publisher Place of Publication Editor
Language Wos Publication Date
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116513 Serial 7923
Permanent link to this record
 

 
Author Vanderborght, B.M.; Van Grieken, R.E.
Title Trace metal analysis of water containing humic substances by X-ray fluorescence Type A1 Journal article
Year 1978 Publication International journal of environmental analytical chemistry Abbreviated Journal
Volume 5 Issue 3 Pages 221-237
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals.
Address
Corporate Author (up) Thesis
Publisher Place of Publication Editor
Language Wos A1978FR88000005 Publication Date 2007-07-07
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0306-7319 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116570 Serial 8692
Permanent link to this record
 

 
Author Vanderborght, B.M.; Van Grieken, R.E.
Title Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon Type A1 Journal article
Year 1980 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 27 Issue 5 Pages 417-422
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Address
Corporate Author (up) Thesis
Publisher Place of Publication Editor
Language Wos A1980JR07800006 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116557 Serial 8746
Permanent link to this record