|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“Leaching of nutrients and trace metals from aerosol samples: a comparison between a re-circulation and an ultrasound system”. Eyckmans K, Zhang J, de Hoog J, Joos P, Van Grieken R, International journal of environmental analytical chemistry 80, 227 (2001). http://doi.org/10.1080/03067310108044372
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067310108044372
|
|
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
|
|
“Method for the determination of Pd-catalyst residues in active pharmaceutical ingredients by means of high-energy polarized-beam energy dispersive X-ray fluorescence”. Marguí, E, van Meel K, Van Grieken R, Buendía A, Fontás C, Hidalgo M, Queralt I, Analytical chemistry 81, 1404 (2009). http://doi.org/10.1021/AC8021373
Abstract: In medicinal chemistry, Pd is perhaps the most-widely utilized precious metal, as catalyst in reactions which represent key transformations toward the synthesis of new active pharmaceutical ingredients (APIs). The disadvantage of this metal-catalyzed chemistry is that expensive and toxic metal residues are invariably left bound to the desired product. Thus, stringent regulatory guidelines exist for the amount of residual Pd that a drug candidate is allowed to contain. In this work, a rapid and simple method for the determination of Pd in API samples by high-energy polarized-beam energy dispersive X-ray fluorescence spectrometry has been developed and validated according to the specification limits of current legislation (10 mg kg−1 Pd) and the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH guidelines). Sample and calibration standards preparation includes a first step of homogenization and then, in a second step, the pressing of the powdered material into pellets without any chemical treatment. The use of several synthetic calibration standards made of cellulose to simulate the API matrix appears to be an effective means to obtain reliable calibration curves with a good spread of data points over the working range. With the use of the best measuring conditions, the limit of detection (0.11 mg kg−1 Pd) as well as the limit of quantitation (0.37 mg kg−1 Pd) achieved meet rigorous requirements. The repeatability of the XRF measurement appeared to be less than 2%, while the precision of the whole method was around 7%. Trueness was evaluated by analyzing spiked API samples at the level of the specification limit and calculating the recovery factor, which was better than 95%. To study the applicability of the developed methodology for the intended purpose, three batches of the studied API were analyzed for their Pd content, and the attained results were comparable to those obtained by the daily routine method (acid digestion plus atomic spectroscopy) used in most pharmaceutical laboratories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC8021373
|
|
|
“A microanalytical study of the gills of aluminium-exposed rainbow trout (Salmo gairdneri)”. Goossenaerts C, Van Grieken R, Jacob W, Witters H, Vanderborght O, International journal of environmental analytical chemistry 34, 227 (1988). http://doi.org/10.1080/03067319808026840
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319808026840
|
|
|
“A Monte Carlo program for quantitative electron-induced x-ray analysis of individual particles”. Ro C-U, Osán J, Szalóki I, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 75, 851 (2003). http://doi.org/10.1021/AC025973R
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC025973R
|
|
|
“Parameter evaluation for the analysis of oxide-based samples with radio ferquency glow discharge mass spectrometry”. de Gendt S, Van Grieken RE, Ohorodnik SK, Harrison WW, Analytical chemistry 67, 1026 (1995). http://doi.org/10.1021/AC00102A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00102A002
|
|
|
“Particulate matter analysis at elementary schools in Curitiba, Brazil”. Avigo D, Godoi AFL, Janissek PR, Makarovska Y, Krata A, Potgieter-Vermaak S, Alfoldy B, Van Grieken R, Godoi RHM, Analytical and bioanalytical chemistry 391, 1459 (2008). http://doi.org/10.1007/S00216-008-2031-Y
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-008-2031-Y
|
|
|
“Performance of total reflection and grazing emission X-ray fluorescence spectrometry for the determination of trace metals in drinking water in relation to other analytical techniques”. Hołynska B, Olko M, Ostachowicz B, Ostachowicz J, Wegrzynek D, Claes M, Van Grieken R, de Bokx P, Kump P, Necemer M, Fresenius' journal of analytical chemistry 362, 294 (1998). http://doi.org/10.1007/S002160051077
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051077
|
|
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
|
|
“Present and future applications of beam techniques in environmental microanalysis”. Jambers W, Van Grieken R, Trends in analytical chemistry 15, 114 (1996). http://doi.org/10.1016/0165-9936(95)00098-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0165-9936(95)00098-4
|
|
|
“Quantitative characterization of individual particle surfaces by fractal analysis of scanning electron microscope images”. van Put A, Vertes A, Wegrzynek D, Treiger B, Van Grieken R, Fresenius' journal of analytical chemistry 350, 440 (1994). http://doi.org/10.1007/BF00321787
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00321787
|
|
|
“Quantitative determination of low-Z elements in single atmospheric particles on boron substrates by automated scanning electron microscopy: energy-dispersive X-ray spectrometry”. Choël M, Deboudt K, Osán J, Flament P, Van Grieken R, Analytical chemistry 77, 5686 (2005). http://doi.org/10.1021/AC050739X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC050739X
|
|
|
“Selenium in environmental waters : determination, speciation and concentration levels”. Robberecht H, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 29, 823 (1982). http://doi.org/10.1016/0039-9140(82)80252-X
Abstract: This article reviews the different methods used for the determination of selenium species in all types of environmental waters. Basic difficulties are discussed and the efficiency of the methods is explained in view of the sub-μg/1. concentration levels. Special attention is paid to preconcentration steps. Published data on speciation and concentration levels in various water samples are critically reviewed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80252-X
|
|
|
“Simultaneous determination of silicon and phosphorus in cast iron by 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 6, 385 (1970). http://doi.org/10.1007/BF02513966
Abstract: A fast (10 min), non-destructive simultaneous determination of silicon and phosphorus in cast iron and steel by 14 MeV neutron activation was developed. The 1.78 MeV28Al activity (T=2.24 min) induced by the reaction28Si(n, p)28Al is counted on a NaI(Tl) detector. Two measurements are made to correct for the 1.81 MeV56Mn activity (T=2.58 hr) from the iron matrix. However,28Al is also produced via31P(n, α)28Al. By (n, 2n) reaction, phosphorus yields also30P (T=2.6 min), the 0.511 MeV annihilation radiation of which is counted by two opposite NaI(Tl) detectors in coincidence. Again, two successive coincidence measurements are carried out in order to take into account the53Fe activity (β+; T=8.9 min) from54Fe(n, 2n)53Fe. The28Al measurement is appropriately corrected via the computed phosphorus content. An oxygen flux monitor was used to normalize to the same flux. Nuclear interferences have been examined. Special attention has been paid to the presence of copper. The standard deviation for phosphorus being as high as ca. 0.09% P for a single determination, this technique can only be practical as an independent phosphorus analysis for high phosphorus cast irons. The precision on the28Al measurement is 5% relative for 0.2% Si and 2.5% above 1% Si.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02513966
|
|
|
“Single-run ion chromatographic separation of inorganic and low-molecular-mass organic anions under isocratic elution: application to environmental samples”. Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 79, 16 (2009). http://doi.org/10.1016/J.TALANTA.2009.02.044
Abstract: For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 ìm particle size), Allsep A-2 (7 ìm particle size), and IC SI-50 4E (5 ìm particle size). A complete baseline separation for all analyzed anions (i.e., F−, acetate, formate, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F−, Ac−, For−, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2009.02.044
|
|
|
“Spark-source mass-spectrometric sensitivity factors for elements in a graphite matrix”. Vanderborght B, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 26, 461 (1979). http://doi.org/10.1016/0039-9140(79)80111-3
Abstract: Relative sensitivity factors for determination of 41 elements by spark-source mass-spectrometry have been measured. The samples were pressed into graphite electrodes and ionized with a radiofrequency spark. The mass spectra were recorded on a photoplate and the resulting data processed by a computer. Indium was used as standard and the relative sensitivity factors for both singly- and doubly-charged ions were determined with reference to the singly-charged indium ion, with an overall error of 30%. The mean analysis precision was 16%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(79)80111-3
|
|
|
“Spatial neutron flux distributions around A 14 MeV neutron generator”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 10, 95 (1972). http://doi.org/10.1007/BF02518771
Abstract: The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02518771
|
|
|
“Speciation of aerosols by combining bulk ion chromatography and thin-window electron probe micro analysis”. Eyckmans K, de Hoog J, van der Auwera L, Van Grieken R, International journal of environmental analytical chemistry 83, 777 (2003). http://doi.org/10.1080/0306731031000118934
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/0306731031000118934
|
|
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
|
|
“Thin-layer potentiometry for creatinine detection in undiluted human urine using ion-exchange membranes as barriers for charged interferences”. Liu Y, Cánovas R, Crespo GA, Cuartero M, Analytical Chemistry 92, 3315 (2020). http://doi.org/10.1021/ACS.ANALCHEM.9B05231
Abstract: Herein, thin-layer potentiometry combined with ion-exchange membranes as barriers for charged interferences is demonstrated for the analytical detection of creatinine (CRE) in undiluted human urine. Briefly, CRE diffuses through an anion-exchange membrane (AEM) from a sample contained in one fluidic compartment to a second reservoir, containing the enzyme CRE deiminase. There, CRE reacts with the enzyme, and the formation of ammonium is dynamically monitored by potentiometric ammonium-selective electrodes. This analytical concept is integrated into a lab-on-a-chip microfluidic cell that allows for a high sample throughput and the operation under stop-flow mode, which allows CRE to passively diffuse across the AEM. Conveniently, positively charged species (i.e., potassium, sodium, and ammonium, among others) are repelled by the AEM and never reach the ammonium-selective electrodes; thus, possible interference in the response can be avoided. As a result, the dynamic potential response of the electrodes is entirely ascribed to the stoichiometric formation of ammonium. The new CRE biosensor exhibits a Nernstian slope, within a linear range of response from 1 to 50 mM CRE concentration. As expected, the response time (15–60 min) primarily depends on the CRE diffusion across the AEM. CRE analysis in urine samples displayed excellent results, without requiring sample pretreatment (before the introduction of the sample in the microfluidic chip) and with high compatibility with development into a potential point-of-care clinical tool. In an attempt to decrease the analysis time, the presented analytical methodology for CRE detection is translated into an all-solid-state platform, in which the enzyme is immobilized on the surface of the ammonium-selective electrode and with the AEM on top. While more work is necessary in this direction, the CRE sensor appears to be promising for CRE analysis in both urine and blood.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.9B05231
|
|
|
“Three-dimensional trace element analysis by confocal X-ray microfluorescence imaging”. Vincze L, Vekemans B, Brenker FE, Falkenberg G, Rickers K, Somogyi A, Kersten M, Adams F, Analytical chemistry 76, 6786 (2004). http://doi.org/10.1021/AC049274L
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC049274L
|
|
|
“Trace metal analysis of water containing humic substances by X-ray fluorescence”. Vanderborght BM, Van Grieken RE, International journal of environmental analytical chemistry 5, 221 (1978). http://doi.org/10.1080/03067317808071147
Abstract: Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067317808071147
|
|
|
“Ultra-thin window electron probe microanalysis of suspended particles in tributaries of Lake Baikal, Siberia”. Semenov MY, Spolnik Z, Granina L, Van Grieken R, International journal of environmental analytical chemistry 85, 377 (2005). http://doi.org/10.1080/03067310500053944
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067310500053944
|
|
|
“The use of a secondary cathode to analyse solid non-conducting samples with direct current glow discharge mass spectrometry: potential and restrictions”. Schelles W, de Gendt S, Maes K, Van Grieken R, Fresenius' journal of analytical chemistry 355, 858 (1996). http://doi.org/10.1007/S0021663550858
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S0021663550858
|
|
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
|
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 78, 4069 (2006). http://doi.org/10.1021/AC060688J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC060688J
|
|
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 76, 3445 (2004). http://doi.org/10.1021/AC0400820
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC0400820
|
|
|
“X-ray spectrometry”. Szalóki I, Török SB, Injuk J, Van Grieken RE, Analytical chemistry 74, 2895 (2002). http://doi.org/10.1021/AC020241K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC020241K
|
|
|
“X-ray spectrometry”. Szalóki I, Török SB, Ro C-U, Injuk J, Van Grieken RE, Analytical chemistry 72, 211 (2000). http://doi.org/10.1021/A1000018H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/A1000018H
|
|