“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 65, 1 (1973). http://doi.org/10.1016/S0003-2670(01)80158-6
Abstract: A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 12
DOI: 10.1016/S0003-2670(01)80158-6
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 64, 187 (1973). http://doi.org/10.1016/S0003-2670(01)82436-3
Abstract: A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 11
DOI: 10.1016/S0003-2670(01)82436-3
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
“Enamels in stained-glass windows : preparation, chemical composition, microstructure and causes of deterioration”. Caen J, Schalm O, van der Snickt G, van der Linden V, Frederickx P, Schryvers D, Janssens K, Cornelis E, van Dyck D, Schreiner M, , 121 (2005)
Keywords: P3 Proceeding; Art; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
|
“Experimental weathering studies of igneous rocks (alkali-granite, granodiorite, gabbro and granite) and sedimentary gneiss under hydrothermal conditions”. Van 't dack L, Beusen J-M, Claesson T, Vandelannoote R, van Grieken R, Gijbels R, , 363 (1985)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Multi-element trace analysis of geothermal waters : problems, characteristics and applicability”. Vandelannoote R, Blommaert W, Van 't dack L, van Grieken R, Gijbels R, , 523 (1985)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace element geochemistry in thermal waters from Amélie-les-Bains (Eastern Pyrenees, France)”. Gijbels R, van Grieken R, Vandelannoote R, Blommaert W, Van 't dack L, , 123 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace element geochemistry in thermal waters from Plombières and Bains (Vosges)”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 396 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Hydrogeochemistry in the zinclead mining district of Les Malines (Gard, France)”. Bosch B, Leleu M, Oustrière P, Sarcia C, Sureau JF, Blommaert W, Gijbels R, Sadurski A, Vandelannoote R, Van Grieken R, Van 'T Dack L;, Chemical geology 55, 31 (1986). http://doi.org/10.1016/0009-2541(86)90125-7
Abstract: Sensitive multi-element analysis techniques together with major-element and isotopic analyses were applied to spring, mine and surface waters in the vicinity of an important known zinclead deposit in a carbonate environment, in the Les Malines area (Gard, France). Both the dissolved and suspended phases were investigated, and concretions and sediments were also considered in some cases. This methodological test shows that the ore body leaves various clear fingerprints, such as the Zn, As, Sb, Pb and U levels in the dissolved phase, the sulfate increment and the δ 34S. Some of the elements in solution are controlled by slightly soluble compounds, e.g. Zn by smithsonite and hydrozincite, Ba by barite, and Pb by hydrocerussite. Mapping the saturation indices for these elements appears useful for displaying the hydrogeochemical anomaly.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.524
Times cited: 3
DOI: 10.1016/0009-2541(86)90125-7
|
“Trace-elemental anomalies in surface water near a small lead-zinc mineralization at Menez-Albot (Brittany, France)”. Vandelannoote R, Blommaert W, Sadurski A, Van 'T Dack L, Gijbels R, Van Grieken R, Bosch B, Leleu M, Rochon J, Sarcia C, Sureau JF;, Journal of geochemical exploration 20, 33 (1984). http://doi.org/10.1016/0375-6742(84)90088-8
Abstract: Sensitive multi-element analysis techniques were applied to water samples collected in the vicinity of a small Zn-Pb-Cu sulfide mineralization in the region of Menez-Albot (Finistère, France). The variation of the trace-element content along a local stream shows the presence of the mineralization, mainly through a simultaneous positive anomaly in solution for a group of about 10 elements (e.g. Ni, Cu, Zn, As, Sb) which are connected with this type of mineralization. The anomaly decreases steeply due to the influx of swamp water rich in Fe, Mn and organic matter. The precipitation barrier is reflected in the stream sediment composition. Contamination from fertilizers was observed in some samples.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.747
Times cited: 4
DOI: 10.1016/0375-6742(84)90088-8
|
“Equilibrium constants for trace elements in natural waters”. Van 't dack L, Blommaert W, Vandelannoote R, Gijbels R, van Grieken R, Reviews in analytical chemistry 7, 297 (1983)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Statistical grouping and controlling factors of dissolved trace elements in a surface water system”. Vandelannoote R, Blommaert W, Van 't dack L, Gijbels R, van Grieken R, Environmental technology letters 4, 363 (1983). http://doi.org/10.1080/09593338309384219
Abstract: Sensitive multi‐element analytical techniques were applied to determine 24 dissolved trace components in 25 different water samples from a 10 km2 zone in Brittany, France. Correspondence factor and multiple regression analyses showed that the elements considered are influenced mainly by the presence of: Fe‐Mn oxide accumulations, a local poly‐metallic sulfide mineralization, and non‐mineralized host rocks, agricultural activity and abundant organic material in local swamps. Via these numerical techniques the location of the poly‐metallic ore body can be derived from the data set.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 1
DOI: 10.1080/09593338309384219
|
“Relative evaluation of neutron activation, X-ray fluorescence and spark source mass spectrometry for multi-element analysis of geothermal waters”. Blommaert W, Vandelannoote R, Van 't dack L, Gijbels R, van Grieken R, Journal of radioanalytical chemistry 57, 382 (1980)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Casting light on the darkening of colors in historical paintings”. da Pieve F, Hogan C, Lamoen D, Verbeeck J, Vanmeert F, Radepont M, Cotte M, Janssens K, Gonze X, Van Tendeloo G, Physical review letters 111, 208302 (2013). http://doi.org/10.1103/PhysRevLett.111.208302
Abstract: The degradation of colors in historical paintings affects our cultural heritage in both museums and archeological sites. Despite intensive experimental studies, the origin of darkening of one of the most ancient pigments known to humankind, vermilion (α-HgS), remains unexplained. Here, by combining many-body theoretical spectroscopy and high-resolution microscopic x-ray diffraction, we clarify the composition of the damaged paint work and demonstrate possible physicochemical processes, induced by illumination and exposure to humidity and air, that cause photoactivation of the original pigment and the degradation of the secondary minerals. The results suggest a new path for the darkening process which was never considered by previous studies and prompt a critical examination of their findings.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.462
Times cited: 30
DOI: 10.1103/PhysRevLett.111.208302
|
“Nanoscale investigation of the degradation mechanism of a historical chrome yellow paint by quantitative electron energy loss spectroscopy mapping of chromium species”. Tan H, Tian H, Verbeeck J, Janssens K, Van Tendeloo G, Angewandte Chemie: international edition in English 52, 11360 (2013). http://doi.org/10.1002/anie.201305753
Abstract: Getting the picture: The investigation of 100 year old chrome yellow paint by transmission electron microscopy and spectroscopy has led to the identification of four types of coreshell particles. This nanoscale investigation has allowed a mechanism to be proposed for the darkening of some bright yellow colors in Van Gogh's paintings (e.g. in Falling leaves (Les Alyscamps), 1888).
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 11.994
Times cited: 29
DOI: 10.1002/anie.201305753
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of spectromicroscopic methods : 3 : synthesis, characterization, and detection of different crystal forms of the chrome yellow pigment”. Monico L, Janssens K, Miliani C, Brunetti BG, Vagnini M, Vanmeert F, Falkenberg G, Abakumov A, Lu Y, Tian H, Verbeeck J, Radepont M, Cotte M, Hendriks E, Geldof M, van der Loeff L, Salvant J, Menu M;, Analytical chemistry 85, 860 (2013). http://doi.org/10.1021/ac302158b
Abstract: The painter, Vincent van Gogh, and some of his contemporaries frequently made use of the pigment chrome yellow that is known to show a tendency toward darkening. This pigment may correspond to various chemical compounds such as PbCrO4 and PbCr1-xSxO4, that may each be present in various crystallographic forms with different tendencies toward degradation. Investigations by X-ray diffraction (XRD), mid-Fourier Transform infrared (FTIR), and Raman instruments (benchtop and portable) and synchrotron radiation-based micro-XRD and X-ray absorption near edge structure spectroscopy performed on oil-paint models, prepared with in-house synthesized PbCrO4 and PbCr1-xSxO4, permitted us to characterize the spectroscopic features of the various forms. On the basis of these results, an extended study has been carried out on historic paint tubes and on embedded paint microsamples taken from yellow-orange/pale yellow areas of 12 Van Gogh paintings, demonstrating that Van Gogh effectively made use of different chrome yellow types. This conclusion was also confirmed by in situ mid-FTIR investigations on Van Goghs Portrait of Gauguin (Van Gogh Museum, Amsterdam).
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 79
DOI: 10.1021/ac302158b
|
“Particle deposition in airways of chronic respiratory patients exposed to an urban aerosol”. Horemans B, Van Holsbeke C, Vos W, Darchuk L, Novakovic V, Fontan AC, de Backer J, van Grieken R, de Backer W, De Wael K, Environmental science and technology 46, 12162 (2012). http://doi.org/10.1021/es302755s
Abstract: Urban atmospheres in modern cities carry characteristic mixtures of particulate pollution which are potentially aggravating for chronic respiratory patients (CRP). Although air quality surveys can be detailed, the obtained information is not always useful to evaluate human health effects. This paper presents a novel approach to estimate particle deposition rates in airways of CRP, based on real air pollution data. By combining computational fluid dynamics with physical-chemical characteristics of particulate pollution, deposition rates are estimated for particles of different toxicological relevance, that is, minerals, iron oxides, sea salts, ammonium salts, and carbonaceous particles. Also, it enables some qualitative evaluation of the spatial, temporal, and patient specific effects on the particle dose upon exposure to the urban atmosphere. Results show how heavy traffic conditions increases the deposition of anthropogenic particles in the trachea and lungs of respiratory patients (here, +0.28 and +1.5 μg·h1, respectively). In addition, local and synoptic meteorological conditions were found to have a strong effect on the overall dose. However, the pathology and age of the patient was found to be more crucial, with highest deposition rates for toxic particles in adults with a mild anomaly, followed by mild asthmatic children and adults with severe respiratory dysfunctions (7, 5, and 3 μg·h1, respectively).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 6.198
Times cited: 5
DOI: 10.1021/es302755s
|
“Cultural heritage and archaeology materials studied by synchrotron spectroscopy and imaging”. Bertrand L, Robinet L, Thoury M, Janssens K, Cohen SX, Schöder S, Applied physics A : materials science &, processing 106, 377 (2012). http://doi.org/10.1007/S00339-011-6686-4
Abstract: The use of synchrotron radiation techniques to study cultural heritage and archaeological materials has undergone a steep increase over the past 10-15 years. The range of materials studied is very broad and encompasses painting materials, stone, glass, ceramics, metals, cellulosic and wooden materials, and a cluster of organic-based materials, in phase with the diversity observed at archaeological sites, museums, historical buildings, etc. Main areas of investigation are: (1) the study of the alteration and corrosion processes, for which the unique non-destructive speciation capabilities of X-ray absorption have proved very beneficial, (2) the understanding of the technologies and identification of the raw materials used to produce archaeological artefacts and art objects and, to a lesser extent, (3) the investigation of current or novel stabilisation, conservation and restoration practices. In terms of the synchrotron methods used, the main focus so far has been on X-ray techniques, primarily X-ray fluorescence, absorption and diffraction, and Fourier-transform infrared spectroscopy. We review here the use of these techniques from recent works published in the field demonstrating the breadth of applications and future potential offered by third generation synchrotron techniques. New developments in imaging and advanced spectroscopy, included in the UV/visible and IR ranges, could even broaden the variety of materials studied, in particular by fostering more studies on organic and complex organic-inorganic mixtures, while new support activities at synchrotron facilities might facilitate transfer of knowledge between synchrotron specialists and users from archaeology and cultural heritage sciences.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.455
Times cited: 55
DOI: 10.1007/S00339-011-6686-4
|
“Aptasensing of chloramphenicol in the presence of its analogues : reaching the maximum residue limit”. Pilehvar S, Mehta J, Dardenne F, Robbens J, Blust R, De Wael K, Analytical chemistry 84, 6753 (2012). http://doi.org/10.1021/AC3012522
Abstract: A novel label-free folding induced aptamer-based electrochemical biosensor for the detection of chloramphenicol (CAP) in the presence of its analogues has been developed. CAP is a broad-spectrum antibiotic which has lost its favor due to its serious adverse toxic effects on human health. Aptamers are artificial nucleic acid ligands (ssDNA or RNA) able to specifically recognize a target such as CAP. In this article, the aptamers are fixed onto a gold electrode surface by a self-assembly approach. In the presence of CAP, the unfolded ssDNA on the electrode surface changes to a hairpin structure bringing the target molecules close to the surface and trigger electron transfer. Detection limits were determined to be 1.6×10-9 mol L-1. In addition, thiamphenicol (TAP) and florfenicol (FF), antibiotics with a similar structure to CAP, did not influence the performance of the aptasensor, suggesting a good selectivity of the CAP-aptasensor. Simplicity and lower detection limit (because of the home-selected aptamers) make that the electrochemical aptasensor is suitable for practical use in the detection of CAP in milk samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 68
DOI: 10.1021/AC3012522
|
“Highly sensitive and selective voltammetric sensor fullerene modified glassy carbon electrode for determination of cefitizoxime in solubilized system”. Jain R, Rather JA, Dwivedi A, Vikas, Electroanalysis 22, 2600 (2010). http://doi.org/10.1002/ELAN.201000243
Abstract: The usefulness of fullerene modified glassy carbon electrode in mediating the reduction of cefitizoxime in solubilized system has been demonstrated. Due to the unique structure and extraordinary properties, fullerene shows higher catalytic efficiency towards cefitizoxime reduction. The kinetic parameters, electron transfer coefficient (α) and rate constant (K0) across the modified electrode are 0.37 and 0.1081/s respectively. The proposed square-wave voltammetric method is linear over the concentration range 1.210.3 µg/mL. The limit of detection (LOD) is found 0.27 ng/mL. High sensitivity and selectivity together with low detection limit of the electrode response make it suitable for the determination of cefitizoxime.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/ELAN.201000243
|
“Voltammetric assay of anti-vertigo drug betahistine hydrochloride in sodium lauryl sulphate”. Jain R, Yadav RK, Rather JA, Colloids and surfaces: A: physicochemical and engineering aspects 366, 63 (2010). http://doi.org/10.1016/J.COLSURFA.2010.05.027
Abstract: Assay and electrochemical behaviour of betahistine hydrochloride in BrittonRobinsons (BR) buffer of pH range 2.512.0 at a glassy carbon electrode have been investigated. Addition of anionic surfactant (sodium lauryl sulphate) to the betahistine hydrochloride solution containing electrolyte enhanced the reduction current signal while neutral surfactant (Tween-20) and cationic surfactant cetyl trimethylammonium bromide (CTAB) showed an opposite effect. Voltammograms of betahistine hydrochloride exhibited a single wave. Based on reduction behaviour of betahistine hydrochloride, a direct square-wave voltammetric method has been developed for the assay of betahistine hydrochloride in pharmaceutical formulation. The proposed method has been validated as per ICH guideline. System and method precision in terms of RSD were 1.88% and 1.60% respectively, whereas the method accuracy was indicated by the recovery of 97.6101.9%. Reduction peak current was linear over the target concentration with correlation coefficient 0.998. The proposed method was successfully applied to the determination of betahistine hydrochloride in pharmaceutical formulation. The results were compared with those obtained by the reference high performance liquid chromatographic method. No significant differences were found between results of proposed and reference methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFA.2010.05.027
|
“Stripping voltammetry of tinidazole in solubilized system and biological fluids”. Jain R, Rather JA, Colloids and surfaces: A: physicochemical and engineering aspects 378, 27 (2011). http://doi.org/10.1016/J.COLSURFA.2011.01.045
Abstract: The adsorptive voltammetric behaviour of tinidazole onto the HMDE was investigated and validated in solubilized system and biological fluids by CV, SWCAdSV and DPCAdSV. Addition of CTAB to the solution containing drug enhanced the peak current while anionic and non-ionic surfactants showed an opposite effect. The electrode process is irreversible and adsorption controlled. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for tinidazole determination. Under optimized conditions; the adsorptive stripping peak current is linear over the concentration range 7.0 × 10−9 to 6.2 × 10−7 mol/L with detection limit of 4.5 × 10−10 mol/L. The precision of the proposed method in terms of RSD is 1.2% and mean recovery of 100.01%. The applicability of proposed method is further extended to in vitro determination of the drug in biological fluids.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFA.2011.01.045
|
“Voltammetric determination of antibacterial drug gemifloxacin in solubilized systems at multi-walled carbon nanotubes modified glassy carbon electrode”. Jain R, Rather JA, Colloids and surfaces: B : biointerfaces 83, 340 (2011). http://doi.org/10.1016/J.COLSURFB.2010.12.003
Abstract: A sensitive electroanalytical method for determination of gemifloxacin in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at multi-walled carbon nanotubes modified glassy carbon electrode in the presence of CTAB. Solubilized system of different surfactants including SDS, Tween-20 and CTAB were taken for the study of electrochemical behaviour of gemifloxacin at modified electrode. The reduction peak current increases in the presence of CTAB while other surfactants show opposite effect. The modified electrode exhibits catalytic activity, high sensitivity, stability and is applicable over wide range of concentration for the determination of gemifloxacin. The mechanism of electrochemical reduction of gemifloxacin has been proposed on the basis of CV, SWV, DPV and coulometeric techniques. The proposed squarewave voltammetric method shows linearity over the concentration range 2.4715.5 μg/mL. The achieved limits of detection (LOD) and quantification (LOQ) are 0.90 ng/mL and 3.0 ng/mL respectively.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFB.2010.12.003
|
“Voltammetric behaviour of drotaverine hydrochloride in surfactant media and its enhancement determination in Tween-20”. Jain R, Vikas, Rather JA, Colloids and surfaces: B : biointerfaces 82, 333 (2011). http://doi.org/10.1016/J.COLSURFB.2010.09.005
Abstract: Simple, sensitive and rapid adsorptive voltammetric behaviour of drotaverine hydrochloride onto the HMDE has been explored and validated in surfactant media by using cyclic, differential pulse and square-wave voltammetry. Addition of Tween-20 to the drotaverine hydrochloride containing electrolyte enhances the reduction current signal. The voltammograms of the drug with Tween-20 in phosphate buffers of pH 2.511.0 exhibit a single well defined reduction peak which may be due to the reduction of Cdouble bond; length as m-dashC group. The cyclic voltammetric studies indicated the reduction of drotaverine hydrochloride at the electrode surface through two electron irreversible step and diffusion-controlled. The peak current showed a linear dependence with the drug concentration over the range 0.87.2 μg mL−1. The calculated LOD and LOQ are 1.8 and 6.0 ng mL−1 by SWCAdSV and 8.1 and 27.2 ng mL−1 by DPCAdSV, respectively. The procedure was applied to the assay of the drug in tablet form with mean percentage recoveries of 100.2% with SWCAdSV and 99.7% with DPCAdSV. The validity of the proposed methods was further assessed by applying a standard addition technique.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFB.2010.09.005
|
“Voltammetric behaviour of nitroxazepine in solubilized system and biological fluids”. Jain R, Rather JA, Dwivedi A, Materials science and engineering: part C: biomimetic materials 31, 230 (2011). http://doi.org/10.1016/J.MSEC.2010.09.001
Abstract: This study reports the development and validation of sensitive and selective assay method for the determination of the antidepressant drug in solubilized system and biological fluids. Solubilized system of different surfactants including cationic, anionic and non-ionic influences the electrochemical response of drug. Addition of cationic surfactant cetrimide to the solution containing drug enhances the peak current signal while anionic and non-ionic showed an opposite effect. The current signal due to reduction process was function of concentration of nitroxazepine, pH, type of surfactant and preconcentration time at the electrode surface. The reduction process is irreversible and adsorption controlled at HMDE. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for niroxazepine hydrochloride determination. The proposed SWCAdSV and DPCAdSV methods are linear over the concentration range 2.0 × 10-7 5.0 × 10-9 mol/L and 6.1 × 10-7 1.0 × 10-8 mol/L with detection limit of 1.62 × 10-10 mo/L and 1.4 × 10-9 mo/L respectively. The method shows good sensitivity, selectivity, accuracy and precision that makes it very suitable for determination of nitroxazepine in pharmaceutical formulation and biological fluids.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MSEC.2010.09.001
|
“Electrochemical sensing of phenicol antibiotics at gold”. Pilehvar S, Dardenne F, Blust R, De Wael K, International journal of electrochemical science 7, 5000 (2012)
Abstract: Phenicols are an effective and a broad spectrum class of antibiotics which has lost favour due to their side effects on human health. A rapid and sensitive electrochemical detection system is developed for the simultaneous detection of chloramphenicol (CAP), thiamphenicol (TAP) and florfenicol (FF). The electrochemical behaviour of CAP in the presence of its derivatives was investigated by cyclic voltammetry (CV) and square wave voltammetry (SWV). At a gold electrode, CAP gives rise to a sensitive cathodic peak at −0.68V (versus SCE) in a tris buffer solution (pH 7.6). This behavior gives us the opportunity to introduce a method for sensing CAP electrochemically in the presence of its derivatives. Calibration graphs were linear in the 2.5-7.4 μmol L-1 concentration range. Deviations from linearity were observed for higher concentrations and this was interpreted to be due to kinetic limitation caused by the saturation of CAP and its reduction products onto the gold electrode surface. A limit of detection of 1 μmol L-1 was found.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.469
|
“Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks”. Margui E, Hidalgo M, Queralt I, van Meel K, Fontas C, Spectrochimica acta: part B : atomic spectroscopy 67, 17 (2012). http://doi.org/10.1016/J.SAB.2011.12.004
Abstract: We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2011.12.004
|
“Evidence of early medieval soda ash glass in the archaeological site of San Genesio (Tuscany)”. Cagno S, Favaretto L, Mendera M, Izmer A, Vanhaecke F, Janssens K, Journal of archaeological science 39, 1540 (2012). http://doi.org/10.1016/J.JAS.2011.12.031
Abstract: The early medieval period marks an important turning point in the history of glassmaking, since it comprises the transition period between the mineral-based silica-soda-lime glass of the Roman tradition and the plant ash-based glass. With the aim of expanding the knowledge on the glass recipes and technologies of this period, 37 glass samples were analyzed, originating from the archaeological excavations of San Genesio (Tuscany) and dated from the fourth to the eleventh century. The major and minor element concentrations were measured with SEM-EDX, while the trace elements were quantified with LA-ICP-MS. The results were compared with published compositions of glass samples of similar age in order to highlight differences and similarities. The results offer a very interesting view on the glass circulation in the religious/residential/manufacturing center of San Genesio in the early medieval period. Most of the glass has a typical late-Roman composition, but some glass fragments are identified as soda ash glass. These are among the earliest medieval ash-fluxed glasses ever found in the Italian peninsula. (C) 2011 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Philosophy; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.602
Times cited: 24
DOI: 10.1016/J.JAS.2011.12.031
|
Cagno S (2012) Compositional analysis of historical glass. 346 p
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|