|
“Identification of the geochemical forms of CR, Zn, Ni, Pb, V, and Cu in an industrial polluted soil by combined μ-XRF/μ-XRD and μ-XANES”. Terzano R, Spagnuolo M, Ruggiero P, Vekemans B, de Nolf W, Janssens K, Fiore S, Falkenberg G (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Pigment identification by scanning μ-XRF/μ-XRD”. de Nolf W, Vekemans B, Janssens K, van der Snickt G, Falkenberg G (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Depth profiling of multilayered systems by means of confocal μ-XRF in the laboratory an at HASYLAB BL L: a comparison”. Alfeld M, Vekemans B, Janssens K, Falkenberg G, Broekaert JAC, Gao N, Gibson D (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Confocal μ-XRF and μ-XAFS studies on fractured granite following a radiotracer migration experiment”. Denecke MA, Janssens K, Brendebach B, Falkenberg G, Römer J, Simon R, Vekemans B, (2007)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of the cd-bearing phases in municipal solid waste and Biomass single fly ash particles using SR-mu XRF Spectroscopy”. Camerani MC, Somogyi A, Vekemans B, Ansell S, Simionovici AS, Steenari B-M, Panas I, Analytical chemistry 79, 6496 (2007). http://doi.org/10.1021/AC070206J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070206J
|
|
|
“Assessing the origin and fate of CR, Ni, Cu, Zn, Ph, and V in industrial polluted soil by combined microspectroscopic techniques and bulk extraction methods”. Terzano R, Spagnuolo M, Vekemans B, de Nolf W, Janssens K, Falkenberg G, Ruggiero P, Environmental science &, technology 41, 6762 (2007). http://doi.org/10.1021/ES070260H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 61
DOI: 10.1021/ES070260H
|
|
|
“Zinc distribution and speciation within rocket plants (Eruca vesicaria L. Cavalieri) grown on a polluted soil amended with compost as determined by XRF microtomography and Micro-Xanes”. Terzano R, al Chami Z, Vekemans B, Janssens K, Miano T, Ruggiero P, Journal of agricultural and food chemistry 56, 3222 (2008). http://doi.org/10.1021/JF073304E
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.154
Times cited: 68
DOI: 10.1021/JF073304E
|
|
|
“Carbonates from the lower part of transition zone or even the lower mantle”. Brenker FE, Vollmer C, Vincze L, Vekemans B, Szymanski A, Janssens K, Szaloki I, Nasdala L, Joswig W, Kaminsky F, Earth and planetary science letters 260, 1 (2007). http://doi.org/10.1016/J.EPSL.2007.02.038
Abstract: Effective CO2-storage in the shallow solid Earth mainly occurs by the formation of carbonates. Although the possibility of transport and storage of carbonates to great depth is demonstrated experimentally, ultra-deep mantle carbonates have not been found before. Applying several in situ analytical techniques on inclusions in diamonds from Juina (Brazil) originating from the lower part of the transition zone (> 580 km) or even the lower mantle (> 670 km), reveal the existence of deep Earth carbonates. These finding unquestionably show that at least locally carbonates exist within the deep Earth and may indicate that the Earth's global CO2-cycle has an ultra-deep extension.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.409
Times cited: 156
DOI: 10.1016/J.EPSL.2007.02.038
|
|
|
“μ-XRF/μ-RS vs. SR μ-XRD for pigment identification in illuminated manuscripts”. van der Snickt G, de Nolf W, Vekemans B, Janssens K, Applied physics A : materials science &, processing 92, 59 (2008). http://doi.org/10.1007/S00339-008-4447-9
Abstract: For the non-destructive identification of pigments and colorants in works of art, in archaeological and in forensic materials, a wide range of analytical techniques can be used. Bearing in mind that every method holds particular limitations, two complementary spectroscopic techniques, namely confocal ì-Raman spectroscopy (ì-RS) and ì-X-ray fluorescence spectroscopy (ì-XRF), were joined in one instrument. The combined ì-XRF and ì-RS device, called PRAXIS unites both complementary techniques in one mobile setup, which allows ì- and in situ analysis. ì-XRF allows one to collect elemental and spatially-resolved information in a non-destructive way on major and minor constituents of a variety of materials. However, the main disadvantages of ì-XRF are the penetration depth of the X-rays and the fact that only elements and not specific molecular combinations of elements can be detected. As a result ì-XRF is often not specific enough to identify the pigments within complex mixtures. Confocal Raman microscopy (ì-RS) can offer a surplus as molecular information can be obtained from single pigment grains. However, in some cases the presence of a strong fluorescence background limits the applicability. In this paper, the concrete analytical possibilities of the combined PRAXIS device are evaluated by comparing the results on an illuminated sheet of parchment with the analytical information supplied by synchrotron radiation ì-X-ray diffraction (SR ì-XRD), a highly specific technique.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.455
Times cited: 56
DOI: 10.1007/S00339-008-4447-9
|
|
|
“Quantitative Fe determination inside tomato roots by confocal μ-XRF”. Terzano R, Spagnuolo M, Ruggiero P, Vekemans B, Scoonjans T, Vincze L, Janssens K, Tomasi N, Cesco S, Falkenberg G page 1513 (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Assessing the origin and fate of Cr, Ni, Cu, Zn, Pb, and V in an industrial polluted soil by combined micro-spectroscopic techniques and bulk extraction methods”. Terzano R, Spagnuolo M, Vekemans B, de Nolf W, Janssens K, Falkenberg G, Fiore S, Ruggiero P (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies”. de Nolf W, Jaroszewicz J, Terzano R, Lind OC, Salbu B, Vekemans B, Janssens K, Falkenberg G, Spectrochimica acta: part B : atomic spectroscopy 64, 775 (2009). http://doi.org/10.1016/J.SAB.2009.06.003
Abstract: The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.30.5° are obtained at the bending magnet source when a pink beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.10.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2009.06.003
|
|
|
“Recent trends in quantitative aspects of microscopic X-ray fluorescence analysis”. Janssens K, de Nolf W, van der Snickt G, Vincze L, Vekemans B, Terzano R, Brenker FE, Trends in analytical chemistry 29, 464 (2010). http://doi.org/10.1016/J.TRAC.2010.03.003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 48
DOI: 10.1016/J.TRAC.2010.03.003
|
|
|
“Solving mercury (Hg) speciation in soil samples by synchrotron X-ray microspectroscopic techniques”. Terzano R, Santoro A, Spagnuolo M, Vekemans B, Medici L, Janssens K, Göttlicher J, Denecke MA, Mangold S, Ruggiero P, Environmental pollution 158, 2702 (2010). http://doi.org/10.1016/J.ENVPOL.2010.04.016
Abstract: Direct mercury (Hg) speciation was assessed for soil samples with a Hg concentration ranging from 7 up to 240 mg kg1. Hg chemical forms were identified and quantified by sequential extractions and bulkand micro-analytical techniques exploiting synchrotron generated X-rays. In particular, microspectroscopic techniques such as m-XRF, m-XRD and m-XANES were necessary to solve bulk Hg speciation, in both soil fractions <2 mm and <2 mm. The main Hg-species found in the soil samples were metacinnabar (b-HgS), cinnabar (a-HgS), corderoite (Hg3S2Cl2), and an amorphous phase containing Hg bound to chlorine and sulfur. The amount of metacinnabar and amorphous phases increased in the fraction <2 mm. No interaction among Hg-species and soil components was observed. All the observed Hgspecies originated from the slow weathering of an inert Hg-containing waste material (K106, U.S. EPA) dumped in the area several years ago, which is changing into a relatively more dangerous source of pollution.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 5.099
Times cited: 30
DOI: 10.1016/J.ENVPOL.2010.04.016
|
|
|
“Analysis of X-ray spectra by iterative least squares (AXIL): new developments”. Vekemans B, Janssens K, Vincze L, Adams F, van Espen P, X-ray spectrometry 23, 278 (1994). http://doi.org/10.1002/XRS.1300230609
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300230609
|
|
|
“PXRF, \mu-XRF, vacuum \mu-XRF, and EPMA analysis of Email Champlevé, objects present in Belgian museums”. van der Linden V, Meesdom E, Devos A, van Dooren R, Nieuwdorp H, Janssen E, Balace S, Vekemans B, Vincze L, Janssens K, Microscopy and microanalysis 17, 674 (2011). http://doi.org/10.1017/S1431927611011950
Abstract: The enamel of 20 Email Champlevé objects dating between the 12th and 19th centuries was investigated by means of microscopic and portable X-ray fluorescence analysis (μ-XRF and PXRF). Seven of these objects were microsampled and the fragments were analyzed with electron probe microanalysis (EPMA) and vacuum μ-XRF to obtain quantitative data about the composition of the glass used to produce these enameled objects. As a result of the evolution of the raw materials employed to produce the base glass, three different compositional groups could be discriminated. The first group consisted of soda-lime-silica glass with a sodium source of mineral origin (with low K content) that was opacified by addition of calcium antimonate crystals. This type of glass was only used in objects made in the 12th century. Email Champlevé objects from the beginning of the 13th century onward were enameled with soda-lime-silica glass with a sodium source of vegetal origin. This type of glass, which has a higher potassium content, was opacified with SnO2 crystals. The glass used for 19th century Email Champlevé artifacts was produced with synthetic and purified components resulting in a different chemical composition compared to the other groups. Although the four analytical techniques employed in this study have their own specific characteristics, they were all found to be suitable for classifying the objects into the different chronological categories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.891
Times cited: 9
DOI: 10.1017/S1431927611011950
|
|
|
“X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation”. Vincze L, Vekemans B, Szaloki I, Brenker FE, Falkenberg G, Rickers K, Aerts K, Van Grieken R, Adams F, , 220 (2004). http://doi.org/10.1117/12.560416
Abstract: Ibis work illustrates the development of X-ray fluorescence tomography and polycapillary based confocal imaging towards a three-dimensional (313), quantitative analytical method with lateral resolution levels down to the 2-20 mum scale. Detailed analytical characterization is given for polycapillary based confocal XRF imaging, which is a new variant of the 3D micro-XRF technique. Applications for 2D/3D micro-XR-F are illustrated for the analysis of biological (zooplankton) and geological samples (microscopic inclusions in natural diamonds and fluid inclusions in quartz). Based on confocal imaging, fully three-dimensional distributions of trace elements could be obtained, representing a significant generalization of the regular 2D scanning technique for micro-XRF spectroscopy. The experimental work described in this paper has been carried out at the ESRF ID18F microfluorescence end-station and at HASYLAB Beam Line L.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.560416
|
|
|
“Accurate evaluation of \mu-PIXE and \mu-XRF spectral data through iterative least squares fitting”. Janssens K, Vekemans B, Adams F, van Espen P, Mutsaers P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 –, 7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY 26-30, 1995, Abano Terme, Italy 109, 179 (1996). http://doi.org/10.1016/0168-583X(95)01211-7
Abstract: The integration of the nonlinear least squares X-ray spectrum evaluation progam AXIL. into a mu-PIXE and a mu-XRF setup is discussed. The use of the software when procesing data sets derived from biological and geological samples is described.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0168-583X(95)01211-7
|
|