|
“Holstein polaron: The effect of coupling to multiple-phonon modes”. Covaci L, Berciu M, Epl 80, 67001 (2007). http://doi.org/10.1209/0295-5075/80/67001
Abstract: We investigate the effects of coupling to multiple-phonon modes on the properties of a Holstein polaron. To this end, we generalize the Momentum Average approximations MA((0)) and MA((1)) to deal with multiple-phonon modes. As for a single-phonon mode, these approximations are found to be numerically very efficient. They become exact for very weak or very strong couplings, and are highly accurate in the intermediate regimes, e.g. the spectral weights obey exactly the first six, respectively eight, sum rules. Our results show that the effect on ground-state properties is cumulative in nature. As a result, if the effective coupling to one mode is much larger than to all the others, this mode effectively determines the ground-state properties. However, even very weak coupling to a second phonon mode has important non-perturbational effects on the higher-energy spectrum, in particular on the dispersion and the phonon statistics of the polaron band. This has important consequences on the analysis and interpretation of data for real materials.
Keywords: A1 Journal article
Impact Factor: 1.957
Times cited: 9
DOI: 10.1209/0295-5075/80/67001
|
|
|
“Giant proximity effect in a phase-fluctuating superconductor”. Marchand D, Covaci L, Berciu M, Franz M, Physical Review Letters 101, 097004 (2008). http://doi.org/10.1103/PhysRevLett.101.097004
Abstract: When a tunneling barrier between two superconductors is formed by a normal material that would be a superconductor in the absence of phase fluctuations, the resulting Josephson effect can undergo an enormous enhancement. We establish this novel proximity effect by a general argument as well as a numerical simulation and argue that it may underlie recent experimental observations of the giant proximity effect between two cuprate superconductors separated by a barrier made of the same material rendered normal by severe underdoping.
Keywords: A1 Journal article
Impact Factor: 8.462
Times cited: 17
DOI: 10.1103/PhysRevLett.101.097004
|
|
|
“Polaron formation in the presence of Rashba spin-orbit coupling: implications for spintronics”. Covaci L, Berciu M, Physical Review Letters 102, 186403 (2009). http://doi.org/10.1103/PhysRevLett.102.186403
Abstract: We study the effects of the Rashba spin-orbit coupling on polaron formation, using a suitable generalization of the momentum average approximation. While previous work on a parabolic band model found that spin-orbit coupling increases the effective mass, we show that the opposite holds for a tight-binding model, unless both the spin-orbit and the electron-phonon couplings are weak. It is thus possible to lower the effective mass of the polaron by increasing the spin-orbit coupling. We also show that when the spin-orbit coupling is large as compared to the phonon energy, the polaron retains only one of the spin-polarized bands in its coherent spectrum. This has major implications for the propagation of spin-polarized currents in such materials, and thus for spintronic applications.
Keywords: A1 Journal article
Impact Factor: 8.462
Times cited: 25
DOI: 10.1103/PhysRevLett.102.186403
|
|
|
Huyskens C (2012) Fouling in submerged membrane bioreactors. 198 p
Keywords: Doctoral thesis; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Cultural heritage and archaeology materials studied by synchrotron spectroscopy and imaging”. Bertrand L, Robinet L, Thoury M, Janssens K, Cohen SX, Schöder S, Applied physics A : materials science &, processing 106, 377 (2012). http://doi.org/10.1007/S00339-011-6686-4
Abstract: The use of synchrotron radiation techniques to study cultural heritage and archaeological materials has undergone a steep increase over the past 10-15 years. The range of materials studied is very broad and encompasses painting materials, stone, glass, ceramics, metals, cellulosic and wooden materials, and a cluster of organic-based materials, in phase with the diversity observed at archaeological sites, museums, historical buildings, etc. Main areas of investigation are: (1) the study of the alteration and corrosion processes, for which the unique non-destructive speciation capabilities of X-ray absorption have proved very beneficial, (2) the understanding of the technologies and identification of the raw materials used to produce archaeological artefacts and art objects and, to a lesser extent, (3) the investigation of current or novel stabilisation, conservation and restoration practices. In terms of the synchrotron methods used, the main focus so far has been on X-ray techniques, primarily X-ray fluorescence, absorption and diffraction, and Fourier-transform infrared spectroscopy. We review here the use of these techniques from recent works published in the field demonstrating the breadth of applications and future potential offered by third generation synchrotron techniques. New developments in imaging and advanced spectroscopy, included in the UV/visible and IR ranges, could even broaden the variety of materials studied, in particular by fostering more studies on organic and complex organic-inorganic mixtures, while new support activities at synchrotron facilities might facilitate transfer of knowledge between synchrotron specialists and users from archaeology and cultural heritage sciences.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.455
Times cited: 55
DOI: 10.1007/S00339-011-6686-4
|
|
|
“Immobilisation of TiO2 into self-supporting photocatalytic foam : influence of acidity on porosity and light penetration”. Tytgat T, Lenaerts S, (2012)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Aptasensing of chloramphenicol in the presence of its analogues : reaching the maximum residue limit”. Pilehvar S, Mehta J, Dardenne F, Robbens J, Blust R, De Wael K, Analytical chemistry 84, 6753 (2012). http://doi.org/10.1021/AC3012522
Abstract: A novel label-free folding induced aptamer-based electrochemical biosensor for the detection of chloramphenicol (CAP) in the presence of its analogues has been developed. CAP is a broad-spectrum antibiotic which has lost its favor due to its serious adverse toxic effects on human health. Aptamers are artificial nucleic acid ligands (ssDNA or RNA) able to specifically recognize a target such as CAP. In this article, the aptamers are fixed onto a gold electrode surface by a self-assembly approach. In the presence of CAP, the unfolded ssDNA on the electrode surface changes to a hairpin structure bringing the target molecules close to the surface and trigger electron transfer. Detection limits were determined to be 1.6×10-9 mol L-1. In addition, thiamphenicol (TAP) and florfenicol (FF), antibiotics with a similar structure to CAP, did not influence the performance of the aptasensor, suggesting a good selectivity of the CAP-aptasensor. Simplicity and lower detection limit (because of the home-selected aptamers) make that the electrochemical aptasensor is suitable for practical use in the detection of CAP in milk samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 68
DOI: 10.1021/AC3012522
|
|
|
“Development and validation of optical detection methods to screen photocatalytic materials for soot oxidation”. Smits M, Tytgat T, Hauchecorne B, Lenaerts S, (2012)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Highly sensitive and selective voltammetric sensor fullerene modified glassy carbon electrode for determination of cefitizoxime in solubilized system”. Jain R, Rather JA, Dwivedi A, Vikas, Electroanalysis 22, 2600 (2010). http://doi.org/10.1002/ELAN.201000243
Abstract: The usefulness of fullerene modified glassy carbon electrode in mediating the reduction of cefitizoxime in solubilized system has been demonstrated. Due to the unique structure and extraordinary properties, fullerene shows higher catalytic efficiency towards cefitizoxime reduction. The kinetic parameters, electron transfer coefficient (α) and rate constant (K0) across the modified electrode are 0.37 and 0.1081/s respectively. The proposed square-wave voltammetric method is linear over the concentration range 1.210.3 µg/mL. The limit of detection (LOD) is found 0.27 ng/mL. High sensitivity and selectivity together with low detection limit of the electrode response make it suitable for the determination of cefitizoxime.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/ELAN.201000243
|
|
|
“Voltammetric assay of anti-vertigo drug betahistine hydrochloride in sodium lauryl sulphate”. Jain R, Yadav RK, Rather JA, Colloids and surfaces: A: physicochemical and engineering aspects 366, 63 (2010). http://doi.org/10.1016/J.COLSURFA.2010.05.027
Abstract: Assay and electrochemical behaviour of betahistine hydrochloride in BrittonRobinsons (BR) buffer of pH range 2.512.0 at a glassy carbon electrode have been investigated. Addition of anionic surfactant (sodium lauryl sulphate) to the betahistine hydrochloride solution containing electrolyte enhanced the reduction current signal while neutral surfactant (Tween-20) and cationic surfactant cetyl trimethylammonium bromide (CTAB) showed an opposite effect. Voltammograms of betahistine hydrochloride exhibited a single wave. Based on reduction behaviour of betahistine hydrochloride, a direct square-wave voltammetric method has been developed for the assay of betahistine hydrochloride in pharmaceutical formulation. The proposed method has been validated as per ICH guideline. System and method precision in terms of RSD were 1.88% and 1.60% respectively, whereas the method accuracy was indicated by the recovery of 97.6101.9%. Reduction peak current was linear over the target concentration with correlation coefficient 0.998. The proposed method was successfully applied to the determination of betahistine hydrochloride in pharmaceutical formulation. The results were compared with those obtained by the reference high performance liquid chromatographic method. No significant differences were found between results of proposed and reference methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFA.2010.05.027
|
|
|
“Stripping voltammetry of tinidazole in solubilized system and biological fluids”. Jain R, Rather JA, Colloids and surfaces: A: physicochemical and engineering aspects 378, 27 (2011). http://doi.org/10.1016/J.COLSURFA.2011.01.045
Abstract: The adsorptive voltammetric behaviour of tinidazole onto the HMDE was investigated and validated in solubilized system and biological fluids by CV, SWCAdSV and DPCAdSV. Addition of CTAB to the solution containing drug enhanced the peak current while anionic and non-ionic surfactants showed an opposite effect. The electrode process is irreversible and adsorption controlled. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for tinidazole determination. Under optimized conditions; the adsorptive stripping peak current is linear over the concentration range 7.0 × 10−9 to 6.2 × 10−7 mol/L with detection limit of 4.5 × 10−10 mol/L. The precision of the proposed method in terms of RSD is 1.2% and mean recovery of 100.01%. The applicability of proposed method is further extended to in vitro determination of the drug in biological fluids.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFA.2011.01.045
|
|
|
“Voltammetric determination of antibacterial drug gemifloxacin in solubilized systems at multi-walled carbon nanotubes modified glassy carbon electrode”. Jain R, Rather JA, Colloids and surfaces: B : biointerfaces 83, 340 (2011). http://doi.org/10.1016/J.COLSURFB.2010.12.003
Abstract: A sensitive electroanalytical method for determination of gemifloxacin in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at multi-walled carbon nanotubes modified glassy carbon electrode in the presence of CTAB. Solubilized system of different surfactants including SDS, Tween-20 and CTAB were taken for the study of electrochemical behaviour of gemifloxacin at modified electrode. The reduction peak current increases in the presence of CTAB while other surfactants show opposite effect. The modified electrode exhibits catalytic activity, high sensitivity, stability and is applicable over wide range of concentration for the determination of gemifloxacin. The mechanism of electrochemical reduction of gemifloxacin has been proposed on the basis of CV, SWV, DPV and coulometeric techniques. The proposed squarewave voltammetric method shows linearity over the concentration range 2.4715.5 μg/mL. The achieved limits of detection (LOD) and quantification (LOQ) are 0.90 ng/mL and 3.0 ng/mL respectively.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFB.2010.12.003
|
|
|
“Voltammetric behaviour of drotaverine hydrochloride in surfactant media and its enhancement determination in Tween-20”. Jain R, Vikas, Rather JA, Colloids and surfaces: B : biointerfaces 82, 333 (2011). http://doi.org/10.1016/J.COLSURFB.2010.09.005
Abstract: Simple, sensitive and rapid adsorptive voltammetric behaviour of drotaverine hydrochloride onto the HMDE has been explored and validated in surfactant media by using cyclic, differential pulse and square-wave voltammetry. Addition of Tween-20 to the drotaverine hydrochloride containing electrolyte enhances the reduction current signal. The voltammograms of the drug with Tween-20 in phosphate buffers of pH 2.511.0 exhibit a single well defined reduction peak which may be due to the reduction of Cdouble bond; length as m-dashC group. The cyclic voltammetric studies indicated the reduction of drotaverine hydrochloride at the electrode surface through two electron irreversible step and diffusion-controlled. The peak current showed a linear dependence with the drug concentration over the range 0.87.2 μg mL−1. The calculated LOD and LOQ are 1.8 and 6.0 ng mL−1 by SWCAdSV and 8.1 and 27.2 ng mL−1 by DPCAdSV, respectively. The procedure was applied to the assay of the drug in tablet form with mean percentage recoveries of 100.2% with SWCAdSV and 99.7% with DPCAdSV. The validity of the proposed methods was further assessed by applying a standard addition technique.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFB.2010.09.005
|
|
|
“Voltammetric behaviour of nitroxazepine in solubilized system and biological fluids”. Jain R, Rather JA, Dwivedi A, Materials science and engineering: part C: biomimetic materials 31, 230 (2011). http://doi.org/10.1016/J.MSEC.2010.09.001
Abstract: This study reports the development and validation of sensitive and selective assay method for the determination of the antidepressant drug in solubilized system and biological fluids. Solubilized system of different surfactants including cationic, anionic and non-ionic influences the electrochemical response of drug. Addition of cationic surfactant cetrimide to the solution containing drug enhances the peak current signal while anionic and non-ionic showed an opposite effect. The current signal due to reduction process was function of concentration of nitroxazepine, pH, type of surfactant and preconcentration time at the electrode surface. The reduction process is irreversible and adsorption controlled at HMDE. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for niroxazepine hydrochloride determination. The proposed SWCAdSV and DPCAdSV methods are linear over the concentration range 2.0 × 10-7 5.0 × 10-9 mol/L and 6.1 × 10-7 1.0 × 10-8 mol/L with detection limit of 1.62 × 10-10 mo/L and 1.4 × 10-9 mo/L respectively. The method shows good sensitivity, selectivity, accuracy and precision that makes it very suitable for determination of nitroxazepine in pharmaceutical formulation and biological fluids.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MSEC.2010.09.001
|
|
|
“Electrochemical sensing of phenicol antibiotics at gold”. Pilehvar S, Dardenne F, Blust R, De Wael K, International journal of electrochemical science 7, 5000 (2012)
Abstract: Phenicols are an effective and a broad spectrum class of antibiotics which has lost favour due to their side effects on human health. A rapid and sensitive electrochemical detection system is developed for the simultaneous detection of chloramphenicol (CAP), thiamphenicol (TAP) and florfenicol (FF). The electrochemical behaviour of CAP in the presence of its derivatives was investigated by cyclic voltammetry (CV) and square wave voltammetry (SWV). At a gold electrode, CAP gives rise to a sensitive cathodic peak at −0.68V (versus SCE) in a tris buffer solution (pH 7.6). This behavior gives us the opportunity to introduce a method for sensing CAP electrochemically in the presence of its derivatives. Calibration graphs were linear in the 2.5-7.4 μmol L-1 concentration range. Deviations from linearity were observed for higher concentrations and this was interpreted to be due to kinetic limitation caused by the saturation of CAP and its reduction products onto the gold electrode surface. A limit of detection of 1 μmol L-1 was found.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.469
|
|
|
“Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks”. Margui E, Hidalgo M, Queralt I, van Meel K, Fontas C, Spectrochimica acta: part B : atomic spectroscopy 67, 17 (2012). http://doi.org/10.1016/J.SAB.2011.12.004
Abstract: We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2011.12.004
|
|
|
“Evidence of early medieval soda ash glass in the archaeological site of San Genesio (Tuscany)”. Cagno S, Favaretto L, Mendera M, Izmer A, Vanhaecke F, Janssens K, Journal of archaeological science 39, 1540 (2012). http://doi.org/10.1016/J.JAS.2011.12.031
Abstract: The early medieval period marks an important turning point in the history of glassmaking, since it comprises the transition period between the mineral-based silica-soda-lime glass of the Roman tradition and the plant ash-based glass. With the aim of expanding the knowledge on the glass recipes and technologies of this period, 37 glass samples were analyzed, originating from the archaeological excavations of San Genesio (Tuscany) and dated from the fourth to the eleventh century. The major and minor element concentrations were measured with SEM-EDX, while the trace elements were quantified with LA-ICP-MS. The results were compared with published compositions of glass samples of similar age in order to highlight differences and similarities. The results offer a very interesting view on the glass circulation in the religious/residential/manufacturing center of San Genesio in the early medieval period. Most of the glass has a typical late-Roman composition, but some glass fragments are identified as soda ash glass. These are among the earliest medieval ash-fluxed glasses ever found in the Italian peninsula. (C) 2011 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Philosophy; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.602
Times cited: 24
DOI: 10.1016/J.JAS.2011.12.031
|
|
|
Cagno S (2012) Compositional analysis of historical glass. 346 p
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electric field gradient calculations in ZnO samples implanted with 111In(111Cd)”. Abreu Y, Cruz CM, van Espen P, Pérez C, Piñera I, Leyva A, Cabal AE, Solid state communications 152, 399 (2012). http://doi.org/10.1016/J.SSC.2011.12.001
Abstract: A first-principles study of the electric field gradient (EFG) calculated for ideal and In-111(Cd-111) implanted ZnO samples is reported in the present work. The study was made for ZnO ideal hexagonal structures and supercells were introduced in order to consider the possible implantation environments. The calculation was done using the “WIEN2k” code within the density functional theory, the exchange and correlation effects were determined by the GGA approximation. Three possible In-111(Cd-111) implantation configurations were studied, one substitutional incorporation at cation site and two interstitials. The obtained EFG values for the ideal structure and the substitutional site are in good agreement with the experimental reports measured by perturbed angular correlation (PAC) and high precision nuclear magnetic resonance (NMR). Thus, the ascription of substitutional incorporation of In-111(Cd-111) probe atom at the ZnO cation site after annealing was confirmed. (C) 2011 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SSC.2011.12.001
|
|
|
“Study of dpa distributions in electron irradiated YBCO slabs through MCCM algorithm”. Piñera I, Cruz CM, van Espen P, Abreu Y, Leyva A, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 274, 191 (2012). http://doi.org/10.1016/J.NIMB.2011.11.021
Abstract: The Monte Carlo assisted Classical Method (MCCM) consists on a calculation procedure for determining the displacements per atom (dpa) distribution in solid materials. This algorithm allows studying the gamma and electron irradiation damage in different materials. It is based on the electrons elastic scattering classic theories and the use of Monte Carlo simulation for the physical processes involved. The present study deals with the Monte Carlo simulation of electron irradiation effects on YBa2Cu3O7-x (YBCO) slabs using the MCNPX code system. Displacements per atom distributions are obtained through the MCCM for electron irradiation up to 10 MeV. In-depth dpa profiles for electrons and positrons are obtained and analysed. Also, dpa contributions from each atomic specie in the material are calculated. It was found that the dpa distribution is more homogeneous in the material volume when increasing energy of incident electrons. Also, the dpa produced by positrons has no relevance when irradiating with electrons, in contrast with previous similar gamma irradiation studies. All the results are presented and discussed in this contribution. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2011.11.021
|
|
|
“Proceedings of the 9th World Bamboo Congress, Antwerp 2012”. Gielis J, Potters G, (2012)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Temperate bamboos in ornamental horticulture: differentiators and spillover effects into the 21st century”. Gielis J page 603 (2012).
Keywords: H3 Book chapter; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Cytokinin dynamics in cell suspension cultures of Bambusa balcooa Roxburgh using UPLC-ESI/MS/MS”. Van den Akker S, Bormans P, Peeters H, Gielis J, Prinsen E page 539 (2012).
Keywords: H3 Book chapter; Engineering sciences. Technology; Integrated Molecular Plant Physiology Research (IMPRES); Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“About “bulky” links, generated by generalized Möbius-Listing bodies”. Gielis J, Tavkelidze I, Ricci PE page 115 (2011).
Keywords: H3 Book chapter; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Management principles of sustainable industrial chemistry”. Reniers G, Sörensen K, Vrancken K, (2012)
Keywords: P3 Proceeding; Economics; Engineering Management (ENM); Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Chemical characterization and source apportionment of fine aerosols”. Ravindra K, Stranger M, Van Grieken R, Sokhi RS (2009).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The use of potentiometric sensors to study (bio)molecular interactions”. De Wael K, Daems D, Van Camp G, Nagels LJ, Analytical chemistry 84, 4921 (2012). http://doi.org/10.1021/AC3005428
Abstract: Potentiometric sensors were used to study molecular interactions in liquid environments, with sensorgram methodology. This is demonstrated with a lipophilic rubber-, and with a collagen based hydrogel sensor coating. The investigated molecules were promazine and tartaric acid respectively. The sensors were placed in a hydrodynamic wall jet system for the recording of sensorgrams. mV sensor responses were first converted to a signal, expressing the concentration of adsorbed organic ions. Using a linearization method, a pseudo first order kinetic model of adsorption was shown to fit the experimental results perfectly. Kass, kon and koff values were calculated.. The technique can be used over 4 decades of concentration, and it is very sensitive to low MW compounds as well as to multiply charged large biomolecules. This study is the first to demonstrate the application of potentiometric sensors as an alternative and complement to SPR methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 10
DOI: 10.1021/AC3005428
|
|
|
“Caracterização dos sistemas iônicos e particulado no reservatório”. Godoi RHM, Bittencourt AVL, Hirata PY, Jafelicci Junior M, dos Reis Neto JM, de Souza Sarkis JE, Zara LF, Van Grieken R page 170 (2011).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Integration of analysis techniques of different scales using X ray induced and electron induced X ray spectrometry for applications in preventive conservation and environmental monitoring”. Van Grieken R, Darchuk L, Kontozova V, Potgieter-Vermaak S, van Meel K, Stefaniak E, Worobiec A page 53 (2011).
Abstract: In the past years, and also within the framework of this CRP, we have used a combination of several nuclear and non-nuclear techniques in fundamental research and especially in various applications. Most work has been done with energy-dispersive X ray fluorescence in combination with electron probe X ray microanalysis, but several other more common analysis techniques have been used as well. The applications have included mostly preventive conservation (e.g. characterisation of damaging atmospheric particles in many museums) and environmental monitoring (e.g. for atmospheric particles in relation to their health effects in outdoor and especially indoor environments). Fundamental aspects have been in the optimising of interfaced electron microprobe and Raman microprobe analysis and the evaluation of the potential of such an instrument for atmospheric aerosols; quite a few unexpected and unpredicted problems have appeared in the latter study.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Elemental composition of bottom-sediments from Pangani river basin, Tanzania : lithogenic and anthropogenic sources”. Hellar-Kihampa H, Potgieter-Vermaak S, van Meel K, Gatto Rotondo G, Kishimba M, Van Grieken R, Toxicological and environmental chemistry 94, 525 (2012). http://doi.org/10.1080/02772248.2011.648940
Abstract: River-bed sediments from the Pangani basin, Tanzania, were characterized for elemental compositions, following contamination risks from rapid expansions of human activities in the area. Samples were collected during two individual seasons and analyzed by high-polarizing beam energy dispersive X-ray fluorescence (EDXRF) for eight major and 14 trace elements. Evaluation of enrichment factors (EFs) was used to investigate the elemental flux and assess the contributions of natural and anthropogenic influences. The abundances of the major elements followed the order Si > Al > Fe > Ca > K > Ti > Mn > P, similar to that of the upper earth's crust, and were generally from the weathering of the bed-rock. The high concentrations of typical anthropogenic trace-elements (Cr < 160 mg kg−1, V < 85 mg kg−1, Ni < 60 mg kg−1, Cu < 87 mg kg−1, La < 90 mg kg−1) coupled with high EFs (>2) in some locations indicated contamination associated with agricultural and industrial activities. Factor analysis extracted five principal components that contributed to 96.0% of the total observed variance. The results indicated that river-bed sediments of the Pangani basin were influenced to a larger extent by lithogenic sources than anthropogenic impacts.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/02772248.2011.648940
|
|