|
Records |
Links |
|
Author |
De Schepper, V.C.J.; Holvoet, K.M.A.; Benedetti, L.; Seuntjens, P.; Vanrolleghem, P.A. |
|
|
Title |
Extension of the river water quality model no. 1 with the fate of pesticides |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Journal of hydroinformatics |
Abbreviated Journal |
|
|
|
Volume |
14 |
Issue |
1 |
Pages |
48-64 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL) |
|
|
Abstract |
The existing River Water Quality Model No. 1 (RWQM1) was extended with processes determining the fate of non-volatile pesticides in the water phase and sediments. The exchange of pesticides between the water column and the sediment is described by three transport processes: diffusion, sedimentation and resuspension. Burial of sediments is also included. The modified model was used to simulate the concentrations of diuron and chloridazon in the river Nil. A good agreement was found between the simulated pesticide concentrations and measured values resulting from a four-month intensive monitoring campaign. The simulation results indicate that pesticide concentrations in the bulk water are not sensitive to the selected biochemical model parameters. it seems that these concentrations are mainly determined by the imposed upstream concentrations, run-off and direct losses. The high concentrations in the bulk water were not observed in the sediment pore water due to a limited exchange between the water column and the sediment. According to a sensitivity analysis, the observed pesticide concentrations are highly sensitive to the diffusion and sorption coefficients. Therefore, model users should determine these parameters with accuracy in order to reduce the degree of uncertainty in their results. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000298618300004 |
Publication Date |
2011-10-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1464-7141 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:96257 |
Serial |
7954 |
|
Permanent link to this record |
|
|
|
|
Author |
De Keersmaecker, M.; De Wael, K.; Adriaens, A. |
|
|
Title |
The use of lead dodecanoate as an environmentally friendly coating to inhibit the corrosion of lead objects : comparison of three different deposition methods |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Progress in organic coatings |
Abbreviated Journal |
Prog Org Coat |
|
|
Volume |
74 |
Issue |
1 |
Pages |
1-7 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
An aqueous sodium dodecanoate solution has been used for the formation of a protective coating for lead. Three deposition methods have been compared: immobilization using cyclic voltammetry, immersion and amperometry. Apart from this, we tested a reduction pretreatment of the lead surface (−1.5 V during 600 s) in order to obtain a more reproducible coating, resulting in a better corrosion protection behavior. The corrosion inhibition properties were examined using potentiodynamic polarization curves and electrochemical impedance measurements in a standard corrosive environment. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000302585300001 |
Publication Date |
2012-02-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0300-9440; 0033-0655 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.858 |
Times cited |
8 |
Open Access |
|
|
|
Notes |
; The Research Foundation – Flanders (FWO) and Ghent University are acknowledged for funding this work. The authors would like to thank Pieter Van Hoe for the production of the embedded lead electrodes. They also acknowledge Pieter Arickx and Jonas Van Damme for their contribution. ; |
Approved |
Most recent IF: 2.858; 2012 IF: 1.848 |
|
|
Call Number |
UA @ admin @ c:irua:96354 |
Serial |
5894 |
|
Permanent link to this record |
|
|
|
|
Author |
Buytaert, V.; Muys, B.; Devriendt, N.; Pelkmans, L.; Kretzschmar, J.G.; Samson, R. |
|
|
Title |
Towards integrated sustainability assessment for energetic use of biomass : a state of the art evaluation of assessment tools |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Renewable and sustainable energy reviews |
Abbreviated Journal |
|
|
|
Volume |
15 |
Issue |
8 |
Pages |
3918-3933 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL) |
|
|
Abstract |
Biomass is expected to play an increasingly significant role in the greening of energy supply. Nevertheless, concerns are rising about the sustainability of large-scale energy crop production. Impacts must be assessed carefully before deciding whether and how this industry should be developed, and what technologies, policies and investment strategies should be pursued. There is need for a comprehensive and reliable sustainability assessment tool to evaluate the environmental, social and economic performance of biomass energy production. This paper paves the way for such a tool by analysing and comparing the performance and applicability of a selection of existing tools that are potentially useful for sustainability assessment of bioenergy systems. The selected tools are: Criteria And Indicators (C&I), Life Cycle Assessment (LCA), Environmental Impact Assessment (EIA), Cost Benefit Analysis (CBA), Exergy Analysis (EA) and System Perturbation Analysis (SPA). To evaluate the tools, a framework was constructed that consists of four evaluation levels: sustainability issues, tool attributes, model structure, area of application. The tools were then evaluated using literature data and with the help of a Delphi panel of experts. Finally, a statistical analysis was performed on the resulting data matrix to detect significant differences between tools. It becomes clear that none of the selected tools is able to perform a comprehensive sustainability assessment of bioenergy systems. Every tool has its particular advantages and disadvantages, which means that trade-offs are inevitable and a balance must be found between scientific accuracy and pragmatic decision making. A good definition of the assessment objective is therefore crucial. It seems an interesting option to create a toolbox that combines procedural parts of C&I and EIA, supplemented with calculation algorithms of LCA and CBA for respectively environmental and economic sustainability indicators. Nevertheless, this would require a more comprehensive interdisciplinary approach to align the different tool characteristics and focuses. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000298764100043 |
Publication Date |
2011-08-06 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1364-0321; 1879-0690 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:96444 |
Serial |
8682 |
|
Permanent link to this record |
|
|
|
|
Author |
De Wael, K.; De Belder, S.; Pilehar, S.; Van Steenberge, G.; Herrebout, W.; Heering, H.A. |
|
|
Title |
Enzyme-gelatin electrochemical biosensors : scaling down |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Biosensors |
Abbreviated Journal |
|
|
|
Volume |
2 |
Issue |
|
Pages |
101-113 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Molecular Spectroscopy (MolSpec) |
|
|
Abstract |
In this article we investigate the possibility of scaling down enzyme-gelatin modified electrodes by spin coating the enzyme-gelatin layer. Special attention is given to the electrochemical behavior of the selected enzymes inside the gelatin matrix. A glassy carbon electrode was used as a substrate to immobilize, in the first instance, horse heart cytochrome c (HHC) in a gelatin matrix. Both a drop dried and a spin coated layer was prepared. On scaling down, a transition from diffusion controlled reactions towards adsorption controlled reactions is observed. Compared to a drop dried electrode, a spin coated electrode showed a more stable electrochemical behavior. Next to HHC, we also incorporated catalase in a spin coated gelatin matrix immobilized on a glassy carbon electrode. By spincoating, highly uniform sub micrometer layers of biocompatible matrices can be constructed. A full electrochemical study and characterization of the modified surfaces has been carried out. It was clear that in the case of catalase, gluteraldehyde addition was needed to prevent leaking of the catalase from the gelatin matrix. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2012-03-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2079-6374 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:96507 |
Serial |
5606 |
|
Permanent link to this record |
|
|
|
|
Author |
Smits, M.; Vanpachtenbeke, F.; Horemans, B.; De Wael, K.; Hauchecorne, B.; Van Langenhove, H.; Demeestere, K.; Lenaerts, S. |
|
|
Title |
Effect of operating and sampling conditions on the exhaust gas composition of small-scale power generators |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
PLoS ONE |
Abbreviated Journal |
Plos One |
|
|
Volume |
7 |
Issue |
3 |
Pages |
e32825-e32825,10 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Sustainable Energy, Air and Water Technology (DuEL) |
|
|
Abstract |
Small stationary diesel engines, like in generator sets, have limited emission control measures and are therefore responsible for 44% of the particulate matter (PM) emissions in the United States. The diesel exhaust composition depends on operating conditions of the combustion engine. Furthermore, the measurements are influenced by the used sampling method. This study examines the effect of engine loading and exhaust gas dilution on the composition of small-scale power generators. These generators are used in different operating conditions than road-transport vehicles, resulting in different emission characteristics. Experimental data were obtained for gaseous volatile organic compounds (VOC) and PM mass concentration, elemental composition and nitrate content. The exhaust composition depends on load condition because of its effect on fuel consumption, engine wear and combustion temperature. Higher load conditions result in lower PM concentration and sharper edged particles with larger aerodynamic diameters. A positive correlation with load condition was found for K, Ca, Sr, Mn, Cu, Zn and Pb adsorbed on PM, elements that originate from lubricating oil or engine corrosion. The nitrate concentration decreases at higher load conditions, due to enhanced nitrate dissociation to gaseous NO at higher engine temperatures. Dilution on the other hand decreases PM and nitrate concentration and increases gaseous VOC and adsorbed metal content. In conclusion, these data show that operating and sampling conditions have a major effect on the exhaust gas composition of small-scale diesel generators. Therefore, care must be taken when designing new experiments or comparing literature results. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000303836500012 |
Publication Date |
2012-03-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1932-6203 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.806 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 2.806; 2012 IF: 3.730 |
|
|
Call Number |
UA @ admin @ c:irua:96545 |
Serial |
5581 |
|
Permanent link to this record |
|
|
|
|
Author |
Tytgat, T.; Hauchecorne, B.; Smits, M.; Verbruggen, S.; Lenaerts, S. |
|
|
Title |
Concept and validation of a fully automated photocatalytic test setup |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Journal of laboratory automation |
Abbreviated Journal |
Jala-J Lab Autom |
|
|
Volume |
17 |
Issue |
2 |
Pages |
134-143 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL) |
|
|
Abstract |
Photocatalytic activity can be studied by several methods, each with its own strengths and weaknesses. To study photocatalytic activity in an easy, user-friendly, and realistic way, a completely new setup has been built. The setup is modularly constructed around Fourier transform infrared spectroscopy (FTIR) spectroscopy at the heart of it, resulting in great versatility. Complementary software has been written for automatic control of the setup and for processing the generated data. Two pollutants, oil and n-octane, are tested to validate the performance of the setup. These validation experiments confirm the usefulness and added value of the setup in general and of the FTIR detection methodology as well. It becomes clear that a system of online measurements with good repeatability, accuracy, and user-friendliness has been created. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000304775300006 |
Publication Date |
2014-07-23 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2211-0682 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.85 |
Times cited |
15 |
Open Access |
|
|
|
Notes |
; The authors disclosed receipt of the following financial support for the research and/or authorship of this article: This work was supported by a Ph.D. grant (T. Tytgat) funded by the Institute of Innovation by Science and Technology in Flanders (IWT) and by a Ph.D. grant (S. Verbruggen) from the Research Foundation of Flanders (FWO). Other funding was made possible by the University of Antwerp. ; |
Approved |
Most recent IF: 2.85; 2012 IF: 1.457 |
|
|
Call Number |
UA @ admin @ c:irua:96649 |
Serial |
5935 |
|
Permanent link to this record |
|
|
|
|
Author |
Godoi, R.H.M.; Hirata, P.Y.; Bitterncourt, A.V.L.; Godoi, A.F.L.; Potgieter-Vermaak, S.; Gatto Rotondo, G.; Van Grieken, R.; et al. |
|
|
Title |
Geochemical assessment of a subtropical reservoir : a case study in Curitiba, Southern Brazil |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Clean : soil, air, water |
Abbreviated Journal |
|
|
|
Volume |
40 |
Issue |
4 |
Pages |
364-372 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Suspended particles and dissolved substances in water provide reactive surfaces, influence metabolic activity and contribute to the net sediment deposition. It therefore plays an important part in the ecology and quality of the water mass. The water quality in reservoirs is crucial and it is naturally maintained by flushing and sedimentation, which continuously remove phosphorus from the water. In some reservoirs, however, these removal processes are countered by recycling of ions which could play a key role to start and/or maintain the eutrophic state. The combination of macro-, trace- and microanalysis techniques can be useful to trace pollution sources through a chemical fingerprint, whether be during an acute environmental disaster or a long-term release of pollutants. The water quality and total metal content of reservoir sediments were assessed in a reservoir, situated in the capital of the Paraná State, in the South-Eastern part of Brazil. The goal of this paper was to determine the metal presence in the sediment and metal and ionic speciation in the Green River reservoir water. Water and bed sediment samples, collected from various sites during 2008 and 2009, were investigated using XRF, ICP-OES, ICP-MS, XRD and zeta potential measurements. Based on the results, the heavy metal concentration and chemical composition of the suspended matter in the water samples, as well as the sediment's chemical composition will be discussed. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000302607800005 |
Publication Date |
2012-01-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1863-0650 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:96973 |
Serial |
7993 |
|
Permanent link to this record |
|
|
|
|
Author |
Hellar-Kihampa, H.; Potgieter-Vermaak, S.; van Meel, K.; Gatto Rotondo, G.; Kishimba, M.; Van Grieken, R. |
|
|
Title |
Elemental composition of bottom-sediments from Pangani river basin, Tanzania : lithogenic and anthropogenic sources |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Toxicological and environmental chemistry |
Abbreviated Journal |
|
|
|
Volume |
94 |
Issue |
3 |
Pages |
525-544 |
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
River-bed sediments from the Pangani basin, Tanzania, were characterized for elemental compositions, following contamination risks from rapid expansions of human activities in the area. Samples were collected during two individual seasons and analyzed by high-polarizing beam energy dispersive X-ray fluorescence (EDXRF) for eight major and 14 trace elements. Evaluation of enrichment factors (EFs) was used to investigate the elemental flux and assess the contributions of natural and anthropogenic influences. The abundances of the major elements followed the order Si > Al > Fe > Ca > K > Ti > Mn > P, similar to that of the upper earth's crust, and were generally from the weathering of the bed-rock. The high concentrations of typical anthropogenic trace-elements (Cr < 160 mg kg−1, V < 85 mg kg−1, Ni < 60 mg kg−1, Cu < 87 mg kg−1, La < 90 mg kg−1) coupled with high EFs (>2) in some locations indicated contamination associated with agricultural and industrial activities. Factor analysis extracted five principal components that contributed to 96.0% of the total observed variance. The results indicated that river-bed sediments of the Pangani basin were influenced to a larger extent by lithogenic sources than anthropogenic impacts. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000304276100007 |
Publication Date |
2012-01-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0277-2248 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:97080 |
Serial |
7889 |
|
Permanent link to this record |
|
|
|
|
Author |
De Wael, K.; Daems, D.; Van Camp, G.; Nagels, L.J. |
|
|
Title |
The use of potentiometric sensors to study (bio)molecular interactions |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
84 |
Issue |
11 |
Pages |
4921-4927 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Potentiometric sensors were used to study molecular interactions in liquid environments, with sensorgram methodology. This is demonstrated with a lipophilic rubber-, and with a collagen based hydrogel sensor coating. The investigated molecules were promazine and tartaric acid respectively. The sensors were placed in a hydrodynamic wall jet system for the recording of sensorgrams. mV sensor responses were first converted to a signal, expressing the concentration of adsorbed organic ions. Using a linearization method, a pseudo first order kinetic model of adsorption was shown to fit the experimental results perfectly. Kass, kon and koff values were calculated.. The technique can be used over 4 decades of concentration, and it is very sensitive to low MW compounds as well as to multiply charged large biomolecules. This study is the first to demonstrate the application of potentiometric sensors as an alternative and complement to SPR methods. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000304783100041 |
Publication Date |
2012-04-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
10 |
Open Access |
|
|
|
Notes |
; Financial support for this work was provided by the University of Antwerp by granting D.D. a BOF interdisciplinary research project. We thank J. Everaert for his help in interpreting the results. K.D.W. and D.D. contributed equally to this work. ; |
Approved |
Most recent IF: 6.32; 2012 IF: 5.695 |
|
|
Call Number |
UA @ admin @ c:irua:97520 |
Serial |
5898 |
|
Permanent link to this record |
|
|
|
|
Author |
Piñera, I.; Cruz, C.M.; van Espen, P.; Abreu, Y.; Leyva, A. |
|
|
Title |
Study of dpa distributions in electron irradiated YBCO slabs through MCCM algorithm |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms |
Abbreviated Journal |
|
|
|
Volume |
274 |
Issue |
|
Pages |
191-194 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The Monte Carlo assisted Classical Method (MCCM) consists on a calculation procedure for determining the displacements per atom (dpa) distribution in solid materials. This algorithm allows studying the gamma and electron irradiation damage in different materials. It is based on the electrons elastic scattering classic theories and the use of Monte Carlo simulation for the physical processes involved. The present study deals with the Monte Carlo simulation of electron irradiation effects on YBa2Cu3O7-x (YBCO) slabs using the MCNPX code system. Displacements per atom distributions are obtained through the MCCM for electron irradiation up to 10 MeV. In-depth dpa profiles for electrons and positrons are obtained and analysed. Also, dpa contributions from each atomic specie in the material are calculated. It was found that the dpa distribution is more homogeneous in the material volume when increasing energy of incident electrons. Also, the dpa produced by positrons has no relevance when irradiating with electrons, in contrast with previous similar gamma irradiation studies. All the results are presented and discussed in this contribution. (C) 2011 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000301611900031 |
Publication Date |
2011-12-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-583x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:97819 |
Serial |
8595 |
|
Permanent link to this record |
|
|
|
|
Author |
Abreu, Y.; Cruz, C.M.; van Espen, P.; Pérez, C.; Piñera, I.; Leyva, A.; Cabal, A.E. |
|
|
Title |
Electric field gradient calculations in ZnO samples implanted with 111In(111Cd) |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Solid state communications |
Abbreviated Journal |
|
|
|
Volume |
152 |
Issue |
5 |
Pages |
399-402 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A first-principles study of the electric field gradient (EFG) calculated for ideal and In-111(Cd-111) implanted ZnO samples is reported in the present work. The study was made for ZnO ideal hexagonal structures and supercells were introduced in order to consider the possible implantation environments. The calculation was done using the “WIEN2k” code within the density functional theory, the exchange and correlation effects were determined by the GGA approximation. Three possible In-111(Cd-111) implantation configurations were studied, one substitutional incorporation at cation site and two interstitials. The obtained EFG values for the ideal structure and the substitutional site are in good agreement with the experimental reports measured by perturbed angular correlation (PAC) and high precision nuclear magnetic resonance (NMR). Thus, the ascription of substitutional incorporation of In-111(Cd-111) probe atom at the ZnO cation site after annealing was confirmed. (C) 2011 Elsevier Ltd. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000301329200016 |
Publication Date |
2011-12-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0038-1098 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:97821 |
Serial |
7857 |
|
Permanent link to this record |
|
|
|
|
Author |
Cagno, S.; Favaretto, L.; Mendera, M.; Izmer, A.; Vanhaecke, F.; Janssens, K. |
|
|
Title |
Evidence of early medieval soda ash glass in the archaeological site of San Genesio (Tuscany) |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Journal of archaeological science |
Abbreviated Journal |
J Archaeol Sci |
|
|
Volume |
39 |
Issue |
5 |
Pages |
1540-1552 |
|
|
Keywords |
A1 Journal article; Philosophy; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The early medieval period marks an important turning point in the history of glassmaking, since it comprises the transition period between the mineral-based silica-soda-lime glass of the Roman tradition and the plant ash-based glass. With the aim of expanding the knowledge on the glass recipes and technologies of this period, 37 glass samples were analyzed, originating from the archaeological excavations of San Genesio (Tuscany) and dated from the fourth to the eleventh century. The major and minor element concentrations were measured with SEM-EDX, while the trace elements were quantified with LA-ICP-MS. The results were compared with published compositions of glass samples of similar age in order to highlight differences and similarities. The results offer a very interesting view on the glass circulation in the religious/residential/manufacturing center of San Genesio in the early medieval period. Most of the glass has a typical late-Roman composition, but some glass fragments are identified as soda ash glass. These are among the earliest medieval ash-fluxed glasses ever found in the Italian peninsula. (C) 2011 Elsevier Ltd. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000301620900034 |
Publication Date |
2012-01-02 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0305-4403 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.602 |
Times cited |
24 |
Open Access |
|
|
|
Notes |
; This research was supported by the Interuniversity Attraction Poles Programme – Belgian Science Policy (IUAP VI/16). The text also presents results of GOA “XANES meets ELNES” (Research Fund University of Antwerp, Belgium) and from FWO (Brussels, Belgium) projects no. G.0704.08 and G.01769.09. ; |
Approved |
Most recent IF: 2.602; 2012 IF: 1.889 |
|
|
Call Number |
UA @ admin @ c:irua:98251 |
Serial |
5618 |
|
Permanent link to this record |
|
|
|
|
Author |
Margui, E.; Hidalgo, M.; Queralt, I.; van Meel, K.; Fontas, C. |
|
|
Title |
Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Spectrochimica acta: part B : atomic spectroscopy |
Abbreviated Journal |
|
|
|
Volume |
67 |
Issue |
|
Pages |
17-23 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000302757200003 |
Publication Date |
2011-12-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0584-8547; 1873-3565 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98338 |
Serial |
7454 |
|
Permanent link to this record |
|
|
|
|
Author |
Pilehvar, S.; Dardenne, F.; Blust, R.; De Wael, K. |
|
|
Title |
Electrochemical sensing of phenicol antibiotics at gold |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
International journal of electrochemical science |
Abbreviated Journal |
Int J Electrochem Sc |
|
|
Volume |
7 |
Issue |
6 |
Pages |
5000-5011 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Phenicols are an effective and a broad spectrum class of antibiotics which has lost favour due to their side effects on human health. A rapid and sensitive electrochemical detection system is developed for the simultaneous detection of chloramphenicol (CAP), thiamphenicol (TAP) and florfenicol (FF). The electrochemical behaviour of CAP in the presence of its derivatives was investigated by cyclic voltammetry (CV) and square wave voltammetry (SWV). At a gold electrode, CAP gives rise to a sensitive cathodic peak at −0.68V (versus SCE) in a tris buffer solution (pH 7.6). This behavior gives us the opportunity to introduce a method for sensing CAP electrochemically in the presence of its derivatives. Calibration graphs were linear in the 2.5-7.4 μmol L-1 concentration range. Deviations from linearity were observed for higher concentrations and this was interpreted to be due to kinetic limitation caused by the saturation of CAP and its reduction products onto the gold electrode surface. A limit of detection of 1 μmol L-1 was found. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1452-3981 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.469 |
Times cited |
|
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 1.469; 2012 IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:98344 |
Serial |
5595 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Rather, J.A.; Dwivedi, A. |
|
|
Title |
Voltammetric behaviour of nitroxazepine in solubilized system and biological fluids |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Materials science and engineering: part C: biomimetic materials |
Abbreviated Journal |
|
|
|
Volume |
31 |
Issue |
2 |
Pages |
230-237 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
This study reports the development and validation of sensitive and selective assay method for the determination of the antidepressant drug in solubilized system and biological fluids. Solubilized system of different surfactants including cationic, anionic and non-ionic influences the electrochemical response of drug. Addition of cationic surfactant cetrimide to the solution containing drug enhances the peak current signal while anionic and non-ionic showed an opposite effect. The current signal due to reduction process was function of concentration of nitroxazepine, pH, type of surfactant and preconcentration time at the electrode surface. The reduction process is irreversible and adsorption controlled at HMDE. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for niroxazepine hydrochloride determination. The proposed SWCAdSV and DPCAdSV methods are linear over the concentration range 2.0 × 10-7 5.0 × 10-9 mol/L and 6.1 × 10-7 1.0 × 10-8 mol/L with detection limit of 1.62 × 10-10 mo/L and 1.4 × 10-9 mo/L respectively. The method shows good sensitivity, selectivity, accuracy and precision that makes it very suitable for determination of nitroxazepine in pharmaceutical formulation and biological fluids. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000286707900024 |
Publication Date |
2010-09-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0928-4931 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98685 |
Serial |
8743 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Vikas; Rather, J.A. |
|
|
Title |
Voltammetric behaviour of drotaverine hydrochloride in surfactant media and its enhancement determination in Tween-20 |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Colloids and surfaces: B : biointerfaces |
Abbreviated Journal |
|
|
|
Volume |
82 |
Issue |
2 |
Pages |
333-339 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Simple, sensitive and rapid adsorptive voltammetric behaviour of drotaverine hydrochloride onto the HMDE has been explored and validated in surfactant media by using cyclic, differential pulse and square-wave voltammetry. Addition of Tween-20 to the drotaverine hydrochloride containing electrolyte enhances the reduction current signal. The voltammograms of the drug with Tween-20 in phosphate buffers of pH 2.511.0 exhibit a single well defined reduction peak which may be due to the reduction of Cdouble bond; length as m-dashC group. The cyclic voltammetric studies indicated the reduction of drotaverine hydrochloride at the electrode surface through two electron irreversible step and diffusion-controlled. The peak current showed a linear dependence with the drug concentration over the range 0.87.2 μg mL−1. The calculated LOD and LOQ are 1.8 and 6.0 ng mL−1 by SWCAdSV and 8.1 and 27.2 ng mL−1 by DPCAdSV, respectively. The procedure was applied to the assay of the drug in tablet form with mean percentage recoveries of 100.2% with SWCAdSV and 99.7% with DPCAdSV. The validity of the proposed methods was further assessed by applying a standard addition technique. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000285858200010 |
Publication Date |
2010-09-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0927-7765 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98686 |
Serial |
8742 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Rather, J.A. |
|
|
Title |
Voltammetric determination of antibacterial drug gemifloxacin in solubilized systems at multi-walled carbon nanotubes modified glassy carbon electrode |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Colloids and surfaces: B : biointerfaces |
Abbreviated Journal |
|
|
|
Volume |
83 |
Issue |
2 |
Pages |
340-346 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A sensitive electroanalytical method for determination of gemifloxacin in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at multi-walled carbon nanotubes modified glassy carbon electrode in the presence of CTAB. Solubilized system of different surfactants including SDS, Tween-20 and CTAB were taken for the study of electrochemical behaviour of gemifloxacin at modified electrode. The reduction peak current increases in the presence of CTAB while other surfactants show opposite effect. The modified electrode exhibits catalytic activity, high sensitivity, stability and is applicable over wide range of concentration for the determination of gemifloxacin. The mechanism of electrochemical reduction of gemifloxacin has been proposed on the basis of CV, SWV, DPV and coulometeric techniques. The proposed squarewave voltammetric method shows linearity over the concentration range 2.4715.5 μg/mL. The achieved limits of detection (LOD) and quantification (LOQ) are 0.90 ng/mL and 3.0 ng/mL respectively. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000287268000020 |
Publication Date |
2010-12-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0927-7765 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98687 |
Serial |
8744 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Rather, J.A. |
|
|
Title |
Stripping voltammetry of tinidazole in solubilized system and biological fluids |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Colloids and surfaces: A: physicochemical and engineering aspects |
Abbreviated Journal |
|
|
|
Volume |
378 |
Issue |
|
Pages |
27-33 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The adsorptive voltammetric behaviour of tinidazole onto the HMDE was investigated and validated in solubilized system and biological fluids by CV, SWCAdSV and DPCAdSV. Addition of CTAB to the solution containing drug enhanced the peak current while anionic and non-ionic surfactants showed an opposite effect. The electrode process is irreversible and adsorption controlled. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for tinidazole determination. Under optimized conditions; the adsorptive stripping peak current is linear over the concentration range 7.0 × 10−9 to 6.2 × 10−7 mol/L with detection limit of 4.5 × 10−10 mol/L. The precision of the proposed method in terms of RSD is 1.2% and mean recovery of 100.01%. The applicability of proposed method is further extended to in vitro determination of the drug in biological fluids. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000289544600004 |
Publication Date |
2011-02-02 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0927-7757 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98688 |
Serial |
8584 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Yadav, R.K.; Rather, J.A. |
|
|
Title |
Voltammetric assay of anti-vertigo drug betahistine hydrochloride in sodium lauryl sulphate |
Type |
A1 Journal article |
|
Year |
2010 |
Publication |
Colloids and surfaces: A: physicochemical and engineering aspects |
Abbreviated Journal |
|
|
|
Volume |
366 |
Issue |
|
Pages |
63-67 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Assay and electrochemical behaviour of betahistine hydrochloride in BrittonRobinsons (BR) buffer of pH range 2.512.0 at a glassy carbon electrode have been investigated. Addition of anionic surfactant (sodium lauryl sulphate) to the betahistine hydrochloride solution containing electrolyte enhanced the reduction current signal while neutral surfactant (Tween-20) and cationic surfactant cetyl trimethylammonium bromide (CTAB) showed an opposite effect. Voltammograms of betahistine hydrochloride exhibited a single wave. Based on reduction behaviour of betahistine hydrochloride, a direct square-wave voltammetric method has been developed for the assay of betahistine hydrochloride in pharmaceutical formulation. The proposed method has been validated as per ICH guideline. System and method precision in terms of RSD were 1.88% and 1.60% respectively, whereas the method accuracy was indicated by the recovery of 97.6101.9%. Reduction peak current was linear over the target concentration with correlation coefficient 0.998. The proposed method was successfully applied to the determination of betahistine hydrochloride in pharmaceutical formulation. The results were compared with those obtained by the reference high performance liquid chromatographic method. No significant differences were found between results of proposed and reference methods. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000280501800010 |
Publication Date |
2010-05-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0927-7757 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98689 |
Serial |
8741 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Rather, J.A.; Dwivedi, A.; Vikas |
|
|
Title |
Highly sensitive and selective voltammetric sensor fullerene modified glassy carbon electrode for determination of cefitizoxime in solubilized system |
Type |
A1 Journal article |
|
Year |
2010 |
Publication |
Electroanalysis |
Abbreviated Journal |
|
|
|
Volume |
22 |
Issue |
21 |
Pages |
2600-2606 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The usefulness of fullerene modified glassy carbon electrode in mediating the reduction of cefitizoxime in solubilized system has been demonstrated. Due to the unique structure and extraordinary properties, fullerene shows higher catalytic efficiency towards cefitizoxime reduction. The kinetic parameters, electron transfer coefficient (α) and rate constant (K0) across the modified electrode are 0.37 and 0.1081/s respectively. The proposed square-wave voltammetric method is linear over the concentration range 1.210.3 µg/mL. The limit of detection (LOD) is found 0.27 ng/mL. High sensitivity and selectivity together with low detection limit of the electrode response make it suitable for the determination of cefitizoxime. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000284052900015 |
Publication Date |
2010-10-04 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1040-0397 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98690 |
Serial |
8042 |
|
Permanent link to this record |
|
|
|
|
Author |
Pilehvar, S.; Mehta, J.; Dardenne, F.; Robbens, J.; Blust, R.; De Wael, K. |
|
|
Title |
Aptasensing of chloramphenicol in the presence of its analogues : reaching the maximum residue limit |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
84 |
Issue |
15 |
Pages |
6753-6758 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A novel label-free folding induced aptamer-based electrochemical biosensor for the detection of chloramphenicol (CAP) in the presence of its analogues has been developed. CAP is a broad-spectrum antibiotic which has lost its favor due to its serious adverse toxic effects on human health. Aptamers are artificial nucleic acid ligands (ssDNA or RNA) able to specifically recognize a target such as CAP. In this article, the aptamers are fixed onto a gold electrode surface by a self-assembly approach. In the presence of CAP, the unfolded ssDNA on the electrode surface changes to a hairpin structure bringing the target molecules close to the surface and trigger electron transfer. Detection limits were determined to be 1.6×10-9 mol L-1. In addition, thiamphenicol (TAP) and florfenicol (FF), antibiotics with a similar structure to CAP, did not influence the performance of the aptasensor, suggesting a good selectivity of the CAP-aptasensor. Simplicity and lower detection limit (because of the home-selected aptamers) make that the electrochemical aptasensor is suitable for practical use in the detection of CAP in milk samples. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000307159200069 |
Publication Date |
2012-06-20 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
68 |
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 6.32; 2012 IF: 5.695 |
|
|
Call Number |
UA @ admin @ c:irua:98816 |
Serial |
5477 |
|
Permanent link to this record |
|
|
|
|
Author |
Bertrand, L.; Robinet, L.; Thoury, M.; Janssens, K.; Cohen, S.X.; Schöder, S. |
|
|
Title |
Cultural heritage and archaeology materials studied by synchrotron spectroscopy and imaging |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Applied physics A : materials science & processing |
Abbreviated Journal |
Appl Phys A-Mater |
|
|
Volume |
106 |
Issue |
2 |
Pages |
377-396 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The use of synchrotron radiation techniques to study cultural heritage and archaeological materials has undergone a steep increase over the past 10-15 years. The range of materials studied is very broad and encompasses painting materials, stone, glass, ceramics, metals, cellulosic and wooden materials, and a cluster of organic-based materials, in phase with the diversity observed at archaeological sites, museums, historical buildings, etc. Main areas of investigation are: (1) the study of the alteration and corrosion processes, for which the unique non-destructive speciation capabilities of X-ray absorption have proved very beneficial, (2) the understanding of the technologies and identification of the raw materials used to produce archaeological artefacts and art objects and, to a lesser extent, (3) the investigation of current or novel stabilisation, conservation and restoration practices. In terms of the synchrotron methods used, the main focus so far has been on X-ray techniques, primarily X-ray fluorescence, absorption and diffraction, and Fourier-transform infrared spectroscopy. We review here the use of these techniques from recent works published in the field demonstrating the breadth of applications and future potential offered by third generation synchrotron techniques. New developments in imaging and advanced spectroscopy, included in the UV/visible and IR ranges, could even broaden the variety of materials studied, in particular by fostering more studies on organic and complex organic-inorganic mixtures, while new support activities at synchrotron facilities might facilitate transfer of knowledge between synchrotron specialists and users from archaeology and cultural heritage sciences. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000299749000009 |
Publication Date |
2011-11-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0947-8396 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.455 |
Times cited |
55 |
Open Access |
|
|
|
Notes |
; The authors acknowledge the critical reading by B. Berrie (National Gallery of Art, Washington DC, USA). We thank J. Mass (Conservation Department, Winterthur Museum and Country Estate, Winterthur, DE, USA), H. Roemich (Institute of Fine Arts, New York University, USA), J. Hiller (Non-Crystalline Diffraction Beamline, Diamond Light Source, Didcot, UK) and J.-P. Echard (Laboratoire de recherche et de restauration, Musee de la musique, Paris, France) for their comments on the presentation of their work in the manuscript. The IPANEMA platform is jointly developed by CNRS, MNHN, the French Ministry of Culture and Communication and SOLEIL, and benefits from a CPER grant (MESR, Region Ile-de-France). Support by the Access to Research Infrastructures activity in the 7th Framework Programme of the EU (CHARISMA Grant Agreement n. 228330) and the NWO Science4Arts programme are acknowledged. ; |
Approved |
Most recent IF: 1.455; 2012 IF: 1.545 |
|
|
Call Number |
UA @ admin @ c:irua:99166 |
Serial |
5561 |
|
Permanent link to this record |
|
|
|
|
Author |
Milošević, M.V.; Perali, A. |
|
|
Title |
Emergent phenomena in multicomponent superconductivity: an introduction to the focus issue |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Superconductor Science & Technology |
Abbreviated Journal |
Supercond Sci Tech |
|
|
Volume |
28 |
Issue |
28 |
Pages |
060201 |
|
|
Keywords |
A1 Journal article; CMT |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000354110200001 |
Publication Date |
2015-04-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0953-2048;1361-6668; |
ISBN |
|
Additional Links |
|
|
|
Impact Factor |
2.878 |
Times cited |
41 |
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 2.878; 2015 IF: 2.325 |
|
|
Call Number |
UA @ lucian @ |
Serial |
3945 |
|
Permanent link to this record |
|
|
|
|
Author |
Roose, D.; Leroux, F.; De Vocht, N.; Guglielmetti, C.; Pintelon, I.; Adriaensen, D.; Ponsaerts, P.; Van der Linden, A.; Bals, S. |
|
|
Title |
Multimodal imaging of micron-sized iron oxide particles following in vitro and in vivo uptake by stem cells: down to the nanometer scale |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Contrast Media & Molecular Imaging |
Abbreviated Journal |
Contrast Media Mol I |
|
|
Volume |
9 |
Issue |
6 |
Pages |
400-408 |
|
|
Keywords |
A1 Journal article; Electron Microscopy for Materials Science (EMAT); |
|
|
Abstract |
In this study, the interaction between cells and micron-sized paramagnetic iron oxide (MPIO) particles was investigated by characterizing MPIO in their original state, and after cellular uptake in vitro as well as in vivo. Moreover, MPIO in the olfactory bulb were studied 9 months after injection. Using various imaging techniques, cell-MPIO interactions were investigated with increasing spatial resolution. Live cell confocal microscopy demonstrated that MPIO co-localize with lysosomes after in vitro cellular uptake. In more detail, a membrane surrounding the MPIO was observed by high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM). Following MPIO uptake in vivo, the same cell-MPIO interaction was observed by HAADF-STEM in the subventricular zone at 1 week and in the olfactory bulb at 9 months after MPIO injection. These findings provide proof for the current hypothesis that MPIO are internalized by the cell through endocytosis. The results also show MPIO are not biodegradable, even after 9 months in the brain. Moreover, they show the possibility of HAADF-STEM generating information on the labeled cell as well as on the MPIO. In summary, the methodology presented here provides a systematic route to investigate the interaction between cells and nanoparticles from the micrometer level down to the nanometer level and beyond. |
|
|
Address |
EMAT, University of Antwerp, Antwerp, Belgium; Bio-Imaging Lab, University of Antwerp, Antwerp, Belgium; Laboratory of Experimental Hematology, University of Antwerp, Antwerp, Belgium |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Wos |
000346172100002 |
Publication Date |
2014-04-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1555-4309; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.307 |
Times cited |
8 |
Open Access |
Not_Open_Access |
|
|
Notes |
IAP-PAI; 262348 ESMI; Hercules Type 1: AUHA 09/001 and AUHA 11/01 |
Approved |
Most recent IF: 3.307; 2014 IF: 2.923 |
|
|
Call Number |
UA @ lucian @ |
Serial |
3938 |
|
Permanent link to this record |
|
|
|
|
Author |
Covaci, L.; Berciu, M. |
|
|
Title |
Survival of the Dirac points in rippled graphene |
Type |
A1 Journal article |
|
Year |
2008 |
Publication |
Physical Review Letters |
Abbreviated Journal |
Phys Rev Lett |
|
|
Volume |
100 |
Issue |
25 |
Pages |
256405 |
|
|
Keywords |
A1 Journal article; Electron Microscopy for Materials Science (EMAT); |
|
|
Abstract |
We study the effects of the rippling of a graphene sheet on quasiparticle dispersion. This is achieved using a generalization to the honeycomb lattice of the momentum average approximation, which is accurate for all coupling strengths and at all energies. We show that even though the position of the Dirac points may move and the Fermi speed can be renormalized significantly, quasiparticles with very long lifetimes survive near the Dirac points even for very strong couplings. |
|
|
Address |
Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada, V6T 1Z1 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Wos |
000257230500047 |
Publication Date |
2008-06-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0031-9007 |
ISBN |
|
Additional Links |
|
|
|
Impact Factor |
8.462 |
Times cited |
15 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 8.462; 2008 IF: 7.180 |
|
|
Call Number |
UA @ lucian @ |
Serial |
4010 |
|
Permanent link to this record |
|
|
|
|
Author |
Covaci, L.; Marsiglio, F. |
|
|
Title |
Proximity effect and Josephson current in clean strong/weak/strong superconducting trilayers |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Physical Review B |
Abbreviated Journal |
Phys Rev B |
|
|
Volume |
73 |
Issue |
1 |
Pages |
014503 |
|
|
Keywords |
A1 Journal article |
|
|
Abstract |
Recent measurements of the Josephson critical current through LSCO/LCO/LSCO thin films showed an unusually large proximity effect. Using the Bogoliubov-de Gennes equations for a tight-binding Hamiltonian we describe the proximity effect in weak links between a superconductor with critical temperature T-c and one with critical temperature T-c('), where T-c > T-c('). The weak link (N-') is therefore a superconductor above its own critical temperature and the superconducting regions are considered to have either s-wave or d-wave symmetry. We note that the proximity effect is enhanced due to the presence of superconducting correlations in the weak link. The dc Josephson current is calculated, and we obtain a nonzero value for temperatures greater than T-c(') for sizes of the weak links that can be almost an order of magnitude greater than the conventional coherence length. Considering pockets of superconductivity in the N-' layer, we show that this can lead to an even larger effect on the Josephson critical current by effectively shortening the weak link. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000235009000103 |
Publication Date |
2006-01-03 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1098-0121 |
ISBN |
|
Additional Links |
|
|
|
Impact Factor |
3.836 |
Times cited |
31 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.836; 2006 IF: 3.107 |
|
|
Call Number |
UA @ lucian @ |
Serial |
4427 |
|
Permanent link to this record |
|
|
|
|
Author |
Doğan, F.; Covaci, L.; Kim, W.; Marsiglio, F. |
|
|
Title |
Emerging nonequilibrium bound state in spin-current–local-spin scattering |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Physical Review B |
Abbreviated Journal |
Phys Rev B |
|
|
Volume |
80 |
Issue |
10 |
Pages |
104434 |
|
|
Keywords |
A1 Journal article |
|
|
Abstract |
Magnetization reversal is a well-studied problem with obvious applicability in computer hard drives. One can accomplish a magnetization reversal in at least one of two ways: application of a magnetic field or through a spin current. The latter is more amenable to a fully quantum-mechanical analysis. We formulate and solve the problem whereby a spin current interacts with a ferromagnetic Heisenberg spin chain, to eventually reverse the magnetization of the chain. Spin flips are accomplished through both elastic and inelastic scattering. A consequence of the inelastic-scattering channel, when it is no longer energetically possible, is the occurrence of a nonequilibrium bound state, which is an emergent property of the coupled local plus itinerant spin system. For certain definite parameter values the itinerant spin lingers near the local spins for some time, before eventually leaking out as an outwardly diffusing state. This phenomenon results in spin-flip dynamics and filtering properties for this type of system. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000270383100077 |
Publication Date |
2009-09-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1098-0121 |
ISBN |
|
Additional Links |
|
|
|
Impact Factor |
3.836 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.836; 2009 IF: 3.475 |
|
|
Call Number |
UA @ lucian @ |
Serial |
4436 |
|
Permanent link to this record |
|
|
|
|
Author |
Goodvin, G.L.; Covaci, L.; Berciu, M. |
|
|
Title |
Holstein polarons near surfaces |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Physical Review Letters |
Abbreviated Journal |
Phys Rev Lett |
|
|
Volume |
103 |
Issue |
17 |
Pages |
176402 |
|
|
Keywords |
A1 Journal article |
|
|
Abstract |
We study the effects of a nearby surface on the spectral weight of a Holstein polaron, using the inhomogeneous momentum average approximation which is accurate over the entire range of electron-phonon (e-ph) coupling strengths. The broken translational symmetry is taken into account exactly. We find that the e-ph coupling gives rise to a large additional surface potential, with strong retardation effects, which may bind surface states even when they are not normally expected. The surface, therefore, has a significant effect and bulk properties are recovered only very far away from it. These results demonstrate that interpretation in terms of bulk quantities of spectroscopic data sensitive only to a few surface layers is not always appropriate. |
|
|
Address |
Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z1 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Wos |
000271164500042 |
Publication Date |
2009-10-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0031-9007 |
ISBN |
|
Additional Links |
|
|
|
Impact Factor |
8.462 |
Times cited |
8 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 8.462; 2009 IF: 7.328 |
|
|
Call Number |
UA @ lucian @ |
Serial |
4435 |
|
Permanent link to this record |
|
|
|
|
Author |
Kim, W.; Covaci, L.; Marsiglio, F. |
|
|
Title |
Impurity scattering of wave packets on a lattice |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Physical Review B |
Abbreviated Journal |
Phys Rev B |
|
|
Volume |
74 |
Issue |
20 |
Pages |
205120 |
|
|
Keywords |
A1 Journal article |
|
|
Abstract |
Quantum transport in a lattice is distinct from its counterpart in continuum media. Even a free wave packet travels differently in a lattice than in the continuum. We describe quantum scattering in a one-dimensional lattice and illustrate characteristics of quantum transport such as resonant transmission. In particular we examine the transport characteristics of a random trimer model. We demonstrate the real-time propagation of a wave packet and its phase shift due to impurity configurations. Spin-flip scattering is also taken into account in a spin-chain system. We show how individual spins in the chain evolve as a result of a spin-flip interaction between an incoming electron and a spin chain. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000242409400030 |
Publication Date |
2006-11-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1098-0121 |
ISBN |
|
Additional Links |
|
|
|
Impact Factor |
3.836 |
Times cited |
14 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.836; 2006 IF: 3.107 |
|
|
Call Number |
UA @ lucian @ |
Serial |
4428 |
|
Permanent link to this record |
|
|
|
|
Author |
Kim, W.; Covaci, L.; Marsiglio, F. |
|
|
Title |
Hidden symmetries of electronic transport in a disordered one-dimensional lattice |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Physical Review B |
Abbreviated Journal |
Phys Rev B |
|
|
Volume |
73 |
Issue |
19 |
Pages |
195109 |
|
|
Keywords |
A1 Journal article |
|
|
Abstract |
Correlated, or extended, impurities play an important role in the transport properties of dirty metals. Here, we examine, in the framework of a tight-binding lattice, the transmission of a single electron through an array of correlated impurities. In particular we show that particles transmit through an impurity array in identical fashion, regardless of the direction of traversal. The demonstration of this fact is straightforward in the continuum limit, but requires a detailed proof for the discrete lattice. We also briefly demonstrate and discuss the time evolution of these scattering states, to delineate regions (in time and space) where the aforementioned symmetry is violated. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000237950400042 |
Publication Date |
2006-05-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1098-0121 |
ISBN |
|
Additional Links |
|
|
|
Impact Factor |
3.836 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.836; 2006 IF: 3.107 |
|
|
Call Number |
UA @ lucian @ |
Serial |
4429 |
|
Permanent link to this record |