“Absorption correction in electron probe x-ray microanalysis of thin samples”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 58, 1282 (1986). http://doi.org/10.1021/AC00298A003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00298A003
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 60, 28r (1988). http://doi.org/10.1021/AC00163A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00163A002
|
|
|
“Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysis”. Wouters LC, Van Grieken RE, Linton RW, Bauer CF, Analytical chemistry 60, 2218 (1988). http://doi.org/10.1021/AC00171A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00171A011
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 62, 101r (1990). http://doi.org/10.1021/AC00211A001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00211A001
|
|
|
“Analysis of X-ray spectra excited by X rays, electrons, and protons in monazite”. Annegarn HJ, Madiba CCP, Sellschop JPF, Genz H, Hoffmann DHH, Low W, Richter A, Van Grieken RE, Physical review : C : nuclear physics 16, 379 (1977). http://doi.org/10.1103/PHYSREVC.16.379
Abstract: Mineral monazite from Malaysia has been investigated by energy dispersive x-ray analysis employing three different methods: x-ray, relativistic electron and proton induced excitation. An upper limit of 15 ppm has been placed on the possible concentration of the superheavy element with Z=126.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1103/PHYSREVC.16.379
|
|
|
“Co-crystallization with 1-(2-pyridylazo)-2-naphthol, and X-ray fluorescence, for trace metal analysis of water”. Vanderstappen MG, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 25, 653 (1978). http://doi.org/10.1016/0039-9140(78)80166-0
Abstract: Adding 20mg of 1-(2-pyridylazo)-2-naphthol (PAN) to a water sample at 70°, and filtering off the precipitate after cooling, gives efficient preconcentration prior to X-ray fluorescence analysis of water. Up to the capacity of about 100 μeq of PAN used, the trace metal recoveries are around 90% or higher for Cr3+, Mn2+, Ni2+, Cu2+, Zn2+, Hg2+ and Eu3+, and above 70% for many other ions. The recovery yields usually do not vary critically with pH in the neutral pH-range, and are practically independent of the sample salinity, sample volume and trace-metal concentration. Enrichment factors as high as 2 × 105 can be achieved. Counting statistics would then allow detection limits of 0.03 ppM. The blank levels in commercial PAN, however, lead to typical detection limits of about 1 ppm. The coefficient of variation is typically in the 510% range at the 10-ppM level. The accuracy and applicability of the procedure are illustrated by comparative analyses on samples of synthetic solutions, river and drinking water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(78)80166-0
|
|
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
|
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
|
|
“Trace metal analysis of water containing humic substances by X-ray fluorescence”. Vanderborght BM, Van Grieken RE, International journal of environmental analytical chemistry 5, 221 (1978). http://doi.org/10.1080/03067317808071147
Abstract: Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067317808071147
|
|
|
“Trace element composition of Zaire suspended sediments”. Martin J-M, Thomas AJ, Van Grieken RE, Netherlands journal of sea research 12, 414 (1978). http://doi.org/10.1016/0077-7579(78)90043-1
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(78)90043-1
|
|
|
“Micro-determination of zirconium-hafnium ratios in zircons by proton induced X-ray emission”. Van Grieken RE, Johansson TB, Winchester JW, Odom L, Fresenius' Zeitschrift für analytische Chemie 275, 343 (1975). http://doi.org/10.1007/BF00437765
Abstract: The zirconium/hafnium ratios of zircons are determined using proton induced X-ray emission. Submilligram samples, imbedded in a starch layer and deposited on a 50 μg/cm2 polystyrene carrier, are irradiated for 1020 min with a 5 nA beam of 3.7 MeV protons, while the Hf-Lβ and Zr-Kα X-rays are counted with a Si(Li) detector. The standard deviation per analysis is in the 36 % range. Only few interferences are possible. To eliminate errors due to absorption effects the zircon layer thickness should be above 40 μm or reproducibly thin samples should be employed. Measuring the Hf-Lβ/Hf-Lα ratio for samples and standards might provide a practical check for the absence of absorption errors. The sensitivity is so favourable that, in practice, the minimal sample size is only limited by the minimal amount that can be handled properly.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00437765
|
|
|
“Characterization of the weathering crust of various historical buildings in Belgium”. Leysen LA, Roekens EJ, Van Grieken RE, De Geyter G, The science of the total environment 90, 117 (1990). http://doi.org/10.1016/0048-9697(90)90190-6
Abstract: A variety of samples, collected from different historical buildings and monuments throughout Belgium, were thoroughly studied, using several trace- and micro-analysis techniques. Thin sections of stones and mortar joints were characterized by means of electron probe X-ray microanalysis (EPXMA). The morphological appearance of the surface weathering crust and the possible presence of non-innate particles in the crust were elucidated using petrographical and electron microscopy. Quantitative characterization of the total chemical composition of the crust surface layer and underlying layer was performed by energy-dispersive X-ray fluorescence, and by ion chromatography and atomic absorption spectrometry for the leachable components. Special attention was also paid to the chemical composition of rain and air at the particular sampling sites. The element distribution in the transition zone between the weathering crust and the original stone material was found to vary greatly amongst the different samples analyzed. Detailed EPXMA measurements on pieces of the weathering crust showed remarkable differences in morphology and composition between the surface and the underlying layer, and provided information about the presence of fly-ash and soil dust particles in the crust. Except for crusts from the city of Brussels, which were all very high in sulphate, the samples appeared to contain very variable sulphate contents; very local micro-climate and environmental conditions at a particular site are more important in determining the weathering condition of the building stones than the local air pollution situation. Bulk analytical characterization further showed, in all the crust samples studied, a very small contribution of nitrogen- and chlorine-containing weathering products, in contrast to sulphur-containing weathering salts.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90190-6
|
|
|
“The elemental composition of airborne particulate matter in the Atacama desert, Chile”. Rojas CM, Figueroa L, Janssens KH, Van Espen PE, Adams FC, Van Grieken RE, The science of the total environment 91, 251 (1990). http://doi.org/10.1016/0048-9697(90)90302-B
Abstract: Air particulate samples were collected at Chapiquiña near Arica (Chile) with a six-stage cascade impactor for about 17-day periods during a 31 month interval. Sixteen elements were determined by energy dispersive X-ray fluorescence analysis, and the elemental concentrations were subjected to principal factor analysis. The variability with time of the coarse particles was described by two factors both related to soil dispersion, whereas the fine particle variations could be explained by a third factor related to marine influence. Enrichment factors were compared with those obtained in other remote continental areas, in particular those of air particulate matter sampled at Chacaltaya, Bolivia. Results point to a negligible anthropogenic influence.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90302-B
|
|
|
“Iron, copper, zinc and lead in hair from Sudanese populations of different age groups”. Eltayeb MAH, Van Grieken RE, The science of the total environment 95, 157 (1990). http://doi.org/10.1016/0048-9697(90)90061-X
Abstract: Energy-dispersive X-ray fluorescence was used for the analysis of hair samples from three different age groups of the Sudanese population. Hair samples were digested in a mixture of nitric and perchloric acids and the metals were then precipitated with ammonium pyrrolidine dithiocarbamate. The variations of the Fe, Cu, Zn and Pb content of hair with age were investigated. The averages of the elemental concentrations in each age group were compared with the other age groups and with literature values. The correlation of each pair of elements in the hair samples was also investigated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90061-X
|
|
|
“Effects of titanium dioxide industry waste dumping on sea water chemistry”. Roekens EJ, Van Grieken RE, Water research 17, 1385 (1983). http://doi.org/10.1016/0043-1354(83)90268-3
Abstract: An investigation was made to determine the influence of the dumping of a 1000 ton day−1, on the average, of acid-iron waste from the titanium dioxide industry into the shallow but turbulent Southern Bight of the North Sea. This waste contains some 20% sulfuric acid and 2% iron. After the passage of the barge that discharges 10 ton of waste min−1 into its wake, the vertical and horizontal distributions of the pH, iron-concentration and turbidity were measured as a function of time. It appeared that a few seconds after the discharge and for a very brief period, the pH was down to approx. 4 and the Fe-concentration was 13 mg l−1. More than 1 min after the discharge a pH below 6 and an iron-level above 3 mg l−1 could not be detected anywhere. The measured factor for waste dilution by sea water, based on the observed acid and iron concentration in the waste and in the discharge track, were around 5000 after 5 min, 9000 after 10 min and 80,000 after 20 min. Before and long after the dumping, the total iron-concentration in this Southern Bight area was around 100 μg l−1, but this high level might be due to natural causes.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0043-1354(83)90268-3
|
|
|
“Kinetics of iron(II) oxidation in seawater of various pH”. Roekens EJ, Van Grieken RE, Marine chemistry 13, 195 (1983). http://doi.org/10.1016/0304-4203(83)90014-2
Abstract: The rate of iron(II) oxidation in North Sea water of pH 5.510 in the range 1025°C has been studied. The oxygenation rate depends linearly on the iron(II) and dissolved oxygen concentrations. The second-order dependence on [OH−], found by several investigators for synthetic solutions, was confirmed in seawater, but only for pOH > 6.9. For pOH < 5.9 the rate appeared to be independent of the pOH. In the intermediate range, pOH 5.96.9, corresponding to the natural pH of seawater, a first-order dependence on the pOH is obeyed. The important discrepancy in the literature between the second-order rate constant for NaCHO3 solutions and for seawater can be attributed predominantly to the incorrect assumption of a second-order pOH dependence in natural seawater. The results can be useful, for example, in predicting the effect of dumping acidic iron waste from the titanium-dioxide industry into the ocean.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(83)90014-2
|
|
|
“Geochemistry of suspended matter from the baltic sea : 1 : results of individual particle characterization by automated electron microprobe”. Bernard PC, Van Grieken RE, Brügmann L, Marine chemistry 26, 155 (1989). http://doi.org/10.1016/0304-4203(89)90058-3
Abstract: Automated electron probe X-ray microanalysis was used to characterize some 15 000 individual suspension particles from 50 samples of suspended matter collected from different depths at 18 stations throughout the Baltic Sea and the transient area to the North Sea. For each particle, 14 minor and major elements were determined and size information data were obtained. To process this huge amount of results, multivariate analysis techniques were invoked: the particles were classified into specific types and the abundance variations of these groups were studied. It appeared that 80% of all investigated particles contained mostly silicon, and seemed to consist of quartz, and K-rich and Fe-rich aluminosilicates. The abundance of BaSO4 particles averaged 5% throughout the Baltic Sea, but amounted to up to 44% at some stations. The abundance of the Fe-rich particles varied significantly with location and depth, and averaged ∼ 4%. They were often found to be associated with significant amounts of P. Both of these particle types and the Mn-rich particles are thought to be mainly authigenic. Calcium carbonate particles are more abundant towards the North Sea (which seems to act as a source). Principal component analysis of the data revealed that most of the compositional variability can be explained by differences between deep and surface waters and by the influences of inflowing North Sea waters. Additional information about the types and sources of the suspended matter in the Baltic Sea was gained from the comparison and correlation of the single particle results with different fractions of the bulk concentrations of elements such as Al, Ca, Mn, Fe, Zn and Ba.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(89)90058-3
|
|
|
“Doped albumin : stndardization possibilities for LAMMA-analysis of thin freeze-dried cryosections of biological tissue”. Verbueken AH, Jacob WA, Frederik PM, Busing WM, Hersten RC, Van Grieken RE, Journal de physique 45, 561 (1984)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Reviews in analytical chemistry 56, 241r (1984)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
van de Vijver FL, Verbueken AH, Visser WJ, Van Grieken RE, de Broe ME (1984) Localisation of aluminium and iron by histochemical and laster microprobe mass analytical techniques in bone marrow cells of chronic hemodialysis patients. 837–838
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1136/JCP.37.7.837-B
|
|
|
“Kinetics of iron(II) oxidation in seawater of various pH : reply”. Roekens EJ, Van Grieken RE, Marine chemistry 15, 281 (1984). http://doi.org/10.1016/0304-4203(84)90025-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(84)90025-2
|
|
|
“Laser microprobe mass spectrometry of platinum in dog kidney after cisplatin adminstration”. Verbueken AH, Van Grieken RE, Paulus GJ, Verpooten GA, de Broe ME, Biomedical mass spectrometry 11, 159 (1984). http://doi.org/10.1002/BMS.1200110404
Abstract: By means of laser microprobe mass analysis (LAMMA) platinum was detected in the renal proximal tubular cells of a dog that had been intravenously adminstered the antitumor drug cisplatin (5 mg per kg body weight). No definite subcellular localization of the heavy metal was obtained. Sample prparation and analytical features are examined to increase spatial resolution of analysis while maintaining sufficient detection efficiency. The LAMMA method is destructive, but the amount and type of evaporated material can readily be determined when using LAMMA in combination with transmission electron microscopy. Instrumental optimization and standardization of mass signals is possible by using platinum-loaded, ion chelating resin beads embedded and sectioned with the tissue.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200110404
|
|
|
“Ultrastructural localization of aluminum in patients with dialysis-associated osteomalacia”. Verbueken AH, van de Vijver FL, Van Grieken RE, Paulus GJ, Visser WJ, d'Haese P, de Broe ME, Clinical chemistry : international journal of laboratory medicine and molecular diagnostics 30, 763 (1984)
Abstract: Using laser microprobe mass analysis, we studied the ultrastructural localization of aluminum in liver and bone tissue of chronic-hemodialysis patients with proven aluminum-induced osteomalacia. In the liver, aluminum was observed to be almost exclusively associated with iron. Detectable aluminum and large amounts of iron were found in lysosomes of both hepatocytes and Kupffer cells. In bone, aluminum was localized at the osteoid/calcified-bone interface and also was associated with iron in some cases.
Keywords: A1 Journal article; Pharmacology. Therapy; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
van de Vijver FL, Verbueken AH, Van Grieken RE, de Broe ME, Visser WJ (1985) Laser microprobe mass analysis : a tool for evaluating histochemical staining of trace elements. 351–352
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis : a review of applications in the life sciences”. Verbueken AH, Bruynseels FJ, Van Grieken RE, Biomedical mass spectrometry 12, 438 (1985). http://doi.org/10.1002/BMS.1200120903
Abstract: The characteristics and analytical utility of laser microprobe mass analysis (LAMMA) are described and evaluated, and a short history of this recent microanalytical technique is presented. A review of the areas of application of LAMMA and related laser microprobes is presented with special emphasis on applications in the life sciences.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200120903
|
|
|
“Laser microprobe mass analysis (LAMMA) to verify the aluminon staining of bone”. Verbueken AH, van de Vijver FL, Visser WJ, Van Grieken RE, de Broe ME, Stain technology 61, 287 (1986). http://doi.org/10.3109/10520298609109955
Abstract: Triammonium aurin tricarboxylate (aluminon) has been used to localize aluminum in 2 μm sections of undecalcified, methyl methacrylate embedded bone obtained from patients with terminal chronic renal failure. Aluminum appeared in four cases as bright red lines at the mineralized-bone boundary. In two cases, however, purplish lines were found and one patient showed red as well as purplish lines. Laser microprobe mass analysis (LAMMA) identified aluminum at the location of the red lines and both aluminum and iron at the purplish lines. Furthermore, both iron and aluminum were found in histiocytic bone marrow cells, which showed brownish aluminon staining. It appears that when aluminum and iron occur together, aluminon staining may yield aberrant results. This study shows that LAMMA can be used for the identification of elements sought by histochemical methods and thus permits the evaluation of their staining effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.3109/10520298609109955
|
|
|
“Analysis of lateritic material from Cerro impacto by instrumental neutron activation employing a low-energy photon semiconductor and a high-energy Ge(Li) detector”. LaBrecque JJ, Beusen JM, Van Grieken RE, Applied spectroscopy 40, 140 (1986). http://doi.org/10.1366/0003702864509600
Abstract: Nineteen elements were determined in four different grain size fractions of a bulk geological material from Cerro Impacto for a study of the physical (mechanical) concentration process of different elements based upon the hardness of the different minerals. The analysis was performed by excitation of the sample with a high, slow neutron flux followed by gamma-ray spectroscopy with both a conventional Ge(Li) high-energy detector and a low-energy photon detector (LEPD). The accuracy of this method was studied with the use of two standard reference materials, SY-2 and SY-3, which are similar to the real samples. The values determined were also compared with a secondary target x-ray fluorescence method for all the elements that were suitable to both methods. Actually, the x-ray fluorescence method was found to be more complementary than competitive.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/0003702864509600
|
|
|
“Laser microprobe mass analysis (LAMMA) to study lead intoxication at the subcellular level”. Vandeputte DF, Verbueken AH, Jacob WA, Van Grieken RE, Acta pharmacologica et toxicologica 59, 617 (1986). http://doi.org/10.1111/J.1600-0773.1986.TB02840.X
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0773.1986.TB02840.X
|
|
|
“Applications of laser microprobe mass analysis in medicine”. Verbueken AH, van de Vijver FL, de Broe ME, Van Grieken RE, CRC critical reviews in clinical laboratory sciences 24, 263 (1987)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Composition and size of individual particles from a gold mine atmosphere”. Annegarn HJ, Storms H, Van Grieken RE, Booth-Jones PA, Mining science &, technology 5, 111 (1987). http://doi.org/10.1016/S0167-9031(87)90345-8
Abstract: Airborne dust particles were collected in a return airway of a South African gold mine using a 7-stage, single-orifice cascade impactor. Between 70 and 130 individual particles were analysed on each stage using automated electron-probe x-ray microanalysis (EPXMA). Particle size and shape parameters are given for different classes of particles sorted by elemental composition. Silicon-rich particles are the most abundant overall, while chlorine-rich particles dominate (up to 80%) in the range 0.21.0 μm. It is shown that EPXMA characterisation of particles can be used to infer relative contributions of various particle sources and dust generating processes to the total dust concentrations in mine atmospheres. An understanding of the nature and source of particles is essential for any source control strategy. We conclude that the EPXMA technique merits inclusion in the repertoire of techniques used for characterising underground dust.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0167-9031(87)90345-8
|
|