|
Caen J, Schalm O, Janssens K (2009) 15th century stained-glass windows in the former County of Flanders : a historical and chemical study related to recent conservation campaigns. 459–466
Keywords: P2 Proceeding; Engineering sciences. Technology; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
De Vis K, Cagno S, Van Mol W, Schalm O, Janssens K, Caen J (2012) The decolourization of manganese-stained glass : the conversion reaction and evaluation of its effectiveness. 463–468
Keywords: P2 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The consolidation of cracks in architectural glass and dalle de verre : first assessment of possible adhesives”. De Vis K, Jacobs P, Janssens K, Caen J, (2011)
Keywords: P3 Proceeding; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Bruijnen Y, Caen JMA, Cagno S, Janssens K, et al. (2012) Getekend Jan R. : Jan Rombouts, een renaissancemeester herontdekt. 207 p
Keywords: ME2 Book as editor or co-editor; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Manufacturing techniques and production defects of 16th-17th century majolica tiles from Antwerp (Belgium)”. Vandevijvere M, Van de Voorde L, Caen J, van Espen P, Vekemans B, Vincze L, Schalm O page 169 (2013).
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“Analiza pierwiastkowa zabytkowych obiektów szklanych”. Wagner B, Nowak A, Bulska E, Kunicki-Goldfinger J, Schalm O, Janssens K, Nauka i Zabytki , 71 (2008)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Contact sponge method : performance of a promising tool for measuring the initial water absorption”. Vandevoorde D, Pamplona M, Schalm O, Vanhellemont Y, Cnudde V, Verhaeven E, Journal of cultural heritage 10, 41 (2009). http://doi.org/10.1016/J.CULHER.2008.10.002
Abstract: Porous limestone and mortar are able to absorb large quantities of water. This phenomenon will accelerate the deterioration of the material. In such cases, the material might be treated with a hydrophobic product, which creates a superficial layer that hampers the penetration of water. In order to decide if such a treatment should be applied or not, the water absorbing behaviour of the material should be measured. With the same measuring technique the efficiency of the hydrophobic barrier can be evaluated. Moreover, it allows the monitoring of such barriers as a function of time. At the same time, the water absorption of porous stone material is an indication of the degree of deterioration and its sensitivity to future deterioration. Up to now, two different measuring techniques exist, but one can only be used in laboratory and the other, which can be operated in laboratory as well as in situ, is not always reliable for in situ analyses. This article proposes an alternative method: the contact sponge method. This recently developed method was tested on non-treated porous stone materials in a laboratory environment in order to evaluate its performance in comparison with the two existing methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CULHER.2008.10.002
|
|
|
“A GLUE uncertainty analysis of a drying model of pharmaceutical granules”. Mortier STFC, Van Hoey S, Cierkens K, Gernaey KV, Seuntjens P, De Baets B, De Beer T, Nopens I, European journal of pharmaceutics and biopharmaceutics 85, 984 (2013). http://doi.org/10.1016/J.EJPB.2013.03.012
Abstract: A shift from batch processing towards continuous processing is of interest in the pharmaceutical industry. However, this transition requires detailed knowledge and process understanding of all consecutive unit operations in a continuous manufacturing line to design adequate control strategies. This can be facilitated by developing mechanistic models of the multi-phase systems in the process. Since modelling efforts only started recently in this field, uncertainties about the model predictions are generally neglected. However, model predictions have an inherent uncertainty (i.e. prediction uncertainty) originating from uncertainty in input data, model parameters, model structure, boundary conditions and software. In this paper, the model prediction uncertainty is evaluated for a model describing the continuous drying of single pharmaceutical wet granules in a six-segmented fluidized bed drying unit, which is part of the full continuous from-powder-to-tablet manufacturing line (Consigma (TM), GEA Pharma Systems). A validated model describing the drying behaviour of a single pharmaceutical granule in two consecutive phases is used. First of all, the effect of the assumptions at the particle level on the prediction uncertainty is assessed. Secondly, the paper focuses on the influence of the most sensitive parameters in the model. Finally, a combined analysis (particle level plus most sensitive parameters) is performed and discussed. To propagate the uncertainty originating from the parameter uncertainty to the model output, the Generalized Likelihood Uncertainty Estimation (GLUE) method is used. This method enables a modeller to incorporate the information obtained from the experimental data in the assessment of the uncertain model predictions and to find a balance between model performance and data precision. A detailed evaluation of the obtained uncertainty analysis results is made with respect to the model structure, interactions between parameters and uncertainty boundaries. (C) 2013 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Pharmacology. Therapy; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1016/J.EJPB.2013.03.012
|
|
|
“The consolidation of cracks and fissures in dalle de verre : assessment of selected adhesives”. De Vis K, Caen J, Janssens K, Jacobs P page 43 (2013).
Abstract: Dalle de verre windows, created from 19301940 onwards, consist of glass pieces with a thickness of approximately 2 to 5 cm, set in a matrix of (reinforced) concrete. Besides the degradation of the concrete, the windows suffer mainly from a complex three-dimensional form of cracking of the glass elements. The cracks need to be consolidated in order to ensure stability and improve transparency. A selection of possible adhesives was evaluated: Araldite® 2020, Hxtal NYL-1, Fynebond, Paraloid® B-72, LV740, A18 and OR-G®. An attempt has been made to objectively compare these adhesives using a bench-marking system. None of the adhesives appears to be suitable for in situ application; sufficient penetration of the adhesives can only be realised with the help of vacuum techniques.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“The stained-glass panel depicting the anointing at Bethany : art historical research, technical analysis, and treatment”. Caen J, Cagno S, Janssens K page 247 (2013).
Abstract: In 2008, Museum M in Louvain (Flanders, Belgium) acquired a panel depicting The Anointing at Bethany that is believed once to have adorned the citys former Charterhouse. The panel required conservation treatment, which was preceded by a thorough art-historical and technical examination. It emerged that comparable panels are kept at the Metropolitan Museum of Art and the Riverside Church in New York. Chemical analyses show most of the glass in the panel to have a typical 16th century high-limelow-alkali composition. The conservation treatment was based on the evaluation of these findings and focused very strongly on enhancing the aesthetic balance for an improved reading of the panel.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“High-resolution desktop microcomputed tomography for the evaluation of reducing treatments on historical glass suffering from manganese browning”. Nuyts G, Cagno S, Jaroszewicz J, Wouters H, De Vis K, Caen J, Janssens K page 201 (2013).
Abstract: Historical glass, especially non-durable mediaeval glass, can undergo corrosion. This sometimes results in the formation of dark-coloured manganese-rich inclusions or stains that reduce the transparency of the glass. A conservation treatment with reducing or chelating agents may be considered with the aim of improving the transparency. In this paper, high-resolution desktop microcomputed tomography (µCT) is used in combination with element-specific twodimensional imaging methods for in situ monitoring of manganese removal by hydroxylamine hydrochloride from an archaeological stained-glass sample suffering from manganese browning and from artificially corroded model glass samples. µCT also proved itself useful for the study of the (re-)penetration of manganese into the gel layer during artificial corrosion of a model glass.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“Overview of most commonly used analytical techniques for elemental analysis”. Margui E, Van Grieken R, Petro Industry News , 8 (2014)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Awards for best referees of X-ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 68 (2014). http://doi.org/10.1002/XRS.2530
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2530
|
|
|
“Introducing John Campbell, the new regional editor for North America of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 67 (2014). http://doi.org/10.1002/XRS.2534
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2534
|
|
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
|
|
“A simple absorption correction for electron probe X-ray microanalysis of bulk samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 115 (1986). http://doi.org/10.1002/XRS.1300150209
Abstract: A simple procedure is proposed for the calculation of the absorption correction factor in electron-probe x-ray microanalysis. It is based on the concept of an effective depth of x-ray production, assuming a rectangular depth distribution function for x-ray generation. This effective x-ray production depth is expressed as a fraction of the x-ray excitation depth given by Whelan's expression. Adequate values for this fraction are presented. Two versions are considered. In the first the effective x-ray production is a function of both the characteristic x-ray energy and the atomic numbers of the matrix elements, whereas in the second one, which is indicated for routine use, the energy dependence is neglected. Calculations pointed to satisfactory results, even for low x-ray energies and high overvoltages.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150209
|
|
|
“Elemental analysis of aerosol-size fractions by proton-induced X-ray-emission”. Johansson TB, Nelson JW, Van Grieken RE, Winchester JW, Transactions of the American Nuclear Society 17, 103 (1973)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Elemental analysis of aerosols using proton-scattering”. Nelson JW, Williams I, Johansson TB, Van Grieken RE, IEEE transactions on nuclear science Ns21, 618 (1974). http://doi.org/10.1109/TNS.1974.4327522
Abstract: Elemental analysis for all of the light elements up through chlorine by elastic scattering of 16 MeV protons has been shown to be feasible. Basic problems associated with such measurements are discussed including kinematics, angular distribution, and sample backings. Spectra are presented for air particulate matter for both a total filter (Nuclepore) and a size fractionated air impactor (polystyrene backed) sample. The method is absolute, non destructive and can be used in conjunction with proton induced x-ray fluorescence to quantitatively analyze all elements in the same sample in minutes of time.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1109/TNS.1974.4327522
|
|
|
“Trace metal fractionation effects between sea water and aerosols from bubble bursting”. Van Grieken RE, Johansson TB, Winchester JW, Journal de recherches atmosphériques 8, 611 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Marine influences on aerosol composition in the coastal zone”. Johansson TB, Van Grieken RE, Winchester JW, Journal de recherches atmosphériques 8, 761 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Absorption correction for X-ray-fluorescence analysis of aerosol loaded filters”. Adams FC, Van Grieken RE, Analytical chemistry 47, 1767 (1975). http://doi.org/10.1021/AC60361A040
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60361A040
|
|
|
“Elemental trace analysis of small samples by proton-induced X-ray-emission”. Johansson TB, Van Grieken RE, Nelson JW, Winchester JW, Analytical chemistry 47, 855 (1975). http://doi.org/10.1021/AC60356A035
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60356A035
|
|
|
“Elemental abundance variation with particle-size in north florida aerosols”. Johansson TB, Van Grieken RE, Winchester JW, Journal of geophysical research 81, 1039 (1976). http://doi.org/10.1029/JC081I006P01039
Abstract: A nonurban base line has been established for nine trace element constituents of aerosol particles as a function of particle size at ground level sampling stations in north Florida up to 50 km from the Gulf of Mexico. The particle size range 0.25- to >4-μm aerodynamic diameter was investigated by cascade impactor sampling and elemental analysis by proton-induced X ray emission. By using a strategy of sampling at urban, forest, and coastal locations and by choosing approximately 48-hour sample averaging intervals the potential dependence of the base line levels both on local pollution and natural sources and on local particle size specific aerosol removal processes could be evaluated. It is found that elements contained in the largest particles, especially those of >4 μm, display the greatest degree of average concentration difference between sites, a result suggesting short atmospheric residence times and the importance of local dispersion sources and atmospheric cleansing processes in regulating the particle concentrations in air. Elements contained in particles of <2-μm diameter show little average concentration difference between sites unless they are influenced by local pollution sources, a finding suggesting that their concentrations in air are regulated by large-scale sources and transport processes. Sulfur in the smallest particles shows a marked constancy of concentration, but it may be modified in the largest particle size ranges in relation to proximity to the seacoast. No evidence is found for dependence of particulate sulfur concentrations on local pollution sources. K, Ca, Ti, Fe, and Zn appear to be regulated in the main by terrestrial source processes, and Cl by marine source processes, but Br and Pb appear to be accounted for adequately by assuming automotive fuel combustion as their major source. Limited data obtained for V indicate that it may vary considerably with fluctuations in aerosol transport from oil-fired electric power plant sources in the region. Limited additional data also suggest that Mn is derived from sources of natural terrestrial composition. In view of these findings, certain criteria may be set for the design of a meaningful nonurban aerosol monitoring network.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1029/JC081I006P01039
|
|
|
“Geophysical applicability of aerosol size distribution measurements using cascade impactors and proton-induced X-ray-emission”. Van Grieken RE, Johansson TB, Akselsson KR, Winchester JW, Nelson JW, Chapman KR, Atmospheric environment : an international journal 10, 571 (1976). http://doi.org/10.1016/0004-6981(76)90040-8
Abstract: Proton Induced X-ray Emission, (PIXE), is capable of high precision analysis for trace element components of aerosol particle size fractions sampled by cascade impactor. A statistical evaluation of data quality has been carried out in order to distinguish between analytical uncertainties in the PIXE procedure, errors caused by cascade impactor performance and by other factors in the sampling procedure, and geophysical causes of differences in composition and particle size distributions of the elements in aerosols. Replicate analyses and simultaneous samplings taken in north Florida and St. Louis have been used for the data evaluation. In addition to the analytical error the sampling procedure contributes an error of ~ 10% to be added quadratically. The resulting precision is sufficient to evaluate the data in geophysical terms. This is illustrated by means of sample sets taken simultaneously in an urban, forest and coastal environment of the same region.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(76)90040-8
|
|
|
“Filter absorption correction for X-ray fluorescence analysis of aerosol loaded filters”. Van Grieken R, Adams F, (1976)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Enrichment procedures for water analysis by X-ray energy spectrometry”. Van Grieken R, Bresseleers K, Smits J, Vanderborght B, Vanderstappen M, (1976)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Application of proton induced X-ray emission analysis to the St. Louis regional air pollution study”. Akselsson R, Orsini C, Meinert DL, Johansson TB, Van Grieken RE, Kaufmann HC, Chapman KR, Nelson JW, Winchester JW, (1976)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water”. Van Grieken RE, Bresseleers CM, Vanderborght BM, Analytical chemistry 49, 1326 (1977). http://doi.org/10.1021/AC50017A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50017A011
|
|
|
“Automated evaluation of photographically recorded spark-source mass spectra”. Vanderborght B, Van Grieken R, Analytica chimica acta 103, 223 (1978). http://doi.org/10.1016/S0003-2670(01)84041-1
Abstract: A computer routine was developed for qualitative and quantitative analysis of photographically recorded spark-source mass spectra. Particular attention is given to the case of a graphite matrix. The program starts from the line intensities (expressed as Seidel values) and isotope masses calculated from the densitometer readings by a commercially available routine. From the intensities in the different exposures (typically 15 stages), it computes the parameters for the linear parts of the density curves for each ion. Taking into account mutual interferences of multivalent ions, isotope or C-clusters, oxide, carbide and dicarbide ions, the program automatically identifies and then quantifies the elements present. The precision of the results is around 5%. Reading and complete processing of one photoplate is achieved within 23 h.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84041-1
|
|
|
“Spark-source mass-spectrometric sensitivity factors for elements in a graphite matrix”. Vanderborght B, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 26, 461 (1979). http://doi.org/10.1016/0039-9140(79)80111-3
Abstract: Relative sensitivity factors for determination of 41 elements by spark-source mass-spectrometry have been measured. The samples were pressed into graphite electrodes and ionized with a radiofrequency spark. The mass spectra were recorded on a photoplate and the resulting data processed by a computer. Indium was used as standard and the relative sensitivity factors for both singly- and doubly-charged ions were determined with reference to the singly-charged indium ion, with an overall error of 30%. The mean analysis precision was 16%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(79)80111-3
|
|