|
“Quantitative characterization of individual particle surfaces by fractal analysis of scanning electron microscope images”. van Put A, Vertes A, Wegrzynek D, Treiger B, Van Grieken R, Fresenius' journal of analytical chemistry 350, 440 (1994). http://doi.org/10.1007/BF00321787
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00321787
|
|
|
“Characterization of aerosol-associated lead by DPASV and LAMMA”. Wonders JHAM, Houweling S, de Bont FAJ, van Leeuwen HP, Eeckhaoudt SM, Van Grieken R, International journal of environmental analytical chemistry 56, 193 (1994). http://doi.org/10.1080/03067319408034100
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319408034100
|
|
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
|
|
“The use of potentiometric sensors to study (bio)molecular interactions”. De Wael K, Daems D, Van Camp G, Nagels LJ, Analytical chemistry 84, 4921 (2012). http://doi.org/10.1021/AC3005428
Abstract: Potentiometric sensors were used to study molecular interactions in liquid environments, with sensorgram methodology. This is demonstrated with a lipophilic rubber-, and with a collagen based hydrogel sensor coating. The investigated molecules were promazine and tartaric acid respectively. The sensors were placed in a hydrodynamic wall jet system for the recording of sensorgrams. mV sensor responses were first converted to a signal, expressing the concentration of adsorbed organic ions. Using a linearization method, a pseudo first order kinetic model of adsorption was shown to fit the experimental results perfectly. Kass, kon and koff values were calculated.. The technique can be used over 4 decades of concentration, and it is very sensitive to low MW compounds as well as to multiply charged large biomolecules. This study is the first to demonstrate the application of potentiometric sensors as an alternative and complement to SPR methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 10
DOI: 10.1021/AC3005428
|
|
|
“Aptasensing of chloramphenicol in the presence of its analogues : reaching the maximum residue limit”. Pilehvar S, Mehta J, Dardenne F, Robbens J, Blust R, De Wael K, Analytical chemistry 84, 6753 (2012). http://doi.org/10.1021/AC3012522
Abstract: A novel label-free folding induced aptamer-based electrochemical biosensor for the detection of chloramphenicol (CAP) in the presence of its analogues has been developed. CAP is a broad-spectrum antibiotic which has lost its favor due to its serious adverse toxic effects on human health. Aptamers are artificial nucleic acid ligands (ssDNA or RNA) able to specifically recognize a target such as CAP. In this article, the aptamers are fixed onto a gold electrode surface by a self-assembly approach. In the presence of CAP, the unfolded ssDNA on the electrode surface changes to a hairpin structure bringing the target molecules close to the surface and trigger electron transfer. Detection limits were determined to be 1.6×10-9 mol L-1. In addition, thiamphenicol (TAP) and florfenicol (FF), antibiotics with a similar structure to CAP, did not influence the performance of the aptasensor, suggesting a good selectivity of the CAP-aptasensor. Simplicity and lower detection limit (because of the home-selected aptamers) make that the electrochemical aptasensor is suitable for practical use in the detection of CAP in milk samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 68
DOI: 10.1021/AC3012522
|
|
|
“Fast steel-cleanness characterization by means of laser-assisted plasma spectrometric methods”. Mueller G, Stahnke F, Bleiner D, Talanta : the international journal of pure and applied analytical chemistry
T2 –, 34th Colloquium Spectroscopicum Internationale, SEP 04-09, 2005, Univ Antwerp, Antwerp, BELGIUM (2006). http://doi.org/10.1016/J.TALANTA.2006.05.047
Abstract: Laser-assisted plasma spectrometry is a palette of analytical techniques (L-OES, LA-ICP-MS) capable of fast spatially-resolved elemental analysis in the micrometer range. For fast estimation of the occurrence in steel samples of non-metallic inclusions, which degrade the material's technical properties, simultaneous OES detection and sequential ICP-MS detection were compared. Histograms were obtained for the intensity distribution of the acquired signals (laser pulse statistics). The skewness coefficient of the histograms for Al (indicator of non-metallic inclusions) was found to be clearly dependent on the fraction of non-metallic inclusions in the case of scanning L-OES. For LA-ICP-MS less clear dependence was observed, which was influenced by the acquisition characteristics. In fact, less measurement throughput limited for LA-ICP-MS the counting statistics to an extent that overrides the benefit of higher detection power as compared to L-OES. (c) 2006 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
Times cited: 12
DOI: 10.1016/J.TALANTA.2006.05.047
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 85, 670 (2013). http://doi.org/10.1021/ac3031459
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 29
DOI: 10.1021/ac3031459
|
|
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of spectromicroscopic methods : 3 : synthesis, characterization, and detection of different crystal forms of the chrome yellow pigment”. Monico L, Janssens K, Miliani C, Brunetti BG, Vagnini M, Vanmeert F, Falkenberg G, Abakumov A, Lu Y, Tian H, Verbeeck J, Radepont M, Cotte M, Hendriks E, Geldof M, van der Loeff L, Salvant J, Menu M;, Analytical chemistry 85, 860 (2013). http://doi.org/10.1021/ac302158b
Abstract: The painter, Vincent van Gogh, and some of his contemporaries frequently made use of the pigment chrome yellow that is known to show a tendency toward darkening. This pigment may correspond to various chemical compounds such as PbCrO4 and PbCr1-xSxO4, that may each be present in various crystallographic forms with different tendencies toward degradation. Investigations by X-ray diffraction (XRD), mid-Fourier Transform infrared (FTIR), and Raman instruments (benchtop and portable) and synchrotron radiation-based micro-XRD and X-ray absorption near edge structure spectroscopy performed on oil-paint models, prepared with in-house synthesized PbCrO4 and PbCr1-xSxO4, permitted us to characterize the spectroscopic features of the various forms. On the basis of these results, an extended study has been carried out on historic paint tubes and on embedded paint microsamples taken from yellow-orange/pale yellow areas of 12 Van Gogh paintings, demonstrating that Van Gogh effectively made use of different chrome yellow types. This conclusion was also confirmed by in situ mid-FTIR investigations on Van Goghs Portrait of Gauguin (Van Gogh Museum, Amsterdam).
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 79
DOI: 10.1021/ac302158b
|
|
|
“Relative evaluation of neutron activation, X-ray fluorescence and spark source mass spectrometry for multi-element analysis of geothermal waters”. Blommaert W, Vandelannoote R, Van 't dack L, Gijbels R, van Grieken R, Journal of radioanalytical chemistry 57, 382 (1980)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Equilibrium constants for trace elements in natural waters”. Van 't dack L, Blommaert W, Vandelannoote R, Gijbels R, van Grieken R, Reviews in analytical chemistry 7, 297 (1983)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Unique opto-electronic structure and photo reduction properties of sulfur doped lead chromates explaining their instability in paintings”. Rahemi V, Sarmadian N, Anaf W, Janssens K, Lamoen D, Partoens B, De Wael K, Analytical chemistry 89, 3326 (2017). http://doi.org/10.1021/ACS.ANALCHEM.6B03803
Abstract: Chrome yellow refers to a group of synthetic inorganic pigments that became popular as an artists material from the second quarter of the 19th century. The color of the pigment, in which the chromate ion acts as a chromophore, is related to its chemical composition (PbCr1-xSxO4, with 0≤x≤0.8) and crystalline structure (monoclinic/orthorhombic). Their shades range from the yellow-orange to the paler yellow tones with increasing sulfate amount. These pigments show remarkable signs of degradation after limited time periods. Pure PbCrO4 (crocoite in its natural form) has a deep yellow color and is relatively stable, while the co-precipitate with lead sulfate (PbCr1-xSxO4) has a paler shade and seems to degrade faster. This degradation is assumed to be related to the reduction of Cr(VI) to Cr(III). We show that on increasing the sulfur(S)-content in chrome yellow, the band gap increases. Typically, when increasing the band gap, one might assume that a decrease in photo activity is the result. However, the photo activity relative to the Cr content, and thus Cr reduction, of sulfur-rich PbCr1-xSxO4 is found to be much higher compared to the sulfur-poor or non-doped lead chromates. This discrepancy can be explained by the evolution of the crystal and electronic structure as function of the sulfur content: first-principles density functional theory calculations show that both the absorption coefficient and reflection coefficients of the lead chromates change as a result of the sulfate doping in such a way that the generation of electron-hole pairs under illumination relative to the total Cr content increases. These changes in the material properties explain why paler shade yellow colors of this pigment are more prone to discoloration. The electronic structure calculations also demonstrate that lead chromate and its co-precipitates are p-type semiconductors, which explains the observed reduction reaction. As understanding this phenomenon is valuable in the field of cultural heritage, this study is the first joint action of photo-electrochemical measurements and first-principles calculations to approve the higher tendency of sulfur-rich lead chromates to darken.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 7
DOI: 10.1021/ACS.ANALCHEM.6B03803
|
|
|
“Mathematical description of a direct current glow discharge in argon”. Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 355, 853 (1996)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 12
|
|
|
“Two-dimensional model of a direct current glow discharge: description of the electrons, argon ions and fast argon atoms”. Bogaerts A, Gijbels R, Goedheer WJ, Analytical chemistry 68, 2296 (1996). http://doi.org/10.1021/ac9510651
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 70
DOI: 10.1021/ac9510651
|
|
|
“Two-dimensional model of a direct current glow discharge : description of the argon metastable atoms, sputtered atoms and ions”. Bogaerts A, Gijbels R, Analytical chemistry 68, 2676 (1996). http://doi.org/10.1021/ac951206z
Abstract: A two-dimensional model is presented that describes the behavior of argon metastable atoms, copper atoms, and copper ions in an argon direct. current glow discharge, in the standard cell of the VG9000 glow discharge mass spectrometer for analyzing flat samples. The model is combined with a previously developed model for the electrons, argon ions, and atoms in the same cell to obtain an overall picture of the glow discharge, The results of the present model comprise the number densities of the described plasma species, the relative contributions of different production and loss processes for the argon metastable atoms, the thermalization profile of the sputtered copper atoms, the relative importance of the different ionization mechanisms for the copper atoms, the ionization degree of copper, the copper ion-to-argon ion density ratio, and the relative roles of copper ions, argon ions, and atoms in the sputtering process. All these quantities are calculated for a range of voltages and pressures, Moreover, since the sticking coefficient of copper atoms on solid surfaces is not well-known in the literature, the influence of this parameter on the results is briefly discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 57
DOI: 10.1021/ac951206z
|
|
|
“Three-dimensional chemical characterization of complex silver halide microcrystals by scanning ion microprobe mass analysis”. Verlinden G, Janssens G, Gijbels R, van Espen P, Geuens I, Analytical chemistry 69, 3773 (1997). http://doi.org/10.1021/ac970010r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 6
DOI: 10.1021/ac970010r
|
|
|
“Microprobe speciation analysis of inorganic solids by Fourier transform laser mass spectrometry”. Poels K, van Vaeck L, Gijbels R, Analytical chemistry 70, 504 (1998). http://doi.org/10.1021/ac9709108
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 32
DOI: 10.1021/ac9709108
|
|
|
“Recent trends in solids mass spectrometry: GDMS and other methods”. Gijbels R, Bogaerts A, Fresenius' journal of analytical chemistry 359, 326 (1997). http://doi.org/10.1007/s002160050581
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 5
DOI: 10.1007/s002160050581
|
|
|
“Three-dimensional modeling of a direct current glow discharge in argon: is it better than one-dimensional modeling?”.Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 359, 331 (1997). http://doi.org/10.1007/s002160050582
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 9
DOI: 10.1007/s002160050582
|
|
|
“Modeling of glow discharges: what can we learn from it?”.Bogaerts A, Gijbels R, Analytical chemistry A-pages 69, 719 (1997)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Automated particle analysis of populations of silver halide microcrystals by electron probe microanalysis under cryogenic conditions”. Gregory CL, Nullens HA, Gijbels RH, van Espen PJ, Geuens I, de Keyzer R, Analytical chemistry 70, 2551 (1998). http://doi.org/10.1021/ac9710644
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 12
DOI: 10.1021/ac9710644
|
|
|
“New developments and applications in GDMS”. Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 364, 367 (1999). http://doi.org/10.1007/s002160051352
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 17
DOI: 10.1007/s002160051352
|
|
|
“Modeling of the sputtering process of cubic silver halide microcrystals and its relevance in depth profiling by secondary ion-mass spectrometry (SIMS)”. Lenaerts J, Verlinden G, Ignatova VA, van Vaeck L, Gijbels R, Geuens I, Fresenius' journal of analytical chemistry 370, 654 (2001). http://doi.org/10.1007/s002160100880
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 3
DOI: 10.1007/s002160100880
|
|
|
“Design and development of a new program for data processing of mass spectra acquired by means of a high-resolution double-focusing glow-discharge mass spectrometer”. Robben J, Dufour D, Gijbels R, Fresenius' journal of analytical chemistry 370, 663 (2001). http://doi.org/10.1007/s002160100881
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 2
DOI: 10.1007/s002160100881
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 74, 2691 (2002). http://doi.org/10.1021/ac020190r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 18
DOI: 10.1021/ac020190r
|
|
|
“Influence of axial and radial diffusion processes on the analytical performance of a glow discharge cell”. van Straaten M, Gijbels R, Vertes A, Analytical chemistry 64, 1855 (1992). http://doi.org/10.1021/ac00041a021
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 43
DOI: 10.1021/ac00041a021
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 76, 3313 (2004). http://doi.org/10.1021/ac040052x
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 32
DOI: 10.1021/ac040052x
|
|
|
“Metal-assisted secondary ion mass spectrometry: the influence of Ag and Au deposition on molecular ion yields”. Adriaensen L, Vangaever F, Gijbels R, Analytical chemistry 76, 6777 (2004). http://doi.org/10.1021/ac049108d
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 67
DOI: 10.1021/ac049108d
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 78, 3917 (2006). http://doi.org/10.1021/ac060597m
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 112
DOI: 10.1021/ac060597m
|
|
|
“Colloquium Spectroscopicum Internationale 34, Antwerp, Belgium, 4-9 September 2005: preface”. Janssens K, Bogaerts A, van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 70, 907 (2006). http://doi.org/10.1016/j.talanta.2006.05.044
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
DOI: 10.1016/j.talanta.2006.05.044
|
|
|
“Hydrodynamic model of matrix-assisted laser desorption mass spectrometry”. Vertes A, Irinyi G, Gijbels R, Analytical chemistry 65, 2389 (1993). http://doi.org/10.1021/ac00065a036
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 100
DOI: 10.1021/ac00065a036
|
|