|
“Elemental trace analysis of small samples by proton-induced X-ray-emission”. Johansson TB, Van Grieken RE, Nelson JW, Winchester JW, Analytical chemistry 47, 855 (1975). http://doi.org/10.1021/AC60356A035
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60356A035
|
|
|
“Absorption correction for X-ray-fluorescence analysis of aerosol loaded filters”. Adams FC, Van Grieken RE, Analytical chemistry 47, 1767 (1975). http://doi.org/10.1021/AC60361A040
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60361A040
|
|
|
“Marine influences on aerosol composition in the coastal zone”. Johansson TB, Van Grieken RE, Winchester JW, Journal de recherches atmosphériques 8, 761 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace metal fractionation effects between sea water and aerosols from bubble bursting”. Van Grieken RE, Johansson TB, Winchester JW, Journal de recherches atmosphériques 8, 611 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Elemental analysis of aerosols using proton-scattering”. Nelson JW, Williams I, Johansson TB, Van Grieken RE, IEEE transactions on nuclear science Ns21, 618 (1974). http://doi.org/10.1109/TNS.1974.4327522
Abstract: Elemental analysis for all of the light elements up through chlorine by elastic scattering of 16 MeV protons has been shown to be feasible. Basic problems associated with such measurements are discussed including kinematics, angular distribution, and sample backings. Spectra are presented for air particulate matter for both a total filter (Nuclepore) and a size fractionated air impactor (polystyrene backed) sample. The method is absolute, non destructive and can be used in conjunction with proton induced x-ray fluorescence to quantitatively analyze all elements in the same sample in minutes of time.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1109/TNS.1974.4327522
|
|
|
“Elemental analysis of aerosol-size fractions by proton-induced X-ray-emission”. Johansson TB, Nelson JW, Van Grieken RE, Winchester JW, Transactions of the American Nuclear Society 17, 103 (1973)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“A simple absorption correction for electron probe X-ray microanalysis of bulk samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 115 (1986). http://doi.org/10.1002/XRS.1300150209
Abstract: A simple procedure is proposed for the calculation of the absorption correction factor in electron-probe x-ray microanalysis. It is based on the concept of an effective depth of x-ray production, assuming a rectangular depth distribution function for x-ray generation. This effective x-ray production depth is expressed as a fraction of the x-ray excitation depth given by Whelan's expression. Adequate values for this fraction are presented. Two versions are considered. In the first the effective x-ray production is a function of both the characteristic x-ray energy and the atomic numbers of the matrix elements, whereas in the second one, which is indicated for routine use, the energy dependence is neglected. Calculations pointed to satisfactory results, even for low x-ray energies and high overvoltages.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150209
|
|
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
|
|
“Introducing John Campbell, the new regional editor for North America of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 67 (2014). http://doi.org/10.1002/XRS.2534
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2534
|
|
|
“Awards for best referees of X-ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 68 (2014). http://doi.org/10.1002/XRS.2530
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2530
|
|
|
“Overview of most commonly used analytical techniques for elemental analysis”. Margui E, Van Grieken R, Petro Industry News , 8 (2014)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“All crystal clear : 18th-century glass à, la façon de Bohème from the cistercian nunnery of Clairefontaine, Belgium”. Herremans D, Cagno S, Vincke A, Janssens K, De Clercq W, Journal of glass studies 55, 137 (2013)
Abstract: Excavations at the Cistercian nunnery of Clairefontaine, located near Arlon in the south of Belgium, revealed an assemblage of 18th-century colorless glass. The morphology of the vessels and the engraved decoration suggest a central European origin or, at least, stylistic inspiration. The composition of the glass points to a recipe combining silica, lime, and potash: a colorless potash glass a la facon de Boheme. This article considers the technology, morphology, and origin of the vessels. The art-historical analysis is supported by chemical research (scanning electron microscopy energy-dispersive X-ray spectroscopy [SEM-EDX]). The finds are also discussed in light of the emerging northwestern European glass industry, changing consumer practices during the 18th century, and their meaning for the inhabitants of the abbey.
Keywords: A1 Journal article; Art; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“High-resolution desktop microcomputed tomography for the evaluation of reducing treatments on historical glass suffering from manganese browning”. Nuyts G, Cagno S, Jaroszewicz J, Wouters H, De Vis K, Caen J, Janssens K page 201 (2013).
Abstract: Historical glass, especially non-durable mediaeval glass, can undergo corrosion. This sometimes results in the formation of dark-coloured manganese-rich inclusions or stains that reduce the transparency of the glass. A conservation treatment with reducing or chelating agents may be considered with the aim of improving the transparency. In this paper, high-resolution desktop microcomputed tomography (µCT) is used in combination with element-specific twodimensional imaging methods for in situ monitoring of manganese removal by hydroxylamine hydrochloride from an archaeological stained-glass sample suffering from manganese browning and from artificially corroded model glass samples. µCT also proved itself useful for the study of the (re-)penetration of manganese into the gel layer during artificial corrosion of a model glass.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“The stained-glass panel depicting the anointing at Bethany : art historical research, technical analysis, and treatment”. Caen J, Cagno S, Janssens K page 247 (2013).
Abstract: In 2008, Museum M in Louvain (Flanders, Belgium) acquired a panel depicting The Anointing at Bethany that is believed once to have adorned the citys former Charterhouse. The panel required conservation treatment, which was preceded by a thorough art-historical and technical examination. It emerged that comparable panels are kept at the Metropolitan Museum of Art and the Riverside Church in New York. Chemical analyses show most of the glass in the panel to have a typical 16th century high-limelow-alkali composition. The conservation treatment was based on the evaluation of these findings and focused very strongly on enhancing the aesthetic balance for an improved reading of the panel.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“The consolidation of cracks and fissures in dalle de verre : assessment of selected adhesives”. De Vis K, Caen J, Janssens K, Jacobs P page 43 (2013).
Abstract: Dalle de verre windows, created from 19301940 onwards, consist of glass pieces with a thickness of approximately 2 to 5 cm, set in a matrix of (reinforced) concrete. Besides the degradation of the concrete, the windows suffer mainly from a complex three-dimensional form of cracking of the glass elements. The cracks need to be consolidated in order to ensure stability and improve transparency. A selection of possible adhesives was evaluated: Araldite® 2020, Hxtal NYL-1, Fynebond, Paraloid® B-72, LV740, A18 and OR-G®. An attempt has been made to objectively compare these adhesives using a bench-marking system. None of the adhesives appears to be suitable for in situ application; sufficient penetration of the adhesives can only be realised with the help of vacuum techniques.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“Contact sponge method : performance of a promising tool for measuring the initial water absorption”. Vandevoorde D, Pamplona M, Schalm O, Vanhellemont Y, Cnudde V, Verhaeven E, Journal of cultural heritage 10, 41 (2009). http://doi.org/10.1016/J.CULHER.2008.10.002
Abstract: Porous limestone and mortar are able to absorb large quantities of water. This phenomenon will accelerate the deterioration of the material. In such cases, the material might be treated with a hydrophobic product, which creates a superficial layer that hampers the penetration of water. In order to decide if such a treatment should be applied or not, the water absorbing behaviour of the material should be measured. With the same measuring technique the efficiency of the hydrophobic barrier can be evaluated. Moreover, it allows the monitoring of such barriers as a function of time. At the same time, the water absorption of porous stone material is an indication of the degree of deterioration and its sensitivity to future deterioration. Up to now, two different measuring techniques exist, but one can only be used in laboratory and the other, which can be operated in laboratory as well as in situ, is not always reliable for in situ analyses. This article proposes an alternative method: the contact sponge method. This recently developed method was tested on non-treated porous stone materials in a laboratory environment in order to evaluate its performance in comparison with the two existing methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CULHER.2008.10.002
|
|
|
“Analiza pierwiastkowa zabytkowych obiektów szklanych”. Wagner B, Nowak A, Bulska E, Kunicki-Goldfinger J, Schalm O, Janssens K, Nauka i Zabytki , 71 (2008)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Manufacturing techniques and production defects of 16th-17th century majolica tiles from Antwerp (Belgium)”. Vandevijvere M, Van de Voorde L, Caen J, van Espen P, Vekemans B, Vincze L, Schalm O page 169 (2013).
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
Bruijnen Y, Caen JMA, Cagno S, Janssens K, et al. (2012) Getekend Jan R. : Jan Rombouts, een renaissancemeester herontdekt. 207 p
Keywords: ME2 Book as editor or co-editor; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The consolidation of cracks in architectural glass and dalle de verre : first assessment of possible adhesives”. De Vis K, Jacobs P, Janssens K, Caen J, (2011)
Keywords: P3 Proceeding; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
De Vis K, Cagno S, Van Mol W, Schalm O, Janssens K, Caen J (2012) The decolourization of manganese-stained glass : the conversion reaction and evaluation of its effectiveness. 463–468
Keywords: P2 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Caen J, Schalm O, Janssens K (2009) 15th century stained-glass windows in the former County of Flanders : a historical and chemical study related to recent conservation campaigns. 459–466
Keywords: P2 Proceeding; Engineering sciences. Technology; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“LA-ICP-MS for Pu source identification at Mayak PA, the Urals, Russia”. Cagno S, Hellemans K, Lind OC, Skipperud L, Janssens K, Salbu B, Environmental science : processes &, impacts 16, 306 (2014). http://doi.org/10.1039/C3EM00531C
Abstract: Information on Pu in environmental samples is traditionally based on the determination of the 240+239PU activity via Alpha Spectrometry (AS). A large number of alpha spectrometry sources (planchettes) containing radiochemically separated Pu are therefore stored worldwide and are available for further analyses. These archive samples represent a resource from which valuable information on isotopic composition of alpha emitters including Pu can be obtained. The relative abundances of Pu isotopes can be used to trace specific Pu sources and characterize the relative contributions of different Pu sources in a sample. Thus, in addition to the total 239+240PU activity, determination of the Pu-240/Pu-239 ratio can provide valuable information on the nature of the Pu emitting sources. The Pu isotopic ratios can be determined by mass spectrometry techniques such as Sector Field Inductively Coupled Plasma Mass Spectrometry (SF-ICPMS) or Accelerator Mass Spectrometry (AMS) that require dissolution and complete destruction of the material deposited on the planchettes. In this study Laser Ablation (LA)-quadrupole-ICP-MS has been employed for the analysis of Pu-239/Pu-240 ratios from alpha-planchettes prepared from samples originating from the Mayak PA nuclear facility, Russia. The results are compared with data from AMS and show that the Pu-240/Pu-239 ratios obtained by LA-ICP-MS can be utilized to distinguish weapons-grade Pu from civil reprocessing sources. Moreover, isotope ratio mapping can also be performed across the planchettes, allowing e.g. the visualization of possible inhomogeneities in the Pu-isotope distribution on their surface. Thus, this solid sample technique can be applied to extract additional information from existing archives of samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.592
Times cited: 10
DOI: 10.1039/C3EM00531C
|
|
|
“Deeply colored and black-appearing Roman glass : a continued research”. Cagno S, Cosyns P, Izmer A, Vanhaecke F, Nys K, Janssens K, Journal of archaeological science 42, 128 (2014). http://doi.org/10.1016/J.JAS.2013.11.003
Abstract: In the context of archaeological and historical assessment of Roman black-appearing glass, the chemical and physical characterization of a large collection of samples originating from various areas of the Roman Empire has been gathered over the past years to (i) verify whether a minor segment of the overall Roman glass production can help in determining possible diachronic changes in Roman imperial glass production (1st century AD – 5th century AD) and (ii) reveal regional compositional differences. In this paper, the latest results on the chemical composition of an additional 44 black-appearing Roman glass samples are presented, together with general conclusions based upon the entire compositional dataset of over 400 analyzed black glass samples. The results show that the Roman black glass is obtained through several glass compositions with a specific chronological, geographical and typological distribution. (C) 2013 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Philosophy; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.602
Times cited: 18
DOI: 10.1016/J.JAS.2013.11.003
|
|
|
“The determination of copper in iron and steel by 14-Mev neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 51, 151 (1970). http://doi.org/10.1016/S0003-2670(01)95703-4
Abstract: A fast (10 min) non-destructive determination of copper in. steel and cast iron by 14-MeV neutron activation analysis is described. The 0.511-MeV annihilation radiation of62Cu (T1/2=9.8 min), induced by the reaction63Cu(n,2n)62Cu, is counted by two opposing NaI(Tl) detectors operating in coincidence. An oxygen flux monitor is used to normalise the irradiations. For high phosphorus contents, two measurements are made and the 9-min activity contribution is calculated. As the iron content of the samples is known, the use of pure iron samples allows correction for53Fe activity from the reaction54Fe(n,2n)53Fe(T1/2= 8.9 min). When the phosphorus and silicon activities are low, the procedure of counting and computing can be greatly simplified. Nuclear interferences of most common alloying and impurity elements were investigated.The precision is 23% for steels containing above 1% Cu, andCa. 10% for 0.1%Cu.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95703-4
|
|
|
“On the precision of oxygen determinations in steel by 14-MeVv neutron activation”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 52, 275 (1970). http://doi.org/10.1016/S0003-2670(01)80957-0
Abstract: The precision of the 14-MeV neutron activation determination of oxygen in steel has been examined as a function of the oxygen content for a large number of steel and cast iron samples. The experimental and the statistically expected standard deviations have been compared. In the conditions used, 2.5 counts from 16N were registered for each p.p.m. of oxygen in the samples. The neutron flux was monitored by a simultaneously irradiated oxygen standard.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)80957-0
|
|
|
“Simultaneous determination of chromium and silicon in steel by 14-mev neutron activation analysis”. Vandecasteele C, Van Grieken R, Hoste J, Analytica chimica acta 72, 31 (1974). http://doi.org/10.1016/S0003-2670(01)82945-7
Abstract: Chromium and silicon are determined simultaneously in steel by 14-MeV neutron activation analysis. The activities of 52V(Eγ=1.43 MeV,TView the MathML source=3.76 min) from 52Cr(n,p)52V and 28Al (Eγ=1.78 MeV; TView the MathML source=2.24 min) from 28Si(n,p)28Al are evaluated by mixed γ-ray spectrometry. The influence of manganese and phosphorus, the main interfering elements, is negligible for most stainless steels. The count rate should be limited, to avoid 52V pulse pile-up effects interfering in the 28Al energy region. Precisions in the 2-10% range are reached, depending on the concentrations, for a 10-min analysis time. Results for a series of steel samples are compared with industrial analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)82945-7
|
|
|
“Optimization of a simple spotting procedure for x-ray fluorescence analysis of waters”. Smits J, Van Grieken R, Analytica chimica acta 88, 97 (1977). http://doi.org/10.1016/S0003-2670(01)96053-2
Abstract: Several sample preparation methods for waters for energy-dispersive x.r.f. were examined, as well as the influence of sample size on the analytical characteristics. The most satisfactory simple, rapid method proved to be spotting of 1.5 ml of water sample on a Whatman-41 cellulose filter paper provided with a wax ring of 29-mm diameter and evaporating the water with an unheated air stream from underneath. Sensitivities are below 100 p.p.b. for most elements and often below 50 p.p.b. when the optimal secondary fluorescer is used. Accuracy and precision are usually in the 1520 % range. The method is applicable to many dilute aqueous solutions as is illustrated by analysis of industrial water samples and ashed biological material.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)96053-2
|
|
|
“Reduction of trace metal levels in analytical-grade activated carbon”. Vanderborght B, Van Grieken R, Analytica chimica acta 89, 399 (1977). http://doi.org/10.1016/S0003-2670(01)84739-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84739-5
|
|
|
“Comparison of preconcentration procedures for trace metals in natural waters”. Smits J, Nelissen J, Van Grieken R, Analytica chimica acta 111, 215 (1979). http://doi.org/10.1016/S0003-2670(01)93264-7
Abstract: The relative merits of eight procedures for preconcentrations of trace metal ions from natural water samples and synthetic solutions are evaluated. Spikes (100 μg l−1 ) of Mn, Co, Zn, Eu, Cs and Ba and the corresponding radioactive tracers were added to batches of drinking water, estuarine water, sea water, ground water, twice-distilled water and ahumic material solution. After equilibration for 25 months, the following techniques were applied: passage through columns of Dowex Al chelating resin and ofsilylated silica gel, filtration through laminate membrane filters and chelating diethylenetriamine cellulose filters, precipitation with sodium diethyldithiocarbamate and l-(2-pyridylazo)-2-naphthol, extraction with ammonium pyrrolidinedithiocarbamate, and chelation by 8-quinolinol (oxine) followed by adsorption on activated carbon. The quantitative characteristics of these techniques and the influence of the water matrix effects are discussed, as well as the applicability for x-ray fluorescence analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93264-7
|
|