|
“Laser microprobe mass spectrometry in biology and biomedicine”. Eeckhaoudt S, van Vaeck L, Gijbels R, van Grieken RE, Scanning microscopy S8, 335 (1994)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
|
|
“Colloquium Spectroscopicum Internationale 34, Antwerp, Belgium, 4-9 September 2005: preface”. Janssens K, Bogaerts A, van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 70, 907 (2006). http://doi.org/10.1016/j.talanta.2006.05.044
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
DOI: 10.1016/j.talanta.2006.05.044
|
|
|
“Colloquium Spectroscopicum Internationale 34: a collection of papers presented at the Colloquium Spectroscopicum Internationale, Antwerp, Belgium, 4-9 September 2005”. Janssens K, Bogaerts A, van Grieken R Elsevier, Amsterdam (2006).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Editorial”. van Grieken R, Bogaerts A, Janssens K, Spectrochimica acta: part A: molecular spectroscopy 64, 1089 (2006). http://doi.org/10.1016/j.saa.2006.05.011
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.536
DOI: 10.1016/j.saa.2006.05.011
|
|
|
“Colloquium Spectroscopicum Internationale 34, Antwerp (Belgium), 4-9 September 2005: preface”. Bogaerts A, Janssens K, van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 61, 373 (2006). http://doi.org/10.1016/j.sab.2006.04.011
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 2
DOI: 10.1016/j.sab.2006.04.011
|
|
|
“Colloquium Spectroscopicum Internationale 34 (CSI 34), Antwerp, Belgium, 4-9 September 2005”. Bogaerts A, Janssens K, van Grieken R Elsevier, Amsterdam (2006).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Controlled formation of amine-templated mesostructured zirconia with remarkably high thermal stability”. Cassiers K, Linssen T, Aerts K, Cool P, Lebedev O, Van Tendeloo G, van Grieken R, Vansant EF, Journal of materials chemistry 13, 3033 (2003). http://doi.org/10.1039/b310200a
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 26
DOI: 10.1039/b310200a
|
|
|
“Analysis of nonconducting materials by dc glow discharge spectrometry”. Bogaerts A, Schelles W, van Grieken R Wiley, Chichester, page 293 (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Inorganic mass spectrometry”. Adams F, Gijbels R, van Grieken R, Kim Y-sang Freedom Academy Press, Seoul (1999).
Keywords: ME3 Book as editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Adams F, Gijbels R, Van Grieken R, Dachang Z (1993) Inorganic mass spectrometry. Fudan University Press, Shanghai, 391 p
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Mass spectrometry, inorganic”. Adams F, Gijbels R, Jambers W, van Grieken R Wiley, Chichester, page 2650 (1998).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Chemical characterization of neo-ceramic powders by time-of-flight and Fourier transform laser microprobe mass spectrometry”. Struyf H, van Vaeck L, Kennis P, Gijbels R, van Grieken R, Rapid communications in mass spectrometry 10, 699 (1996). http://doi.org/10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
Abstract: Laser microprobe mass spectrometry (LMMS) aims at the identification of local organic and inorganic constituents at the surface of solids, The low mass resolution capabilities of the initially used time-of-flight (TOF) mass spectrometers have often proved to be insufficient for identification, Therefore, high mass resolution Fourier transform (ET) LMMS was developed, Neo-ceramic powders with oxide or carbide coatings were analyzed by both FT LMMS and TOF LMMS, The data are useful to compare the analytical information gained from both methods, Analytical results of these samples by electron microprobe x-ray analysis (EPXMA) and secondary ion mass spectrometry (SIMS) are discussed to assess the place of FT LMMS and TOF LMMS in the spectrum of microanalytical techniques.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.253
Times cited: 11
DOI: 10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
|
|
|
Gijbels R, van Grieken R (1985) Trace element geochemistry in thermal waters from the Eastern Pyrenees. S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Gijbels R, van Grieken R, Blommaert W, Van 't dack L, van Espen P, Nullens H, Saelens R (1983) Application of analytical methods for trace elements in geothermal waters : part 2 : Plombières, Bains-les-Bains, Bourbonne (Vosges). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
Gijbels R, van Grieken R (1977) Application of analytical methods for trace elements in geothermal waters : part 1 : Amélie-les-Bains (Eastern Pyrenees). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Inorganic mass spectrometry”. Adams F, Gijbels R, Van Grieken R Wiley, Chichester, page 404 p. (1988).
Keywords: ME3 Book as editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
van Grieken R, Gijbels R, Speecke A, Hoste J (1971) Determination of oxygen, silicon, phosphorus and copper in iron and steel by 14 MeV neutron activation analysis. S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Geothermal water analysis by X-ray fluorescence and neutron activation”. van Grieken R, Gijbels R, Blommaert W, Vandelannoote R, Van 't dack L US Energy Research and Development Administration, S.l., page 368 (1978).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Application of trace element analysis to geothermal waters”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 429 (1977)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“L'analyse des eaux géothermales par spectrométrie de masse à, étincelles”. Vandelannoote R, Blommaert W, van Grieken R, Gijbels R, Spectra 2000: la revue de l'instrumentation 53, 66 (1979)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of geothermal waters by spark source mass spectrometry”. Vandelannoote R, Blommaert W, Gijbels R, van Grieken R, Fresenius' Zeitschrift für analytische Chemie 309, 291 (1981). http://doi.org/10.1007/BF00488604
Abstract: Although the analysis of thermal water by spark-source mass spectrometry (SSMS) is rather timeconsuming, it allows the detection of about 20 elements of geochemical interest down to the ppb-level. A physical preconcentration is proposed in order to collect elements having quite different chemical properties, e.g. alkalis, transition elements, and elements occurring in anionic form. The relative sensitivity factors appear to be rather independent of the salt content of the graphite electrodes. Contrary to neutron activation analysis, SSMS has a quite uniform elemental sensitivity, and allows to determine elements for which neutron activation is not suitable, e.g. Sn and Pb. The precision of SSMS is however by a factor of about 2 worse than that obtained for neutron activation.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 8
DOI: 10.1007/BF00488604
|
|
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 65, 1 (1973). http://doi.org/10.1016/S0003-2670(01)80158-6
Abstract: A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 12
DOI: 10.1016/S0003-2670(01)80158-6
|
|
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 64, 187 (1973). http://doi.org/10.1016/S0003-2670(01)82436-3
Abstract: A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 11
DOI: 10.1016/S0003-2670(01)82436-3
|
|
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|
|
“Experimental weathering studies of igneous rocks (alkali-granite, granodiorite, gabbro and granite) and sedimentary gneiss under hydrothermal conditions”. Van 't dack L, Beusen J-M, Claesson T, Vandelannoote R, van Grieken R, Gijbels R, , 363 (1985)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Multi-element trace analysis of geothermal waters : problems, characteristics and applicability”. Vandelannoote R, Blommaert W, Van 't dack L, van Grieken R, Gijbels R, , 523 (1985)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace element geochemistry in thermal waters from Amélie-les-Bains (Eastern Pyrenees, France)”. Gijbels R, van Grieken R, Vandelannoote R, Blommaert W, Van 't dack L, , 123 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace element geochemistry in thermal waters from Plombières and Bains (Vosges)”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 396 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|