“Micro-Raman analysis for the identification of pigments from 19th and 20th century paintings”. Aibéo CL, Goffin S, Schalm O, van der Snickt G, Laquière N, Eyskens P, Janssens K, Journal of Raman spectroscopy 39, 1091 (2008). http://doi.org/10.1002/JRS.1990
Abstract: In this article, results using confocal µ-Raman to analyse the cross-section of paint samples are presented. Results obtained with light microscopy, scanning electron microscopy (SEM) combined with an energy dispersive X-ray analysis (EDX) and micro-X-ray fluorescence (µ-XRF) are mentioned and compared to the ones obtained with confocal (MRS). In some cases, pigment identification was possible only by combining analytical results from different techniques. The samples were drawn from five paintings belonging to the Academy of Fine Arts of Antwerp, which are part of a collection of 34 paintings made by students from the Academy between 1819 and 1920. Since, on the one hand, the painting techniques and materials, especially pigments, used in this period are still not completely known, and on the other hand, this collection constitutes a very important and reliable resource of information, these paintings were chosen for a systematic investigation. They represent the evolution of painting in Belgium over approximately a century.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.969
Times cited: 28
DOI: 10.1002/JRS.1990
|
“Micro and surface analysis in archaeology”. Adams F, Adriaens A, Aerts A, de Raedt I, Janssens K, Schalm O, Journal of analytical atomic spectrometry 12, 257 (1997). http://doi.org/10.1039/A606091I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A606091I
|
“Monitoring the impact of the indoor air quality on silver cultural heritage objects using passive and continuous corrosion rate assessments”. 't Hart L, Storme P, Anaf W, Nuyts G, Vanmeert F, Dorriné, W, Janssens K, De Wael K, Schalm O, Applied physics A : materials science &, processing 122, 923 (2016). http://doi.org/10.1007/S00339-016-0456-2
Abstract: There is a long tradition in evaluating industrial atmospheres by measuring the corrosion rate of exposed metal coupons. The heritage community also uses this method, but the interpretation of the corrosion rate often lacks clarity due to the low corrosivity in indoor museum environments. This investigation explores the possibilities and drawbacks of different silver corrosion rate assessments. The corrosion rate is determined by three approaches: (1) chemical characterization of metal coupons using analytical techniques such as electrochemical measurements, SEM-EDX, XRD, and µ-Raman spectroscopy, (2) continuous corrosion monitoring methods based on electrical resistivity loss of a corroding nm-sized metal wire and weight gain of a corroding silver coated quartz crystal, and (3) characterization of the visual degradation of the metal coupons. This study confirms that subtle differences in corrosivity between locations inside a museum can be determined on condition that the same corrosion rate assessment is used. However, the impact of the coupon orientation with respect to the prevailing direction of air circulation can be substantially larger than the impact of the coupon location.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 1.455
Times cited: 3
DOI: 10.1007/S00339-016-0456-2
|