|
“XRS activities at the Micro &, Trace Analysis Centre (MiTAC), University of Antwerp, Belgium”. Padilla R, Janssens K, van Espen P, Van Grieken R, IAEA XRF newsletter 12, 13 (2006)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Evaluation of energy-dispersive x-ray spectra of low-Z elements from electron-probe microanalysis of individual particles”. Osán J, de Hoog J, van Espen P, Szalóki I, Ro C-U, Van Grieken R, X-ray spectrometry 30, 419 (2001). http://doi.org/10.1002/XRS.523
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.523
|
|
|
“Study of quasi-fractal many-particle-systems and percolation networks by zero-loss spectroscopic imaging, electron energy-loss spectroscopy and digital image analysis”. Oleshko V, Kindratenko V, Gijbels R, van Espen P, Jacob W, Mikrochimica acta: supplementum 13, 443 (1996)
Abstract: Submicron colloidal Ag particles and nano-sized filaments forming a statistical percolation network during ''in situ'' development of double structure tabular microcrystals of AgRr(I) emulsions have been studied by electron energy-loss spectroscopy and zero-loss electron spectroscopic imaging (EELS/ZLESI). Image analysis has shown that random quasi-fractal clusters were formed in the colloid. ZLESI has been applied to characterise the morphology and defect structure of aggregated particles and filaments. Their energy-loss spectra revealed plasmon excitations and interband 4d electron transitions between 4-32 eV energy-loss. To study the cluster structure and its relation to the physical properties, fractal analysis including estimations of cluster fractal dimensions and of density autocorrelation functions has been performed. Mechanisms of fractal aggregation based on known models of diffusion limited aggregation, cluster-cluster aggregation and percolation are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
|
|
|
“Pixe analysis of aerosol samples collected over the atlantic-ocean from a sailboat”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester WJ, Nuclear instruments and methods 181, 399 (1981). http://doi.org/10.1016/0029-554X(81)90640-6
Abstract: Size-fractionated aerosol samples, collected over the Atlantic Ocean, were analyzed for up to 20 elements by PIXE. Using a sailboat as sampling platform, duplicate samples were taken for two-day periods by means of battery operated 6-stage cascade impactors, positioned about 8 m above the sea surface. In the PIXE analysis of the fine particle stages (stages 3 to 5) a 5 times smaller beam size was used than for stages 1 and 2. This led to significant improvement in the detection limits for the former stages. The results from the duplicate impactor samples were normally in good agreement, indicating that the combined uncertainty of sampling and PIXE analysis was of the order of 20%. The precision of the PIXE analysis alone was investigated by rebombarding some samples six months after the first analysis. The trends with time of the fine particle sulfur and the coarse particle iron concentrations are discussed in some detail.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0029-554X(81)90640-6
|
|
|
“Sulfur and heavy metals over the Atlantic Ocean : comparison with other marine data”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester JW, (1980)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Study of the main physical processes contributing to image formation in emission radiography using mathematical modeling”. Leyva Pernia D, Cabal Rodríguez AE, Schalm O, van Espen P, Piñera Hernández I, Abreu Alfonso Y, (2013)
Keywords: P3 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“Quantitative analysis of 16-17th century archaeological glass vessels using PLS regression of EPXMA and μ-XRF data”. Lemberge P, Deraedt I, Janssens K, van Espen P, Journal of chemometrics 14, 751 (2000). http://doi.org/10.1002/1099-128X(200009/12)14:5/6<751::AID-CEM622>3.0.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 1.884
DOI: 10.1002/1099-128X(200009/12)14:5/6<751::AID-CEM622>3.0.CO;2-D
|
|
|
“Determination of fluorine in uranium oxyfluoride particles as an indicator of particle age”. Kips R, Pidduck AJ, Houlton MR, Leenaers A, Mace JD, Marie O, Pointurier F, Stefaniak EA, Taylor PDP, van den Berghe S, van Espen P, Van Grieken R, Wellum R, Spectrochimica acta: part B : atomic spectroscopy 64, 199 (2009). http://doi.org/10.1016/J.SAB.2008.12.001
Abstract: As swipe samples from enrichment activities typically contain uranium particles with a detectable amount of fluorine, the question was raised whether the analysis of fluorine in particles could complement the information on the uranium isotope ratios. For this, uranium oxyfluoride particles were prepared from the controlled hydrolysis of uranium hexafluoride (UF6). The relative amount of fluorine was characterized by scanning electron microscopy combined with energy-dispersive X-ray spectrometry (SEM-EDX), as well as ion-microprobe secondary ion mass spectrometry (IM-SIMS). Of particular interest was the assessment of the reduction of the amount of fluorine over time, and after exposure to UV-light and high temperatures. Micro-Raman spectrometry (MRS) was applied to look for differences in molecular structure between these various sample types. Both SEM-EDX and IM-SIMS showed a general reduction of the fluorine-to-uranium ratio after 12 years of storage. The exposure to UV-light and high temperatures was found to have accelerated the loss of fluorine. A distinct peak at 865 cm− 1 Raman shift was detected for the majority of particles analyzed by MRS. For the particles that were heat-treated, the Raman spectra were similar to the spectrum of U3O8. Although often large variations were observed between particles from the same sample, the three particle measurement techniques (IM-SIMS, SEM-EDX and MRS) showed some consistent trends. They therefore appear promising in terms of the ability to place bounds on particle age, as well as shedding light on the complex processes involved in UO2F2 particle ageing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/J.SAB.2008.12.001
|
|
|
“Fractal dimensional classification of aerosol particles by computer-controlled scanning electron microscopy”. Kindratenko VV, van Espen PJM, Treiger BA, Van Grieken RE, Environmental science and technology 28, 2197 (1994). http://doi.org/10.1021/ES00061A031
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1021/ES00061A031
|
|
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
|
|
“Accurate evaluation of \mu-PIXE and \mu-XRF spectral data through iterative least squares fitting”. Janssens K, Vekemans B, Adams F, van Espen P, Mutsaers P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 –, 7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY 26-30, 1995, Abano Terme, Italy 109, 179 (1996). http://doi.org/10.1016/0168-583X(95)01211-7
Abstract: The integration of the nonlinear least squares X-ray spectrum evaluation progam AXIL. into a mu-PIXE and a mu-XRF setup is discussed. The use of the software when procesing data sets derived from biological and geological samples is described.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0168-583X(95)01211-7
|
|
|
“Increased accuracy in the automated interpretation of large epma data sets by the use of an expert system”. Janssens K, Vanborm W, van Espen P, Journal of research of the National Bureau of Standards (1934) 93, 260 (1988). http://doi.org/10.6028/JRES.093.037
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.6028/JRES.093.037
|
|
|
“Euroanalysis 14: the European Conference on Analytical Chemistry”. Janssens K, van Espen P, Van 't dack L, Analytical and bioanalytical chemistry 391, 1107 (2008). http://doi.org/10.1007/S00216-008-2114-9
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 3.431
DOI: 10.1007/S00216-008-2114-9
|
|
|
“A general-purpose interface between fortran and the low-level functions of the ibm-pc”. Janssens K, van Espen P, Trends in analytical chemistry 7, 128 (1988). http://doi.org/10.1016/0165-9936(88)87009-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0165-9936(88)87009-2
|
|
|
“Evaluation of energy-dispersive x-ray-spectra with the aid of expert systems”. Janssens K, van Espen P, Analytica chimica acta 191, 169 (1986). http://doi.org/10.1016/S0003-2670(00)86306-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86306-0
|
|
|
“Implementation of an expert system for the qualitative interpretation of x-ray-fluorescence spectra”. Janssens K, van Espen P, Analytica chimica acta 184, 117 (1986). http://doi.org/10.1016/S0003-2670(00)86475-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86475-2
|
|
|
“PC-MCA : a software package for the acquisition and processing of spectral data”. Janssens K, Nobels J, van Espen P, Chemometrics and intelligent laboratory systems 3, 335 (1988). http://doi.org/10.1016/0169-7439(88)80033-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80033-9
|
|
|
“The development process of an expert system for the automated interpretation of large epma data sets”. Janssens K, Dorrine W, van Espen P, Chemometrics and intelligent laboratory systems 4, 147 (1988). http://doi.org/10.1016/0169-7439(88)80086-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80086-8
|
|
|
“Quantitative surface analysis of silver halide microcrystals using scanning ion microprobe and scanning Auger microprobe”. Janssens G, Geuens I, de Keyzer R, van Espen P, Gijbels R, Hubin A, Terryn H, Vereecken J Wiley, Chichester, page 161 (1996).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
|
|
|
“Novel quantitative procedures for in-situ X-ray fluorescence analysis”. Injuk J, Janssens K, van Espen P, Van Grieken R, (2001)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Concentration profiles of metal contaminants in fluvial sediments of a rural-urban drainage basin in Tanzania”. Hellar-Kihampa H, Potgieter-Vermaak S, De Wael K, Lugwisha E, van Espen P, Van Grieken R, International journal of environmental analytical chemistry 94, 77 (2014). http://doi.org/10.1080/03067319.2013.791976
Abstract: This study investigated concentration profiles of trace, rare earth and platinum group metals in fluvial sediments from the Pangani river basin (43,650 km2), one of the largest river basins in Tanzania, to assess its environmental quality. Sediment samples were collected in two distinct seasons from 12 representative sites of diverse land-use practices and characterised by ICP-MS after optimised microwave digestion. Ecological risks were assessed by evaluation of pollution index and comparison with legislated sediment quality guidelines (SQG). The results revealed contamination by some trace metals (e.g. Pb, V, Cu, Cr, Ni, Cd, As, Co, Mn and Zn) in concentrations ranging from 0.7 to 2940 mg kg−1, and four rare earth elements (Y, Ce, Nd, Yb) in concentrations ranging from 0.9 (Yb) to 500 mg kg−1 dry weight (Ce), which significantly exceeded the estimated background values at some stations. Palladium was the only platinum group element that was detected in quantifiable concentrations (0.33.5 mg kg−1). Concentrations of some trace metals exceeded the SQGs at some localised areas. Principal component analysis and multivariate correlations indicated geochemical characteristics of the area as the major control of metal concentrations and spatial variability. Organic matter and clay contents also played a significant role in metal distributions. Assessment of land-use practices upstream of the sampling locations was used to trace potential anthropogenic sources of metal enrichments, where highest levels were found in areas close to urban centres and agricultural activities. The study provides baseline data for future monitoring programs, and highlights the need for more comprehensive analysis involving a wider spatio-temporal scale and ecotoxicological risk assessment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.208
Times cited: 5
DOI: 10.1080/03067319.2013.791976
|
|
|
“Automated particle analysis of populations of silver halide microcrystals by electron probe microanalysis under cryogenic conditions”. Gregory CL, Nullens HA, Gijbels RH, van Espen PJ, Geuens I, de Keyzer R, Analytical chemistry 70, 2551 (1998). http://doi.org/10.1021/ac9710644
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 12
DOI: 10.1021/ac9710644
|
|
|
Gijbels R, van Grieken R, Blommaert W, Van 't dack L, van Espen P, Nullens H, Saelens R (1983) Application of analytical methods for trace elements in geothermal waters : part 2 : Plombières, Bains-les-Bains, Bourbonne (Vosges). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“The primary energy dependence of backscattered electron images up to 100 keV”. Geuens I, Nys B, Naudts J, Gijbels R, Jacob W, van Espen P, Scanning microscopy 5, 339 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Times cited: 3
|
|
|
“Size-differentiated composition of aerosols in Khartoum, Sudan”. Eltayeb MAH, van Espen PJ, Cafmeyer J, Van Grieken RE, Maenhaut W, The science of the total environment 120, 281 (1992). http://doi.org/10.1016/0048-9697(92)90062-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0048-9697(92)90062-W
|
|
|
“Comparison of x-ray absorption and emission techniques for the investigation of paintings”. Cabal A, Schalm O, Eyskens P, Willems P, Harth A, van Espen P, X-ray spectrometry 44, 141 (2015). http://doi.org/10.1002/XRS.2591
Abstract: Four x-ray techniques: computed radiography, emission radiography, energy-resolved radiography and imaging x-ray fluorescence were compared using four mock-up panel paintings. The paintings have different stratigraphy and pigments and are representative for different historical periods. One of the paintings has a hidden underlying painting. The type of pigments used mainly influences the information obtained by both the emission and absorption measurements; high-Z white pigment and high-Z color pigments giving the best contrast. Each of the techniques revealed interesting aspects of the paintings, but none of them could reveal the hidden painting to a satisfactory level. Due to the statistical quality of the spectral data, x-ray fluorescence gives elemental images with high contrast. The radiographic images are better to reveal the internal structure. Imaging x-ray fluorescence and energy-resolved radiography measurements can be done simultaneously, and the combination has the highest potential for the study of complex multilayer paintings. Copyright (c) 2015 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1002/XRS.2591
|
|
|
“Study of the uniformity of aerosol filters by scanning MA-XRF”. Cabal A, Legrand S, Van den Bril B, Tote K, Janssens K, van Espen P, X-ray spectrometry
T2 –, 17th European Conference on X-Ray Spectrometry (EXRS), JUN 19-24, 2016, Univ Gothenburg, Univ Gothenburg, Gothenburg, SWEDEN 46, 461 (2017). http://doi.org/10.1002/XRS.2767
Abstract: Energy-dispersive X-ray fluorescence (XRF) is an attractive analytical method to determine the level of air pollution by heavy metals. The concentration of the filter in ng/cm(2) is obtained by direct comparison of the net characteristic line intensity of an element with that of a thin film standard. As the sampled area on the filter and the area of the standard are larger than the area analysed by the instrument, the distribution of the elements on the surface of both samples and standards have to be sufficiently uniform. If this is not the case, biased concentration estimates are obtained. Two scanning macro-XRF setups with a beam diameter of similar to 0.5 mm were used to investigate the distribution of elements in (1) commercially available (Micromatter) standards, (2) in-house quartz filter standards obtained with an aerosol generator and (3) particulatematter (PM10) collected on quartz filters by a Leckel SEQ 47/50 sampler. The uniformity of the Micromatter standards was better than 2%. At least some in-house standards showed a concave distribution with less material at the edges. The maximum bias introduced by this is less than 5%. Because of the limited sensitivity of scanning XRF compared with conventional XRF, the distribution of only a few common elements like Ca and Fe could be determined reliably in aerosol filters. The distribution of some heavy elements could only be measured in filters sampled in polluted regions. In general, the loading of particulate matter over the filters was uniform. Copyright (C) 2017 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 4
DOI: 10.1002/XRS.2767
|
|
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
|
|
“CAC-2010 : Twelfth international conference on chemometrics in analytical chemistry”. Buydens L, van Espen P, Rutan S, Analytica chimica acta 705, 1 (2011). http://doi.org/10.1016/J.ACA.2011.08.001
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ACA.2011.08.001
|
|
|
“Classification of coal mine dust particles through fuzzy clustering of their energy-dispersive electron microprobe X-ray spectra”. Bondarenko I, van Espen P, Treiger B, Van Grieken R, Adams F, Microbeam analysis 3, 33 (1994)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|