|
“The mechanical behavior during (de)lithiation of coated silicon nanoparticles as anode material for lithium-ion batteries studied by InSitu transmission electron microscopy”. Van Havenbergh K, Turner S, Marx N, Van Tendeloo G, Energy technology 4, 1005 (2016). http://doi.org/10.1002/ENTE.201600057
Abstract: One approach to cope with the continuous irreversible capacity loss in Si-based electrodes, attributed to lithiation-induced volume changes and the formation of a solid-electrolyte interface (SEI), is by coating silicon nanoparticles. A coating can improve the conductivity of the electrode, form a chemical shield against the electrolyte, or provide mechanical confinement to reduce the volume increase. The influence of such a coating on the mechanical behavior of silicon nanoparticles during Li insertion and Li extraction was investigated by insitu transmission electron microscopy. The type of coating was shown to influence the size of the unreacted core that remains after reaction of silicon with lithium. Furthermore, two mechanisms to relieve the stress generated during volume expansion are reported: the initiation of cracks and the formation of nanovoids. Both result in a full reaction of the silicon nanoparticles, whereas with the formation of cracks, additional surface area is created, on which an SEI can be formed.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.789
Times cited: 6
DOI: 10.1002/ENTE.201600057
|
|
|
“Solidelectrolyte interphase evolution of carbon-coated silicon nanoparticles for lithium-ion batteries monitored by transmission electron microscopy and impedance spectroscopy”. Van Havenbergh K, Turner S, Driesen K, Bridel J-S, Van Tendeloo G, Energy technology 3, 699 (2015). http://doi.org/10.1002/ente.201500034
Abstract: The main drawbacks of silicon as the most promising anode material for lithium-ion batteries (theoretical capacity=3572 mAh g−1) are lithiation-induced volume changes and the continuous formation of a solidelectrolyte interphase (SEI) upon cycling. A recent strategy is to focus on the influence of coatings and composite materials. To this end, the evolution of the SEI, as well as an applied carbon coating, on nanosilicon electrodes during the first electrochemical cycles is monitored. Two specific techniques are combined: Transmission Electron Microscopy (TEM) is used to study the surface evolution of the nanoparticles on a very local scale, whereas electrochemical impedance spectroscopy (EIS) provides information on the electrode level. A TEMEELS fingerprint signal of carbonate structures from the SEI is discovered, which can be used to differentiate between the SEI and a graphitic carbon matrix. Furthermore, the shielding effect of the carbon coating and the thickness evolution of the SEI are described.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.789
DOI: 10.1002/ente.201500034
|
|
|
“Molecular information in static SIMS for the speciation of inorganic compounds”. van Ham R, Adriaens A, van Vaeck L, Gijbels R, Adams F, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 161/163, 245 (2000). http://doi.org/10.1016/S0168-583X(99)00750-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.109
Times cited: 19
DOI: 10.1016/S0168-583X(99)00750-8
|
|
|
“Image analysis and in situ FTIR as complementary detection tools for photocatalytic soot oxidation”. Van Hal M, Verbruggen SW, Yang X-Y, Lenaerts S, Tytgat T, Chemical engineering journal 367, 269 (2019). http://doi.org/10.1016/J.CEJ.2019.02.154
Abstract: Air pollution, especially particulate matter (PM), is an increasingly urgent problem in urban environments, causing both short and long-term health problems, climate interference and aesthetical problems due to building fouling. Photocatalysis has been shown to be a possible solution to that end. In this work two complementary detection methods for photocatalytic soot oxidation are studied and their advantages and disadvantages are discussed. First, a colour-based digital image analysis method is drastically improved towards an accurate, detailed and straightforward detection tool, that enables simultaneous measurement of the degradation of different grades of soot fouling (for instance a shallow soot haze versus condensed soot deposits). In the next part, a second soot oxidation detection method is presented based on in situ FTIR spectroscopy. This method has the additional advantage of providing more insight into the photocatalytic soot degradation process by monitoring both gaseous and adsorbed intermediates as well as reaction products while the reactions are ongoing. As an illustration, the proposed detection strategies were applied on four different commercially available and synthesized photocatalytic materials. The digital image analysis showed that P25 (Evonik) is the fastest photocatalytic soot degrader of all studied materials for both a uniform soot haze as well as concentrated soot spots. Application of the in situ method showed that for all studied materials adsorbed formate-related surface species were formed and that commercially available ZnO nanopowder has the highest specificity towards complete mineralization into CO2. With this we aim to provide a set of complementary experimental tools for the convenient, reliable, realistic and standardised detection of photocatalytic soot degradation.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
Impact Factor: 6.216
Times cited: 1
DOI: 10.1016/J.CEJ.2019.02.154
|
|
|
“Photocatalytic soot degradation under UV and visible light”. Van Hal M, Lenaerts S, Verbruggen SW, Environmental Science and Pollution Research , 1 (2022). http://doi.org/10.1007/S11356-022-23804-0
Abstract: Particulate matter is one of the most persistent global air pollutants that is causing health problems, climate disturbance and building deterioration. A sustainable technique that is able to degrade soot using (sun)light is photocatalysis. Currently, research on photocatalytic soot oxidation focusses on large band gap TiO2-based photocatalysts and thus requires the use of UV light. It would prove useful if visible light, and thus a larger fraction of the (freely available) solar spectrum, could additionally be utilised to drive this process. In this work, a visible light-active photocatalyst, WO3, is benchmarked to TiO2 under both UV and visible light. At the same time, the versatility and drastic improvement of a recently introduced digital image-based soot degradation detection method are demonstrated. An additional step correcting for non-soot related catalyst colour changes is applied, resulting in accurate detection and quantification of soot degradation for all studied photocatalysts, even for materials such as WO3 that are inherently coloured. With this study, we aim to broaden the scope of photocatalytic soot oxidation technology to visible light-active photocatalyst. Along with this study, we provide a versatile soot degradation detection methodology based on digital image analysis that is made widely applicable.
Keywords: A1 Journal article; Engineering sciences. Technology
Impact Factor: 5.8
DOI: 10.1007/S11356-022-23804-0
|
|
|
“Gas phase photofuel cell consisting of WO₃- and TiO₂-photoanodes and an air-exposed cathode for simultaneous air purification and electricity generation”. Van Hal M, Campos R, Lenaerts S, De Wael K, Verbruggen SW, Applied Catalysis B-Environmental 292, 120204 (2021). http://doi.org/10.1016/J.APCATB.2021.120204
Abstract: Research has shown the potential of photofuel cells (PFCs) for waste water treatment, enabling the (partial) recovery of the energy released from the degraded compounds as electricity. Literature on PFCs targeting air pollution on the other hand is extremely scarce. In this work an autonomously operating air purification device targeting sustainable electricity generation is presented. Knowledge on gas phase operation of PFCs was gathered by combining photocatalytic and photoelectrochemical measurements, both for TiO2 and WO3-based photocatalysts. While TiO2-based photocatalysts performed better in direct photocatalytic experiments, they were outperformed by WO3-based photoanodes in all-gas-phase PFC operation. Not only do WO3-based photocatalysts generate the highest steady state photocurrent, they also achieved the highest fuel-to-electricity conversion (>65 %). The discrepancies between gas phase photocatalytic and photoelectrochemical processes highlight the difference in driving material properties. This study serves as a proof-of-concept towards development of an autonomous, low-cost and widely applicable waste gas-to-electricity PFC device.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Sustainable Energy, Air and Water Technology (DuEL)
Impact Factor: 9.446
DOI: 10.1016/J.APCATB.2021.120204
|
|
|
“Trace metal fractionation effects between sea water and aerosols from bubble bursting”. Van Grieken RE, Johansson TB, Winchester JW, Journal de recherches atmosphériques 8, 611 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Geophysical applicability of aerosol size distribution measurements using cascade impactors and proton-induced X-ray-emission”. Van Grieken RE, Johansson TB, Akselsson KR, Winchester JW, Nelson JW, Chapman KR, Atmospheric environment : an international journal 10, 571 (1976). http://doi.org/10.1016/0004-6981(76)90040-8
Abstract: Proton Induced X-ray Emission, (PIXE), is capable of high precision analysis for trace element components of aerosol particle size fractions sampled by cascade impactor. A statistical evaluation of data quality has been carried out in order to distinguish between analytical uncertainties in the PIXE procedure, errors caused by cascade impactor performance and by other factors in the sampling procedure, and geophysical causes of differences in composition and particle size distributions of the elements in aerosols. Replicate analyses and simultaneous samplings taken in north Florida and St. Louis have been used for the data evaluation. In addition to the analytical error the sampling procedure contributes an error of ~ 10% to be added quadratically. The resulting precision is sufficient to evaluate the data in geophysical terms. This is illustrated by means of sample sets taken simultaneously in an urban, forest and coastal environment of the same region.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(76)90040-8
|
|
|
“Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water”. Van Grieken RE, Bresseleers CM, Vanderborght BM, Analytical chemistry 49, 1326 (1977). http://doi.org/10.1021/AC50017A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50017A011
|
|
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
|
|
“X-ray spectrometry for preventive conservation of cultural heritage”. Van Grieken R, Worobiec A, Pramåna: a journal of physics 72, 191 (2011). http://doi.org/10.1007/S12043-011-0041-3
Abstract: Analytical chemistry does play a key role in the chemical characterization of the environment and it appears that X-ray spectrometry, in its many forms, is one of the most relevant analytical techniques in preventive conservation, as it is in cultural heritage research in general. X-ray spectrometry has indeed been the method of choice for the characterization of the inorganic composition of atmospheric aerosols, for a long time. We have, over the last decade, intensively used various forms of X-ray spectrometry, viz., mostly energy-dispersive X-ray fluorescence, e.g. with polarized high-energy beam excitation, and automated electron probe X-ray microanalysis, together with other techniques, to identify particle types and their sources in indoor environments, including museums, while gaseous indoor pollutants were assessed using passive diffusion samplers. In each case, both bulk aerosols and individual aerosol particles were studied. For microanalysis of single particles, we have investigated a dozen techniques, but for wide, real-life applications, automated electron probe X-ray microanalysis is the most rewarding. We have first studied atmospheric aerosols in and around the Correr Museum in Venice, many other museums in Austria, Japan and England, and in the caves with prehistoric rock paintings in Altamira, Spain. Very recently, measurements were done in the Metropolitan Museum of Art in New York and theWawel Castle in Cracow, in Italian and Polish mountain churches, in a number of museums in Belgium and the Netherlands, and in cathedrals with medieval stained glass windows. In the Correr museum, it appeared that the particles most threatening for the Bellini paintings were released by the deteriorating plaster renderings, and this could be avoided by simply improving the rendering on the museum walls. In the Wawel Castle, outdoor pollution particles, like fine soot from diesel traffic, entering via leaks in the windows and doors, and also street-deicing salts and coal burning pollution particles, brought in by visitors, mostly in winter, were found to be most worrisome. Urgent questions that are not solved at this moment pertain to the deposition processes from the atmosphere to the cultural heritage items, the critical surface interactions that take place on these items, and the establishment of suitable particle concentration standards.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S12043-011-0041-3
|
|
|
“Sample contamination from a commercial grinding unit”. Van Grieken R, Van de Velde R, Robberecht H, Analytica chimica acta 118, 137 (1980). http://doi.org/10.1016/S0003-2670(01)93724-9
Abstract: The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93724-9
|
|
|
“Soil analysis by thin-film energy-dispersive X-ray fluorescence”. Van Grieken R, Van 't dack L, Costa Dantas C, Da Silveira Dantas H, Analytica chimica acta 108, 93 (1979). http://doi.org/10.1016/S0003-2670(01)93044-2
Abstract: Energy-dispersive x-ray fluorescence is advantageous for trace analysis of soils present as thin films. A target thickness of about 2 mg cm-2 provides a compromise between optimal sensitivity and minimal absorption effect or optimal accuracy. Sample preparation involves only suspending the finely ground soil in water and drying this suspension on a thin mylar foil glued on a ring that fits into the x.r.f. spectrometer. The effective sample weight present in the exciting beam area is computed from the scatter peaks, a method that cancels out target heterogeneity problems. High accuracy is demonstrated for many elements in reference soil and rock materials; a precision around 5% and a detection limit around 10 ppm can be achieved. As an illustration, results for 16 trace elements and preliminary interpretation are given for a series of pedologically important soil samples from Brasil.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93044-2
|
|
|
“The determination of copper in iron and steel by 14-Mev neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 51, 151 (1970). http://doi.org/10.1016/S0003-2670(01)95703-4
Abstract: A fast (10 min) non-destructive determination of copper in. steel and cast iron by 14-MeV neutron activation analysis is described. The 0.511-MeV annihilation radiation of62Cu (T1/2=9.8 min), induced by the reaction63Cu(n,2n)62Cu, is counted by two opposing NaI(Tl) detectors operating in coincidence. An oxygen flux monitor is used to normalise the irradiations. For high phosphorus contents, two measurements are made and the 9-min activity contribution is calculated. As the iron content of the samples is known, the use of pure iron samples allows correction for53Fe activity from the reaction54Fe(n,2n)53Fe(T1/2= 8.9 min). When the phosphorus and silicon activities are low, the procedure of counting and computing can be greatly simplified. Nuclear interferences of most common alloying and impurity elements were investigated.The precision is 23% for steels containing above 1% Cu, andCa. 10% for 0.1%Cu.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95703-4
|
|
|
“On the precision of oxygen determinations in steel by 14-MeVv neutron activation”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 52, 275 (1970). http://doi.org/10.1016/S0003-2670(01)80957-0
Abstract: The precision of the 14-MeV neutron activation determination of oxygen in steel has been examined as a function of the oxygen content for a large number of steel and cast iron samples. The experimental and the statistically expected standard deviations have been compared. In the conditions used, 2.5 counts from 16N were registered for each p.p.m. of oxygen in the samples. The neutron flux was monitored by a simultaneously irradiated oxygen standard.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)80957-0
|
|
|
“Spectroscopy and ion chromatography to study the effects of air pollution on historical buildings”. Van Grieken R, Roekens E, Sweevers H, Vleugels G, Spectroscopy 10, 70 (1989)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Current trends in the literature on X-ray emission spectrometry”. Van Grieken R, Markowicz A, Veny P, X-ray spectrometry 20, 271 (1991). http://doi.org/10.1002/XRS.1300200605
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300200605
|
|
|
“Characterisation of individual aerosol particles for atmospheric and cultural heritage studies”. Van Grieken R, Gysels K, Hoornaert S, Joos P, Osán J, Szalóki I, Worobiec A, Water, air and soil pollution 123, 215 (2000). http://doi.org/10.1023/A:1005215304729
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1005215304729
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
|
|
“Cultural heritage and the environment”. Van Grieken R, Delalieux F, Gysels K, Pure and applied chemistry 70, 2327 (1998). http://doi.org/10.1351/PAC199870122327
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1351/PAC199870122327
|
|
|
“Nomenclature for radioanalytical chemistry (IUPAC Recommendations 1994)”. Van Grieken R, de Bruin M, Pure and applied chemistry 66, 2513 (1994). http://doi.org/10.1351/PAC199466122513
Abstract: Nearly 200 terms commonly used in radioanalytical chemistry are unambiguously defined. The list is partially based on an earlier IUPAC-glossary (Pure Appl. Chem. 54 (1982) 1533-1554), but some modifications have been made, terms related to nuclear physics and technology have not been reconsidered and numerous new entries from the realm of radiometric analysis, radioimmunoassay and related techniques have been included.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1351/PAC199466122513
|
|
|
“Micro-analysis of individual environmental particles”. Van Grieken R, Artaxo P, Bernard P, Leysen L, Otten P, Storms H, Van Put A, Wouters L, Xhoffer C, Chemia analityczna 35, 75 (1990)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Editorial : award for best X-Ray Spectrometry referee during 2011-2012”. Van Grieken R, X-ray spectrometry 42, 3 (2013). http://doi.org/10.1002/XRS.2428
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2428
|
|
|
“Editorial: Award for best XRS referee during 2007-2008”. Van Grieken R, X-ray spectrometry 37, 571 (2008). http://doi.org/10.1002/XRS.1107
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1107
|
|
|
“Editorial : introducing Dr Markowicz as X-Ray Spectrometry's new associate editor for Europe”. Van Grieken R, X-ray spectrometry 42, 175 (2013). http://doi.org/10.1002/XRS.2447
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2447
|
|
|
“New Chinese members of the Advisory Board of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 35, 205 (2006)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“New members of the editorial board of X-ray Spectrometry”. Van Grieken R, X-ray spectrometry 42, 1 (2013). http://doi.org/10.1002/XRS.2431
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2431
|
|
|
“Preconcentration methods for the analysis of water by X-ray spectrometric techniques”. Van Grieken R, Analytica chimica acta 143, 3 (1982). http://doi.org/10.1016/S0003-2670(01)95486-8
Abstract: All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95486-8
|
|
|
“Single Crystal and Pentatwinned Gold Nanorods Result in Chiral Nanocrystals with Reverse Handedness”. Van Gordon K, Ni B, Girod R, Mychinko M, Bevilacqua F, Bals S, Liz‐Marzán LM, Angewandte Chemie International Edition (2024). http://doi.org/10.1002/anie.202403116
Abstract: Handedness is an essential attribute of chiral nanocrystals, having a major influence on their properties. During chemical growth, the handedness of nanocrystals is usually tuned by selecting the corresponding enantiomer of chiral molecules involved in asymmetric growth, often known as chiral inducers. We report that, even using the same chiral inducer enantiomer, the handedness of chiral gold nanocrystals can be reversed by using Au nanorod seeds with either single crystalline or pentatwinned structure. This effect holds for chiral growth induced both by amino acids and by chiral micelles. Although it was challenging to discern the morphological handedness for<italic>L</italic>‐cystine‐directed particles, even using electron tomography, both cases showed circular dichroism bands of opposite sign, with nearly mirrored chiroptical signatures for chiral micelle‐directed growth, along with quasi‐helical wrinkles of inverted handedness. These results expand the chiral growth toolbox with an effect that might be exploited to yield a host of interesting morphologies with tunable optical properties.
Keywords: A1 Journal Article; Electron Microscopy for Materials Science (EMAT) ;
Impact Factor: 16.6
DOI: 10.1002/anie.202403116
|
|