|
“Relative sensitivity factors in glow discharge mass spectrometry: the role of charge transfer ionization”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 11, 841 (1996). http://doi.org/10.1039/ja9961100841
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.466
Times cited: 38
DOI: 10.1039/ja9961100841
|
|
|
“The role of fast argon ions and atoms in the ionization of argon in a direct current glow discharge: a mathematical simulation”. Bogaerts A, Gijbels R, Journal of applied physics 78, 6427 (1995). http://doi.org/10.1063/1.360526
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.183
Times cited: 60
DOI: 10.1063/1.360526
|
|
|
“Role of sputtered Cu atoms and ions in a direct current glow discharge: combined fluid and Monte Carlo model”. Bogaerts A, Gijbels R, Journal of applied physics 79, 1279 (1996). http://doi.org/10.1063/1.361023
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.183
Times cited: 81
DOI: 10.1063/1.361023
|
|
|
“Role of Ar2+ and Ar+2 ions in a direct current argon glow discharge: a numerical description”. Bogaerts A, Gijbels R, Journal of applied physics 86, 4124 (1999). http://doi.org/10.1063/1.371337
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 50
DOI: 10.1063/1.371337
|
|
|
“Similarities and differences between direct current and radio-frequency glow discharges: a mathematical simulation”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 1191 (2000). http://doi.org/10.1039/b000519n
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 25
DOI: 10.1039/b000519n
|
|
|
“Three-dimensional modeling of a direct current glow discharge in argon: is it better than one-dimensional modeling?”.Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 359, 331 (1997). http://doi.org/10.1007/s002160050582
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 9
DOI: 10.1007/s002160050582
|
|
|
“Two-dimensional model of a direct current glow discharge : description of the argon metastable atoms, sputtered atoms and ions”. Bogaerts A, Gijbels R, Analytical chemistry 68, 2676 (1996). http://doi.org/10.1021/ac951206z
Abstract: A two-dimensional model is presented that describes the behavior of argon metastable atoms, copper atoms, and copper ions in an argon direct. current glow discharge, in the standard cell of the VG9000 glow discharge mass spectrometer for analyzing flat samples. The model is combined with a previously developed model for the electrons, argon ions, and atoms in the same cell to obtain an overall picture of the glow discharge, The results of the present model comprise the number densities of the described plasma species, the relative contributions of different production and loss processes for the argon metastable atoms, the thermalization profile of the sputtered copper atoms, the relative importance of the different ionization mechanisms for the copper atoms, the ionization degree of copper, the copper ion-to-argon ion density ratio, and the relative roles of copper ions, argon ions, and atoms in the sputtering process. All these quantities are calculated for a range of voltages and pressures, Moreover, since the sticking coefficient of copper atoms on solid surfaces is not well-known in the literature, the influence of this parameter on the results is briefly discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 57
DOI: 10.1021/ac951206z
|
|
|
“Collisional-radiative model for the sputtered copper atoms and ions in a direct current argon glow discharge”. Bogaerts A, Gijbels R, Carman RJ, Spectrochimica acta: part B : atomic spectroscopy 53, 1679 (1998). http://doi.org/10.1016/S0584-8547(98)00201-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 71
DOI: 10.1016/S0584-8547(98)00201-8
|
|
|
“Fundamental studies on a planar-cathode direct current glow discharge: part 2: numerical modeling and comparison with laser scattering experiments”. Bogaerts A, Gijbels R, Gamez G, Hieftje GM, Spectrochimica acta: part B : atomic spectroscopy 59, 449 (2004). http://doi.org/10.1016/j.sab.2003.12.001
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 26
DOI: 10.1016/j.sab.2003.12.001
|
|
|
“Comparison between a radio-frequency and direct current glow discharge in argon by a hybrid Monte Carlo-fluid model for electrons, argon ions and fast argon atoms”. Bogaerts A, Gijbels R, Goedheer W, Spectrochimica acta: part B : atomic spectroscopy 54, 1335 (1999). http://doi.org/10.1016/S0584-8547(99)00080-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 11
DOI: 10.1016/S0584-8547(99)00080-4
|
|
|
“Hybrid modeling of a capacitively coupled radio frequency glow discharge in argon: combined Monte Carlo and fluid model”. Bogaerts A, Gijbels R, Goedheer W, Japanese journal of applied physics 38, 4404 (1999). http://doi.org/10.1143/JJAP.38.4404
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.384
Times cited: 45
DOI: 10.1143/JJAP.38.4404
|
|
|
“Hybrid Monte Carlo-fluid model of a direct current glow discharge”. Bogaerts A, Gijbels R, Goedheer W, Journal of applied physics 78, 2233 (1995). http://doi.org/10.1063/1.360139
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.183
Times cited: 117
DOI: 10.1063/1.360139
|
|
|
“Improved hybrid Monte Carlo-fluid model for the electrical characteristics in an analytical radiofrequency glow discharge in argon”. Bogaerts A, Gijbels R, Goedheer W, Journal of analytical atomic spectrometry 16, 750 (2001). http://doi.org/10.1039/b103768b
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 11
DOI: 10.1039/b103768b
|
|
|
“Two-dimensional model of a direct current glow discharge: description of the electrons, argon ions and fast argon atoms”. Bogaerts A, Gijbels R, Goedheer WJ, Analytical chemistry 68, 2296 (1996). http://doi.org/10.1021/ac9510651
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 70
DOI: 10.1021/ac9510651
|
|
|
“Investigation of laser output power saturation in the He-Cu+ IR hollow cathode discharge laser by experiments and numerical modeling”. Bogaerts A, Gijbels R, Grozeva M, Sabotinov N, Physica scripta T105, 90 (2003). http://doi.org/10.1238/Physica.Topical.105a00090
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.28
DOI: 10.1238/Physica.Topical.105a00090
|
|
|
“Modeling of a millisecond pulsed glow discharge: investigation of the afterpeak”. Bogaerts A, Gijbels R, Jackson GP, Journal of analytical atomic spectrometry 18, 533 (2003). http://doi.org/10.1039/b212606k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 42
DOI: 10.1039/b212606k
|
|
|
“Calculation of gas heating in direct current argon glow discharges”. Bogaerts A, Gijbels R, Serikov VV, Journal of applied physics 87, 8334 (2000). http://doi.org/10.1063/1.373545
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 63
DOI: 10.1063/1.373545
|
|
|
“Collisional-radiative model for an argon glow discharge”. Bogaerts A, Gijbels R, Vlcek J, Journal of applied physics 84, 121 (1998). http://doi.org/10.1063/1.368009
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 138
DOI: 10.1063/1.368009
|
|
|
“Modeling of glow discharge optical emission spectrometry: calculation of the argon atomic optical emission spectrum”. Bogaerts A, Gijbels R, Vlcek J, Spectrochimica acta: part B : atomic spectroscopy 53, 1517 (1998). http://doi.org/10.1016/S0584-8547(98)00139-6
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 44
DOI: 10.1016/S0584-8547(98)00139-6
|
|
|
“Axial non-uniformity of longitudinal hollow cathode discharges for laser applications: numerical modeling and comparison with experiments”. Bogaerts A, Grozeva M, Applied physics: B: photo-physics and laser chemistry 75, 731 (2002). http://doi.org/10.1007/s00340-002-1039-9
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.696
Times cited: 8
DOI: 10.1007/s00340-002-1039-9
|
|
|
“Effect of helium/argon gas ratio in a He-Ar-Cu+ IR hollow-cathode discharge laser : modeling study and comparison with experiments”. Bogaerts A, Grozeva M, Applied physics B : lasers and optics 76, 299 (2003). http://doi.org/10.1007/s00340-002-1093-3
Abstract: The He-Ar-Cu+ IR laser operates in a hollow-cathode discharge, typically in a mixture of helium with a few-% Ar. The population inversion of the Cu+ ion levels, responsible for laser action, is attributed to asymmetric charge transfer between He+ ions and sputtered Cu atoms. The Ar gas is added to promote sputtering of the Cu cathode. In this paper, a hybrid modeling network consisting of several different models for the various plasma species present in a He-Ar-Cu hollow-cathode discharge is applied to investigate the effect of Ar concentration in the gas mixture on the discharge behavior, and to find the optimum He/Ar gas ratio for laser operation. It is found that the densities of electrons, Ar+ ions, Ar-m* metastable atoms, sputtered Cu atoms and Cu+ ions increase upon the addition of more Ar gas, whereas the densities of He+ ions, He-2(+) ions and He-m* metastable atoms drop considerably. The product of the calculated Cu atom and He+ ion densities, which determines the production rate of the upper laser levels, and hence probably also the laser output power, is found to reach a maximum around 1-5% Ar addition. This calculation result is compared to experimental measurements, and reasonable agreement has been reached.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.696
Times cited: 6
DOI: 10.1007/s00340-002-1093-3
|
|
|
“Three-dimensional density profiles of the argon metastable atoms in a direct current glow discharge: experimental study and comparison with calculations”. Bogaerts A, Guenard RD, Smith BW, Winefordner JD, Harrison WW, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 52, 219 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 36
|
|
|
“Multi-level molecular modelling for plasma medicine”. Bogaerts A, Khosravian N, Van der Paal J, Verlackt CCW, Yusupov M, Kamaraj B, Neyts EC, Journal of physics: D: applied physics 49, 054002 (2016). http://doi.org/10.1088/0022-3727/49/5/054002
Abstract: Modelling at the molecular or atomic scale can be very useful for obtaining a better insight in plasma medicine. This paper gives an overview of different atomic/molecular scale modelling approaches that can be used to study the direct interaction of plasma species with biomolecules or the consequences of these interactions for the biomolecules on a somewhat longer time-scale. These approaches include density functional theory (DFT), density functional based tight binding (DFTB), classical reactive and non-reactive molecular dynamics (MD) and united-atom or coarse-grained MD, as well as hybrid quantum mechanics/molecular mechanics (QM/MM) methods. Specific examples will be given for three important types of biomolecules, present in human cells, i.e. proteins, DNA and phospholipids found in the cell membrane. The results show that each of these modelling approaches has its specific strengths and limitations, and is particularly useful for certain applications. A multi-level approach is therefore most suitable for obtaining a global picture of the plasma–biomolecule interactions.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 11
DOI: 10.1088/0022-3727/49/5/054002
|
|
|
“Multi-level molecular modelling for plasma medicine”. Bogaerts A, Khosravian N, Van der Paal J, Verlackt CCW, Yusupov M, Kamaraj B, Neyts EC, Journal Of Physics D-Applied Physics 49, 054002 (2016)
Keywords: A1 Journal article; Plasma, laser ablation and surface modeling – Antwerp (PLASMANT)
Impact Factor: 2.588
|
|
|
“Modeling of magnetron and glow discharges”. Bogaerts A, Kolev I, Le vide: science, technique et applications 57, 296 (2002)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Plasma-based conversion of CO2: current status and future challenges”. Bogaerts A, Kozak T, van Laer K, Snoeckx R, Faraday discussions 183, 217 (2015). http://doi.org/10.1039/c5fd00053j
Abstract: This paper discusses our recent results on plasma-based CO2 conversion, obtained by a combination of experiments and modeling, for a dielectric barrier discharge (DBD), a microwave plasma and a packed bed DBD reactor. The results illustrate that plasma technology is quite promising for CO2 conversion, but more research is needed to better understand the underlying mechanisms and to further improve the capabilities.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.588
Times cited: 89
DOI: 10.1039/c5fd00053j
|
|
|
“Influence of sticking coefficients on the behavior of sputtered atoms in an argon glow discharge: modeling and comparison with experiment”. Bogaerts A, Naylor J, Hatcher M, Jones WJ, Mason R, Journal of vacuum science and technology: A: vacuum surfaces and films 16, 2400 (1998). http://doi.org/10.1116/1.581359
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.374
Times cited: 12
DOI: 10.1116/1.581359
|
|
|
“Gas discharge plasmas and their applications”. Bogaerts A, Neyts E, Gijbels R, van der Mullen J, Spectrochimica acta: part B : atomic spectroscopy 57, 609 (2002). http://doi.org/10.1016/S0584-8547(01)00406-2
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 462
DOI: 10.1016/S0584-8547(01)00406-2
|
|
|
“Plasma Technology: An Emerging Technology for Energy Storage”. Bogaerts A, Neyts EC, ACS energy letters 3, 1013 (2018). http://doi.org/10.1021/acsenergylett.8b00184
Abstract: Plasma technology is gaining increasing interest for gas conversion applications, such as CO2 conversion into value-added chemicals or renewable fuels, and N2 fixation from the air, to be used for the production of small building blocks for, e.g., mineral fertilizers. Plasma is generated by electric power and can easily be switched on/off, making it, in principle, suitable for using intermittent renewable electricity. In this Perspective article, we explain why plasma might be promising for this application. We briefly present the most common types of plasma reactors with their characteristic features, illustrating why some plasma types exhibit better energy efficiency than others. We also highlight current research in the fields of CO2 conversion (including the combined conversion of CO2 with CH4, H2O, or H2) as well as N2 fixation (for NH3 or NOx synthesis). Finally, we discuss the major limitations and steps to be taken for further improvement.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 56
DOI: 10.1021/acsenergylett.8b00184
|
|
|
“Foundations of plasma catalysis for environmental applications”. Bogaerts A, Neyts EC, Guaitella O, Murphy AB, Plasma Sources Science &, Technology (2022). http://doi.org/10.1088/1361-6595/ac5f8e
Abstract: Plasma catalysis is gaining increasing interest for various applications, but the underlying mechanisms are still far from understood. Hence, more fundamental research is needed to understand these mechanisms. This can be obtained by both modelling and experiments. This foundations paper describes the fundamental insights in plasma catalysis, as well as efforts to gain more insights by modelling and experiments. Furthermore, it discusses the state-of-the-art of the major plasma catalysis applications, as well as successes and challenges of technology transfer of these applications.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.8
DOI: 10.1088/1361-6595/ac5f8e
|
|