“Voltammetric behaviour of drotaverine hydrochloride in surfactant media and its enhancement determination in Tween-20”. Jain R, Vikas, Rather JA, Colloids and surfaces: B : biointerfaces 82, 333 (2011). http://doi.org/10.1016/J.COLSURFB.2010.09.005
Abstract: Simple, sensitive and rapid adsorptive voltammetric behaviour of drotaverine hydrochloride onto the HMDE has been explored and validated in surfactant media by using cyclic, differential pulse and square-wave voltammetry. Addition of Tween-20 to the drotaverine hydrochloride containing electrolyte enhances the reduction current signal. The voltammograms of the drug with Tween-20 in phosphate buffers of pH 2.511.0 exhibit a single well defined reduction peak which may be due to the reduction of Cdouble bond; length as m-dashC group. The cyclic voltammetric studies indicated the reduction of drotaverine hydrochloride at the electrode surface through two electron irreversible step and diffusion-controlled. The peak current showed a linear dependence with the drug concentration over the range 0.87.2 μg mL−1. The calculated LOD and LOQ are 1.8 and 6.0 ng mL−1 by SWCAdSV and 8.1 and 27.2 ng mL−1 by DPCAdSV, respectively. The procedure was applied to the assay of the drug in tablet form with mean percentage recoveries of 100.2% with SWCAdSV and 99.7% with DPCAdSV. The validity of the proposed methods was further assessed by applying a standard addition technique.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFB.2010.09.005
|
“Voltammetric assay of anti-vertigo drug betahistine hydrochloride in sodium lauryl sulphate”. Jain R, Yadav RK, Rather JA, Colloids and surfaces: A: physicochemical and engineering aspects 366, 63 (2010). http://doi.org/10.1016/J.COLSURFA.2010.05.027
Abstract: Assay and electrochemical behaviour of betahistine hydrochloride in BrittonRobinsons (BR) buffer of pH range 2.512.0 at a glassy carbon electrode have been investigated. Addition of anionic surfactant (sodium lauryl sulphate) to the betahistine hydrochloride solution containing electrolyte enhanced the reduction current signal while neutral surfactant (Tween-20) and cationic surfactant cetyl trimethylammonium bromide (CTAB) showed an opposite effect. Voltammograms of betahistine hydrochloride exhibited a single wave. Based on reduction behaviour of betahistine hydrochloride, a direct square-wave voltammetric method has been developed for the assay of betahistine hydrochloride in pharmaceutical formulation. The proposed method has been validated as per ICH guideline. System and method precision in terms of RSD were 1.88% and 1.60% respectively, whereas the method accuracy was indicated by the recovery of 97.6101.9%. Reduction peak current was linear over the target concentration with correlation coefficient 0.998. The proposed method was successfully applied to the determination of betahistine hydrochloride in pharmaceutical formulation. The results were compared with those obtained by the reference high performance liquid chromatographic method. No significant differences were found between results of proposed and reference methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFA.2010.05.027
|
“Glow discharges in emission and mass spectrometry”. Jakubowski N, Bogaerts A, Hoffmann V Blackwell, Sheffield (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Applications of micro-analysis to individual environmental particles”. Jambers W, de Bock L, Van Grieken R, Fresenius' journal of analytical chemistry 355, 521 (1996). http://doi.org/10.1007/S0021663550521
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S0021663550521
|
“Recent advances in the analysis of individual environmental particles: a review”. Jambers W, de Bock L, Van Grieken R, The analyst 120, 681 (1995). http://doi.org/10.1039/AN9952000681
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/AN9952000681
|
“Single particle and inorganic characterization of rainwater collected above the North Sea”. Jambers W, Dekov V, Van Grieken R, The science of the total environment 256, 133 (2000). http://doi.org/10.1016/S0048-9697(00)00477-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0048-9697(00)00477-0
|
“Single particle characterisation of inorganic and organic North Sea suspension”. Jambers W, Dekov V, Van Grieken R, Marine chemistry 67, 17 (1999). http://doi.org/10.1016/S0304-4203(99)00046-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0304-4203(99)00046-8
|
“A message in the dust”. Jambers W, Van Grieken R, Analysis Europe , 25 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Present and future applications of beam techniques in environmental microanalysis”. Jambers W, Van Grieken R, Trends in analytical chemistry 15, 114 (1996). http://doi.org/10.1016/0165-9936(95)00098-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0165-9936(95)00098-4
|
“Single particle characterisation of inorganic North Sea suspensions”. Jambers W, Van Grieken R, (1996)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Single particle characterisation of inorganic suspension in Lake Baikal”. Jambers W, Van Grieken R, Environmental science and technology 31, 1525 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Environmental problems”. Jambers W, Van Grieken RE page 803 (1997).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Jannis D (2021) Novel detection schemes for transmission electron microscopy. iv, 208 p
Abstract: Electron microscopy is an excellent tool which provides resolution down to the atomic scale with up to pm precision in locating atoms. The characterization of materials in these length scales is of utmost importance to answer questions in biology, chemistry and material science. The successful implementation of aberration-corrected microscopes made atomic resolution imaging relatively easy, this could give the impression that the development of novel electron microscopy techniques would stagnate and only the application of these instruments as giant magnifying tools would continue. This is of course not true and a multitude of problems still exist in electron microscopy. Two of such issues are discussed below. One of the biggest problems in electron microscopy is the presence of beam damage which occurs due the fact that the highly energetic incoming electrons have sufficient kinetic energy to change the structure of the material. The amount of damage induced depends on the dose, hence minimizing this dose during an experiment is beneficial. This minimizing of the total dose comes at the expense of more noise due to the counting nature of the electrons. For this reason, the implementation of four dimensional scanning transmission electron microscopy (4D STEM) experiments has reduced the total dose needed per acquisition. However, the current cameras used to measure the diffraction patterns are still two orders of magnitude slower than to the conventional STEM methods. Improving the acquisition speed would make the 4D STEM technique more feasible and is of utmost importance for the beam sensitive materials since less dose is used during the acquisition. In TEM there is not only the possibility to perform imaging experiments but also spectroscopic measurements. There are two frequently used methods: electron energy-loss spectroscopy (EELS) and energy dispersive x-ray spectroscopy (EDX). EELS measures the energy-loss spectrum of the incoming electron which gives information on the available excitations in the material providing elemental sensitivity. In EDX, the characteristic x-rays, arising from the decay of an atom which is initially excited due to the incoming electrons, are detected providing similar elemental analysis. Both methods are able to provide comparable elemental information where in certain circumstances one outperforms the other. However, both methods have a detection limit of approximately 100-1000 ppm which is not sufficient for some materials. In this thesis, two novel techniques which can make significant progress for the two problems discussed above.
Keywords: Doctoral thesis; Electron microscopy for materials research (EMAT)
|
Jannis D, Mü,ller-Caspary K, Bé,ché, A, Oelsner A, Verbeeck J (2019) Spectrocopic coincidence experiment in transmission electron microscopy
Abstract: This dataset contains individual EEL and EDX events where for every event (electron or X-ray), their energy and time of arrival is stored. The experiment was performed in a transmission electron microscope (Tecnai Osiris) at 200 keV. The material investigated is an Al-Mg-Si-Cu alloy. The 'full_dataset.mat' contains the full dataset and the 'subset.mat' has the first five frames of the full dataset. The attached 'EELS-EDX.ipynb' is a jupyter notebook file. This file describes the data processing in order to observe the temporal correlation between the electrons and X-rays.
Keywords: Dataset; Electron microscopy for materials research (EMAT)
DOI: 10.5281/ZENODO.2563880
|
“Do gaseous pollutants and particulate matter endanger our world heritage? A study in the Museum Plantin-Moretus, Antwerp”. Janssen E, Kontozova-Deutsch V, Krupińska B, Moris H, Peckstadt A, van Bos M, Watteeuw L, Van Grieken R, (2010)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Associations between ambient, personal, and indoor exposure to fine particulate matter constituents in Dutch and Finnish panels of cardiovascular patients”. Janssen NAH, Lanki T, Hoek G, Vallius M, de Hartog JJ, Van Grieken R, Pekkanen J, Brunekreef B, Occupational and environmental medicine 62, 868 (2005). http://doi.org/10.1136/OEM.2004.016618
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1136/OEM.2004.016618
|
“Conserving African biosphere reserves : a workshop on the valuation of ecosystem services in Man and the Biosphere Reserves”. Janssens de Bisthoven L, Rochette A-J, Verheyen E, Akpona TJ-D, Verbist B, Vanderhaegen K, Naturinda Z, Van Passel S, Berihun D, Munishi L, Hugé, J, Oryx 53, 609 (2019). http://doi.org/10.1017/S003060531900070X
Keywords: A1 Journal article; Engineering Management (ENM); Evolutionary ecology group (EVECO)
Impact Factor: 2.191
DOI: 10.1017/S003060531900070X
|
“Quantitative surface analysis of silver halide microcrystals using scanning ion microprobe and scanning Auger microprobe”. Janssens G, Geuens I, de Keyzer R, van Espen P, Gijbels R, Hubin A, Terryn H, Vereecken J Wiley, Chichester, page 161 (1996).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
|
“Comparison with other microanalytical techniques”. Janssens K page 211 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Editorial”. Janssens K, (2003)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Methods 4: elemental analysis (AAS/AES/X-ray fluorescence)”. Janssens K (2003).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Special issue on Microscopic and ultratrace x-ray fluorescence analysis: 2”. Janssens K, Journal of trace and microprobe techniques 14, 461 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Special issue: Proceedings of the 15th International Congress on X-ray Optics and Microanalysis”. Janssens K, Journal of analytical atomic spectroscopy 14, 357 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“A survey of the recent use of x-ray beam methods for non-destructive investigations in the cultural heritage sector”. Janssens K page 265 (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“X-ray based methods of analysis”. Janssens K page 129 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“X-ray fluorescence analysis”. Janssens K (2003).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“EXRS2022 : the 2022 edition of the European X-ray Spectrometry conference, held in Bruges, Belgium”. Janssens K, X-ray spectrometry 52, 276 (2023). http://doi.org/10.1002/XRS.3386
Keywords: Editorial; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 1.2
DOI: 10.1002/XRS.3386
|
“Applications in art and archaeology”. Janssens K, Adams F page 290 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Microscopic X-ray fluorescence analysis at second and third generation synchrotron sources”. Janssens K, Adams F, Debye Institute synchrotron chronicle , 9 (1997)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Overview”. Janssens K, Adams F page 1 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|