|
“Weathering of treated and untreated limestones in atmospheric exposures”. Vleugels GJ, Van Grieken RE, Journal of preservation technology 23, 48 (1991)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of trace metals in rain water by differential-pulse stripping voltammetry”. Vos L, Komy G, Reggers G, Roekens E, Van Grieken R, Analytica chimica acta 184, 271 (1986). http://doi.org/10.1016/S0003-2670(00)86491-0
Abstract: Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86491-0
|
|
|
“Multi-element analysis of urine by energy-dispersive x-ray fluorescence spectrometry”. Vos L, Robberecht H, Van Dyck P, Van Grieken R, Analytica chimica acta 130, 167 (1981). http://doi.org/10.1016/S0003-2670(01)84161-1
Abstract: For multi-element analysis of human urine, 25-ml samples doped with yttrium as internal standard are evaporated gently and then ashed up to 460°C overnight. The residue is pelletized and analysed by energy-dispersive x-ray fluorescence. Acid addition to facilitate the digestion is not mandatory. Recoveries are nearly quantitative for traces of Fe, Ni, Cu, Zn and Sr, to a lesser extent for lead, but not for arsenic or selenium. The standard deviation per measurement is typically around 6%. The detection limits are such that some 10 elements can be determined simultaneously in normal urine, and possibly more in cases of importance to toxicology or industrial hygiene.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84161-1
|
|
|
“Influence of ion energy-distributions and matrix effects on spark source-mass spectrometric analysis”. Vos L, Van Grieken R, International journal of mass spectrometry and ion processes 51, 63 (1983). http://doi.org/10.1016/0020-7381(83)85029-3
Abstract: The energy distributions of ions produced in a spark source mass spectrometer were recorded for different trace element ions and for the total ion current. Both electrodes of pure doped graphite, and with 10% potassium salts added, were examined. The results show that the measured energy of an ion is mainly determined by the m/z ratio and that the energy of the total ion current depends on the sample composition. It was also clear that if the accelerating voltage is set to obtain maximum transmission of the total ion current, the fraction of the heavy elements that is discriminated at the β-slit depends on the matrix composition if the pass band of the instrument is narrow. These effects influence considerably the accuracy in the analysis of variable samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0020-7381(83)85029-3
|
|
|
“Influence of ion-source geometry in spark source-mass spectrometric analysis”. Vos L, Van Grieken R, International journal of mass spectrometry and ion processes 59, 221 (1984). http://doi.org/10.1016/0168-1176(84)85098-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-1176(84)85098-3
|
|
|
“Influence of spark generator parameters in the analysis of graphite-electrodes by spark source-mass spectrometry”. Vos L, Van Grieken R, International journal of mass spectrometry and ion processes 55, 233 (1984). http://doi.org/10.1016/0168-1176(84)87087-1
Abstract: Spark source mass spectrometric analyses of doped carbon samples were performed at different pulse lengths, pulse frequencies and breakdown voltages. The pulse length and pulse frequencies had no influence on the analysis. The relation between breakdown voltage, spark gap and sample matrix was determined. With increasing breakdown voltage, the abundance of the multiply charged ions was found to decrease, whereas the abundance of the cluster ions increased. The breakdown voltage was also found to affect the absolute and relative intensities of different elements in different manners. Interpretation of these results led to some new considerations on the phenomena in a spark discharge.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-1176(84)87087-1
|
|
|
“Matrix effects and analysis of biological material by spark source mass spectrometry”. Vos L, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 321, 32 (1985). http://doi.org/10.1007/BF00464483
Abstract: Spark-source mass spectrometric analyses of synthetic simulated biological samples were performed to determine the importance of matrix effects. A correlation between the variation of the relative sensitivity coefficients (RSC's) and the spark plasma composition, hence plasma temperature, was found. The determined RSC's were used in the analysis of four biological standard reference materials. An accuracy of 1013% and detection limits between 0.005 and 0.5 ppm were obtained during analysis under normal conditions.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00464483
|
|
|
“Preparation of conducting electrodes from biological samples for multi-element trace analysis by spark-source mass spectrometry or emission spectrometry”. Vos L, Van Grieken R, Analytica chimica acta 164, 83 (1984). http://doi.org/10.1016/S0003-2670(00)85619-6
Abstract: Four decomposition procedures frequently used for biological material (dry ashing, open wet digestion, wet digestion in a teflon bomb and low-temperature ashing) are optimized for the conversion of biological samples to conducting electrodes suitable for multi-element trace determinations by spark-source mass spectrometry or emission spectrometry. The optimized procedures are evaluated with respect to contamination, retention and preconcentration of the trace elements, homogeneity of the electrodes and precision of the final results. Both dry-ashing methods are prone to losses by volatilization; simple dry ashing suffers from contamination problems during electrode preparation. Wet digestion gives better precision; digestion with nitric/sulfuric acids in an open flask is the method of choice for most elements being simpler and giving lower blanks than the bomb method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85619-6
|
|
|
“Spark source mass spectrometry for trace analysis of diverse biological matrices”. Vos L, Van Grieken R page 303 (1983).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Individual particle analysis of sediments from the Gulf of Lions, suspensions from the Rhône river and dust of Saharan origin: preliminary results”. Wegrzynek D, Eisma D, Van Grieken R, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Individual particle analysis of Western Mediterranean sediment cores, Rhône suspended matter and Sahara aerosols: investigation of inputs to the sediments”. Wegrzynek D, Jambers W, Van Grieken R, Eisma D, Marine chemistry 57, 25 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Particle analysis of sediments from the Gulf of Lions, suspended matter from the Rhone river, and Sahara dust”. Wegrzynek D, Van Grieken R, Eisma D page 51 (1994).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace metals in the St-Louis aerosol”. Winchester JW, Meinert DL, Nelson JW, Johansson TB, Van Grieken RE, Orsini C, Kaufmann HC, Akselsson R page 385 (1975).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Characterization of aerosol-associated lead by DPASV and LAMMA”. Wonders JHAM, Houweling S, de Bont FAJ, van Leeuwen HP, Eeckhaoudt SM, Van Grieken R, International journal of environmental analytical chemistry 56, 193 (1994). http://doi.org/10.1080/03067319408034100
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319408034100
|
|
|
“Damage and molecular changes under a laser beam in SEM-EDX/MRS interface : a case study on iron-rich particles”. Worobiec A, Darchuk L, Brooker A, Potgieter H, Van Grieken R, Journal of Raman spectroscopy 42, 808 (2011). http://doi.org/10.1002/JRS.2789
Abstract: The control of damage to individual environmental particles by a laser beam during Raman spectroscopy carried out in ambient air is generally well understood. The nature and control of damage under vacuum conditions (e.g. in the scanning electron microscopy with energy X-ray detection combined with micro-Raman spectroscopyinterfaced SEM-EDX/MRS) are more complex and less well comprehended. The physical and chemical processes that affect the damage caused to small particles by lasers still remain somewhat unclear, but certainly the atmosphere (vacuum/air) and the beam intensity have very significant influences. Furthermore, it has been determined that some particles (e.g. haematite), although stable under an electron beam, are damaged by the laser beam, hampering their analysis. Additionally, when simultaneous analyses by SEM/EDX and MRS are considered, the correct choice of the collection surface plays a crucial role. As a result, the following collection substrates were tested to determine their influence on the laser beam damage process to the particle: silver and aluminium foils and silicon wafers. A test study was performed using artificial examples of haematite (Fe2O3) particles. Exposure of Fe2O3 particles in vacuum to 514- and 785-nm laser radiation often leads to their melting, transformation and evaporation. The dependence of the damage caused by the laser beam on the particle structure is reported here. Molecular and crystallographic changes have also been revealed. Formation of magnetite (as an effect of re-crystallisation) and Raman inactive structures was detected.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/JRS.2789
|
|
|
“Unconventional microanalysis for low-Z, volatile and organic aerosol compounds”. Worobiec A, de Hoog J, Osán J, Szalóki I, Joos P, Van Grieken R, Journal of aerosol science 31, 384 (2000)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Thermal stability of beam sensitive atmospheric aerosol particles in electron probe microanalysis at liquid nitrogen temperature”. Worobiec A, de Hoog J, Osán J, Szalóki I, Ro C-U, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 58, 479 (2003). http://doi.org/10.1016/S0584-8547(03)00013-2
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(03)00013-2
|
|
|
“Ruthenium staining as an alternative preparation method for automated EPMA of individual biogenic and organic particles”. Worobiec A, Kaplinski A, Van Grieken R, X-ray spectrometry 34, 245 (2005). http://doi.org/10.1002/XRS.807
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.807
|
|
|
“Interfaced SEM/EDX and micro-Raman spectrometry for characterisation of heterogeneous environmental particles: fundamental and practical challenges”. Worobiec A, Potgieter-Vermaak S, Brooker A, Darchuk L, Stefaniak E, Van Grieken R, Microchemical journal 94, 65 (2010). http://doi.org/10.1016/J.MICROC.2009.09.003
Abstract: The molecular character of atmospheric particulate matter is of prime importance when interpreting air pollution trends and its subsequent influence on environmental monitoring and preventative conservation. The known methods of estimating the molecular composition normally involve elemental analysis of particles (both as bulk and computer controlled analyses of single particles) with subsequent multivariate analyses to clusterise the elements in groups of elements that are closely related to each other. With this approach one can at best suggest associations. Evidently the application of molecular spectroscopy in addition to elemental concentration profiles would provide intimate information regarding the nature of the particles and consequently their fate. This paper gives an overview of research performed in our laboratory and describes the optimisation of experimental parameters to use scanning electron microscopy with energy-dispersive X-ray detection (SEM/EDX) or electron probe X-ray microanalysis (EPXMA) in parallel with micro-Raman Spectrometry (MRS) to investigate single environmental particles. The challenges associated with the two stand-alone techniques are revealed and consequently those posed with an interfaced approach are discussed. Preliminary results, of an initial investigation of the SEM/EDX interfaced with MRS to ultra-fine heterogeneous environmental particles, are given.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2009.09.003
|
|
|
“Behavior of semi-volatile particles under a laser and electron beam: influence on the quality of analytical results”. Worobiec A, Potgieter-Vermaak S, Darchuk L, Vishnyakov V, Potgieter H, Van Grieken R, AIP conference proceedings 1267, 523 (2010). http://doi.org/10.1063/1.3482653
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1063/1.3482653
|
|
|
“Air particulate emissions in developing countries : a case study in South Africa”. Worobiec A, Potgieter-Vermaak SS, Berghmans P, Winkler H, Burger R, Van Grieken R, Analytical letters 44, 1907 (2011). http://doi.org/10.1080/00032719.2010.539734
Abstract: Atmospheric aerosols were collected during the winter in Bethlehem, South Africa. The particulate mass concentrations, ambient carbon mass concentrations, and chemical composition of various particulate fractions showed that the area is highly polluted. The fine particle mass concentrations peaked at 1000 µg/m3 for PM2.5. Ambient carbon mass concentrations ranged from 20 to 40 µg/m3. Single particle analysis confirmed that the fine particle fraction was dominated by organic particles. The topographical conditions, causing a low inversion, together with the high amounts of emissions from biomass burning, result in unacceptable levels of air pollution and pose a considerable health threat to the population.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1080/00032719.2010.539734
|
|
|
“Transport and deposition of airborne pollutants in exhibition areas located in historical buildings: study in Wawel Castle Museum in Cracow, Poland”. Worobiec A, Samek J, Krata A, van Meel K, Krupińska B, Stefaniak EA, Karaszkiewicz P, Van Grieken R, Journal of cultural heritage 11, 354 (2010). http://doi.org/10.1016/J.CULHER.2009.11.009
Abstract: Historical buildings and castles that have been turned nowadays into museums, as an exhibition area for precious cultural heritage (CH) items, need more attention since they are CH objects by themselves. Moreover, the preservation techniques require often, significant interventions; however such changes are not always possible or are very limited. The aim of the present study was to investigate the influence of outdoor air pollution on the composition of particulate matter and gases inside the museum of Wawel Castle in Cracow, Poland. During this study a combination of micro and trace analysis techniques were applied, including energy dispersive X-ray fluorescence (EDXRF) and electron probe microanalysis (EPMA). An intensive transport of air pollutants coupled with accumulation of the particles inside the museum was noticed (considerably higher in winter than summer). A high content of carbon and organic matter agglomerated with inorganic particles was determined. Those particles are of special concern because of their adhesive properties and reactivity. It was also noted that the conditions inside the museum favour the reaction of the particles with gaseous pollutants. It was especially the case for nitrate particles.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.CULHER.2009.11.009
|
|
|
“A seasonal study of atmospheric conditions influenced by the intensive tourist flow in the Royal Museum of Wawel Castle in Cracow, Poland”. Worobiec A, Samek L, Karaszkiewicz P, Kontozova-Deutsch V, Stefaniak EA, van Meel K, Krata A, Bencs L, Van Grieken R, Microchemical journal 90, 99 (2008). http://doi.org/10.1016/J.MICROC.2008.04.005
Abstract: Increasingmass tourismcan generate importantmicroclimatic perturbations and also elevate indoor pollution by the transport of fine particulatematter. The purpose of this researchwas to study the indoor air conditions in the RoyalMuseum ofWawel Castle in Cracow, Poland, displaying amongst other valuable works of art also a unique collection of Flemish tapestries. The investigation involved in the determination of transport and deposition of particulate matter brought in by visitors. The microclimate inside the exhibition rooms was also monitored. Samples of suspended particulateswere collected inside and outside themuseuminwinterand summer2006.On days with intensive tourist visits the concentration of total suspended particulates was significantly higher (i.e., 130 µg/m3 inwinter and 49 µg/m3 in summer) than on those days without tourists (i.e., 73 µg/m3 and 22 µg/m3 in winter and summer, respectively). The concentrations of all investigated elementswere also considerably higher during the tourist flow. This was especially valid for soil dust associated elements (Si, K, Ca, Al, and Ti), with considerably higher levels in summer than winter. This could be linked with much more frequent tourist activity in the summer period. Also, the concentration of Clwasmuch higher inwinter than summer, due to the use of deicing salts on the roads and pavements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2008.04.005
|
|
|
“Study of the winter and summer changes of the air composition in the church of Szalowa, Poland, related to conservation”. Worobiec A, Samek L, Spolnik Z, Kontozova V, Stefaniak E, Van Grieken R, Microchimica acta 156, 253 (2006). http://doi.org/10.1007/S00604-006-0619-5
Abstract: The St. Michael Archangel's Church in Szalowa, Poland, was selected for closer investigation with respect to the indoor/outdoor air exchange and its influence on the air quality and work arts preservation. Chemical composition, size and abundance of particulate matter and concentration of gases NO2, SO2, O-3 inside and outside the church were determined. To study seasonal variation of the weather condition (temperature, inversion level, wind direction) and the influence of seasonal sources of the air pollution (like heating of the nearby houses), samples were collected in winter and summer time. It was stated that suspended particulate matter inside the wooden church has in general an outdoor source. Several groups of particles were distinguished such as the organic ones, soil dust, nitrates and sulphates. In case of organic and soil dust particles, the concentration inside was higher than outside. From the results, in comparison to literature data, one can conclude that accumulation of particulate suspended matter in the church is more intense than in other types of buildings. Gaseous pollutants were detected but their concentration was negligible.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S00604-006-0619-5
|
|
|
“Comprehensive microanalytical study of welding aerosols with x-ray and Raman based methods”. Worobiec A, Stefaniak EA, Kiro S, Oprya M, Bekshaev A, Spolnik Z, Potgieter-Vermaak SS, Ennan A, Van Grieken R, X-ray spectrometry 36, 328 (2007). http://doi.org/10.1002/XRS.979
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.979
|
|
|
“Characterisation of individual atmospheric particles within the Royal Museum of the Wawel Castle in Cracow, Poland”. Worobiec A, Stefaniak EA, Kontozova V, Samek L, Karaszkiewicz P, van Meel K, Van Grieken R, e-Preservation Science 3, 63 (2006)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Characterisation of concentrates of heavy mineral sands by micro-Raman spectrometry and CC-SEM/EDX with HCA”. Worobiec A, Stefaniak EA, Potgieter-Vermaak S, Sawlowicz Z, Spolnik Z, Van Grieken R, Applied geochemistry 22, 2078 (2007). http://doi.org/10.1016/J.APGEOCHEM.2007.05.003
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.APGEOCHEM.2007.05.003
|
|
|
“Characterisation of Amazon Basin aerosols at the individual particle level by X-ray microanalytical techniques”. Worobiec A, Szalóki I, Osán J, Maenhaut W, Stefaniak EA, Van Grieken R, Atmospheric environment : an international journal 41, 9217 (2007). http://doi.org/10.1016/J.ATMOSENV.2007.07.056
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.ATMOSENV.2007.07.056
|
|
|
“Historical changes in air pollution in the tri-border region of Poland, Czech Republic and Germany”. Worobiec A, Zwozdziak A, Sówka I, Zwozdziak J, Stefaniak EA, Buczyńska A, Krata A, van Meel K, Van Grieken R, Górka M, Jedrysek M-O, Environment protection engineering 34, 81 (2008)
Abstract: In this study, we show the trends in the concentration Of SO2 and particulate matter (PM) in two health resorts, located in the tri-border region of Poland, Germany and Czech Republic. We analyze the annual time series and the seasonal variability of PM concentration for the months of July and February over the period of 1996-2007. Additionally, in July 2006, we measured the mean 24-hour concentration of PM and the content of heavy metals (by EDXRF analysis). We prove that nowadays air pollution in this region has diminished to a large extent as compared to the 90s of the last century. In Cieplice, the local influence is still evident; while Czerniawa is exposed to a periodical advection of polluted air from regional sources.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis of individual Antarctic aerosol particles”. Wouters L, Artaxo P, Van Grieken R, International journal of environmental analytical chemistry 38, 427 (1990). http://doi.org/10.1080/03067319008026946
Abstract: Individual Antarctic aerosol particles in the 0.54 μm aerodynamic diameter range were analyzed using laser microprobe mass analysis (LAMMA). As they were sampled near the ocean, the great majority consists of seasalt, transformed to various degrees in the atmosphere. Major alterations include the association of an excess sulfate and methane sulfonate with these particles. Sulfate-rich particles containing little or no chloride were found mostly in the smallest size fraction (0.51 μm), where they account for some 5% of all particles: they are most likely highly transformed seasalt. Aluminosilicates, on the other hand, only appear among the coarser particles: they represent 2% of the particulates in the 24 μm range. The remainder of the aerosol consists of organic, Fe-rich, K-rich and Zn-rich particles. The latter groups have very low abundances: always less than 1% of the population of the impactor stage(s) onto which they were collected.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319008026946
|
|