“Analysis of geothermal waters by spark source mass spectrometry”. Vandelannoote R, Blommaert W, Gijbels R, van Grieken R, Fresenius' Zeitschrift für analytische Chemie 309, 291 (1981). http://doi.org/10.1007/BF00488604
Abstract: Although the analysis of thermal water by spark-source mass spectrometry (SSMS) is rather timeconsuming, it allows the detection of about 20 elements of geochemical interest down to the ppb-level. A physical preconcentration is proposed in order to collect elements having quite different chemical properties, e.g. alkalis, transition elements, and elements occurring in anionic form. The relative sensitivity factors appear to be rather independent of the salt content of the graphite electrodes. Contrary to neutron activation analysis, SSMS has a quite uniform elemental sensitivity, and allows to determine elements for which neutron activation is not suitable, e.g. Sn and Pb. The precision of SSMS is however by a factor of about 2 worse than that obtained for neutron activation.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 8
DOI: 10.1007/BF00488604
|
“Statistical grouping and controlling factors of dissolved trace elements in a surface water system”. Vandelannoote R, Blommaert W, Van 't dack L, Gijbels R, van Grieken R, Environmental technology letters 4, 363 (1983). http://doi.org/10.1080/09593338309384219
Abstract: Sensitive multi‐element analytical techniques were applied to determine 24 dissolved trace components in 25 different water samples from a 10 km2 zone in Brittany, France. Correspondence factor and multiple regression analyses showed that the elements considered are influenced mainly by the presence of: Fe‐Mn oxide accumulations, a local poly‐metallic sulfide mineralization, and non‐mineralized host rocks, agricultural activity and abundant organic material in local swamps. Via these numerical techniques the location of the poly‐metallic ore body can be derived from the data set.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 1
DOI: 10.1080/09593338309384219
|
“Multi-element trace analysis of geothermal waters : problems, characteristics and applicability”. Vandelannoote R, Blommaert W, Van 't dack L, van Grieken R, Gijbels R, , 523 (1985)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“L'analyse des eaux géothermales par spectrométrie de masse à, étincelles”. Vandelannoote R, Blommaert W, van Grieken R, Gijbels R, Spectra 2000: la revue de l'instrumentation 53, 66 (1979)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace element and micro-mineral composition of some selected anhydrite samples from the Saint Ghislain drill hole (Hainaut, Belgium)”. Vandelannoote R, Van 't dack L, Gijbels R, Bulletin van de Belgische Vereniging voor Geologie 95, 101 (1986)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Influence of the temperature on the morphology of silver behenate microcrystals”. Vanwelkenhuysen I, Gijbels R, Geuens I, , 326 (1998)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Analysis of thermal waters by ICP-MS”. Veldeman E, Van 't dack L, Gijbels R, Campbell M, Vanhaecke F, Vanhoe H, Vandecasteele C The Royal Society of Chemistry, Cambridge, page 25 (1991).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Sulfur species and associated trace elements in south-west Bulgarian thermal waters”. Veldeman E, Van 't dack L, Gijbels R, Pentcheva E, Applied geochemistry 6, 49 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.268
Times cited: 7
|
“Surface analysis of silver halide microcrystals by imaging time-of-flight SIMS (TOF-SIMS)”. Verlinden G, Gijbels R, Brox O, Benninghoven A, Geuens I, de Keyzer R, (1997)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Chemical microcharacterization of ultrathin iodide conversion layers and adsorbed thiocyanate surface layers on silver halide microcrystals with time-of-flight SIMS”. Verlinden G, Gijbels R, Geuens I, Microscopy and microanalysis 8, 216 (2002). http://doi.org/10.1017/S1431927602020159
Abstract: The technique of imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS) and dual beam depth,profiling has been used to study the composition of the surface of tabular silver halide microcrystals. Analysis of individual microcrystals with a size well below 1 mum from a given emulsion is possible. The method is successfully applied for the characterization of silver halide microcrystals with subpercent global iodide concentrations confined in surface layers with a thickness below 5 nm. The developed TOF-SIMS analytical procedure is explicitly demonstrated for the molecular imaging of adsorbed thiocyanate layers (SCN) at crystal surfaces of individual crystals and for the differentiation of iodide conversion layers synthesized with KI and with AgI micrates (nanocrystals with a size between 10 and 50 nm). It can be concluded that TOF-SIMS as a microanalytical, surface-sensitive technique has some unique properties over other analytical techniques for the study of complex structured surface layers of silver halide microcrystals. This offers valuable information to support the synthesis of future photographic emulsions.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.891
Times cited: 1
DOI: 10.1017/S1431927602020159
|
“Photographic materials”. Verlinden G, Gijbels R, Geuens I Surface Spectra IM, Chichester, page 727 (2001).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Quantitative secondary ion mass spectrometry depth profiling of surface layers of cubic silver halide microcrystals”. Verlinden G, Gijbels R, Geuens I, Journal of the American Society for Mass Spectrometry 10, 1016 (1999). http://doi.org/10.1016/S1044-0305(99)00064-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.786
Times cited: 4
DOI: 10.1016/S1044-0305(99)00064-1
|
“Quantitative SIMS analysis of surface layers of cubic silver halide microcrystals: comparison of different quantification methods”. Verlinden G, Gijbels R, Geuens I, , 995 (1998)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Imaging time-of-flight SIMS (TOF-SIMS) surface analysis of halide distributions in complex silver halide microcrystals”. Verlinden G, Gijbels R, Geuens I, Benninghoven A, , 871 (1998)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Chemical surface characterization of complex AgX microcrystals by imaging TOF-SIMS and dual beam depth profiling”. Verlinden G, Gijbels R, Geuens I, de Keyzer R, , 213 (2000)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Surface analysis of halide distributions in complex AgX microcrystals by imaging time-of-flight SIMS (TOF-SIMS)”. Verlinden G, Gijbels R, Geuens I, de Keyzer R, Journal of analytical atomic spectrometry 14, 429 (1999). http://doi.org/10.1039/a807276k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 10
DOI: 10.1039/a807276k
|
“Surface analysis of halide distributions in complex AgX microcrystals by imaging time-of-flight SIMS (TOF-SIMS)”. Verlinden G, Gijbels R, Geuens I, de Keyzer R Antwerp, page 528 (1998).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Three-dimensional chemical characterization of complex silver halide microcrystals by scanning ion microprobe mass analysis”. Verlinden G, Janssens G, Gijbels R, van Espen P, Geuens I, Analytical chemistry 69, 3773 (1997). http://doi.org/10.1021/ac970010r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 6
DOI: 10.1021/ac970010r
|
“Methods using low and medium laser irradiance: laser-induced thermal desorption and matrix-assisted methods”. Vertes A, Gijbels R Wiley, New York, page 127 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Restricted energy transfer in laser desorption of high molecular weight biomolecules”. Vertes A, Gijbels R, Scanning microscopy 5, 317 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 11
|
“Introduction”. Vertes A, Gijbels R, Adams F Wiley, New York, page 1 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
Vertes A, Gijbels R, Adams F (1993) Laser ionization mass analysis. Wiley, New York
Keywords: ME1 Book as editor or co-editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Hydrodynamic model of matrix-assisted laser desorption mass spectrometry”. Vertes A, Irinyi G, Gijbels R, Analytical chemistry 65, 2389 (1993). http://doi.org/10.1021/ac00065a036
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 100
DOI: 10.1021/ac00065a036
|
“Electron microscopy and mass-spectrometry study of In GaAsP/InP heterostructures (p-i-n diodes) grown by liquid phase epitaxy”. Volkov VV, Luyten W, van Landuyt J, Férauge C, Oksenoid KG, Gijbels R, Vasilev MG, Shelyakin AA, Lazarev VB, Physica status solidi: A: applied research 140, 73 (1993). http://doi.org/10.1002/pssa.2211400105
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 7
DOI: 10.1002/pssa.2211400105
|
“LPE growth and characterization of InGaAsP/InP heterostructures: IR-emitting diodes at 1.66 μm: application to the remote monitoring of methane gas”. Volkov VV, van Landuyt J, Marushkin K, Gijbels R, Férauge C, Vasilyev MG, Shelyakin AA, Sokolovsky AA, Sensors and actuators : A : physical 62, 624 (1997). http://doi.org/10.1016/S0924-4247(97)01377-0
Abstract: Highly effective IR light-emitting diodes operating at the wavelength 1.66 mu m and based on the buried heterostructure In0.88Ga0.12As0.26P0.74/ In0.72Ga0.28As0.62P0.38/In0.53Ga0.47As/InP have been grown by liquid-phase epitaxy (LPE) and characterized in detail by means of transmission electron microscopy (TEM), high-resolution electron microscopy (HREM),electron diffraction (ED), X-ray diffraction (XRD), secondary-ion mass spectrometry (SIMS) and electroluminescence measurements. The InGaAsP epilayers are found to be well lattice matched and of good structural quality. A tentative explanation is presented for the spinodal decomposition observed in InGaAsP alloys. A new type of selective CK, gas sensor has been developed and fabricated an the basis of the IR light-emitting diode mentioned above. Especially designed for the remote control of CH4 gas via fibre optics, an integrated optoelectronic readout scheme has been developed and tested, It is shown that the proposed type of sensor can be used for the quantitative remote control of CH4 gas concentration (0.2-100%) via a fibre glass line up to a distance of 2 x 1 km. (C) 1997 Elsevier Science S.A.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.499
Times cited: 3
DOI: 10.1016/S0924-4247(97)01377-0
|
“Characterization of LPE grown InGaAsP/InP heterostructures: IR-LED at 1.66 μm used for the remote monitoring of methane gas”. Volkov VV, van Landuyt J, Marushkin KM, Gijbels R, Férauge C, Vasilyev MG, Shelyakin AA, Sokolovsky AA, Journal of crystal growth 173, 285 (1997)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.751
Times cited: 4
|
“Microanalysis of individual silver halide microcrystals”. Wu S, van Daele A, Jacob W, Gijbels R, Verbeeck A, de Keyzer R, Scanning microscopy 7, 17 (1993)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 7
|
“Microanalysis of individual silver halide microcrystals”. Wu S, van Daele A, Jacob W, Gijbels R, Verbeeck A, de Keyzer R, , 1612 (1992)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Structural analysis of silver halide cubic microcrystals with epitaxial or conversion growths by STEM-EDX”. Wu S, van Daele A, Jacob W, Gijbels R, Verbeeck A, de Keyzer R, Mikrochimica acta: supplementum 12, 261 (1992)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Evolution of charged particle densities after laser-induced photodetachment in a strongly electronegative RF discharge”. Yan M, Bogaerts A, Gijbels R, IEEE transactions on plasma science 30, 132 (2002). http://doi.org/10.1109/TPS.2002.1003959
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
DOI: 10.1109/TPS.2002.1003959
|