“Validated portable device for the qualitative and quantitative electrochemical detection of MDMA ready for on-site use”. Van Echelpoel R, Parrilla M, Sleegers N, Thiruvottriyur Shanmugam S, van Nuijs ALN, Slosse A, Van Durme F, De Wael K, Microchemical journal 190, 108693 (2023). http://doi.org/10.1016/J.MICROC.2023.108693
Abstract: Identifying and quantifying 3,4-methylenedioxymethamphetamine (MDMA) on-site in suspected illicit drug samples, whether it be at recreational settings or manufacturing sites, is a major challenge for law enforcement agencies (LEAs). Various analytical techniques exist to fulfil this goal, e.g. colourimetry and portable spectroscopic techniques, each having its specific limitations (e.g. low accuracy, fluorescence, no quantification) and strengths (e.g. fast, easy to use). In this work, for the first time, an electrochemical MDMA sensor is presented to become a detection tool that can realistically be used on-site. More specifically, the use of a single buffer solution and an unmodified screen-printed electrode, along with the integration of a data analysis algorithm and mobile application permits the straightforward on-site identification and quantification of MDMA in suspicious samples. Multiple studies investigating different parameters, including pH, concentration, reproducibility, temperature and binary mixture analyses, were executed. To fully understand all the occurring redox processes, liquid chromatography coupled with high-resolution mass spectrometry analysis of partially electrolyzed MDMA samples was performed unravelling oxidation of the methylenedioxy group. Validation of the methodology was executed on 15 MDMA street samples analysed by gas chromatography coupled with mass spectrometry and compared with the performance of a commercial portable Raman and Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR) device. The novel methodology outperformed the spectroscopic techniques, correctly identifying all 15 street samples. Additionally, the electrochemical sensor predicted the purity of the tablets with a mean absolute error of 2.3%. Overall, this new, electrochemical detection strategy provides LEAs the rapid, low-cost, on-site detection and quantification of MDMA in suspicious samples, without requiring specialized training.
Keywords: A1 Journal article; Engineering sciences. Technology; Toxicological Centre; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.8
DOI: 10.1016/J.MICROC.2023.108693
|
“Assessing the stability of arsenic sulfide pigments and influence of the binding media on their degradation by means of spectroscopic and electrochemical techniques”. Vermeulen M, Janssens K, Sanyova J, Rahemi V, McGlinchey C, De Wael K, Microchemical journal 138, 82 (2018). http://doi.org/10.1016/J.MICROC.2018.01.004
Abstract: In this paper, we used the semiconducting and lightfastness properties of synthetic and mineral arsenic sulfide pigments to study their stability by means of electrochemical and microfadometric techniques. A combination of these techniques shows that in the early stage of the degradation process, amorphous arsenic sulfides are more stable than both crystalline forms, while upon longer exposure time, amorphous pigments will fade more than both mineral pigments, making it less suitable. While the stability study was carried out on unbound pigments, the influence of the organic binder on the relative degradation of the arsenic sulfide pigments was investigated through a multi-analytical approach on pigment/binder mock-up paint samples. For this purpose, the formation of arsenic trioxide was assessed by micro Fourier transform infrared (μ-FTIR) spectroscopy while the influence of the binder on the formation of sulfates was studied by means of synchrotron radiation X-ray near edge structure (μ-XANES). Both techniques elucidate a higher stability of all pigments in gum arabic while the use of egg yolk as binder leads to the most degradation, most likely due to its sulfur-rich composition. In the context of the degradation of arsenic sulfide pigments, other binders such as animal glue, egg white or linseed oil show an intermediate impact.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.034
Times cited: 4
DOI: 10.1016/J.MICROC.2018.01.004
|
“Interfaced SEM/EDX and micro-Raman spectrometry for characterisation of heterogeneous environmental particles: fundamental and practical challenges”. Worobiec A, Potgieter-Vermaak S, Brooker A, Darchuk L, Stefaniak E, Van Grieken R, Microchemical journal 94, 65 (2010). http://doi.org/10.1016/J.MICROC.2009.09.003
Abstract: The molecular character of atmospheric particulate matter is of prime importance when interpreting air pollution trends and its subsequent influence on environmental monitoring and preventative conservation. The known methods of estimating the molecular composition normally involve elemental analysis of particles (both as bulk and computer controlled analyses of single particles) with subsequent multivariate analyses to clusterise the elements in groups of elements that are closely related to each other. With this approach one can at best suggest associations. Evidently the application of molecular spectroscopy in addition to elemental concentration profiles would provide intimate information regarding the nature of the particles and consequently their fate. This paper gives an overview of research performed in our laboratory and describes the optimisation of experimental parameters to use scanning electron microscopy with energy-dispersive X-ray detection (SEM/EDX) or electron probe X-ray microanalysis (EPXMA) in parallel with micro-Raman Spectrometry (MRS) to investigate single environmental particles. The challenges associated with the two stand-alone techniques are revealed and consequently those posed with an interfaced approach are discussed. Preliminary results, of an initial investigation of the SEM/EDX interfaced with MRS to ultra-fine heterogeneous environmental particles, are given.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2009.09.003
|
“A seasonal study of atmospheric conditions influenced by the intensive tourist flow in the Royal Museum of Wawel Castle in Cracow, Poland”. Worobiec A, Samek L, Karaszkiewicz P, Kontozova-Deutsch V, Stefaniak EA, van Meel K, Krata A, Bencs L, Van Grieken R, Microchemical journal 90, 99 (2008). http://doi.org/10.1016/J.MICROC.2008.04.005
Abstract: Increasingmass tourismcan generate importantmicroclimatic perturbations and also elevate indoor pollution by the transport of fine particulatematter. The purpose of this researchwas to study the indoor air conditions in the RoyalMuseum ofWawel Castle in Cracow, Poland, displaying amongst other valuable works of art also a unique collection of Flemish tapestries. The investigation involved in the determination of transport and deposition of particulate matter brought in by visitors. The microclimate inside the exhibition rooms was also monitored. Samples of suspended particulateswere collected inside and outside themuseuminwinterand summer2006.On days with intensive tourist visits the concentration of total suspended particulates was significantly higher (i.e., 130 µg/m3 inwinter and 49 µg/m3 in summer) than on those days without tourists (i.e., 73 µg/m3 and 22 µg/m3 in winter and summer, respectively). The concentrations of all investigated elementswere also considerably higher during the tourist flow. This was especially valid for soil dust associated elements (Si, K, Ca, Al, and Ti), with considerably higher levels in summer than winter. This could be linked with much more frequent tourist activity in the summer period. Also, the concentration of Clwasmuch higher inwinter than summer, due to the use of deicing salts on the roads and pavements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2008.04.005
|