“Optimization of the ion chromatographic quantification of airborne fluoride, acetate and formate in the Metropolitan Museum of Art, New York”. Kontozova-Deutsch V, Deutsch F, Bencs L, Krata A, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 86, 372 (2011). http://doi.org/10.1016/J.TALANTA.2011.09.030
Abstract: Ion chromatographic (IC) methods have been compared in order to achieve an optimal separation of fluoride, acetate and formate under various elution conditions on two formerly introduced analytical columns (i and ii) and a novel one (iii): (i) an IonPac AS14 (250 mm × 4 mm I.D.), (ii) Allsep A-2 (150 mm × 4.6 mm I.D.), and (iii) an IC SI-50 4E (250 mm (length) × 4 mm (internal diameter – I.D.)). The IC conditions for the separation of the anions concerned were optimized on the IC SI-50 4E column. A near baseline separation of these anions was attained on the IonPac AS14, whereas the peaks of fluoride and acetate could not be resolved on the Allsep A-2. A baseline separation for the three anions was achieved on the IC SI-50 4E column, when applying an eluent mixture of 3.2 mmol/L Na2CO3 and 1.0 mmol/L NaHCO3 with a flow rate of 1.0 mL/min. The highest precision of 1.7, 3.0 and 2.8% and the best limits of detection (LODs) of 0.014, 0.22 and 0.17 mg/L for fluoride, acetate and formate, respectively, were obtained with the IC SI-50 4E column. Hence, this column was applied for the determination of the acetic and formic acid contents of air samples taken by means of passive gaseous sampling at the Metropolitan Museum of Art in New York, USA. Atmospheric concentrations of acetic and formic acid up to 1050 and 450 μg/m3, respectively, were found in non-aerated showcases of the museum. In galleries and outdoors, rather low levels of acetic and formic acid were detected with average concentrations of 50 and 10 μg/m3, respectively. The LOD data of acetate and formate on the IC SI-50 4E column correspond to around 0.5 μg/m3 for both acetic and formic acid in air samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 19
DOI: 10.1016/J.TALANTA.2011.09.030
|
“Efficient separation of acetate and formate by ion chromatography: application to air samples in a cultural heritage environment”. Kontozova-Deutsch V, Krata A, Deutsch F, Bencs L, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 75, 418 (2008). http://doi.org/10.1016/J.TALANTA.2007.11.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.11.025
|
“Single-run ion chromatographic separation of inorganic and low-molecular-mass organic anions under isocratic elution: application to environmental samples”. Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 79, 16 (2009). http://doi.org/10.1016/J.TALANTA.2009.02.044
Abstract: For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 ìm particle size), Allsep A-2 (7 ìm particle size), and IC SI-50 4E (5 ìm particle size). A complete baseline separation for all analyzed anions (i.e., F−, acetate, formate, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F−, Ac−, For−, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2009.02.044
|
“Elemental and ionic components of atmospheric aerosols and associated gaseous pollutants in and near Dar es Salaam, Tanzania”. Mmari AG, Potgieter-Vermaak SS, Bencs L, McCrindle RI, Van Grieken R, Atmospheric environment : an international journal 77, 51 (2013). http://doi.org/10.1016/J.ATMOSENV.2013.04.061
Abstract: Elemental and water-soluble ionic compounds (WSICs) of atmospheric aerosols (total suspended particulate TSP) and some gaseous pollutants (SO2, NO2 and O3) from a coastal, semi-urban and rural site in and near Dar es Salaam, Tanzania were investigated during dry and wet seasons of January 2005November 2007. Na+, Ca2+, SO42−, NO3− and Cl− made up the dominant fraction of WSICs during the dry season with average concentrations ranging from non-detectable (n.d.)5.4, 0.262.6, 0.7414.7, 0.41.5 and 1.13.4 μg m−3, respectively, while in the wet season, from n.d. up to 1.7, 1.2, 4.4, 2.1 and 3.0 μg m−3, respectively. The total air concentrations of the detected elements (Al, Si, S, Cl, K, Ca, Fe and Zn) showed seasonal and site-specific variation in the range of 7.526.6 with an average of 14.5 μg m−3. Most of the air concentrations of pollutants were observed to decrease with increasing distance from the coastal site, which is under urban and industrial pollutant emissions. Sulphur and nitrogen oxidation ratios during the dry season ranged from 0.08 to 0.91 and 0.013 to 0.049, respectively, while they were between 0.090.65 and 0.0020.095, respectively, in the wet season. These values indicate the photochemical oxidation of SO2 and a high extent of NO3−formation in the atmosphere. Neutralization ratios revealed the presence of acidic SO42− and NO3− aerosols. Principal component analysis identified sea spray, local combustion, vehicular traffic, biomass burning and re-suspended road dust as dominant sources of aerosols at the studied coastal and semi-urban sites. However, at the rural site, besides sea spray, crustal sources, soil dust re-suspension and long-range transport are the possible origins of suspended particulates.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2013.04.061
|
“Platinum group elements in the environment and their health risk”. Ravindra K, Bencs L, Van Grieken R, The science of the total environment 318, 1 (2004). http://doi.org/10.1016/S0048-9697(03)00372-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0048-9697(03)00372-3
|
“Concentration trends and sources of polycyclic aromatic hydrocarbons (PAHs) in Belgium”. Ravindra K, Bencs L, Wauters E, de Hoog J, Deutsch F, Roekens E, Bleux N, Berghmans P, Van Grieken R, IASTA bulletin 17, 98 (2005)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Seasonal and site-specific variation in vapour and aerosol phase PAHs over Flanders (Belgium) and their relation with anthropogenic activities”. Ravindra K, Bencs L, Wauters E, de Hoog J, Deutsch F, Roekens E, Bleux N, Berghmans P, Van Grieken R, Atmospheric environment : an international journal 40, 771 (2006). http://doi.org/10.1016/J.ATMOSENV.2005.10.011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2005.10.011
|
“Low-pressure gas chromatography-ion trap mass spectrometry for the fast determination of polycyclic aromatic hydrocarbons in air samples”. Ravindra K, Godoi AFL, Bencs L, Van Grieken R, Journal of chromatography: A: bibliography section 1114, 278 (2006). http://doi.org/10.1016/J.CHROMA.2006.03.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2006.03.025
|
“The impact of electric overhead radiant heating on the indoor environment of historic churches”. Samek L, de Maeyer-Worobiec A, Spolnik Z, Bencs L, Kontozova V, Bratasz Ł, Kozłowski R, Van Grieken R, Journal of cultural heritage 8, 361 (2007). http://doi.org/10.1016/J.CULHER.2007.03.006
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.CULHER.2007.03.006
|
“Application of EDXRF and thin window EPMA for the investigation of the influence of hot air heating on the generation and deposition of particulate matter”. Spolnik Z, Bencs L, Worobiec A, Kontozova V, Van Grieken R, Microchimica acta 149, 79 (2005). http://doi.org/10.1007/S00604-004-0299-Y
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S00604-004-0299-Y
|
“Influence of different types of heating systems on particulate air pollutant deposition: the case of churches situated in a cold climate”. Spolnik Z, Worobiec A, Samek L, Bencs L, Belikov K, Van Grieken R, Journal of cultural heritage 8, 7 (2007). http://doi.org/10.1016/J.CULHER.2006.09.003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.CULHER.2006.09.003
|
“Monitoring of NO2 in the ambient air with passive samplers before and after a road reconstruction event”. Stranger M, Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Worobiec A, Naveau I, Roekens E, Van Grieken R, Microchemical journal 90, 93 (2008). http://doi.org/10.1016/J.MICROC.2008.04.001
Abstract: Nitrogen dioxide (NO2) concentrations were used to evaluate the air quality before and after the infrastructural change of an important traffic artery in Mortsel, Antwerp (Belgium). During the reconstruction works two pairs of traffic lanes were reduced to one in each direction. Two sampling campaigns were conducted: the first one before the works in 2003 and the second one in 2005, after the road works were finished. Sampling was performed on a weekly base with the use of passive diffusion tubes on the streets, and also indoors in nearby houses. The samples were analyzed by ion chromatography, from which data the NO2 concentrations in air could be calculated. These results were compared with NO2 values from the air monitoring station 42R801 of the Flemish Environment Agency in Borgerhout, Antwerp. On the base of different NO2 concentrations, correlated well with the traffic density, sampling locations were classified into three groups as follows: 1) heavily polluted (heavy traffic); 2) moderately polluted (medium traffic); or 3) less polluted (low traffic density). Sampling sites located further from the road works, enclosed to the group less polluted, showedthe lowestNO2 concentrations. The highestNO2 levelwas found for the locations close to reconstructionworks, which belonged to the group heavily polluted. The contribution of NO2 was at the samelevel before and after the roadworks. During the first campaign it ranged from30±7 µg/m3 to 71±11 µg/m3 and during the second sampling itwas between 36±17 µg/m3 and 73±17 µg/m3. These modernizationworks had no impact on preventing the traffic-related pollutant as NO2 and as a consequence no significant effect on the air quality in the studied region. It has been proven that the impact of traffic on the air quality is unmistakably high and simply reduction of the number of the traffic lanes, intended to discourage the traffic flow, had apparently no environmentally advantageous effect
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2008.04.001
|
Swerling G, Travaglini B, Van Grieken R, Spolnik Z, Bencs L, [et al.], European Project Freindly-Heating (2006) Il riscaldamento nelle chiese e la conservazione dei beni culturali = Church heating and the preservation of the cultural heritage. 240 p
Keywords: ME2 Book as editor or co-editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Some studies of the effect of indoor and outdoor pollutants on cultural heritage items”. Van Grieken R, Kontozova V, Godoi RHM, Spolnik Z, Worobiec A, Deutsch F, Bencs L, (2005)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Elemental concentrations in aerosols at the Belgian coast versus seasons and air mass trajectories”. van Meel K, Horemans B, Krata A, Bencs L, Buczyńska AJ, Dirtu AC, Worobiec A, Van Grieken R, Environmental chemistry letters 8, 157 (2010). http://doi.org/10.1007/S10311-009-0203-4
Abstract: Marine aerosols have extensively been monitored in the framework of a research project to investigate the inorganic and organic nutrient fluxes of the atmospheric nitrogen input into the North Sea. As a part of this project bulk analysis was also performed by energy dispersive X-ray fluorescence (EDXRF) on a total of 366 samples in order to provide detailed elemental composition. Samples have been clustered per campaign and differences were related to backward trajectories. Elements as Cl, Si, and S appeared to be the best tracers for coastal aerosols. Therefore they have been chosen to represent each campaign and to map the seasonal variations. It is clear that Cl is an excellent tracer for oceanic trajectories, while a less clear correlation between the soil dust components and the air mass trajectories is found.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP); Toxicological Centre
DOI: 10.1007/S10311-009-0203-4
|
“A seasonal study of atmospheric conditions influenced by the intensive tourist flow in the Royal Museum of Wawel Castle in Cracow, Poland”. Worobiec A, Samek L, Karaszkiewicz P, Kontozova-Deutsch V, Stefaniak EA, van Meel K, Krata A, Bencs L, Van Grieken R, Microchemical journal 90, 99 (2008). http://doi.org/10.1016/J.MICROC.2008.04.005
Abstract: Increasingmass tourismcan generate importantmicroclimatic perturbations and also elevate indoor pollution by the transport of fine particulatematter. The purpose of this researchwas to study the indoor air conditions in the RoyalMuseum ofWawel Castle in Cracow, Poland, displaying amongst other valuable works of art also a unique collection of Flemish tapestries. The investigation involved in the determination of transport and deposition of particulate matter brought in by visitors. The microclimate inside the exhibition rooms was also monitored. Samples of suspended particulateswere collected inside and outside themuseuminwinterand summer2006.On days with intensive tourist visits the concentration of total suspended particulates was significantly higher (i.e., 130 µg/m3 inwinter and 49 µg/m3 in summer) than on those days without tourists (i.e., 73 µg/m3 and 22 µg/m3 in winter and summer, respectively). The concentrations of all investigated elementswere also considerably higher during the tourist flow. This was especially valid for soil dust associated elements (Si, K, Ca, Al, and Ti), with considerably higher levels in summer than winter. This could be linked with much more frequent tourist activity in the summer period. Also, the concentration of Clwasmuch higher inwinter than summer, due to the use of deicing salts on the roads and pavements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2008.04.005
|