“Spatially resolved (semi)quantitative determination of iron (Fe) in plants by means of synchrotron micro X-ray fluorescence”. Terzano R, Alfeld M, Janssens K, Vekemans B, Schoonjans T, Vincze L, Tomasi N, Pinton R, Cesco S, Analytical and bioanalytical chemistry 405, 3341 (2013). http://doi.org/10.1007/S00216-013-6768-6
Abstract: Iron (Fe) is an essential element for plant growth and development; hence determining Fe distribution and concentration inside plant organs at the microscopic level is of great relevance to better understand its metabolism and bioavailability through the food chain. Among the available microanalytical techniques, synchrotron mu-XRF methods can provide a powerful and versatile array of analytical tools to study Fe distribution within plant samples. In the last years, the implementation of new algorithms and detection technologies has opened the way to more accurate (semi)quantitative analyses of complex matrices like plant materials. In this paper, for the first time the distribution of Fe within tomato roots has been imaged and quantified by means of confocal mu-XRF and exploiting a recently developed fundamental parameter-based algorithm. With this approach, Fe concentrations ranging from few hundreds of ppb to several hundreds of ppm can be determined at the microscopic level without cutting sections. Furthermore, Fe (semi)quantitative distribution maps were obtained for the first time by using two opposing detectors to collect simultaneously the XRF radiation emerging from both sides of an intact cucumber leaf.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 27
DOI: 10.1007/S00216-013-6768-6
|
“Micro-heterogeneity study of trace elements in USGS, MPI-DING and glass reference materials by means of synchrotron micro-XRF”. Kempenaers L, Janssens K, Jochum KP, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Adams F, Journal of analytical atomic spectrometry 18, 350 (2003). http://doi.org/10.1039/B212196D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 38
DOI: 10.1039/B212196D
|
“Suitability of polycapillary optics for focusing of monochromatic synchrotron radiation as used in trace level micro-XANES measurements”. Vincze L, Wei F, Proost K, Vekemans B, Janssens K, He Y, Yan Y, Falkenberg G, Journal of analytical atomic spectrometry 17, 177 (2002). http://doi.org/10.1039/B110210A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/B110210A
|
“Trace analysis allows to distinguish between Venetian and facon-de-Venise glass vessels of the 16th and 17th century”. de Raedt I, Janssens K, Veeckman J, Vincze L, Vekemans B, Jeffries T, Journal of analytical atomic spectrometry 16, 1012 (2001). http://doi.org/10.1039/B102597J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 49
DOI: 10.1039/B102597J
|
“The use of LA-ICP-MS for the characterization of the micro-heterogeneity of heavy metals in BCR CRM 680”. Kempenaers L, Bings NH, Jeffries TE, Vekemans B, Janssens K, Journal of analytical atomic spectrometry 16, 1006 (2001). http://doi.org/10.1039/B102512K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/B102512K
|
“Modeling of photon scattering at high X-ray energies : experiment versus simulation”. Vincze L, Vekemans B, Janssens K, Adams F, Journal of analytical atomic spectrometry
T2 –, 15th International Congress on X-Ray Optics and Microanalysis (ICXOM), AUG 24-27, 1998, ANTWERP, BELGIUM 14, 529 (1999). http://doi.org/10.1039/A808040B
Abstract: The use of a detailed Monte Carlo simulation code for X-ray fluorescence spectrometers is demonstrated for calculating the outcome of X-ray scattering experiments in the incident energy range 40-80 keV. The code was validated by comparisons of experimental and simulated spectral distributions in the case of thick, homogeneous samples in which multiple photon scattering occurs with high probability. The experimental spectral distributions were collected at beamline BW5 of HASYLAB, Germany, where a highly energetic, monochromatic synchrotron beam is available. With respect to heterogeneous samples, the code was employed to evaluate the use of Rayleigh and Compton scatter signals for obtaining three dimensional information on the sample dark matrix composition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A808040B
|
“The use of lead-glass capillaries for microfocusing of highly energetic (0-60 KeV) synchrotron radiation”. Janssens K, Vincze L, Vekemans B, Adams F, Haller M, Knöchel A, Journal of analytical atomic spectrometry 13, 339 (1998). http://doi.org/10.1039/A707700I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707700I
|
“Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies”. de Nolf W, Jaroszewicz J, Terzano R, Lind OC, Salbu B, Vekemans B, Janssens K, Falkenberg G, Spectrochimica acta: part B : atomic spectroscopy 64, 775 (2009). http://doi.org/10.1016/J.SAB.2009.06.003
Abstract: The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.30.5° are obtained at the bending magnet source when a pink beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.10.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2009.06.003
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 1: theory”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 75 (2000). http://doi.org/10.1016/S0584-8547(99)00172-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00172-X
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 2: application”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 1039 (2000). http://doi.org/10.1016/S0584-8547(00)00220-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00220-2
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
“Zinc distribution and speciation within rocket plants (Eruca vesicaria L. Cavalieri) grown on a polluted soil amended with compost as determined by XRF microtomography and Micro-Xanes”. Terzano R, al Chami Z, Vekemans B, Janssens K, Miano T, Ruggiero P, Journal of agricultural and food chemistry 56, 3222 (2008). http://doi.org/10.1021/JF073304E
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.154
Times cited: 68
DOI: 10.1021/JF073304E
|
“Spectroscopic investigation on the chemical forms of Cu during the synthesis of zeolite X at low temperature”. Terzano R, Spagnuolo M, Medici L, Tateo F, Vekemans B, Janssens K, Ruggiero P, Applied geochemistry 21, 993 (2006). http://doi.org/10.1016/J.APGEOCHEM.2006.03.004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.581
Times cited: 15
DOI: 10.1016/J.APGEOCHEM.2006.03.004
|
“PXRF, \mu-XRF, vacuum \mu-XRF, and EPMA analysis of Email Champlevé, objects present in Belgian museums”. van der Linden V, Meesdom E, Devos A, van Dooren R, Nieuwdorp H, Janssen E, Balace S, Vekemans B, Vincze L, Janssens K, Microscopy and microanalysis 17, 674 (2011). http://doi.org/10.1017/S1431927611011950
Abstract: The enamel of 20 Email Champlevé objects dating between the 12th and 19th centuries was investigated by means of microscopic and portable X-ray fluorescence analysis (μ-XRF and PXRF). Seven of these objects were microsampled and the fragments were analyzed with electron probe microanalysis (EPMA) and vacuum μ-XRF to obtain quantitative data about the composition of the glass used to produce these enameled objects. As a result of the evolution of the raw materials employed to produce the base glass, three different compositional groups could be discriminated. The first group consisted of soda-lime-silica glass with a sodium source of mineral origin (with low K content) that was opacified by addition of calcium antimonate crystals. This type of glass was only used in objects made in the 12th century. Email Champlevé objects from the beginning of the 13th century onward were enameled with soda-lime-silica glass with a sodium source of vegetal origin. This type of glass, which has a higher potassium content, was opacified with SnO2 crystals. The glass used for 19th century Email Champlevé artifacts was produced with synthetic and purified components resulting in a different chemical composition compared to the other groups. Although the four analytical techniques employed in this study have their own specific characteristics, they were all found to be suitable for classifying the objects into the different chronological categories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.891
Times cited: 9
DOI: 10.1017/S1431927611011950
|
“μ-XRF/μ-RS vs. SR μ-XRD for pigment identification in illuminated manuscripts”. van der Snickt G, de Nolf W, Vekemans B, Janssens K, Applied physics A : materials science &, processing 92, 59 (2008). http://doi.org/10.1007/S00339-008-4447-9
Abstract: For the non-destructive identification of pigments and colorants in works of art, in archaeological and in forensic materials, a wide range of analytical techniques can be used. Bearing in mind that every method holds particular limitations, two complementary spectroscopic techniques, namely confocal ì-Raman spectroscopy (ì-RS) and ì-X-ray fluorescence spectroscopy (ì-XRF), were joined in one instrument. The combined ì-XRF and ì-RS device, called PRAXIS unites both complementary techniques in one mobile setup, which allows ì- and in situ analysis. ì-XRF allows one to collect elemental and spatially-resolved information in a non-destructive way on major and minor constituents of a variety of materials. However, the main disadvantages of ì-XRF are the penetration depth of the X-rays and the fact that only elements and not specific molecular combinations of elements can be detected. As a result ì-XRF is often not specific enough to identify the pigments within complex mixtures. Confocal Raman microscopy (ì-RS) can offer a surplus as molecular information can be obtained from single pigment grains. However, in some cases the presence of a strong fluorescence background limits the applicability. In this paper, the concrete analytical possibilities of the combined PRAXIS device are evaluated by comparing the results on an illuminated sheet of parchment with the analytical information supplied by synchrotron radiation ì-X-ray diffraction (SR ì-XRD), a highly specific technique.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.455
Times cited: 56
DOI: 10.1007/S00339-008-4447-9
|
“ID18F: a new micro-X-ray fluorescence end-station at the European Synchrotron Radiation Facility (ESRF): preliminary results”. Somogyi A, Drakopoulos M, Vincze L, Vekemans B, Camerani C, Janssens K, Snigirev A, Adams F, X-ray spectrometry 30, 242 (2001). http://doi.org/10.1002/XRS.494.ABS
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 76
DOI: 10.1002/XRS.494.ABS
|
“Use of microscopic XRF for non-destructive analysis in art an archaeometry”. Janssens K, Vittiglio G, Deraedt I, Aerts A, Vekemans B, Vincze L, Wei F, de Ryck I, Schalm O, Adams F, Rindby A, Knöchel A, Simionovici AS, Snigirev A, X-ray spectrometry 29, 73 (2000). http://doi.org/10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
|
“Automated segmentation of μ-XRF image sets”. Vekemans B, Janssens K, Vincze L, Aerts A, Adams F, Hertogen J, X-ray spectrometry 26, 333 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
|