“Fundamental studies on a planar-cathode direct current glow discharge: part 2: numerical modeling and comparison with laser scattering experiments”. Bogaerts A, Gijbels R, Gamez G, Hieftje GM, Spectrochimica acta: part B : atomic spectroscopy 59, 449 (2004). http://doi.org/10.1016/j.sab.2003.12.001
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 26
DOI: 10.1016/j.sab.2003.12.001
|
“Effect of laser parameters on laser ablation and laser-induced plasma formation: a numerical modeling investigation”. Bogaerts A, Chen Z, Spectrochimica acta: part B : atomic spectroscopy 60, 1280 (2005). http://doi.org/10.1016/j.sab.2005.06.009
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 165
DOI: 10.1016/j.sab.2005.06.009
|
“Colloquium Spectroscopicum Internationale 34, Antwerp (Belgium), 4-9 September 2005: preface”. Bogaerts A, Janssens K, van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 61, 373 (2006). http://doi.org/10.1016/j.sab.2006.04.011
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 2
DOI: 10.1016/j.sab.2006.04.011
|
“Multiplicity and contiguity of ablation mechanisms in laser-assisted analytical micro-sampling”. Bleiner D, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 61, 421 (2006). http://doi.org/10.1016/j.sab.2006.02.007
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 48
DOI: 10.1016/j.sab.2006.02.007
|
“Calculation of rate constants for asymmetric charge transfer, and their effect on relative sensitivity factors in glow discharge mass spectrometry”. Bogaerts A, Temelkov KA, Vuchkov NK, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 62, 325 (2007). http://doi.org/10.1016/j.sab.2007.03.010
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 28
DOI: 10.1016/j.sab.2007.03.010
|
“Computer simulations of sample chambers for laser ablation-inductively coupled plasma spectrometry”. Bleiner D, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 62, 155 (2007). http://doi.org/10.1016/j.sab.2007.02.010
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
DOI: 10.1016/j.sab.2007.02.010
|
“Composition of 12-18th century window glass in Belgium : non-figurative windows in secular buildings and stained-glass windows in religious buildings”. Schalm O, Janssens K, Wouters H, Caluwé, D, Spectrochimica acta: part B : atomic spectroscopy
T2 –, 18th International Congress on X-Ray Optics and Microanalysis, September 25-30, 2005, National Institute of Nuclear Physics, Frascati, Italy 62, 663 (2007). http://doi.org/10.1016/J.SAB.2007.03.006
Abstract: A set of ca. 500 window glass fragments originating from different historical sites in Belgium and covering the period 12(th)- 18(th) century was analyzed by rneans of electron probe microanalysis. Most samples are archaeological finds deriving from non-figurative windows in secular buildings. However. the analyzed set also contains glass sampled from still existing non-figurative windows in secular buildings and stained-glass windows in religious buildings. A sudden compositional change at the end of the 14(th) century can be noticed among the series of glass compositions that were obtained. These changes could be related to the use of different glassmaker recipes and to the introduction of new raw materials for glass making. (c) 2007 Elsevier B.V All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 50
DOI: 10.1016/J.SAB.2007.03.006
|
“Design analysis of a laser ablation cell for inductively coupled plasma mass spectrometry by numerical simulation”. Autrique D, Bogaerts A, Lindner H, Garcia CC, Niemax K, Spectrochimica acta: part B : atomic spectroscopy 63, 257 (2008). http://doi.org/10.1016/j.sab.2007.11.032
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 26
DOI: 10.1016/j.sab.2007.11.032
|
“Double pulse laser ablation and laser induced breakdown spectroscopy: a modeling investigation”. Bogaerts A, Chen Z, Autrique D, Spectrochimica acta: part B : atomic spectroscopy 63, 746 (2008). http://doi.org/10.1016/j.sab.2008.04.005
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 56
DOI: 10.1016/j.sab.2008.04.005
|
“Monte Carlo analysis of the electron thermalization process in the afterglow of a microsecond dc pulsed glow discharge”. Martín A, Bordel N, Pereiro R, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 63, 1274 (2008). http://doi.org/10.1016/j.sab.2008.09.012
Abstract: A Monte Carlo model is utilized for studying the behavior of electrons in the afterglow of an analytical microsecond dc pulsed glow discharge. This model uses several quantities as input data, such as electric field and potential, ion flux at the cathode, the fast argon ion and atom impact ionization rates, slow electron density, the electrical characterization of the pulse (voltage and current profiles) and temperature profile. These quantities were obtained by earlier Monte Carlo fluid calculations for a pulsed discharge. Our goal is to study the behavior of the so-called Monte Carlo electrons (i.e., those electrons created at the cathode or by ionization collisions in the plasma which are followed by using the Monte Carlo model) from their origin to the moment when they are absorbed at the cell walls or when they have lost their energy by collisions (being transferred to the group of slow electrons) in the afterglow of the pulsed discharge. The thermalization of the electrons is a phenomenon where the electron-electron Coulomb collisions acquire a special importance. Indeed, in the afterglow the cross sections of the other electron reactions taken into account in the model are very low, because of the very low electron energy. We study the electron energy distributions at several times during and after the pulse and at several positions in the plasma cell, focusing on the thermalization and on the behavior of the electrons in the afterglow. Also, the time evolution of the rates of the various collision processes, the average electron energy, the densities of Monte Carlo and slow electrons and the ionization degree are investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 9
DOI: 10.1016/j.sab.2008.09.012
|
“mu-X-ray fluorescence and mu-X-ray diffraction investigations of sediment from the Ruprechtov nuclear waste disposal natural analog site”. Denecke MA, de Nolf W, Janssens K, Brendebach B, Falkenberg G, Noseck U, Rothkirch A, Spectrochimica acta: part B : atomic spectroscopy 63, 484 (2008). http://doi.org/10.1016/J.SAB.2008.01.001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2008.01.001
|
“Effects of oxygen addition to argon glow discharges: a hybrid Monte Carlo-fluid modeling investigation”. Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 64, 1266 (2009). http://doi.org/10.1016/j.sab.2009.10.003
Abstract: A hybrid model is developed for describing the effects of oxygen addition to argon glow discharges. The species taken into account in the model include Ar atoms in the ground state and the metastable level, O2 gas molecules in the ground state and two metastable levels, O atoms in the ground state and one metastable level, O3 molecules, Ar+, O+, O2+ and O− ions, as well as the electrons. The hybrid model consists of a Monte Carlo model for electrons and fluid models for the other plasma species. In total, 87 different reactions between the various plasma species are taken into account. Calculation results include the species densities and the importance of their production and loss processes, as well as the dissociation degree of oxygen. The effect of different O2 additions on these calculation results, as well as on the sputtering rates, is discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 39
DOI: 10.1016/j.sab.2009.10.003
|
“Enamels in stained glass windows: preparation, chemical composition, microstructure and causes of deterioration”. Schalm O, van der Linden V, Frederickx P, Luyten S, van der Snickt G, Caen J, Schryvers D, Janssens K, Cornelis E, van Dyck D, Schreiner M, Spectrochimica acta: part B : atomic spectroscopy 64, 812 (2009). http://doi.org/10.1016/j.sab.2009.06.005
Abstract: Stained glass windows incorporating dark blue and purple enamel paint layers are in some cases subject to severe degradation while others from the same period survived the ravages of time. A series of dark blue, greenblue and purple enamel glass paints from the same region (Northwestern Europe) and from the same period (16early 20th centuries) has been studied by means of a combination of microscopic X-ray fluorescence analysis, electron probe micro analysis and transmission electron microscopy with the aim of better understanding the causes of the degradation. The chemical composition of the enamels diverges from the average chemical composition of window glass. Some of the compositions appear to be unstable, for example those with a high concentration of K2O and a low content of CaO and PbO. In other cases, the deterioration of the paint layers was caused by the less than optimal vitrification of the enamel during the firing process. Recipes and chemical compositions indicate that glassmakers of the 1617th century had full control over the color of the enamel glass paints they made. They mainly used three types of coloring agents, based on Co (dark blue), Mn (purple) and Cu (light-blue or greenblue) as coloring elements. Bluepurple enamel paints were obtained by mixing two different coloring agents. The coloring agent for redpurple enamel, introduced during the 19th century, was colloidal gold embedded in grains of lead glass.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
Impact Factor: 3.241
Times cited: 28
DOI: 10.1016/j.sab.2009.06.005
|
“Hybrid Monte Carlo: fluid model for studying the effects of nitrogen addition to argon glow discharges”. Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 64, 126 (2009). http://doi.org/10.1016/j.sab.2008.11.004
Abstract: A computer model is developed for describing argon/nitrogen glow discharges. The species taken into account in the model include electrons, Ar atoms in the ground state and in the 4s metastable levels, N2 molecules in the ground state and in six different electronically excited levels, N atoms, Ar+ ions, N+, N2+, N3+ and N4+ ions. The fast electrons are simulated with a Monte Carlo model, whereas all other species are treated in a fluid model. 74 different chemical reactions are considered in the model. The calculation results include the densities of all the different plasma species, as well as information on their production and loss processes. The effect of different N2 additions, in the range between 0.1 and 10%, is investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 49
DOI: 10.1016/j.sab.2008.11.004
|
“Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies”. de Nolf W, Jaroszewicz J, Terzano R, Lind OC, Salbu B, Vekemans B, Janssens K, Falkenberg G, Spectrochimica acta: part B : atomic spectroscopy 64, 775 (2009). http://doi.org/10.1016/J.SAB.2009.06.003
Abstract: The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.30.5° are obtained at the bending magnet source when a pink beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.10.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2009.06.003
|
“Spatially resolved micro-X-ray fluorescence and micro-X-ray absorption fine structure study of a fractured granite bore core following a radiotracer experiment”. Denecke MA, Brendebach B, de Nolf W, Falkenberg G, Janssens K, Simon R, Spectrochimica acta: part B : atomic spectroscopy 64, 791 (2009). http://doi.org/10.1016/J.SAB.2009.05.025
Abstract: Spatially resolved X-ray absorption and fluorescence investigation with a micrometer-scale resolution on actinide-containing samples provide information necessary for safety assessment of nuclear waste disposal. In this paper one example of such an experiment is presented. This example entails neptunium speciation in a fractured granite bore core from the Swedish Äspö Hard Rock Laboratory following a radiotracer experiment using µ-XAFS and µ-XRF. In order to probe micro-volumes below the surface in the granite samples and thereby avoid potential changes in the Np speciation during cutting of the bore core, a confocal irradiationdetection geometry is employed. µ-XAFS results for a selected granite bore core cross section with ~ 3 nmol Np/g reveal that Np, originally introduced as Np(V) in the tracer cocktail, is present in the granite in its reduced Np(IV) form. The Np(IV) is often present as particles, tens of µm in size. Elemental distribution maps show the tracer Np to be located in fissures and permeable channels not larger than 100 µm. The Np distribution appears often correlated with Zn also present in some fissures. We observe small granite fissures containing Fe (presumably Fe(II)), where we do not detect any Np. It is feasible that inflowing Np(V) has a shorter residence time in large fractures, while in the smaller fissures migration is slower, leading to longer residence times, i.e., reaction times, where it is reduced to less soluble Np(IV) and becomes thereby immobilized.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 21
DOI: 10.1016/J.SAB.2009.05.025
|
“The influence of laser-particle interaction in laser induced breakdown spectroscopy and laser ablation inductively coupled plasma spectrometry”. Lindner H, Loper KH, Hahn DW, Niemax K, Spectrochimica acta: part B : atomic spectroscopy 66, 179 (2011). http://doi.org/10.1016/j.sab.2011.01.002
Abstract: Particles produced by previous laser shots may have significant influence on the analytical signal in laser-induced breakdown spectroscopy (LIBS) and laser ablation inductively coupled plasma (LA-ICP) spectrometry if they remain close to the position of laser sampling. The effects of these particles on the laser-induced breakdown event are demonstrated in several ways. LIBS-experiments were conducted in an ablation cell at atmospheric conditions in argon or air applying a dual-pulse arrangement with orthogonal pre-pulse, i.e., plasma breakdown in a gas generated by a focussed laser beam parallel and close to the sample surface followed by a delayed crossing laser pulse in orthogonal direction which actually ablates material from the sample and produces the LIBS plasma. The optical emission of the LIBS plasma as well as the absorption of the pre-pulse laser was measured. In the presence of particles in the focus of the pre-pulse laser, the plasma breakdown is affected and more energy of the pre-pulse laser is absorbed than without particles. As a result, the analyte line emission from the LIBS plasma of the second laser is enhanced. It is assumed that the enhancement is not only due to an increase of mass ablated by the second laser but also to better atomization and excitation conditions favored by a reduced gas density in the pre-pulse plasma. Higher laser pulse frequencies increase the probability of particle-laser interaction and, therefore, reduce the shot-to-shot line intensity variation as compared to lower particle loadings in the cell. Additional experiments using an aerosol chamber were performed to further quantify the laser absorption by the plasma in dependence on time both with and without the presence of particles. The overall implication of laser-particle interactions for LIBS and LA-ICP-MS/OES are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 12
DOI: 10.1016/j.sab.2011.01.002
|
“Multi-element model for the simulation of inductively coupled plasmas : effects of helium addition to the central gas stream”. Lindner H, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 66, 421 (2011). http://doi.org/10.1016/j.sab.2011.04.007
Abstract: A model for an atmospheric pressure inductively coupled plasma (ICP) is developed which allows rather easy extension to a variable number of species and ionisation degrees. This encompasses an easy calculation of transport parameters for mixtures, ionisation and heat capacity. The ICP is modeled in an axisymmetric geometry, taking into account the gas streaming into a flowing ambient gas. A mixture of argon and helium is applied in the injector gas stream as it is often done in laser ablation ICP spectrometry. The results show a strong influence of the added helium on the center of the ICP, which is important for chemical analysis. The length of the central channel is significantly increased and the temperature inside is significantly higher than in the case of pure argon. This means that higher gas volume flow rates can be applied by addition of helium compared to the use of pure argon. This has the advantage that the gas velocity in the transport system towards the ICP can be increased, which allows shorter washout-times. Consequently, shorter measurement times can be achieved, e.g. for spatial mapping analyses in laser ablation ICP spectrometry. Furthermore, the higher temperature and the longer effective plasma length will increase the maximum size of droplets or particles injected into the ICP that are completely evaporated at the detection site. Thus, we expect an increase of the analytical performance of the ICP by helium addition to the injector gas.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 28
DOI: 10.1016/j.sab.2011.04.007
|
“Optimization of operating parameters for inductively coupled plasma mass spectrometry : a computational study”. Aghaei M, Lindner H, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 76, 56 (2012). http://doi.org/10.1016/j.sab.2012.06.006
Abstract: An inductively coupled plasma, connected to a mass spectrometer interface, is computationally investigated. The effect of pressure behind the sampler, injector gas flow rate, auxiliary gas flow rate, and applied power is studied. There seems to be an optimum range of injector gas flow rate for each setup which guaranties the presence and also a proper length of the central channel in the torch. Moreover, our modeling results show that for any specific purpose, it is possible to control that either only the central gas flow passes through the sampler orifice or that it is accompanied by the auxiliary gas flow. It was also found that depending on geometry, the variation of outgoing gas flow rate is much less than the variation of the injector gas flow rate and this causes a slightly higher pressure inside the torch. The general effect of increasing the applied power is a rise in the plasma temperature, which results in a higher ionization in the coil region. However, the negative effect is reducing the length of the cool central channel which is important to transfer the sample substances to the sampler. Using a proper applied power can enhance the efficiency of the system. Indeed, by changing the gas path lines, the power can control which flow (i.e., only from injector gas or also from the auxiliary gas) goes to the sampler orifice. Finally, as also reported from experiments in literature, the pressure behind the sampler has no dramatic effect on the plasma characteristics.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 18
DOI: 10.1016/j.sab.2012.06.006
|
“Experimental determination of the energy distribution of ions bombarding the cathode surface in a glow discharge”. van Straaten M, Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 50, 583 (1995). http://doi.org/10.1016/0584-8547(94)00158-R
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.176
Times cited: 22
DOI: 10.1016/0584-8547(94)00158-R
|
“Monte Carlo simulation of an analytical glow discharge: motion of electrons, ions and fast neutrals in the cathode dark space”. Bogaerts A, van Straaten M, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 50, 179 (1995). http://doi.org/10.1016/0584-8547(94)00117-E
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.176
Times cited: 95
DOI: 10.1016/0584-8547(94)00117-E
|
“Plasma diagnostics of an analytical Grimm-type glow discharge in argon and in neon: Langmuir probe and optical emission spectroscopy measurements”. Bogaerts A, Quentmeier A, Jakubowski N, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 50, 1337 (1995). http://doi.org/10.1016/0584-8547(95)01356-5
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.176
Times cited: 37
DOI: 10.1016/0584-8547(95)01356-5
|