“Real-time electrochemical screening of cocaine in lab and field settings with automatic result generation”. de Jong M, Van Echelpoel R, Langley AR, Eliaerts J, van den Berg J, De Wilde M, Somers N, Samyn N, De Wael K, Drug testing and analysis 14, 1471 (2022). http://doi.org/10.1002/DTA.3276
Abstract: This work presents the results of a novel application for the fast on-site screening of cocaine and its main cutting agents in suspicious and confiscated samples. The methodology behind the novel application consists of portable electrochemical detection coupled with a peak-recognition algorithm for automated result output generation, validated both in laboratory and field settings. Currently used field tests, predominantly colorimetric tests, are lacking accuracy, often giving false positive or negative results. This presses the need for alternative approaches to field testing. By combining portable electrochemical approaches with peak-recognition algorithms, an accuracy of 98.4% concerning the detection of cocaine was achieved on a set of 374 powder samples. In addition, the approach was tested on multiple 'smuggled', colored cocaine powders and cocaine mixtures in solid and liquid states, typically in matrices such as charcoal, syrup and clothing. Despite these attempts to hide cocaine, our approach succeeded in detecting cocaine during on-site screening scenarios. This feature presents an advantage over colorimetric and optical detection techniques, which can fail with colored sample matrices. This enhanced accuracy on smuggled samples will lead to increased efficiency in confiscation procedures in the field, thus significantly reducing societal economic and safety concerns and highlighting the potential for electrochemical approaches in on-the-spot identification of drugs of abuse.
Keywords: A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1002/DTA.3276
|
|
|
“Resolution of opiate illicit drugs signals in the presence of some cutting agents with use of a voltammetric sensor array and machine learning strategies”. Ortiz-Aguayo D, Ceto X, De Wael K, del Valle M, Sensors and actuators : B : chemical 357, 131345 (2022). http://doi.org/10.1016/J.SNB.2021.131345
Abstract: In the present work, the resolution and quantification of mixtures of different opiate compounds in the presence of common cutting agents using an electronic tongue (ET) is evaluated. More specifically, ternary mixtures of heroin, morphine and codeine were resolved in the presence of caffeine and paracetamol. To this aim, an array of three carbon screen-printed electrodes were modified with different ink-like solutions of graphite, cobalt (II) phthalocyanine and palladium, and their responses towards the different drugs were characterized by means of square wave voltammetry (SWV). Developed sensors showed a good performance with good linearity at the mu M level, LODs between 1.8 and 5.3 mu M for the 3 actual drugs, and relative standard deviation (RSD) ca. 2% for over 50 consecutive measurements. Next, a quantitative model that allowed the identification and quantification of the individual substances from the overlapped voltammograms was built using partial least squares regression (PLS) as the modeling tool. With this approach, quantification of the different drugs was achieved at the mu M level, with a total normalized root mean square error (NRMSE) of 0.084 for the test subset.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.SNB.2021.131345
|
|
|
“The role of singlet oxygen, superoxide, hydroxide, and hydrogen peroxide in the photoelectrochemical response of phenols at a supported highly fluorinated zinc phthalocyanine”. Neven L, Barich H, Pelmuş, M, Gorun SM, De Wael K, ChemElectroChem 9, e202200108 (2022). http://doi.org/10.1002/CELC.202200108
Abstract: Photoelectrochemical (PEC) sensing of phenolic compounds using singlet oxygen (1O2)-generating photocatalysts has emerged as a powerful detection tool. However, it is currently not known how experimental parameters, such as pH and applied potential, influence the generation of reactive oxygen species (ROS) and their photocurrents. In this article, the PEC response was studied over the 6 to 10 pH range using a rotating (ring) disk (R(R)DE) set-up in combination with quenchers, to identify the ROS formed upon illumination of a supported photosensitizer, F64PcZn. The photocurrents magnitude depended on the applied potential and the pH of the buffer solution. The anodic responses were caused by the oxidation of O2.−, generated due to the quenching of 1O2 with −OH and the reaction of 3O2 with [F64Pc(3-)Zn]. The cathodic responses were assigned to the reduction of 1O2 and O2.−, yielding H2O2. These insights may benefit 1O2 – based PEC sensing applications.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1002/CELC.202200108
|
|
|
“Shuffling atomic layer deposition gas sequences to modulate bimetallic thin films and nanoparticle properties”. Filez M, Feng J-Y, Minjauw MM, Solano E, Poonkottil N, Van Daele M, Ramachandran RK, Li C, Bals S, Poelman H, Detavernier C, Dendooven J, Filez M, Minjauw M, Solano E, Poonkottil N, Li C, Bals S, Dendooven J, Chemistry of materials (2022). http://doi.org/10.1021/acs.chemmater.2c01304
Abstract: Atomic layer deposition (ALD) typically employs metal precursors and co-reactant pulses to deposit thin films in a layer-by-layer fashion. While conventional ABAB-type ALD sequences implement only two functionalities, namely, a metal source and ligand exchange agent, additional functionalities have emerged, including etching and reduction agents. Herein, we construct gas-phase sequences-coined as ALD+-with complex-ities reaching beyond the classic ABAB-type ALD by freely combining multiple functionalities within irregular pulse schemes, e.g., ABCADC. The possibilities of such combinations are explored as a smart strategy to tailor bimetallic thin films and nanoparticle (NP) properties. By doing so, we demonstrate that bimetallic thin films can be tailored with target thickness and through the full compositional range, while the morphology can be flexibly modulated from thin films to NPs by shuI 1ing the pulse sequence. These complex pulse schemes are expected to be broadly applicable but are here explored for Pd-Ru bimetallic thin films and NPs.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 2
DOI: 10.1021/acs.chemmater.2c01304
|
|
|
“Singlet oxygen-based photoelectrochemical detection of DNA”. Thiruvottriyur Shanmugam S, Trashin S, De Wael K, Biosensors and bioelectronics 195, 113652 (2022). http://doi.org/10.1016/J.BIOS.2021.113652
Abstract: The current work, designed for the photoelectrochemical detection of DNA, evaluates light-responsive DNA probes carrying molecular photosensitizers generating singlet oxygen (1O2). We take advantage of their chromophore’s ability to produce 1O2 upon photoexcitation and subsequent photocurrent response. Type I, fluorescent and type II photosensitizers were studied using diode lasers at 406 nm blue, 532 nm green and 659 nm red lasers in the presensce and absence of a redox reporter, hydroquinone (HQ). Only type II photosensitizers (producing 1O2) resulted in a noticeable photocurrent in 1–4 nA range upon illumination, in particular, dissolved DNA probes labeled with chlorin e6 and erythrosine were found to give a well-detectable photocurrent response in the presence of HQ. Whereas, Type I photosensitizers and fluorescent chromophores generate negligible photocurrents (<0.15 nA). The analytical performance of the sensing system was evaluated using a magnetic beads-based DNA assay on disposable electrode platforms, with a focus to enhance the sensitivity and robustness of the technique in detecting complementary DNA targets. Amplified photocurrent responses in the range of 70–100 nA were obtained and detection limits of 17 pM and 10 pM were achieved using magnetic beads-captured chlorin e6 and erythrosine labeled DNA probes respectively. The presented novel photoelectrochemical detection can further be optimized and employed in applications for which enzymatic amplification such as polymerase chain reaction (PCR) is not applicable owing to their limitations and as an effective alternative to colorimetric detection when rapid detection of specific nucleic acid targets is required.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.BIOS.2021.113652
|
|
|
Thiruvottriyur Shanmugam S (2022) Singlet oxygen-based photoelectrochemical detection of nucleic acids. 217 p
Abstract: MicroRNAs (miRNAs) are small oligonucleotides (18-25 bases) that play a key role in epigenetic regulation. Since the discovery of miRNAs in 1993, their role in biological processes has been extensively investigated. By now, it has been evidenced that monitoring and detection of miRNAs can improve (early) disease diagnosis. The existing diagnostic approaches have limitations such as the need for complex multistep protocols for sample preparation, analysis, data interpretation, high cost of equipment, the need for highly qualified personnel, and high laboratory standards. As opposed to this, point-of-care biosensors and chips aim to facilitate the procedure and avoid sending samples into centralized laboratories, which saves time, reduces the chance of sample degradation, and enables analysis of patient samples in remote areas, directly at home or primary and secondary care facilities (i.e. general practitioners and specialists). The latter is essential for therapy assessment and follow-up monitoring of patients with chronic diseases and cancer. Nevertheless, the development of such sensors is lagging compared to the projections of 10 – 20 years ago, mainly due to insufficient sensitivity, poor reproducibility, and the complexity of the sensors’ design reported in the research literature. This motivates the development of new detection strategies and technologies such as photoelectrochemical sensors that combine the best features of different sensing approaches. The primary concern when developing detection technologies for miRNA is the need for a highly sensitive and selective platform. This thesis explores a novel photoelectrochemical (PEC) method that is distinctive owing to its sensitive nature and simple and robust design. Firstly, we focused on the usage of recently emerging commercial gold-sputtered electrode systems for the detection of short nucleic acid with enzymatic amplification. Importantly, cleaning such electrodes is a challenge since the standard procedures known for regular disk electrodes such as polishing cannot be employed here, since it will damage the protective layer on the electrode. However, the electrodes can be washed and pretreated chemically and/or electrochemically. Thus, a procedure to effectively clean and modify the gold-sputtered electrode has been developed, resulting in high-performance gold-sputtered nucleic acid sensors. Next, the usage of molecular photosensitizers as an alternative to enzymatic amplification has been evaluated. We took advantage of the singlet oxygen production by photosensitizers upon photoexcitation, leading to a photocurrent response due to the singlet oxygen-induced (electro)chemical conversions. Following the demonstration of the detection strategy, the analytical performance of the sensing system was evaluated using magnetic beads-based nucleic acid assay on disposable electrode platforms, with a focus to enhance the sensitivity and robustness of the technique in detecting complementary nucleic acid targets. Following the fundamental evaluation of the singlet oxygen-based PEC detection of nucleic acids, we further optimized the assay and measurement parameters and employed the sensing strategy for a polymerase chain reaction-free (PCR-free) quantification of miRNAs related to prostate cancer. By successfully detecting and quantifying low-picomolar range concentrations (< 10 pM) in plasma samples from prostate cancer patients, we successfully showed the applicability of the novel sensing strategy. We have also compared and positioned the performance of our developed PEC strategy with an existing state-of-art technique, i.e. electrochemiluminescence (ECL). Our PEC strategy performed on par with ECL, both yielding low-picomolar detection limits in serum matrices, however quicker and cheaper than ECL. Owing to the versatility of this PEC technique, the final study explored its multiplexing capability. As a starting point in this branch of the research, we have investigated two possible ways for multiplexing. To perform multiple measurements at the same time, constructing calibration plots and quantifying unknown miRNA concentrations in patient samples at the same time, we have developed a high-throughput detection with 96X multi-channel electrode systems and in-house designed and constructed 96XLED illumination sources. Secondly, to detect more than one target miRNA in a single measurement, intra-vial multiplexing where the samples were analyzed for different targets in one vial was also explored. Altogether, this thesis presents the fundamentals, development and application of a novel PEC strategy for detecting short (< 25 bases) nucleic acid sequences, in particular, miRNA. With an aim to serve as a distinctive technique to function as a clinical testing platform without any need for PCR, this work adds value to the development of nucleic acid-based sensors for miRNAs and other short-stranded nucleic acid biomarkers, and benefits in the early detection of diseases like cancer.
Keywords: Doctoral thesis; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
|
|
|
Neven L (2022) Singlet oxygen-based photoelectrochemical detection of phenolic contaminants. 234 p
Abstract: Phenolic compounds can be found everywhere in our daily lives but exhibit high toxicity, low (bio)degradability and hormone-disrupting effects when they are released in the environment. It is for this reason imperative to develop detection strategies for these pollutants. A promising approach involves the use of a photoelectrochemical (PEC) sensor. In this sensor, a photosensitiser (PS) type II, which generates 1O2 under illumination, is used to oxidise phenolic compounds present in the sample. The oxidised phenols are reduced at the electrode surface leading to the generation of an electrocatalytic redox cycle. In this thesis, an in-depth understanding, through the identification of the reactive oxygen species (ROS) in the PEC sensing mechanism, is obtained. The detection strategy is optimised by choosing the PS with the highest 1O2 production and by optimising the detection parameters so that the PEC sensor can be successfully applied for the detection of phenols in industrial samples. First, it was determined that the use of highly fluorinated zinc phthalocyanine derivatives, F52PcZn and F64PcZn, as photocatalysts was optimal for the sensing of phenol due to their high 1O2 production and improved single-site isolation. However, next to 1O2, it was shown that the ROS O2•- and H2O2 were also generated in the PEC sensor. Their contribution to the photocurrent response was studied by rotating disk electrode measurements in function of the pH and applied potential. After this, the PEC detection strategy was optimised in terms of pH and applied potential for the detection of doxycycline, cefadroxil, and phenol. It was found that the use of alkaline pH-levels led to nmol L-1-level detection limits. The combination with square wave voltammetry (SWV) was, also, proposed to allow the quantification and identification of phenolic compounds in a specific sample. At last, the developed PEC and SWV sensors were applied for the measurement of phenolic compounds in industrial water samples. The PEC sensor could follow the decrease of the phenolic concentration throughout the wastewater treatment process while the SWV sensor provided the electrochemical fingerprints of these samples. The thesis concluded that the use of the PEC sensor was advantageous in the measurement of lower concentrated phenolic samples due to its high sensitivity and fast measurement time in comparison to commercial test kits.
Keywords: Doctoral thesis; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
|
|
|
“Strain-Induced Exciton Hybridization in WS2 Monolayers Unveiled by Zeeman-Splitting Measurements”. Blundo E, Faria PE Jr, Surrente A, Pettinari G, Prosnikov MA, Olkowska-Pucko K, Zollner K, Wozniak T, Chaves A, Kazimierczuk T, Felici M, Babinski A, Molas MR, Christianen PCM, Fabian J, Polimeni A, Physical review letters 129, 067402 (2022). http://doi.org/10.1103/PHYSREVLETT.129.067402
Abstract: Mechanical deformations and ensuing strain are routinely exploited to tune the band gap energy and to enhance the functionalities of two-dimensional crystals. In this Letter, we show that strain leads also to a strong modification of the exciton magnetic moment in WS2 monolayers. Zeeman-splitting measurements under magnetic fields up to 28.5 T were performed on single, one-layer-thick WS2 microbubbles. The strain of the bubbles causes a hybridization of k-space direct and indirect excitons resulting in a sizable decrease in the modulus of they factor of the ground-state exciton. These findings indicate that strain may have major effects on the way the valley number of excitons can be used to process binary information in two-dimensional crystals.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
DOI: 10.1103/PHYSREVLETT.129.067402
|
|
|
“Supercapacitive biofuel cells”. Pankratova G, Bollella P, Pankratov D, Gorton L, Current opinion in biotechnology 73, 179 (2022). http://doi.org/10.1016/J.COPBIO.2021.08.008
Abstract: Supercapacitive biofuel cells' (SBFCs) most recent advancements are herein disclosed. In conventional SBFCs the biocomponent is employed as the pseudocapacitive component, while in self-charging biodevices it also works as the biocatalyst. The performance of different types of SBFCs are summarized according to the categorization based on the biocatalyst employed: supercapacitive microbial fuel cells (sMFCs), supercapacitive biophotovoltaics (SBPV) and supercapacitive enzymatic fuel cells (s-EFCs). SBFCs could be considered as promising 'alternative' energy devices (low-cost, environmentally friendly, and technically undemanding electric power sources etc.) being suitable for powering a new generation of miniaturized electronic applications.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.COPBIO.2021.08.008
|
|
|
“Wearable hollow microneedle sensing patches for the transdermal electrochemical monitoring of glucose”. Parrilla M, Detamornrat U, Domínguez-Robles J, Donnelly RF, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 249, 123695 (2022). http://doi.org/10.1016/J.TALANTA.2022.123695
Abstract: According to the World Health Organization, about 422 million people worldwide have diabetes, with 1.5 million deaths directly attributed each year. Therefore, there is still a need to effectively monitor glucose in diabetic patients for proper management. Recently, wearable patches based on microneedle (MN) sensors provide minimally invasive analysis of glucose through the interstitial fluid (ISF) while exhibiting excellent correlation with blood glucose. Despite many advances in wearable electrochemical sensors, long-term stability and continuous monitoring remain unsolved challenges. Herein, we present a highly stable electrochemical biosensor based on a redox mediator bilayer consisting of Prussian blue and iron-nickel hexacyanoferrate to increase the long-term stability of the readout coupled with a hollow MN array as a sampling unit for ISF uptake. First, the enzymatic biosensor is developed by using affordable screen-printed electrodes (SPE) and optimized for long-term stability fitting the physiological range of glucose in ISF (i.e., 2.5–22.5 mM). In parallel, the MN array is assessed for minimally invasive piercing of the skin. Subsequently, the biosensor is integrated with the MN array leaving a microfluidic spacer that works as the electrochemical cell. Interestingly, a microfluidic channel connects the cell with an external syringe to actively and rapidly withdraw ISF toward the cell. Finally, the robust MN sensing patch is characterized during in vitro and ex vivo tests. Overall, affordable wearable MN-based patches for the continuous monitoring of glucose in ISF are providing an advent in wearable devices for rapid and life-threatening decision-making processes.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.TALANTA.2022.123695
|
|
|
“Wearable wristband-based electrochemical sensor for the detection of phenylalanine in biofluids”. Parrilla M, Vanhooydonck A, Watts R, De Wael K, Biosensors and bioelectronics 197 (2022). http://doi.org/10.1016/J.BIOS.2021.113764
Abstract: Wearable electrochemical sensors are driven by the user-friendly capability of on-site detection of key biomarkers for health management. Despite the advances in biomolecule monitoring such as glucose, still, several unmet clinical challenges need to be addressed. For example, patients suffering from phenylketonuria (PKU) should be able to monitor their phenylalanine (PHE) level in a rapid, decentralized, and affordable manner to avoid high levels of PHE in the body which can lead to a profound and irreversible mental disability. Herein, we report a wearable wristband electrochemical sensor for the monitoring of PHE tackling the necessity of controlling PHE levels in PHE hydroxylase deficiency patients. The proposed electrochemical sensor is based on a screen-printed electrode (SPE) modified with a membrane consisting of Nafion, to avoid interferences in biofluids. The membrane also consists of sodium 1,2-naphthoquinone-4-sulphonate for the in situ derivatization of PHE into an electroactive product, allowing its electrochemical oxidation at the surface of the SPE in alkaline conditions. Importantly, the electrochemical sensor is integrated into a wristband configuration to enhance user interaction and engage the patient with PHE self-monitoring. Besides, a paper-based sampling strategy is designed to alkalinize the real sample without the need for sample pretreatment, and thus simplify the analytical process. Finally, the wearable device is tested for the determination of PHE in saliva and blood serum. The proposed wristband-based sensor is expected to impact the PKU self-monitoring, facilitating the daily lives of PKU patients toward optimal therapy and disease management.
Keywords: A1 Journal article; Engineering sciences. Technology; Product development; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.BIOS.2021.113764
|
|
|
“Characteristic mosaic texture related to orderingin AuCu-9at.%Ag pseudobinary alloy”. Yasuda K, Hisatsune K, Udoh K, Tanaka Y, Van Tendeloo G, van Landuyt J, Dentistry in Japan 29, 91 (1992)
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT)
|
|
|
“Characterization of complex silver halide photographic systems by means of analytical electron microscopy”. Oleshko V, Gijbels R, Jacob W, Alfimov M, Microbeam analysis 4, 1 (1995)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 9
|
|
|
“Characterization of complex silver halide photographic systems by means of analytical electron microscopy”. Oleshko V, Gijbels R, Jacob W, Alfimov M, Microbeam analysis 3, 1 (1994)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“EM study of twinning in the Ni5Al3 bainitic phase”. Schryvers D, Ma Y, Toth L, Tanner LE, Twinning in advanced materials , 395 (1993)
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT)
|
|
|
“High field magnetotransport in a Ga0.8In0.2As quantum well with a parallel δ-layer”. van der Burgt M, Karavolas VC, Peeters FM, Singleton J, Nicholas RJ, Herlach F, Harris JJ, van Hove M, Borghs G, , 588 (1995)
Keywords: P3 Proceeding; Condensed Matter Theory (CMT)
|
|
|
“New erbium silicide superstructures: a study by high resolution electron microscopy”. Frangis N, Van Tendeloo G, van Landuyt J, Kaltsas G, Travlos A, Nassiopoulos AG, Physica status solidi: A: applied research 158, 107 (1996)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 6
|
|
|
“Stability of the superconducting vortex structure around a magnetic dot”. Marmorkos IK, Matulis A, Peeters FM, Physics of low-dimensional structures 10/11, 77 (1995)
Keywords: A3 Journal article; Condensed Matter Theory (CMT)
|
|
|
“Stabilization of mercury-based superconductors by foreign cations”. Raveau B, Michel C, Hervieu M, Van Tendeloo G, Maignan A, Annales de chimie (1914)
T2 –, 4th North-African Materials Science Symposium (JMSM 94), NOV 23-24, 1994, CASABLANCA, MOROCCO 19, 487 (1994)
Abstract: The recently discovered superconducting mercury-based cuprates HgBa2Can-1CunO2n+2+delta have proved difficult to synthesize as single phases and are sensitive to environment (CO2, moisture). The present paper gives an overview of new series mercury based superconductors, whose stabilisation is based on the fact that a foreign cation with a higher valency than Hg(II) must be introduced in the mercury layers, in order to fill up partially the oxygen vacancies of these layers. By this method, several new series of superconductors involving strontium instead of barium with critical temperatures ranging from 27 K to 95 K have been isolated : Hg0.5Bi0.5Sr2-xLaxCuO4+delta, Hg(0.5)Bi(0.5)Sr(2)Ca(1-x)R(x)Cu(2)O(6+delta) (R Y, Nd, Pr), Pb0.7Hg0.3Sr2-xLaxCuO4+delta, Pb(0.7)Hg(0.3)Sr(2)Ca(1-x)R(x)Cu(2)O(6+delta) (R = Y, Nd) Hg(1-x)Pr(x)Sr(2)A(1-x')Pr(x') Cu2O6+delta (A = Sr, Ca), Pb0.7Hg0.3Sr2Cu2CO3O7 and Hg1-xCrxSr2CuO4+delta. The behaviour of the praseodymium cuprates that exhibit a rather sharp transition and reach a Tc of 85 K is especially discussed. A method to synthesize new ''Ba-Hg'' superconducting cuprates with the 1212 structure at normal pressure with a Tc up to 110 K is also presented.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 2
|
|
|
“Statistical grouping and controlling factors of dissolved trace elements in a surface water system”. Vandelannoote R, Blommaert W, Van 't dack L, Gijbels R, van Grieken R, Environmental technology letters 4, 363 (1983). http://doi.org/10.1080/09593338309384219
Abstract: Sensitive multi‐element analytical techniques were applied to determine 24 dissolved trace components in 25 different water samples from a 10 km2 zone in Brittany, France. Correspondence factor and multiple regression analyses showed that the elements considered are influenced mainly by the presence of: Fe‐Mn oxide accumulations, a local poly‐metallic sulfide mineralization, and non‐mineralized host rocks, agricultural activity and abundant organic material in local swamps. Via these numerical techniques the location of the poly‐metallic ore body can be derived from the data set.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 1
DOI: 10.1080/09593338309384219
|
|
|
“Strong-coupling limit for one-dimensional polarons in a finite box”. Vansant P, Smondyrev MA, Peeters FM, Devreese JT, Zeitschrift für Physik: B: condensed matter and quanta 99, 345 (1996). http://doi.org/10.1007/s002570050047
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Theory of quantum systems and complex systems
Times cited: 1
DOI: 10.1007/s002570050047
|
|
|
“Structural analysis of silver halide cubic microcrystals with epitaxial or conversion growths by STEM-EDX”. Wu S, van Daele A, Jacob W, Gijbels R, Verbeeck A, de Keyzer R, Mikrochimica acta: supplementum 12, 261 (1992)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Study of quasi-fractal many-particle-systems and percolation networks by zero-loss spectroscopic imaging, electron energy-loss spectroscopy and digital image analysis”. Oleshko V, Kindratenko V, Gijbels R, van Espen P, Jacob W, Mikrochimica acta: supplementum 13, 443 (1996)
Abstract: Submicron colloidal Ag particles and nano-sized filaments forming a statistical percolation network during ''in situ'' development of double structure tabular microcrystals of AgRr(I) emulsions have been studied by electron energy-loss spectroscopy and zero-loss electron spectroscopic imaging (EELS/ZLESI). Image analysis has shown that random quasi-fractal clusters were formed in the colloid. ZLESI has been applied to characterise the morphology and defect structure of aggregated particles and filaments. Their energy-loss spectra revealed plasmon excitations and interband 4d electron transitions between 4-32 eV energy-loss. To study the cluster structure and its relation to the physical properties, fractal analysis including estimations of cluster fractal dimensions and of density autocorrelation functions has been performed. Mechanisms of fractal aggregation based on known models of diffusion limited aggregation, cluster-cluster aggregation and percolation are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
|
|
|
“Sur l'équilibre hydrogéochimique “solution –, suspension&rdquo, dans les systèmes hydrothermaux du socle cristallin”. Pentcheva EN, Veldeman E, Van 't dack L, Gijbels R, Doklady Bolgarskoi Akademii Nauk 49, 65 (1996)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“The chirality of carbon nanotubules determined by dark-field electron microscopy”. Bernaerts D, op de Beeck M, Amelinckx S, van Landuyt J, Van Tendeloo G, Philosophical magazine: A: physics of condensed matter: defects and mechanical properties 74, 723 (1996). http://doi.org/10.1080/01418619608243538
Abstract: Multishell carbon nanotubules are studied by means of diffraction contrast dark field images. This results in an electron microscopy method for the determination of the sign of the chiral angles in carbon nanotubes. The method is justified by a reasoning either in direct space or in diffraction space. We also investigate a carbon nanotubule exhibiting a bend and we confront the observations with the heptagon-pentagon pair model.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 20
DOI: 10.1080/01418619608243538
|
|
|
“Geothermal water analysis by X-ray fluorescence and neutron activation”. van Grieken R, Gijbels R, Blommaert W, Vandelannoote R, Van 't dack L US Energy Research and Development Administration, S.l., page 368 (1978).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Gold mobility in waters from temperate regions”. Cidu R, Fanfani L, Shand P, Edmunds WM, Van 't dack L, Gijbels R, (1995)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Nonlinear Schrödinger equation on a ring”. Smondyrev MA, Vansant P, Peeters FM, Devreese JT, JINR communications (1994)
Keywords: A3 Journal article; Condensed Matter Theory (CMT); Theory of quantum systems and complex systems
|
|
|
“Optically detected magnetophonon resonance in GaAs-GaAlAs heterojunctions”. Barnes DJ, Nicholas RJ, Watts M, Peeters FM, Wu XG, Devreese JT, Langerak CJ, Singleton J, Harris JJ, Foxon CT, (1991)
Keywords: P3 Proceeding; Condensed Matter Theory (CMT); Theory of quantum systems and complex systems
|
|
|
“Structural evolution of Bi2Sr2CaCu2O8+\delta single crystals studies by “in situ&rdquo, heating electron microscopy”. Zhang XF, Van Tendeloo G, Philosophical magazine: A: physics of condensed matter: defects and mechanical properties 70, 549 (1994)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 5
|
|