|
“Geothermal water analysis by X-ray fluorescence and neutron activation”. van Grieken R, Gijbels R, Blommaert W, Vandelannoote R, Van 't dack L US Energy Research and Development Administration, S.l., page 368 (1978).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Gold mobility in waters from temperate regions”. Cidu R, Fanfani L, Shand P, Edmunds WM, Van 't dack L, Gijbels R, (1995)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Statistical grouping and controlling factors of dissolved trace elements in a surface water system”. Vandelannoote R, Blommaert W, Van 't dack L, Gijbels R, van Grieken R, Environmental technology letters 4, 363 (1983). http://doi.org/10.1080/09593338309384219
Abstract: Sensitive multi‐element analytical techniques were applied to determine 24 dissolved trace components in 25 different water samples from a 10 km2 zone in Brittany, France. Correspondence factor and multiple regression analyses showed that the elements considered are influenced mainly by the presence of: Fe‐Mn oxide accumulations, a local poly‐metallic sulfide mineralization, and non‐mineralized host rocks, agricultural activity and abundant organic material in local swamps. Via these numerical techniques the location of the poly‐metallic ore body can be derived from the data set.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 1
DOI: 10.1080/09593338309384219
|
|
|
“Sulfur species and associated trace elements in south-west Bulgarian thermal waters”. Veldeman E, Van 't dack L, Gijbels R, Pentcheva E, Applied geochemistry 6, 49 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.268
Times cited: 7
|
|
|
“Sur l'équilibre hydrogéochimique “solution –, suspension&rdquo, dans les systèmes hydrothermaux du socle cristallin”. Pentcheva EN, Veldeman E, Van 't dack L, Gijbels R, Doklady Bolgarskoi Akademii Nauk 49, 65 (1996)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Analysis of thermal waters by ICP-MS”. Veldeman E, Van 't dack L, Gijbels R, Campbell M, Vanhaecke F, Vanhoe H, Vandecasteele C The Royal Society of Chemistry, Cambridge, page 25 (1991).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
Gijbels R, van Grieken R, Blommaert W, Van 't dack L, van Espen P, Nullens H, Saelens R (1983) Application of analytical methods for trace elements in geothermal waters : part 2 : Plombières, Bains-les-Bains, Bourbonne (Vosges). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Application of trace element analysis to geothermal waters”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 429 (1977)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Comportement hydrogéochimique des éléments traces au cours de l'interaction eau –, roche en milieu alcalin”. Pentcheva EN, Petrov PS, Veldeman E, Van 't dack L, Gijbels R, Doklady Bolgarskoi Akademii Nauk 43, 51 (1990)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Conductivity and electron density of undoped model compounds of poly(phenylene vinylene)”. Yang Z, Geise HJ, Mehbod M, Debrue G, Visser JW, Sonneveld EJ, Van 't dack L, Gijbels R, Synthetic metals 39, 137 (1990). http://doi.org/10.1016/0379-6779(90)90179-O
Abstract: Fourteen derivatives of trans,trans-1,4-bis[2-phenylethenyl]benzene were synthesized by Wittig reactions as model compounds of poly(paraphenylene vinylene). Structure, configurational homogeneity and absence of ionic impurities were controlled by mass spectrometry, infrared and neutron activation analysis, respectively. Crystallographic unit cell parameters were obtained from X-ray powder patterns and measurements of electrical conductivities were performed on undoped samples. The data of four more compounds containing one or more thiophene rings instead of phenyl rings were added from the 3iterature. If NO2 and Cl groups are excluded from the electron count a good linear correlation is found between the logarithm of the conductivity and the non-σ electron density (View the MathML source). The position of the substituents, on the central or on the terminal ring, also plays a role in as much as it affects the molecular volume of the compound but not the non-σ electron density. The correlation between the logarithm of the conductivity and the absorption coefficient of the longest wavelength of UV absorption identifies the π electrons in the chromophore as the principal charge carriers.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.252
Times cited: 25
DOI: 10.1016/0379-6779(90)90179-O
|
|
|
“Determination of gold at the ultratrace level in natural waters”. Cidu R, Fanfani L, Shaud P, Edmunds WM, Van 't dack L, Gijbels R, Analytica chimica acta 296, 295 (1994). http://doi.org/10.1016/0003-2670(94)80249-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 20
DOI: 10.1016/0003-2670(94)80249-1
|
|
|
“Determination of precious metals in ores and rocks by thermal neutron activation/\gamma-spectrometry after preconcentration by nickel sulphide fire assay and coprecipitation with tellurium”. Shazali I, Van 't dack L, Gijbels R, Analytica chimica acta 196, 49 (1987). http://doi.org/10.1016/S0003-2670(00)83069-X
Abstract: The six platinum group elements (Ru, Rh, Pd, Os, Ir and Pt) can be determined in geological samples down to the μg kg−1 level, by using nickel sulphide fire assay and neutron activation of the residue ramaining after dissolution of the nickel sulphide button in concentrated hydrochloric acid. Losses for the platinum group elements during this dissolution step are usually insignificant, except when the elements are present at ultra-trace levels. The can be recovered from the filtrate by coprecipitation with tellerium. The latter approach also permits determination of silver, which is significantly lost in the hydrochloric acid treatment (recovery <98% instead of typically ≈ 10%). The coprecipitation with tellurium considerably improves the results for gold (recovery ≈ 95% instead of typically 75%).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 49
DOI: 10.1016/S0003-2670(00)83069-X
|
|
|
“Equilibrium constants for trace elements in natural waters”. Van 't dack L, Blommaert W, Vandelannoote R, Gijbels R, van Grieken R, Reviews in analytical chemistry 7, 297 (1983)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Études génétiques du système “eau thermale –, gaz –, roche&rdquo, sous l'influence de phénomènes volcaniques récents”. Pentcheva EN, Petrov PS, Van 't dack L, Gijbels R, Doklady Bolgarskoi Akademii Nauk 48, 99 (1995)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Hydrogeochemical exploration for gold in the Osilo area, Sardinia, Italy”. Cidu R, Fanfani L, Shand P, Edmunds WM, Van 't dack L, Gijbels R, Applied geochemistry 10, 517 (1995). http://doi.org/10.1016/0883-2927(95)00022-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.268
Times cited: 10
DOI: 10.1016/0883-2927(95)00022-4
|
|
|
“Interaction between rock-forming minerals and fluids under hydrothermal conditions : experiments with emphasis on the chemical composition of the minerals surface and on the trace element content of the aqueous phase”. Beusen J-M, Van 't dack L, Gijbels R, , 310 (1985)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“A mass spectrometric study of the dissolution behavior of sanidine”. Adriaens A, Van 't dack L, Adams F, Gijbels R, Microchimica acta 120, 139 (1995). http://doi.org/10.1007/BF01244427
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.741
Times cited: 1
DOI: 10.1007/BF01244427
|
|
|
“Multi-element trace analysis of geothermal waters : problems, characteristics and applicability”. Vandelannoote R, Blommaert W, Van 't dack L, van Grieken R, Gijbels R, , 523 (1985)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preconcentration of precious metals by tellurium sulphide fire-assay followed by instrumental neutron activation analysis”. Shazali I, Van 't dack L, Gijbels R, , 29 (1988)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Trace element geochemistry in thermal waters from Amélie-les-Bains (Eastern Pyrenees, France)”. Gijbels R, van Grieken R, Vandelannoote R, Blommaert W, Van 't dack L, , 123 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace element geochemistry in thermal waters from Plombières and Bains (Vosges)”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 396 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace element geochemistry of the system rock-thermal water –, suspended matter –, deposits in a granitic environment”. Pentcheva EN, Veldeman E, Van 't dack L, Gijbels R, , 1321 (1992)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 1
|
|
|
“Trace-element geochemistry of thermal water percolating through a karstic environment in the region of Saint Ghislain (Belgium)”. Blommaert W, Vandelannoote R, Sadurski A, Van 't dack L, Gijbels R, Journal of volcanology and geothermal research 19, 331 (1983). http://doi.org/10.1016/0377-0273(83)90117-8
Abstract: Five geothermal waters from the Mons area (southern Belgium) have been studied: one natural hot spring at Stambruges, one stagnant warm water from the inclined tunnels at Baudour, and three thermal waters from the drillholes at St. Ghislain, Ghlin and Douvrain, originating from the carbonate/anhydrite-bearing Visean strata, at depths of ca. 2600, 1550 and 1300 m, respectively. Multielement chemical analysis of the filtered water and its suspended matter > 0.4 μm) was carried out by instrumental neutron activation. Temperature in depth, calculated using the silica (chalcedony) chemical geothermometer, ranged from 75 to 88°C, in good agreement with experimentally determined values. Na/K and Na/K/Ca geothermometers yieilded erratic results, as expected from the geological environment in the aquifer. From the analytical data it can be calculated that the thermal waters of St. Ghislain, Ghlin and Douvrain are not only saturated with respect to chalcedony, but also to anhydrite, calcite, fluorite, barite, strontianite, and possibly zinc silicate, iron (III) hydroxide or siderite, albite, microcline, gibbsite and kaolinite. They are oversaturated with respect to muscovite. Data are also presented for the other thermal waters, and a cold spring water (Claire Fontaine, Stambruges). The similar trace-element composition of the thermal waters can be explained by percolation of the water in the same distant recharge zone, from where it descends, becomes heated at depth and rises along collapse breccia, and locally (Baudour, Stambruges) along fissures. The uptake of higher amounts of Ca, Mg, Sr and sulfate in St. Ghislain and Ghlin, as compared to Douvrain and Baudour is correlated with the boundary between the non-dissolved and dissolved evaporitic zones. This boundary is situated between St. Ghislain and Douvrain, and is roughly parallel with the direction of the groundwater flow (WNW).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.543
Times cited: 2
DOI: 10.1016/0377-0273(83)90117-8
|
|
|
“Trace-elemental anomalies in surface water near a small lead-zinc mineralization at Menez-Albot (Brittany, France)”. Vandelannoote R, Blommaert W, Sadurski A, Van 'T Dack L, Gijbels R, Van Grieken R, Bosch B, Leleu M, Rochon J, Sarcia C, Sureau JF;, Journal of geochemical exploration 20, 33 (1984). http://doi.org/10.1016/0375-6742(84)90088-8
Abstract: Sensitive multi-element analysis techniques were applied to water samples collected in the vicinity of a small Zn-Pb-Cu sulfide mineralization in the region of Menez-Albot (Finistère, France). The variation of the trace-element content along a local stream shows the presence of the mineralization, mainly through a simultaneous positive anomaly in solution for a group of about 10 elements (e.g. Ni, Cu, Zn, As, Sb) which are connected with this type of mineralization. The anomaly decreases steeply due to the influx of swamp water rich in Fe, Mn and organic matter. The precipitation barrier is reflected in the stream sediment composition. Contamination from fertilizers was observed in some samples.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.747
Times cited: 4
DOI: 10.1016/0375-6742(84)90088-8
|
|
|
“The use of surface analysis techniques and isotope mass spectrometry for the study of water-rock interactions of interest in hot-dry rock technology”. Adriaens A, van Nevel L, Van 't dack L, de Bièvre P, Adams F, Gijbels R, , 2541 (1995)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Analise de solos por meio de fluorescencia de raios-X nao-dispersiva”. Costa Dantas C, Da Silveira Dantas H, Van 't dack L, Van Grieken R, Química nova 4, 110 (1981)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Atmospheric trace element concentrations in Jerusalem, Israel”. Malenky B, Van Grieken R, Van 't dack L, Luria M, Atmospheric environment 17, 819 (1983). http://doi.org/10.1016/0004-6981(83)90432-8
Abstract: Trace elements found in aerosols were monitored in Jerusalem during the 1979 winter season utilizing an X-ray fluoresence technique. Most of the particulate mass was associated with the natural soil elements, such as Ca, Fe, K and Ti. Only a small fraction of the mass was comprised of elements clearly emitted from human sources, e.g. Pb, Br, V, Ni and Zn. An excellent correspondence was found between the enrichment factors observed in this study and those postulated for other parts of the world. However, the concentration of Ca and Sr in the Jerusalem suspended dust is substantially higher when compared with world averages of urban aerosols.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(83)90432-8
|
|
|
“Chemical composition of river sediments from the Indian sub-continent”. Subramanian V, Van 't dack L, Van Grieken R, Chemical geology 48, 271 (1985). http://doi.org/10.1016/0009-2541(85)90052-X
Abstract: River sediments from all of the major drainage basins (except the Indus) in the Indian sub-continent were collected and analysed by thin-film X-ray fluorescence technique (XRF) to determine their chemical composition. On the basis of analysis of more than 120 samples, average chemical compositions of river-borne sediments from the Indian sub-continent have been calculated. Also, average concentration values for sediments from each of the river basins, and the sub-continent average and the inter-basin differences are discussed in relation to weathering processes in the drainage basins. Comparisons have been made with the chemistry of sediments from the Bay of Bengal (which receives the bulk of sediments delivered by Indian rivers). Our observations are discussed in the light of average chemical composition of world-river sediments and the world surface rock exposed for continental weathering.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0009-2541(85)90052-X
|
|
|
“Effective sample weight from scatter peaks in energy-dispersive x-ray fluorescence”. van Espen P, Van 't dack L, Adams F, Van Grieken R, Analytical chemistry 51, 961 (1979). http://doi.org/10.1021/AC50043A042
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1021/AC50043A042
|
|
|
“Effects of alkaline aluminate waste dumping on seawater chemistry”. Vandelannoote R, Van 't dack L, Van Grieken R, Marine environmental research 21, 275 (1987). http://doi.org/10.1016/0141-1136(87)90050-X
Abstract: The alkaline aluminate waste, of which 10002000 tonnes are dumped a few times a year off the Belgian coast in the Southern Bight of the North Sea, contains 5·4% NaCl, 1·8% dissolved Al and 7·4% NaOH, in addition to traces of heavy metals and some aniline- and phenol-derivatives. The pH rises locally to 8-5 and the total Al-concentration reaches 120niglitre−1(corresponding to an initial waste dilution factor of only 150) in the 10-m wide track just beyond the discharging barge, but these decay quickly to pH 8·1 and 1 mg litre-1 in the 30-m wide track, 500m behind the barge. The relation between the waste concentration and seawater pH was studied. The white precipitate that forms immediately in the sea was identified as Mg6Al2CO3(OH)164H20 (hydrotalcite-manasseite like). No trace of it was found in the local sediments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0141-1136(87)90050-X
|
|