|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
|
|
“Monte Carlo simulation of X-ray fluorescence and scattering tomography experiments”. Vincze L, Janssens K, Vekemans B, Adams F page 328 (1999).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.363736
|
|
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
|
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
|
|
“Optics for X-ray microfluorescence to be used at the European synchrotron radiation facility”. Vincze L, Janssens K, Adams F, Advances in X-ray analysis 37, 553 (1994)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Optimization of tapered capillary optics for use at the microfocus beamline (ID 13) at the European Synchroton Radiation Facility”. Vincze L, Janssens K, Adams F, Rindby A, Engström P, Riekel C, Advances in X-ray analysis 41, 252 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Optimization of tapered capillary optics for use at the microfocus beamline (ID 13) at the European Synchroton Radiation Facility”. Vincze L, Janssens K, Adams F, Rindby A, Engström P, Advances in X-ray analysis 41, 252 (1998)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Parameters influencing focussing capabilities of capillary optics”. Vincze L, Janssens K, Adams F, Larsson S, Rindby A, Engstrom P, Microbeam Analysis 1995: Proceedings Of The 29th Annual Conference Of The Microbeam Analysis Society , 161 (1995)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The preparation and preliminary characterisation of eight geological MPI-DING reference glasses for in-site microanalysis”. Jochum KP, Dingwell DB, Rocholl A, Janssens K, Vincze L, et al, Geostandards newsletter 24, 87 (2000). http://doi.org/10.1111/J.1751-908X.2000.TB00590.X
Abstract: Eight silicate glasses were prepared by directly fusing and stirring 50-100 g each of basalt, andesite, komatiite, peridotite, rhyolite, and quartz-diorite. These are referred to as MPI-DING glasses and were made for the purpose of providing reference materials for geochemical, in-situ microanalytical work. Results from various analytical techniques indicate that individual glass fragments are well homogenised with respect to major and trace elements at the mu m to mm scale. Heterogeneities due to quench crystallisation of olivine have been observed in small and limited areas of the two komatiitic glasses. In order to obtain concentration values for as many elements as possible, the glasses were analysed by a variety of bulk and microanalytical methods in a number of laboratories. From the analytical data, preliminary reference values for more than sixty elements were calculated. The analytical uncertainties of most elements are estimated to be between 1% and 10%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1751-908X.2000.TB00590.X
|
|
|
“Provenance analysis of Roman glass from the 1st-6th century A.D”. Aerts A, Janssens K, Vincze L, Vekemans B, Adams F, Haller M, Radtke M, Knöchel A, HASYLAB Jahresbericht , 918 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“PXRF, \mu-XRF, vacuum \mu-XRF, and EPMA analysis of Email Champlevé, objects present in Belgian museums”. van der Linden V, Meesdom E, Devos A, van Dooren R, Nieuwdorp H, Janssen E, Balace S, Vekemans B, Vincze L, Janssens K, Microscopy and microanalysis 17, 674 (2011). http://doi.org/10.1017/S1431927611011950
Abstract: The enamel of 20 Email Champlevé objects dating between the 12th and 19th centuries was investigated by means of microscopic and portable X-ray fluorescence analysis (μ-XRF and PXRF). Seven of these objects were microsampled and the fragments were analyzed with electron probe microanalysis (EPMA) and vacuum μ-XRF to obtain quantitative data about the composition of the glass used to produce these enameled objects. As a result of the evolution of the raw materials employed to produce the base glass, three different compositional groups could be discriminated. The first group consisted of soda-lime-silica glass with a sodium source of mineral origin (with low K content) that was opacified by addition of calcium antimonate crystals. This type of glass was only used in objects made in the 12th century. Email Champlevé objects from the beginning of the 13th century onward were enameled with soda-lime-silica glass with a sodium source of vegetal origin. This type of glass, which has a higher potassium content, was opacified with SnO2 crystals. The glass used for 19th century Email Champlevé artifacts was produced with synthetic and purified components resulting in a different chemical composition compared to the other groups. Although the four analytical techniques employed in this study have their own specific characteristics, they were all found to be suitable for classifying the objects into the different chronological categories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.891
Times cited: 9
DOI: 10.1017/S1431927611011950
|
|
|
“Quantification of SY-XRF measurements at the X-ray microprobe”. Haller M, Radtke M, Knöchel A, Clöck W, Sutton S, Janssens K, Vincze L, HASYLAB Jahresbericht , 956 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Quantitative Fe determination inside tomato roots by confocal μ-XRF”. Terzano R, Spagnuolo M, Ruggiero P, Vekemans B, Scoonjans T, Vincze L, Janssens K, Tomasi N, Cesco S, Falkenberg G page 1513 (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Quantitative mu-XRF analysis of heterogeneous samples”. Vincze L, Janssens K, Adams F, Jones K, Microbeam Analysis 1995: Proceedings Of The 29th Annual Conference Of The Microbeam Analysis Society , 175 (1995)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Quantitative trace element analysis of individual fly ash particles by means of X-ray microfluorescence”. Vincze L, Somogyi A, Osán J, Vekemans B, Török S, Janssens K, Adams F, Analytical chemistry 74, 1128 (2002). http://doi.org/10.1021/AC010789B
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 44
DOI: 10.1021/AC010789B
|
|
|
“Recent trends in quantitative aspects of microscopic X-ray fluorescence analysis”. Janssens K, de Nolf W, van der Snickt G, Vincze L, Vekemans B, Terzano R, Brenker FE, Trends in analytical chemistry 29, 464 (2010). http://doi.org/10.1016/J.TRAC.2010.03.003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 48
DOI: 10.1016/J.TRAC.2010.03.003
|
|
|
“Simulation of poly-capillary lenses for coherent and partially coherent x-rays”. Vincze L, Kukhlevsky SV, Janssens K, Proceedings of the Society of Photo-optical Instrumentation Engineers
T2 –, Conference on Advances in Computational Methods for X-Ray and Neutron, Optics, AUG 03-05, 2004, Denver, CO , 81 (2004). http://doi.org/10.1117/12.560740
Abstract: The intensity distributions of the coherent and partially coherent x-rays passed through a poly-capillary lens have been computed at the focal plane. The computations showed that at the appropriate experimental conditions the interference phenomenon does affect the intensity distribution. In the case of the coherent input radiation with the photon energy of 0.1 keV, the interference fringes were observed, while the non-coherent x-ray radiation produced no interference-like intensity distributions.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 6
DOI: 10.1117/12.560740
|
|
|
“Spatially resolved (semi)quantitative determination of iron (Fe) in plants by means of synchrotron micro X-ray fluorescence”. Terzano R, Alfeld M, Janssens K, Vekemans B, Schoonjans T, Vincze L, Tomasi N, Pinton R, Cesco S, Analytical and bioanalytical chemistry 405, 3341 (2013). http://doi.org/10.1007/S00216-013-6768-6
Abstract: Iron (Fe) is an essential element for plant growth and development; hence determining Fe distribution and concentration inside plant organs at the microscopic level is of great relevance to better understand its metabolism and bioavailability through the food chain. Among the available microanalytical techniques, synchrotron mu-XRF methods can provide a powerful and versatile array of analytical tools to study Fe distribution within plant samples. In the last years, the implementation of new algorithms and detection technologies has opened the way to more accurate (semi)quantitative analyses of complex matrices like plant materials. In this paper, for the first time the distribution of Fe within tomato roots has been imaged and quantified by means of confocal mu-XRF and exploiting a recently developed fundamental parameter-based algorithm. With this approach, Fe concentrations ranging from few hundreds of ppb to several hundreds of ppm can be determined at the microscopic level without cutting sections. Furthermore, Fe (semi)quantitative distribution maps were obtained for the first time by using two opposing detectors to collect simultaneously the XRF radiation emerging from both sides of an intact cucumber leaf.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 27
DOI: 10.1007/S00216-013-6768-6
|
|
|
“Suitability of polycapillary optics for focusing of monochromatic synchrotron radiation as used in trace level micro-XANES measurements”. Vincze L, Wei F, Proost K, Vekemans B, Janssens K, He Y, Yan Y, Falkenberg G, Journal of analytical atomic spectrometry 17, 177 (2002). http://doi.org/10.1039/B110210A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/B110210A
|
|
|
“Synchrotron radiation-induced X-ray microanalysis”. Janssens K, Vincze L, Adams F, Jones KW, Analytica chimica acta 283, 98 (1993). http://doi.org/10.1016/0003-2670(93)85213-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(93)85213-4
|
|
|
“Synchrotron radiation induced X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Aerts A, Adams F, Jones KW, Knöchel A, Microchimica acta
T2 –, 4th Workshop of the European-Microanalysis-Society on Modern, Developments and Applications in Microbeam Analysis, MAY, 1995, ST MALO, FRANCE , 87 (1996)
Abstract: mu-XRF is the microscopic equivalent of the well-established multielement analytical technique. In this paper, after comparing the interaction of X-ray photons, electrons and protons with matter and an introduction to synchrotron rings and microfocussing of X-rays, the instrumentation for mu-XRF is discussed, both for laboratory source and synchrotron based setups and the analytical characteristics of mu-XRF are contrasted to that of other microanalytical techniques, Also, this issue of quantification of mu-XRF data is addressed; the applicability of the method in archeological and geological analysis is illustrated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace analysis allows to distinguish between Venetian and facon-de-Venise glass vessels of the 16th and 17th century”. de Raedt I, Janssens K, Veeckman J, Vincze L, Vekemans B, Jeffries T, Journal of analytical atomic spectrometry 16, 1012 (2001). http://doi.org/10.1039/B102597J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 49
DOI: 10.1039/B102597J
|
|
|
“Trace-level micro-XANES by means of bending magnets radiation focused with a polycapillary lens”. Vincze L, Janssens K, Wei F, Proost K, Vekemans B, Vittiglio G, Yan Y, Falkenberg G (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The use of lead-glass capillaries for microfocusing of highly energetic (0-60 KeV) synchrotron radiation”. Janssens K, Vincze L, Vekemans B, Adams F, Haller M, Knöchel A, Journal of analytical atomic spectrometry 13, 339 (1998). http://doi.org/10.1039/A707700I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707700I
|
|
|
“Use of microscopic XRF for non-destructive analysis in art an archaeometry”. Janssens K, Vittiglio G, Deraedt I, Aerts A, Vekemans B, Vincze L, Wei F, de Ryck I, Schalm O, Adams F, Rindby A, Knöchel A, Simionovici AS, Snigirev A, X-ray spectrometry 29, 73 (2000). http://doi.org/10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
|
|
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials”. Kempenaers L, Vincze L, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 55, 651 (2000). http://doi.org/10.1016/S0584-8547(00)00207-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00207-X
|
|
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials containing heavy metals”. Kempenaers L, Vincze L, Janssens K (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray optics for synchrotron-radiation-induced X-ray micro fluorescence at the european synchrotron-radiation facility, Grenoble”. Vincze L, Janssens K, Adams F, Institute of physics conference series , 613 (1993)
Abstract: Different optical designs for generating synchrotron x-ray micro beams suitable for use in an X-ray fluorescence microscope using an ESRF bending magnet X-ray source are compared. Attention is devoted to the spatial and energy distribution of the photons in the micro beam and to the minimum detection limits that are achievable with each alternative optical system.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Application of auxiliary signals in X-ray fluorescence and electron microprobe analysis for density evaluation”. Kuczumov A, Vekemans B, Schalm O, Vincze L, Dorriné, W, Gysels K, Van Grieken R, X-ray spectrometry 28, 282 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<282::AID-XRS352>3.0.CO;2-H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<282::AID-XRS352>3.0.CO;2-H
|
|
|
“Application of combined micro-proton-induced X-ray emission and micro-synchrotron radiation X-ray fluorescence techniques for the characterization of impact materials around Barringer Meteor Crater”. Uzonyi I, Szöör G, Vekemans B, Vincze L, Rozsa P, Szabo G, Somogyi A, Adams F, Kiss ÁZ, Spectrochimica acta: part B : atomic spectroscopy 59, 1717 (2004). http://doi.org/10.1016/J.SAB.2004.05.030
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2004.05.030
|
|