|
“A large area full-field EDXRF imaging system based on a THCOBRA gaseous detector”. Silva ALM, Carvalho ML, Janssens K, Veloso JFCA, Journal of analytical atomic spectrometry 30, 343 (2015). http://doi.org/10.1039/C4JA00301B
Abstract: By taking advantage of the attractive features in terms of gain, position and energy resolution of the 2D-THCOBRA detector, a new large area Full-Field X-ray Fluorescence Imaging (FF-XRFI) system for EDXRF imaging applications was developed. The proposed FF-XRFI system has an active area of 10 x 10 cm(2) and can be used to examine macroscopic samples with a moderately good energy resolution (< 1.6 keV FWHM at 8 keV) and a suitable spatial resolution (similar to 500 mu m FWHM). This combination of characteristics allows us to record elemental distribution maps from the surface of different sample types by combining image and energy information. Two different approaches were used for X-ray optics, one based on a single pinhole and another based on a parallel multiple-hole collimator. To illustrate the system capabilities, some sample examples were imaged and studied.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 11
DOI: 10.1039/C4JA00301B
|
|
|
“Quantification of boron in cells for evaluation of drug agents used in boron neutron capture therapy”. Verlinden B, Van Hoecke K, Aerts A, Daems N, Dobney A, Janssens K, Cardinaels T, Journal Of Analytical Atomic Spectrometry 36, 598 (2021). http://doi.org/10.1039/D0JA00456A
Abstract: Boron neutron capture therapy (BNCT) is an extensively studied radiotherapeutic strategy for cancer treatment. BNCT is based on irradiation of malignant tumour cells with neutrons after uptake of a B-10 containing molecule. Alpha particles, locally produced by neutron irradiation kill the cancer cells. Important for ongoing research regarding cellular uptake and cytotoxicity of a large variety of B-10 containing molecules is the accurate determination of boron concentrations in cell cultures. In this work, the sample preparation for quantitative inductively coupled plasma mass spectrometry (ICP-MS) analysis on cell cultures was optimized. By making use of acid digestion combined with UV digestion, low detection limits (0.4 mu g L-1) and full recoveries of boron could be achieved while measurements were free of spectral and non-spectral interferences. Finally, cell-associated boron in the form of 4-borono-l-phenylalanine (l-BPA) in vascular endothelial cell cultures could be determined with ICP-MS as (1.26 +/- 0.10) x 10(9) boron atoms per cell. The developed method can prove its importance for further BNCT research and elemental analysis of cell cultures.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/D0JA00456A
|
|
|
“Occurrence of gas flow rotational motion inside the ICP torch : a computational and experimental study”. Aghaei M, Flamigni L, Lindner H, Günther D, Bogaerts A, Journal of analytical atomic spectrometry 29, 249 (2014). http://doi.org/10.1039/c3ja50302j
Abstract: An inductively coupled plasma, connected to the sampling cone of a mass spectrometer, is computationally investigated. The occurrence of rotational motion of the auxiliary and carrier gas flows is studied. The effects of operating parameters, i.e., applied power and gas flow rates, as well as geometrical parameters, i.e., sampler orifice diameter and injector inlet diameter, are investigated. Our calculations predict that at higher applied power the auxiliary and carrier gas flows inside the torch move more forward to the sampling cone, which is validated experimentally for the auxiliary gas flow, by means of an Elan 6000 ICP-MS. Furthermore, an increase of the gas flow rates can also modify the occurrence of rotational motion. This is especially true for the carrier gas flow rate, which has a more pronounced effect to reduce the backward motion than the flow rates of the auxiliary and cooling gas. Moreover, a larger sampler orifice (e.g., 2 mm instead of 1 mm) reduces the backward flow of the auxiliary gas path lines. Finally, according to our model, an injector inlet of 2 mm diameter causes more rotations in the carrier gas flow than an injector inlet diameter of 1.5 mm, which can be avoided again by changing the operating parameters.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/c3ja50302j
|
|
|
“The effect of the sampling cone position and diameter on the gas flow dynamics in an ICP”. Aghaei M, Lindner H, Bogaerts A, Journal of analytical atomic spectrometry 28, 1485 (2013). http://doi.org/10.1039/c3ja50107h
Abstract: An inductively coupled plasma, connected to a sampling cone of a mass spectrometer, is computationally investigated. The effects of the sampler orifice diameter (ranging from 1 to 2 mm) and distance of the sampler cone from the load coil (ranging from 7 to 17 mm) are studied. An increase in sampler orifice diameter leads to a higher central plasma temperature at the place of the sampler, as well as more efficient gas transfer through the sampler, by reducing the interaction of the plasma gas with the sampling cone. However, the flow velocity at the sampler position is found to be independent of the sampler orifice diameter. Moreover, by changing the sampler orifice diameter, we can control whether only the central gas or also the auxiliary gas can exit through the sampler. Finally, with the increasing distance of the sampler from the load coil, the plasma temperature at the place of the sampler decreases slightly, which might also have consequences for the ion generation and transport through the sampling cone.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 14
DOI: 10.1039/c3ja50107h
|
|
|
“Effect of a mass spectrometer interface on inductively coupled plasma characteristics : a computational study”. Aghaei M, Lindner H, Bogaerts A, Journal of analytical atomic spectrometry 27, 604 (2012). http://doi.org/10.1039/c2ja10341a
Abstract: An inductively coupled plasma connected to a mass spectrometer interface (sampling cone) is computationally investigated. Typical plasma characteristics, such as gas flow velocity, plasma temperature and electron density, are calculated in two dimensions (cylindrical symmetry) and compared with and without a mass spectrometer sampling interface. The results obtained from our model compare favorably with experimental data reported in the literature. A dramatic increase in the plasma velocity is reported in the region close to the interface. Furthermore, a cooled metal interface lowers the plasma temperature and electron density on the axial channel very close to the sampling cone but the corresponding values in the off axial regions are increased. Therefore, the effect of the interface strongly depends on the measurement position. It is shown that even a small shift from the actual position of the sampler leads to a considerable change of the results.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 18
DOI: 10.1039/c2ja10341a
|
|
|
“Spectrometric determination of silicon in food and biological samples: an interlaboratory trial”. van Dyck K, Robberecht H, van Cauwenbergh R, Deelstra H, Arnaud J, Willemyns L, Benijts F, Centeno JA, Taylor H, Soares ME, Bastos ML, Ferreira MA, d'Haese PC, Lamberts LV, Hoenig M, Knapp G, Lugowski SJ, Moens L, Riondato J, Van Grieken R, Claes M, Verheyen R, Clement L, Uytterhoeven M, Journal of analytical atomic spectrometry 15, 735 (2000). http://doi.org/10.1039/B000572J
Abstract: Accuracy and precision of silicon determination in biological matrices (serum, urine, water, beer and spinach) by spectrometric techniques (when necessary after acid destruction) were assessed by means of a collaborative interlaboratory trial. The trial was set up in accordance with ISO 5725-2 (1994). The relative overall repeatability standard deviation was acceptable. It varied between 4% for spinach powder (mean content: 176 mg kg(-1)) and 11% for serum (mean content: 5.33 mg L-1). On the other hand, the relative overall between-laboratory standard deviation was found to vary from a satisfactorily 15% for spinach after destruction (mean content: 3.32 mg L-1) to an unacceptable 107% for spinach powder (mean content: 176 mg kg(-1)). The overall conclusion of the trial was that silicon determination in biological matrices can properly be performed by spectrometric techniques. However, when sample pretreatment (i.e., acid destruction) is needed prior to silicon determination problems still remain.
Keywords: A1 Journal article; Behavioural Ecology & Ecophysiology; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B000572J
|
|
|
“The darkening of copper- or lead-based pigments explained by a structural modification of natural orpiment : a spectroscopic and electrochemical study”. Vermeulen M, Sanyova J, Janssens K, Nuyts G, De Meyer S, De Wael K, Journal of analytical atomic spectrometry 32, 1331 (2017). http://doi.org/10.1039/C7JA00047B
Abstract: A combined Raman and electrochemical study of natural orpiment (As2S3), an arsenic sulfide pigment, was used to assess the quick formation of oxidized species such as arsenic oxide (As2O3) upon exposing the pigment to 405 nm or 532 nm monochromatic light while simultaneously recording the Raman spectra of the exposed sample. During this process, a distortion of the main band at 355 cm−1, associated with the stretching of the AsS3/2 pyramids of natural orpiment, was observed as well as an increased intensity of the 359 cm−1 band, corresponding to covalent AsAs bonds in natural orpiment. The distortion was accompanied by an overall decrease of the global Raman signal for natural orpiment, which could be explained by a loss in the crystal structure. The same phenomena were recorded in reference natural orpiment model paint samples stored for a long time together with verdigris (Cu(OH)2·(CH3COO)2·5H2O) and minium (Pb3O4) paints, the latter two appearing darkened on their sides closest to the orpiment sample as well as in several historical samples containing natural orpiment mixed with various blue pigments. By SEM-EDX and XRPD analysis, respectively on loose material and cast thin-sections of model paint samples, the darkening was identified as dark sulfide species such as chalcocite (Cu2S) and galena (PbS), suggesting the release of volatile sulfide or related species by the natural orpiment paint. XANES analyses of paint samples presenting AsAs bond increase indicated the presence of sulfur species most likely identified as organosulfur compounds formed upon the AsAs bond formation and explained the darkening of the Cu- and Pb-based pigments. To the best of our knowledge, this article reports for the first time the light-induced formation of AsAs bonds in natural orpiment used as an artists' pigment and objectively demonstrates the incompatibility between orpiment and (arsenic) sulfide-sensitive pigments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 10
DOI: 10.1039/C7JA00047B
|
|
|
“Full spectral XANES imaging using the Maia detector array as a new tool for the study of the alteration process of chrome yellow pigments in paintings by Vincent van Gogh”. Monico L, Janssens K, Alfeld M, Cotte M, Vanmeert F, Ryan CG, Falkenberg G, Howard DL, Brunetti BG, Miliani C, Journal of analytical atomic spectrometry 30, 613 (2015). http://doi.org/10.1039/C4JA00419A
Abstract: A combination of synchrotron radiation (SR) micro X-ray fluorescence (m-XRF) and XRF mode X-ray absorption near edge structure (XANES) measurements at the Cr K-edge already allowed us to establish that the photo-reduction of chromates to Cr(III) compounds is the cause of darkening of chrome yellow pigments (PbCr1-xSxO4, 0 <= x <= 0.8) in a number of paintings by Vincent van Gogh and in corresponding artificially aged paint models. A silicon drift detector (SDD) was employed to record the Cr-K XRF radiation in these X-ray micro beam-based measurements. However, in view of the limited count rate capabilities and collection solid angle of a single device, m-XRF and m-XANES employing single element SDDs (or similar) are primarily suited for collection of spectral data from individual points. Additionally, collection of XRF maps via point-by-point scanning with relatively long dwell times per point is possible but is usually confined to small areas. The development of the 384 silicon-diode array Maia XRF detector has provided valuable solutions in terms of data acquisition rate, allowing for full spectral (FS) XANES imaging in XRF mode, i.e., where spectroscopic information is available at each pixel in the scanned map. In this paper, the possibilities of SR Cr K-edge FS-XANES imaging in XRF mode using the Maia detector are examined as a new data collection strategy to study the speciation and distribution of alteration products of lead chromate-based pigments in painting materials. The results collected from two micro-samples taken from two Van Gogh paintings and an aged paint model show the possibility to perform FS-XANES imaging in practical time frames (from several minutes to a few hours) by scanning regions of sample sizes of the same order (more than 500 mm). The sensitivity and capabilities of FS-XANES imaging in providing representative chemical speciation information at the microscale (spatial resolution from similar to 2 to 0.6 mm) over the entire scanned area are demonstrated by the identification of Cr(OH) 3, Cr(III) sulfates and/or Cr(III) organometallic compounds in the corresponding phase maps, as alteration products. Comparable Cr-speciation results were obtained by performing equivalent higher spatial resolution SR m-XRF/single-point m-XANES analysis using a more conventional SDD from smaller regions of interest of each sample. Thus, large-area XRF mode FS-XANES imaging (Maia detector) is here proposed as a valuable and complementary data collection strategy in relation to “ zoomed-in” high-resolution m-XRF mapping and single-point m-XANES analysis (SDD).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 28
DOI: 10.1039/C4JA00419A
|
|
|
“The afterglow mystery of pulsed glow discharges and the role of dissociative electron-ion recombination”. Bogaerts A, Journal of analytical atomic spectrometry 22, 502 (2007). http://doi.org/10.1039/b618035c
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 56
DOI: 10.1039/b618035c
|
|
|
“Analysis of platinum powder by glow discharge mass spectrometry”. van Straaten M, Swenters K, Gijbels R, Verlinden J, Adriaenssens E, Journal of analytical atomic spectrometry 9, 1389 (1994). http://doi.org/10.1039/ja9940901389
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.466
Times cited: 17
DOI: 10.1039/ja9940901389
|
|
|
“Argon and copper optical emission spectra in a Grimm glow discharge source: mathematical simulations and comparison with experiment”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 13, 721 (1998). http://doi.org/10.1039/a802894j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 25
DOI: 10.1039/a802894j
|
|
|
“Calculation of cathode heating in analytical glow discharges”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 19, 1206 (2004). http://doi.org/10.1039/b400483c
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/b400483c
|
|
|
“Calculation of the gas flow and its effect on the plasma characteristics for a modified Grimm-type glow discharge cell”. Bogaerts A, Okhrimovskyy A, Gijbels R, Journal of analytical atomic spectrometry 17, 1076 (2002). http://doi.org/10.1039/b200746k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 39
DOI: 10.1039/b200746k
|
|
|
“Characterization of AgxAuy nano particles by TEM and STEM”. de Vyt A, Gijbels R, Davock H, van Roost C, Geuens I, Journal of analytical atomic spectrometry 14, 499 (1999). http://doi.org/10.1039/a807695b
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 2
DOI: 10.1039/a807695b
|
|
|
“Computer simulation of an analytical direct current glow discharge in argon: influence of the cell dimensions on the plasma quantities”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 12, 751 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
|
|
|
“Computer simulations of laser ablation sample introduction for plasma-source elemental microanalysis”. Bleiner D, Bogaerts A, Journal of analytical atomic spectrometry 21, 1161 (2006). http://doi.org/10.1039/b607627k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 22
DOI: 10.1039/b607627k
|
|
|
“Determination of scandium in high-purity titanium using inductively coupled plasma mass spectrometry and glow discharge mass spectrometry as part of its certification as a reference material”. Held A, Taylor P, Ingelbrecht C, de Bièvre P, Broekaert J, van Straaten M, Gijbels R, Journal of analytical atomic spectrometry 10, 849 (1995). http://doi.org/10.1039/ja9951000849
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.466
Times cited: 6
DOI: 10.1039/ja9951000849
|
|
|
“Effects of adding hydrogen to an argon glow discharge: overview of relevant processes and some qualitative explanations”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 441 (2000). http://doi.org/10.1039/a909779a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 58
DOI: 10.1039/a909779a
|
|
|
“The glow discharge: an exciting plasma”. Bogaerts A, Journal of analytical atomic spectrometry 14, 1375 (1999). http://doi.org/10.1039/a900772e
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 29
DOI: 10.1039/a900772e
|
|
|
“Glow discharge optical emission spectrometry: moving towards reliable thin film analysis: a short review”. Angeli J, Bengtson A, Bogaerts A, Hoffmann V, Hodoroaba V-D, Steers E, Journal of analytical atomic spectrometry 18, 670 (2003). http://doi.org/10.1039/b301293j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 75
DOI: 10.1039/b301293j
|
|
|
“Hybrid Monte Carlo-fluid model for a microsecond pulsed glow discharge”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 895 (2000). http://doi.org/10.1039/b003398g
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/b003398g
|
|
|
“Hydrogen addition to an argon glow discharge: a numerical simulation”. Bogaerts A, Journal of analytical atomic spectrometry 17, 768 (2002). http://doi.org/10.1039/b200025c
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 48
DOI: 10.1039/b200025c
|
|
|
“Improved hybrid Monte Carlo-fluid model for the electrical characteristics in an analytical radiofrequency glow discharge in argon”. Bogaerts A, Gijbels R, Goedheer W, Journal of analytical atomic spectrometry 16, 750 (2001). http://doi.org/10.1039/b103768b
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 11
DOI: 10.1039/b103768b
|
|
|
“Laser ablation of copper in different background gases: comparative study by numerical modeling and experiments”. Bogaerts A, Chen Z, Bleiner D, Journal of analytical atomic spectrometry 21, 384 (2006). http://doi.org/10.1039/b514313f
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 67
DOI: 10.1039/b514313f
|
|
|
“Modeling of a microsecond pulsed glow discharge: behavior of the argon excited levels and of the sputtered copper atoms and ions”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 16, 239 (2001). http://doi.org/10.1039/b009289o
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 36
DOI: 10.1039/b009289o
|
|
|
“Modeling of a millisecond pulsed glow discharge: investigation of the afterpeak”. Bogaerts A, Gijbels R, Jackson GP, Journal of analytical atomic spectrometry 18, 533 (2003). http://doi.org/10.1039/b212606k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 42
DOI: 10.1039/b212606k
|
|
|
“Modeling of argon direct current glow discharges and comparison with experiment: how good is the agreement?”.Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 13, 945 (1998). http://doi.org/10.1039/a800329g
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 24
DOI: 10.1039/a800329g
|
|
|
“Modeling study on the influence of the pressure on a dielectric barrier discharge microplasma”. Martens T, Bogaerts A, Brok WJM, van der Mullen JJAM, Journal of analytical atomic spectrometry 22, 1003 (2007). http://doi.org/10.1039/b704903j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 17
DOI: 10.1039/b704903j
|
|
|
“Nanosecond laser ablation of Cu: modeling of the expansion in He background gas, and comparison with expansion in vacuum”. Bogaerts A, Chen Z, Journal of analytical atomic spectrometry 19, 1169 (2004). http://doi.org/10.1039/b402946a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 39
DOI: 10.1039/b402946a
|
|
|
“Plasma diagnostics and numerical simulations: insight into the heart of analytical glow discharges”. Bogaerts A, Journal of analytical atomic spectrometry 22, 13 (2007). http://doi.org/10.1039/b611436a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/b611436a
|
|