“Filter absorption correction for X-ray fluorescence analysis of aerosol loaded filters”. Van Grieken R, Adams F, (1976)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“Processing of three-dimensional microscopic X-ray fluorescence data”. Vekemans B, Vincze L, Brenker FE, Adams F, Journal of analytical atomic spectrometry 19, 1302 (2004). http://doi.org/10.1039/B404300F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B404300F
|
|
|
“Quantitative X-ray fluorescence analysis at the ESRF ID18F microprobe”. Vekemans B, Vincze L, Somogyi A, Drakopoulos M, Kempenaers L, Simionovici AS, Adams F, Nuclear instruments and methods: B 199, 396 (2003). http://doi.org/10.1016/S0168-583X(02)01396-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0168-583X(02)01396-4
|
|
|
“Study of microgeometry of porous materials using synchrotron computed microtomography”. Jones KW, Feng H, Lindquist WB, Adler PM, Thover JF, Vekemans B, Vincze L, Szalóki I, Van Grieken R, Adams F, Riekel C page 39 (2003).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Synchrotron computed X-ray fluorescence microtomography in environmental and earth sciences”. Vincze L, Vekemans B, Adams F, (2003)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Synchrotron computed X-ray fluorescence tomography in environmental and earth sciences: radiation”. Vincze L, Vekemans B, Adams F, (2004)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Synchrotron radiation for microscopic X-ray fluorescence analysis”. Adams F, Vincze L, Vekemans B page 343 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Three-dimensional trace element analysis by confocal X-ray microfluorescence imaging”. Vincze L, Vekemans B, Brenker FE, Falkenberg G, Rickers K, Somogyi A, Kersten M, Adams F, Analytical chemistry 76, 6786 (2004). http://doi.org/10.1021/AC049274L
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC049274L
|
|
|
“A general Monte-Carlo simulation of energy-dispersive X-ray fluorescence spectrometers : 1 : unpolarized radiation, homogenious samples”. Vincze L, Janssens K, Adams F, Spectrochimica acta: part B : atomic spectroscopy 48, 553 (1993). http://doi.org/10.1016/0584-8547(93)80060-8
Abstract: A general Monte Carlo program for the simulation of X-ray fluorescence (XRF) spectrometers is presented. The global layout of the program is discussed and the way in which variance reduction techniques have been employed to improve the efficiency of the code is described. For the case of polychromatic excitation in a direct excitation energy-dispersive (ED) XRF instrument, experimentally collected ED-XRF spectra are compared with simulated spectral distributions. Applications of the software in the field of quantitative analysis and thickness estimation of samples of intermediate thickness illustrate the potential of the method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(93)80060-8
|
|
|
“The elemental composition of airborne particulate matter in the Atacama desert, Chile”. Rojas CM, Figueroa L, Janssens KH, Van Espen PE, Adams FC, Van Grieken RE, The science of the total environment 91, 251 (1990). http://doi.org/10.1016/0048-9697(90)90302-B
Abstract: Air particulate samples were collected at Chapiquiña near Arica (Chile) with a six-stage cascade impactor for about 17-day periods during a 31 month interval. Sixteen elements were determined by energy dispersive X-ray fluorescence analysis, and the elemental concentrations were subjected to principal factor analysis. The variability with time of the coarse particles was described by two factors both related to soil dispersion, whereas the fine particle variations could be explained by a third factor related to marine influence. Enrichment factors were compared with those obtained in other remote continental areas, in particular those of air particulate matter sampled at Chacaltaya, Bolivia. Results point to a negligible anthropogenic influence.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90302-B
|
|
|
“X-ray optics for synchrotron-radiation-induced X-ray micro fluorescence at the european synchrotron-radiation facility, Grenoble”. Vincze L, Janssens K, Adams F, Institute of physics conference series , 613 (1993)
Abstract: Different optical designs for generating synchrotron x-ray micro beams suitable for use in an X-ray fluorescence microscope using an ESRF bending magnet X-ray source are compared. Attention is devoted to the spatial and energy distribution of the photons in the micro beam and to the minimum detection limits that are achievable with each alternative optical system.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
|
|
“Capabilities and limitations of Fourier transform laser microprobe mass spectrometry for molecular analysis of solids”. Ignatova VA, van Vaeck L, Gijbels R, Adams F, Vacuum 69, 307 (2002). http://doi.org/10.1016/S0042-207X(02)00350-0
Abstract: Fourier transform laser microprobe mass spectrometry (FT LMMS) has been developed for the molecular analysis of both organic and inorganic components at the surface of microobjects with the ultimate specificity of high-mass resolution. These capabilities are needed in numerous applications of practical material analysis, such as tracing back anomalies in microobjects. The purpose of this paper is to address representative example from industrial trouble shooting, in which organic and inorganic analytes in a single microparticle have been identified unambiguously. This motivates the research to extend the methodology towards quantification. This paper deals with the fundamental aspect of information depth, specifically for inorganic molecular adduct ions. Finally, data will show the quantitative capabilities of FT LMMS. A suitable methodology for the preparation of reference specimens has allowed the empirical calibration of the response as a function of the local concentration to be achieved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.53
Times cited: 4
DOI: 10.1016/S0042-207X(02)00350-0
|
|
|
“X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation”. Vincze L, Vekemans B, Szaloki I, Brenker FE, Falkenberg G, Rickers K, Aerts K, Van Grieken R, Adams F, , 220 (2004). http://doi.org/10.1117/12.560416
Abstract: Ibis work illustrates the development of X-ray fluorescence tomography and polycapillary based confocal imaging towards a three-dimensional (313), quantitative analytical method with lateral resolution levels down to the 2-20 mum scale. Detailed analytical characterization is given for polycapillary based confocal XRF imaging, which is a new variant of the 3D micro-XRF technique. Applications for 2D/3D micro-XR-F are illustrated for the analysis of biological (zooplankton) and geological samples (microscopic inclusions in natural diamonds and fluid inclusions in quartz). Based on confocal imaging, fully three-dimensional distributions of trace elements could be obtained, representing a significant generalization of the regular 2D scanning technique for micro-XRF spectroscopy. The experimental work described in this paper has been carried out at the ESRF ID18F microfluorescence end-station and at HASYLAB Beam Line L.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.560416
|
|
|
“Lead particles in an urban atmosphere : an individual particle approach”. Van Borman W, Wouters L, Van Grieken R, Adams F, The science of the total environment 90, 55 (1990). http://doi.org/10.1016/0048-9697(90)90185-W
Abstract: In air particulate matter, sampled at a suburban site near the city of Antwerp, Belgium, more than 1500 individual Pb-containing aerosol particles with projected diameters between 0.2 and 15 μm were analyzed by automated electron probe X-ray micro analysis (EPXMA) for 26 elements and morphological features. Laser microprobe mass analysis (LAMMA) was used to detect elements with Z < 11, particularly ammonium compounds. The Pb-containing particles were classified into five main classes: Pb-sulfates, Pb-halides, soil related Pb, Pb associated with medium atomic number elements and Pb associated with high atomic number elements. Each class was divided into several distinct particle types, of which the abundance (in number and mass %), the mean projected particle diameter, and the chemical composition were determined. Auto exhaust products are responsible for Pb-sulfates and Pb-halides, making up respectively 66.7 and 27.8% by mass of the Pb-containing particles. Ammonium sulfate coatings were found to be present on nearly all Pb particles. The observations were correlated with daily concentrations of Pb and Br, obtained by particle induced X-ray emission analysis (PIXE).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90185-W
|
|
|
“Synchrotron radiation induced X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Aerts A, Adams F, Jones KW, Knöchel A, Microchimica acta
T2 –, 4th Workshop of the European-Microanalysis-Society on Modern, Developments and Applications in Microbeam Analysis, MAY, 1995, ST MALO, FRANCE , 87 (1996)
Abstract: mu-XRF is the microscopic equivalent of the well-established multielement analytical technique. In this paper, after comparing the interaction of X-ray photons, electrons and protons with matter and an introduction to synchrotron rings and microfocussing of X-rays, the instrumentation for mu-XRF is discussed, both for laboratory source and synchrotron based setups and the analytical characteristics of mu-XRF are contrasted to that of other microanalytical techniques, Also, this issue of quantification of mu-XRF data is addressed; the applicability of the method in archeological and geological analysis is illustrated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Accurate evaluation of \mu-PIXE and \mu-XRF spectral data through iterative least squares fitting”. Janssens K, Vekemans B, Adams F, van Espen P, Mutsaers P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 –, 7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY 26-30, 1995, Abano Terme, Italy 109, 179 (1996). http://doi.org/10.1016/0168-583X(95)01211-7
Abstract: The integration of the nonlinear least squares X-ray spectrum evaluation progam AXIL. into a mu-PIXE and a mu-XRF setup is discussed. The use of the software when procesing data sets derived from biological and geological samples is described.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0168-583X(95)01211-7
|
|
|
“Modeling of photon scattering at high X-ray energies : experiment versus simulation”. Vincze L, Vekemans B, Janssens K, Adams F, Journal of analytical atomic spectrometry
T2 –, 15th International Congress on X-Ray Optics and Microanalysis (ICXOM), AUG 24-27, 1998, ANTWERP, BELGIUM 14, 529 (1999). http://doi.org/10.1039/A808040B
Abstract: The use of a detailed Monte Carlo simulation code for X-ray fluorescence spectrometers is demonstrated for calculating the outcome of X-ray scattering experiments in the incident energy range 40-80 keV. The code was validated by comparisons of experimental and simulated spectral distributions in the case of thick, homogeneous samples in which multiple photon scattering occurs with high probability. The experimental spectral distributions were collected at beamline BW5 of HASYLAB, Germany, where a highly energetic, monochromatic synchrotron beam is available. With respect to heterogeneous samples, the code was employed to evaluate the use of Rayleigh and Compton scatter signals for obtaining three dimensional information on the sample dark matrix composition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A808040B
|
|