|
“Three-dimensional trace element analysis by confocal X-ray microfluorescence imaging”. Vincze L, Vekemans B, Brenker FE, Falkenberg G, Rickers K, Somogyi A, Kersten M, Adams F, Analytical chemistry 76, 6786 (2004). http://doi.org/10.1021/AC049274L
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC049274L
|
|
|
“A general Monte-Carlo simulation of energy-dispersive X-ray fluorescence spectrometers : 1 : unpolarized radiation, homogenious samples”. Vincze L, Janssens K, Adams F, Spectrochimica acta: part B : atomic spectroscopy 48, 553 (1993). http://doi.org/10.1016/0584-8547(93)80060-8
Abstract: A general Monte Carlo program for the simulation of X-ray fluorescence (XRF) spectrometers is presented. The global layout of the program is discussed and the way in which variance reduction techniques have been employed to improve the efficiency of the code is described. For the case of polychromatic excitation in a direct excitation energy-dispersive (ED) XRF instrument, experimentally collected ED-XRF spectra are compared with simulated spectral distributions. Applications of the software in the field of quantitative analysis and thickness estimation of samples of intermediate thickness illustrate the potential of the method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(93)80060-8
|
|
|
“X-ray optics for synchrotron-radiation-induced X-ray micro fluorescence at the european synchrotron-radiation facility, Grenoble”. Vincze L, Janssens K, Adams F, Institute of physics conference series , 613 (1993)
Abstract: Different optical designs for generating synchrotron x-ray micro beams suitable for use in an X-ray fluorescence microscope using an ESRF bending magnet X-ray source are compared. Attention is devoted to the spatial and energy distribution of the photons in the micro beam and to the minimum detection limits that are achievable with each alternative optical system.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Carbonates from the lower part of transition zone or even the lower mantle”. Brenker FE, Vollmer C, Vincze L, Vekemans B, Szymanski A, Janssens K, Szaloki I, Nasdala L, Joswig W, Kaminsky F, Earth and planetary science letters 260, 1 (2007). http://doi.org/10.1016/J.EPSL.2007.02.038
Abstract: Effective CO2-storage in the shallow solid Earth mainly occurs by the formation of carbonates. Although the possibility of transport and storage of carbonates to great depth is demonstrated experimentally, ultra-deep mantle carbonates have not been found before. Applying several in situ analytical techniques on inclusions in diamonds from Juina (Brazil) originating from the lower part of the transition zone (> 580 km) or even the lower mantle (> 670 km), reveal the existence of deep Earth carbonates. These finding unquestionably show that at least locally carbonates exist within the deep Earth and may indicate that the Earth's global CO2-cycle has an ultra-deep extension.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.409
Times cited: 156
DOI: 10.1016/J.EPSL.2007.02.038
|
|
|
“The preparation and preliminary characterisation of eight geological MPI-DING reference glasses for in-site microanalysis”. Jochum KP, Dingwell DB, Rocholl A, Janssens K, Vincze L, et al, Geostandards newsletter 24, 87 (2000). http://doi.org/10.1111/J.1751-908X.2000.TB00590.X
Abstract: Eight silicate glasses were prepared by directly fusing and stirring 50-100 g each of basalt, andesite, komatiite, peridotite, rhyolite, and quartz-diorite. These are referred to as MPI-DING glasses and were made for the purpose of providing reference materials for geochemical, in-situ microanalytical work. Results from various analytical techniques indicate that individual glass fragments are well homogenised with respect to major and trace elements at the mu m to mm scale. Heterogeneities due to quench crystallisation of olivine have been observed in small and limited areas of the two komatiitic glasses. In order to obtain concentration values for as many elements as possible, the glasses were analysed by a variety of bulk and microanalytical methods in a number of laboratories. From the analytical data, preliminary reference values for more than sixty elements were calculated. The analytical uncertainties of most elements are estimated to be between 1% and 10%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1751-908X.2000.TB00590.X
|
|
|
“X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation”. Vincze L, Vekemans B, Szaloki I, Brenker FE, Falkenberg G, Rickers K, Aerts K, Van Grieken R, Adams F, , 220 (2004). http://doi.org/10.1117/12.560416
Abstract: Ibis work illustrates the development of X-ray fluorescence tomography and polycapillary based confocal imaging towards a three-dimensional (313), quantitative analytical method with lateral resolution levels down to the 2-20 mum scale. Detailed analytical characterization is given for polycapillary based confocal XRF imaging, which is a new variant of the 3D micro-XRF technique. Applications for 2D/3D micro-XR-F are illustrated for the analysis of biological (zooplankton) and geological samples (microscopic inclusions in natural diamonds and fluid inclusions in quartz). Based on confocal imaging, fully three-dimensional distributions of trace elements could be obtained, representing a significant generalization of the regular 2D scanning technique for micro-XRF spectroscopy. The experimental work described in this paper has been carried out at the ESRF ID18F microfluorescence end-station and at HASYLAB Beam Line L.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.560416
|
|
|
“Spatially resolved (semi)quantitative determination of iron (Fe) in plants by means of synchrotron micro X-ray fluorescence”. Terzano R, Alfeld M, Janssens K, Vekemans B, Schoonjans T, Vincze L, Tomasi N, Pinton R, Cesco S, Analytical and bioanalytical chemistry 405, 3341 (2013). http://doi.org/10.1007/S00216-013-6768-6
Abstract: Iron (Fe) is an essential element for plant growth and development; hence determining Fe distribution and concentration inside plant organs at the microscopic level is of great relevance to better understand its metabolism and bioavailability through the food chain. Among the available microanalytical techniques, synchrotron mu-XRF methods can provide a powerful and versatile array of analytical tools to study Fe distribution within plant samples. In the last years, the implementation of new algorithms and detection technologies has opened the way to more accurate (semi)quantitative analyses of complex matrices like plant materials. In this paper, for the first time the distribution of Fe within tomato roots has been imaged and quantified by means of confocal mu-XRF and exploiting a recently developed fundamental parameter-based algorithm. With this approach, Fe concentrations ranging from few hundreds of ppb to several hundreds of ppm can be determined at the microscopic level without cutting sections. Furthermore, Fe (semi)quantitative distribution maps were obtained for the first time by using two opposing detectors to collect simultaneously the XRF radiation emerging from both sides of an intact cucumber leaf.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 27
DOI: 10.1007/S00216-013-6768-6
|
|
|
“The corrosion process of sterling silver exposed to a Na2S solution: monitoring and characterizing the complex surface evolution using a multi-analytical approach”. Schalm O, Crabbé, A, Storme P, Wiesinger R, Gambirasi A, Grieten E, Tack P, Bauters S, Kleber C, Favaro M, Schryvers D, Vincze L, Terryn H, Patelli A, Applied Physics A-Materials Science &, Processing 122, 903 (2016). http://doi.org/10.1007/s00339-016-0436-6
Abstract: Many historical ‘silver’ objects are composed of sterling silver, a silver alloy containing small amounts of copper. Besides the dramatic impact of copper on the corrosion process, the chemical composition of the corrosion layer evolves continuously. The evolution of the surface during the exposure to a Na2S solution was monitored by means of visual observation at macroscopic level, chemical analysis at microscopic level and analysis at the nanoscopic level. The corrosion process starts with the preferential oxidation of copper, forming mixtures of oxides and sulphides while voids are being created beneath the corrosion layer. Only at a later stage, the silver below the corrosion layer is consumed. This results in the formation of jalpaite and at a later stage of acanthite. The acanthite is found inside the corrosion layer at the boundaries of jalpaite grains and as individual grains between the jalpaite grains but also as a thin film on top of the corrosion layer. The corrosion process could be described as a sequence of 5 subsequent surface states with transitions between these states.
Keywords: A1 Journal article; Electron Microscopy for Materials Science (EMAT);
Impact Factor: 1.455
Times cited: 9
DOI: 10.1007/s00339-016-0436-6
|
|
|
“Synchrotron radiation induced X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Aerts A, Adams F, Jones KW, Knöchel A, Microchimica acta
T2 –, 4th Workshop of the European-Microanalysis-Society on Modern, Developments and Applications in Microbeam Analysis, MAY, 1995, ST MALO, FRANCE , 87 (1996)
Abstract: mu-XRF is the microscopic equivalent of the well-established multielement analytical technique. In this paper, after comparing the interaction of X-ray photons, electrons and protons with matter and an introduction to synchrotron rings and microfocussing of X-rays, the instrumentation for mu-XRF is discussed, both for laboratory source and synchrotron based setups and the analytical characteristics of mu-XRF are contrasted to that of other microanalytical techniques, Also, this issue of quantification of mu-XRF data is addressed; the applicability of the method in archeological and geological analysis is illustrated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Reclaiming the image of daguerreotypes: Characterization of the corroded surface before and after atmospheric plasma treatment”. Grieten E, Schalm O, Tack P, Bauters S, Storme P, Gauquelin N, Caen J, Patelli A, Vincze L, Schryvers D, Journal of cultural heritage (2017). http://doi.org/10.1016/j.culher.2017.05.008
Abstract: Technological developments such as atmospheric plasma jets for industry can be adapted for the conservation of cultural heritage. This application might offer a potential method for the removal or transformation of the corrosion on historical photographs. We focus on daguerreotypes and present an in-depth study of the induced changes by a multi-analytical approach using optical microscopy, scanning electron microscopy, different types of transmission electron microscopy and X-ray absorption fine structure. The H2-He afterglow removes S from an Ag2S or Cu2S layer which results in a nano-layer of metallic Ag or Cu on top of the deteriorated microstructure. In case the corrosion layer is composed of Cu-Ag-S compounds, our proposed setup can be used to partially remove the corrosion. These alterations of the corrosion results in an improvement in the readability of the photographic image.
Keywords: A1 Journal article; Art; History; Electron microscopy for materials research (EMAT); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 1.838
Times cited: 9
DOI: 10.1016/j.culher.2017.05.008
|
|
|
“PXRF, \mu-XRF, vacuum \mu-XRF, and EPMA analysis of Email Champlevé, objects present in Belgian museums”. van der Linden V, Meesdom E, Devos A, van Dooren R, Nieuwdorp H, Janssen E, Balace S, Vekemans B, Vincze L, Janssens K, Microscopy and microanalysis 17, 674 (2011). http://doi.org/10.1017/S1431927611011950
Abstract: The enamel of 20 Email Champlevé objects dating between the 12th and 19th centuries was investigated by means of microscopic and portable X-ray fluorescence analysis (μ-XRF and PXRF). Seven of these objects were microsampled and the fragments were analyzed with electron probe microanalysis (EPMA) and vacuum μ-XRF to obtain quantitative data about the composition of the glass used to produce these enameled objects. As a result of the evolution of the raw materials employed to produce the base glass, three different compositional groups could be discriminated. The first group consisted of soda-lime-silica glass with a sodium source of mineral origin (with low K content) that was opacified by addition of calcium antimonate crystals. This type of glass was only used in objects made in the 12th century. Email Champlevé objects from the beginning of the 13th century onward were enameled with soda-lime-silica glass with a sodium source of vegetal origin. This type of glass, which has a higher potassium content, was opacified with SnO2 crystals. The glass used for 19th century Email Champlevé artifacts was produced with synthetic and purified components resulting in a different chemical composition compared to the other groups. Although the four analytical techniques employed in this study have their own specific characteristics, they were all found to be suitable for classifying the objects into the different chronological categories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.891
Times cited: 9
DOI: 10.1017/S1431927611011950
|
|
|
“Simulation of poly-capillary lenses for coherent and partially coherent x-rays”. Vincze L, Kukhlevsky SV, Janssens K, Proceedings of the Society of Photo-optical Instrumentation Engineers
T2 –, Conference on Advances in Computational Methods for X-Ray and Neutron, Optics, AUG 03-05, 2004, Denver, CO , 81 (2004). http://doi.org/10.1117/12.560740
Abstract: The intensity distributions of the coherent and partially coherent x-rays passed through a poly-capillary lens have been computed at the focal plane. The computations showed that at the appropriate experimental conditions the interference phenomenon does affect the intensity distribution. In the case of the coherent input radiation with the photon energy of 0.1 keV, the interference fringes were observed, while the non-coherent x-ray radiation produced no interference-like intensity distributions.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 6
DOI: 10.1117/12.560740
|
|
|
“Study of a unique 16th century Antwerp majolica floor in the Rameyenhof castle's chapel by means of X-ray fluorescence and portable Raman analytical instrumentation”. Van de Voorde L, Vandevijvere M, Vekemans B, Van Pevenage J, Caen J, Vandenabeele P, van Espen P, Vincze L, Spectrochimica acta: part B : atomic spectroscopy 102, 28 (2014). http://doi.org/10.1016/J.SAB.2014.10.007
Abstract: The most unique and only known 16th century Antwerp majolica tile floor in Belgium is situated in a tower of the Rameyenhof castle (Gestel, Belgium). This exceptional work of art has recently been investigated in situ by using X-ray fluorescence (XRF) and Raman spectroscopy in order to study the material characteristics. This study reports on the result of the analyses based on the novel combination of non-destructive and portable instrumentation, including a handheld XRF spectrometer for obtaining elemental information and a mobile Raman spectrometer for retrieving structural and molecular information on the floor tiles in the Rameyenhof castle and on a second, similar medallion, which is stored in the Rubens House museum in Antwerp (Belgium). The investigated material, majolica, is a type of ceramic, which fascinated many people and potters throughout history by its beauty and colourful appearance. In this study the characteristic major/minor and trace element signature of 16th century Antwerp majolica is determined and the pigments used for the colourful paintings present on the floor are identified. Furthermore, based on the elemental fingerprint of the white glaze, and in particular on the presence of zinc in the tiles – an element that was not used for making 16th century majolica – valuable information about the originality of the chapel floor and the two central medallions is acquired. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1016/J.SAB.2014.10.007
|
|
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
|
|
“Modeling of photon scattering at high X-ray energies : experiment versus simulation”. Vincze L, Vekemans B, Janssens K, Adams F, Journal of analytical atomic spectrometry
T2 –, 15th International Congress on X-Ray Optics and Microanalysis (ICXOM), AUG 24-27, 1998, ANTWERP, BELGIUM 14, 529 (1999). http://doi.org/10.1039/A808040B
Abstract: The use of a detailed Monte Carlo simulation code for X-ray fluorescence spectrometers is demonstrated for calculating the outcome of X-ray scattering experiments in the incident energy range 40-80 keV. The code was validated by comparisons of experimental and simulated spectral distributions in the case of thick, homogeneous samples in which multiple photon scattering occurs with high probability. The experimental spectral distributions were collected at beamline BW5 of HASYLAB, Germany, where a highly energetic, monochromatic synchrotron beam is available. With respect to heterogeneous samples, the code was employed to evaluate the use of Rayleigh and Compton scatter signals for obtaining three dimensional information on the sample dark matrix composition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A808040B
|
|
|
“Copper stabilization by zeolite synthesis in polluted soils treated with coal fly ash”. Terzano R, Spagnuolo M, Medici L, Vekemans B, Vincze L, Janssens K, Ruggiero P, Environmental science and technology 39, 6280 (2005). http://doi.org/10.1021/ES050079D
Abstract: This study deals with the process of zeolite formation in an agricultural soil artificially polluted by high amounts of Cu (15 mg of Cu/g of soil dry weight) and treated with fused coal fly ash at 30 and 60 degrees C and how this process affects the mobility and availability of the metal. As a consequence of the treatment, the amount of dissolved Cu, and thus its mobility, was strongly reduced, and the percentage of the metal stabilized in the solid phase increased over time, reaching values of 30% at 30 degrees C and 40% at 60 degrees C. The physicochemical phenomena responsible for Cu stabilization in the solid phase have been evaluated by EDTA sequential extractions and synchrotron radiation based X-ray microanalytical techniques. These techniques were used for the visualization of the spatial distribution and the speciation of Cu in and/or on the neo-formed zeolite particles. In particular, micro XRF (X-ray fluorescence) tomography showed direct evidence that Cu can be entrapped as clusters inside the porous zeolitic structures while,mu-XANES (X-ray absorption near edge structure) spectroscopy determinations revealed Cu to be present mainly as Cu(II) hydroxide and Cu(II) oxide. The reported results could be useful as a basic knowledge for planning new technologies for the on site physicochemical stabilization of heavy metals in heavily polluted soils.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.198
Times cited: 39
DOI: 10.1021/ES050079D
|
|