Bogaerts A, Berthelot A, Heijkers S, Kozá,k T (2015) Computer modeling of a microwave discharge used for CO2 splitting. UCO Press, Cordoba, 41–50
Keywords: P2 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
Berthelot A, Kolev S, Bogaerts A (2015) Different pressure regimes of a surface-wave discharge in argon : a modelling investigation. UCO Press, Cordoba, 57–62
Keywords: P2 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Glow discharge optical spectroscopy and mass spectrometry”. Bogaerts A John Wiley & Sons, Chichester, page 1 (2016).
Abstract: Atomic Spectroscopy Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupole mass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (500–1500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (mostly Ar) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes, and the photons or ions created in this way can be detected with optical emission spectroscopy or mass spectrometry. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. In recent years, there is also increasing interest for using GD sources for liquid and gas analyses. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution and gaseous samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This article focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GD sources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with a variety of spectroscopic and spectrometric instruments for both quantitative and qualitative analyses.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Glow discharge optical spectroscopy and mass spectrometry”. Bogaerts A, (2016). http://doi.org/10.1002/9780470027318.a5107
Abstract: Atomic Spectroscopy Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupole mass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (500–1500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (mostly Ar) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes, and the photons or ions created in this way can be detected with optical emission spectroscopy or mass spectrometry. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. In recent years, there is also increasing interest for using GD sources for liquid and gas analyses. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution and gaseous samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This article focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GD sources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with a variety of spectroscopic and spectrometric instruments for both quantitative and qualitative analyses.
Keywords: A1 Journal article; PLASMANT
DOI: 10.1002/9780470027318.a5107
|
“Analysis and comparison of the co2 and co dielectric barrier discharge solid products”. Belov I, Paulussen S, Bogaerts A, Hakone Xv: International Symposium On High Pressure Low Temperature Plasma Chemistry: With Joint Cost Td1208 Workshop: Non-equilibrium Plasmas With Liquids For Water And Surface Treatment (2016)
Abstract: The CO and CO2 Dielectric Barrier Discharges (DBD) and their solid products were analyzed keeping similar energy input regimes. Gas chromatography analysis revealed the presence of CO2, CO and O-2 mixture in the exhaust of the CO2 DBD, while no O-2 was found when CO was used as a feed gas. It was shown that the C-2 Swan lines observed with optical emission spectroscopy were distinct in the CO plasma while they were not observed in the CO2 emission spectrum. Also the solid products of the plasmas exhibited remarkable differences. Nanoparticles with a diameter between10 and 300 nm, composed of Fe, O and C (Fe: O: C similar to 13: 50: 30) were produced by the CO2 DBD, while microscopic dendrite-like carbon structure (C: O similar to 73: 27) were formed in the CO plasma. The growth rate in the CO2 and CO DBDs was evaluated to be on the level of 0.15 mg/min and 15 mg/min, respectively. The difference of the CO and CO2 discharges and their products might be attributed to the oxygen content in the latter (6.4 mol.% O-2 in the exhaust) and subsequent etching of the carbonaceous film.
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Plasma based co2 conversion: a combined modeling and experimental study”. Bogaerts A, Snoeckx R, Berthelot A, Heijkers S, Wang W, Sun S, Van Laer K, Ramakers M, Michielsen I, Uytdenhouwen Y, Meynen V, Cool P, Hakone Xv: International Symposium On High Pressure Low Temperature Plasma Chemistry: With Joint Cost Td1208 Workshop: Non-equilibrium Plasmas With Liquids For Water And Surface Treatment (2016)
Abstract: In recent years there is increased interest in plasma-based CO2 conversion. Several plasma setups are being investigated for this purpose, but the most commonly used ones are a dielectric barrier discharge (DBD), a microwave (MW) plasma and a gliding arc (GA) reactor. In this proceedings paper, we will show results from our experiments in a (packed bed) DBD reactor and in a vortex-flow GA reactor, as well as from our model calculations for the detailed plasma chemistry in a DBD, MW and GA, for pure CO2 as well as mixtures of CO2 with N-2, CH4 and H2O.
Keywords: P1 Proceeding; Laboratory of adsorption and catalysis (LADCA); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Possible Mechanism of Glucose Uptake Enhanced by Cold Atmospheric Plasma: Atomic Scale Simulations”. Razzokov J, Yusupov M, Bogaerts A, Plasma 1 (2018). http://doi.org/10.3390/plasma1010011
Abstract: Cold atmospheric plasma (CAP) has shown its potential in biomedical applications, such as wound healing, cancer treatment and bacterial disinfection. Recent experiments have provided evidence that CAP can also enhance the intracellular uptake of glucose molecules which is important in diabetes therapy. In this respect, it is essential to understand the underlying mechanisms of intracellular glucose uptake induced by CAP, which is still unclear. Hence, in this study we try to elucidate the possible mechanism of glucose uptake by cells by performing computer simulations. Specifically, we study the transport of glucose molecules through native and oxidized membranes. Our simulation results show that the free energy barrier for the permeation of glucose molecules across the membrane decreases upon increasing the degree of oxidized lipids in the membrane. This indicates that the glucose permeation rate into cells increases when the CAP oxidation level in the cell membrane is increased.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.3390/plasma1010011
|
“Modeling for a Better Understanding of Plasma-Based CO2 Conversion”. Bogaerts A, Snoeckx R, Trenchev G, Wang W In: Britun N, Silva T (eds) Plasma Chemistry and Gas Conversion. IntechOpen, Rijeka (2018).
Abstract: This chapter discusses modeling efforts for plasma-based CO2 conversion, which are needed to obtain better insight in the underlying mechanisms, in order to improve this application. We will discuss two types of (complementary) modeling efforts that are most relevant, that is, (i) modeling of the detailed plasma chemistry by zero-dimensional (0D) chemical kinetic models and (ii) modeling of reactor design, by 2D or 3D fluid dynamics models. By showing some characteristic calculation results of both models, for CO2 splitting and in combination with a H-source, and for packed bed DBD and gliding arc plasma, we can illustrate the type of information they can provide.
Keywords: H1 Book Chapter; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
DOI: 10.5772/intechopen.80436
|
Ivanov V, Paunska T, Lazarova S, Bogaerts A, Kolev S (2023) Gliding arc/glow discharge for CO2 conversion: Comparing the performance of different discharge configurations. 102300
Abstract: We studied the use of low current (hundreds of milliamperes) gliding arc/glow discharges for CO2 dissociation, at atmospheric pressure, in three different configurations. All of these are based on the gliding arc design with flat diverging electrodes. The discharge is mainly in the normal glow regime with contracted positive column. The CO2 gas is injected from a nozzle, at the closest separation between the electrodes. A pair of quartz glasses is placed on both sides of the electrodes, so that the gas flow is restricted to the active plasma area, between the electrodes. For two of the tested configurations, an external magnetic field was applied, to create a magnetic force, both in the direction of the gas flow, and opposite to the gas flow. In the first case, the arc is accelerated, shortening the period between ignition and extinction, while in the second case, it is stabilized (magneticallystabilized). We studied two quantities, namely the CO2 conversion and the energy efficiency of the conversion. Generally, the CO2 conversion decreases with increasing flow rate and increases with power. The energy efficiency increases with the flow rate, for all configurations. The magnetically-stabilized configuration is more stable and efficient at low gas flow rates, but has poor performance at high flow rates, while the non-stabilized configurations exhibit good conversion for a larger range of flow rates, but they are generally more unstable and less efficient.
Keywords: A1 Journal Article;CO2 conversion; CO2 dissociation; Low current gliding arc; Magnetic stabilization; Magnetically stabilized discharge; Gliding glow discharge; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
Impact Factor: 7.7
DOI: 10.1016/j.jcou.2022.102300
|
“3D porous catalysts for plasma-catalytic dry reforming of methane : how does the pore size affect the plasma-catalytic performance?”.Wang J, Zhang K, Bogaerts A, Meynen V, Chemical engineering journal 464, 142574 (2023). http://doi.org/10.1016/J.CEJ.2023.142574
Abstract: The effect of pore size on plasma catalysis is crucial but still unclear. Studies have shown plasma cannot enter micropores and mesopores, so catalysts for traditional thermocatalysis may not fit plasma catalysis. Here, 3D porous Cu and CuO with different pore sizes were prepared using uniform silica particles (10–2000 nm) as templates, and compared in plasma-catalytic dry reforming. In most cases, the smaller the pore size, the higher the conversion of CH4 and CO2. Large pores reachable by more electrons did not improve the reaction efficiency. We attribute this to the small surface area and large crystallite size, as indicated by N2-sorption, mercury intrusion and XRD. While the smaller pores might not be reachable by electrons, due to the sheath formed in front of them, as predicted by modeling, they can still be reached by radicals formed in the plasma, and ions can even be attracted into these pores. An exception are the samples synthesized from 1 μm silica, which show better performance. We believe this is due to the electric field enhancement for pore sizes close to the Debye length. The performances of CuO and Cu with different pore sizes can provide references for future research on oxide supports and metal components of plasma catalysts.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 15.1
DOI: 10.1016/J.CEJ.2023.142574
|
“Atomic oxygen assisted CO2 conversion: A theoretical analysis”. Verheyen C, van ’t Veer K, Snyders R, Bogaerts A, Journal of CO2 utilization 67, 102347 (2023). http://doi.org/10.1016/j.jcou.2022.102347
Abstract: With climate change still a pressing issue, there is a great need for carbon capture, utilisation and storage (CCUS)
methods. We propose a novel concept where CO2 conversion is accomplished by O2 splitting followed by the
addition of O atoms to CO2. The latter is studied here by means of kinetic modelling. In the first instance, we
study various CO2/O ratios, and we observe an optimal CO2 conversion of around 30–40% for 50% O addition.
Gas temperature also has a large influence, with a minimum temperature of around 1000 K to a maximum of
2000 K for optimal conversion. In the second instance, we study various CO2/O/O2 ratios, due to O2 being a
starting gas. Also here we define optimal regions for CO2 conversion, which reach maximum conversion for a
CO2 fraction of 50% and an O/O2 ratio bigger than 1. Those can be expanded by heating on one hand, for low
atomic oxygen availability, and by quenching after reaction on the other hand, for cases where the temperatures
are too high. Our model predictions can serve as a guideline for experimental research in this domain.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 7.7
DOI: 10.1016/j.jcou.2022.102347
|
“Plasma-catalytic ammonia synthesis in a dielectric barrier discharge reactor: A combined experimental study and kinetic modeling”. Andersen Ja, Holm Mc, van 't Veer K, Christensen Jm, Østberg M, Bogaerts A, Jensen Ad, Chemical engineering journal 457, 141294 (2023). http://doi.org/10.1016/j.cej.2023.141294
Abstract: Plasma-catalytic ammonia synthesis in a dielectric barrier discharge reactor has emerged as a possible route for electrification of nitrogen fixation. In this study, we use a combination of experiments and a plasma kinetic model to investigate the ammonia synthesis from N2 and H2, both with and without a solid packing material in the plasma zone. The effect of plasma power, feed flow rate, N2:H2 feed ratio, gas residence time, temperature, and packing material (MgAl2O4 alone or impregnated with Co or Ru) on the ammonia synthesis rate were examined in the experiments. The kinetic model was employed to improve our understanding of the ammonia formation pathways and identify possible changes in these pathways when altering the N2:H2 feed ratio. A higher NH3 synthesis rate was achieved when increasing the feed flow rate, as well as when increasing the gas tem-perature from 100 to 200 ◦C when a packing material was present in the plasma. At the elevated temperature of 200 ◦C, an optimum in the NH3 synthesis rate was observed at an equimolar feed ratio (N2:H2 =1:1) for the plasma alone and MgAl2O4, while a N2-rich feed was favored for Ru/MgAl2O4 and Co/MgAl2O4. The optimum in the synthesis rate with the N2-rich feed, where high energy electrons are more likely to collide with N2, suggests that the rate-limiting step is the dissociation of N2 in the gas phase. This is supported by the kinetic model when packing material was used. However, for the plasma alone, the model found that the N2 dissociation is only rate limiting in H2-rich feeds, whereas the limited access to H in N2-rich feeds makes the hydrogenation of N species limiting.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 15.1
DOI: 10.1016/j.cej.2023.141294
|
“Post-plasma quenching to improve conversion and energy efficiency in a CO2 microwave plasma”. Mercer Er, Van Alphen S, van Deursen Cfam, Righart Twh, Bongers Wa, Snyders R, Bogaerts A, van de Sanden Mcm, Peeters Fjj, Fuel 334, 126734 (2023). http://doi.org/10.1016/j.fuel.2022.126734
Abstract: Transforming CO2 into value-added chemicals is crucial to realizing a carbon–neutral economy, and plasma-based conversion, a Power-2-X technology, offers a promising route to realizing an efficient and scalable process. This paper investigates the effects of post-plasma placement of a converging–diverging nozzle in a vortex-stabilized 2.45 GHz CO2 microwave plasma reactor to increase energy efficiency and conversion. The CDN leads to a 21 % relative increase in energy efficiency (31 %) and CO2 conversion (13 %) at high flow rates and near-atmospheric conditions. The most significant performance improvement was seen at low flow rates and sub-atmospheric pressure (300 mbar), where energy efficiency was 23 % and conversion was 28 %, a 71 % relative increase over conditions without the CDN. Using CFD simulations, we found that the CDN produces a change in the flow geometry, leading to a confined temperature profile at the height of the plasma, and forced extraction of CO to the post-CDN region.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 7.4
DOI: 10.1016/j.fuel.2022.126734
|
“Ammonia decomposition in a dielectric barrier discharge plasma: Insights from experiments and kinetic modeling”. Andersen Ja, van 't Veer K, Christensen Jm, Østberg M, Bogaerts A, Jensen Ad, Chemical engineering science 271, 118550 (2023). http://doi.org/10.1016/j.ces.2023.118550
Abstract: Utilizing ammonia as a storage medium for hydrogen is currently receiving increased attention. A possible method to retrieve the hydrogen is by plasma-catalytic decomposition. In this work, we combined an experimental study, using a dielectric barrier discharge plasma reactor, with a plasma kinetic model, to get insights into the decomposition mechanism. The experimental results revealed a similar effect on the ammonia conversion when changing the flow rate and power, where increasing the specific energy input (higher power or lower flow rate) gave an increased conversion. A conversion as high as 82 % was achieved at a specific energy input of 18 kJ/Nl. Furthermore, when changing the discharge volume from 31 to 10 cm3, a change in the plasma distribution factor from 0.2 to 0.1 was needed in the model to best describe the conversions of the experiments. This means that a smaller plasma volume caused a higher transfer of energy through micro-discharges (non-uniform plasma), which was found to promote the decomposition of ammonia. These results indicate that it is the collisions between NH3 and the high-energy electrons that initiate the decomposition. Moreover, the rate of ammonia destruction was found by the model to be in the order of 1022 molecules/(cm3 s) during the micro-discharges, which is 5 to 6 orders of magnitude higher than in the afterglows. A considerable re-formation of ammonia was found to take place in the afterglows, limiting the overall conversion. In addition, the model revealed that implementation of packing material in the plasma introduced high concentrations of surface-bound hydrogen atoms, which introduced an additional ammonia re-formation pathway through an Eley-Rideal reaction with gas phase NH2. Furthermore, a more uniform plasma is predicted in the presence of MgAl2O4, which leads to a lower average electron energy during micro-discharges and a lower conversion (37 %) at a comparable residence time for the plasma alone (51 %).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.7
DOI: 10.1016/j.ces.2023.118550
|
“Nitrogen Fixation by an Arc Plasma at Elevated Pressure to Increase the Energy Efficiency and Production Rate of NOx”. Tsonev I, O’Modhrain C, Bogaerts A, Gorbanev Y, ACS Sustainable Chemistry and Engineering 11, 1888 (2023). http://doi.org/10.1021/acssuschemeng.2c06357
Abstract: Plasma-based nitrogen fixation for fertilizer production is an attractive alternative to the fossil fuel-based industrial processes. However, many factors hinder its applicability, e.g., the commonly observed inverse correlation between energy consumption and production rates or the necessity to enhance the selectivity toward NO2, the desired product for a more facile formation of nitrate-based fertilizers. In this work, we investigated the use of a rotating gliding arc plasma for nitrogen fixation at elevated pressures (up to 3 barg), at different feed gas flow rates and composition. Our results demonstrate a dramatic increase in the amount of NOx produced as a function of increasing pressure, with a record-low EC of 1.8 MJ/(mol N) while yielding a high production rate of 69 g/h and a high selectivity (94%) of NO2. We ascribe this improvement to the enhanced thermal Zeldovich mechanism and an increased rate of NO oxidation compared to the back reaction of NO with atomic oxygen, due to the elevated pressure.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 8.4
DOI: 10.1021/acssuschemeng.2c06357
|
“Acquired non-thermal plasma resistance mediates a shift towards aerobic glycolysis and ferroptotic cell death in melanoma”. Lin A, Sahun M, Biscop E, Verswyvel H, De Waele J, De Backer J, Theys C, Cuypers B, Laukens K, Berghe WV, Smits E, Bogaerts A, Drug resistance updates 67, 100914 (2023). http://doi.org/10.1016/j.drup.2022.100914
Abstract: To gain insights into the underlying mechanisms of NTP therapy sensitivity and resistance, using the firstever
NTP-resistant cell line derived from sensitive melanoma cells (A375).
Methods: Melanoma cells were exposed to NTP and re-cultured for 12 consecutive weeks before evaluation
against the parental control cells. Whole transcriptome sequencing analysis was performed to identify differentially
expressed genes and enriched molecular pathways. Glucose uptake, extracellular lactate, media acidification,
and mitochondrial respiration was analyzed to determine metabolic changes. Cell death inhibitors were
used to assess the NTP-induced cell death mechanisms, and apoptosis and ferroptosis was further validated via
Annexin V, Caspase 3/7, and lipid peroxidation analysis.
Results: Cells continuously exposed to NTP became 10 times more resistant to NTP compared to the parental cell
line of the same passage, based on their half-maximal inhibitory concentration (IC50). Sequencing and metabolic
analysis indicated that NTP-resistant cells had a preference towards aerobic glycolysis, while cell death analysis
revealed that NTP-resistant cells exhibited less apoptosis but were more vulnerable to lipid peroxidation and
ferroptosis.
Conclusions: A preference towards aerobic glycolysis and ferroptotic cell death are key physiological changes in
NTP-resistance cells, which opens new avenues for further, in-depth research into other cancer types.
Keywords: A1 Journal article; Pharmacology. Therapy; ADReM Data Lab (ADReM); Center for Oncological Research (CORE); Proteinscience, proteomics and epigenetic signaling (PPES); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 24.3
DOI: 10.1016/j.drup.2022.100914
|
“Postplasma Catalytic Model for NO Production: Revealing the Underlying Mechanisms to Improve the Process Efficiency”. Eshtehardi HA, van 't Veer K, Delplancke M-P, Reniers F, Bogaerts A, ACS Sustainable Chemistry and Engineering 11, 1720 (2023). http://doi.org/10.1021/acssuschemeng.2c05665
Abstract: Plasma catalysis is emerging for plasma-assisted gas conversion processes. However, the underlying mechanisms of plasma catalysis are poorly understood. In this work, we present a 1D heterogeneous catalysis model with axial dispersion (i.e., accounting for back-mixing and molecular diffusion of fluid elements in the process stream in the axial direction), for plasma-catalytic NO production from N2/O2 mixtures. We investigate the concentration and reaction rates of each species formed as a function of time and position across the catalyst, in order to determine the underlying mechanisms. To obtain insights into how the performance of the process can be further improved, we also study how changes in the postplasma gas flow composition entering the catalyst bed and in the operation conditions of the catalytic stage affect the performance of NO production.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 8.4
DOI: 10.1021/acssuschemeng.2c05665
|
“Bioactive Nonthermal Biocompatible Plasma Enhances Migration on Human Gingival Fibroblasts”. Han I, Song IS, Choi SA, Lee T, Yusupov M, Shaw P, Bogaerts A, Choi EH, Ryu JJ, Advanced healthcare materials 12, 2200527 (2023). http://doi.org/10.1002/adhm.202200527
Abstract: This study hypothesizes that the application of low-dose nonthermal biocompatible dielectric barrier discharge plasma (DBD-NBP) to human gingival fibroblasts (HGFs) will inhibit colony formation but not cell death and induce matrix metalloproteinase (MMP) expression, extracellular matrix (ECM) degradation, and subsequent cell migration, which can result in enhanced wound healing. HGFs treated with plasma for 3 min migrate to each other across the gap faster than those in the control and 5-min treatment groups on days 1 and 3. The plasma-treated HGFs show significantly high expression levels of the cell cycle arrest-related p21 gene and enhanced MMP activity. Focal adhesion kinase (FAK) mediated attenuation of wound healing or actin cytoskeleton rearrangement, and plasma-mediated reversal of this attenuation support the migratory effect of DBD-NBP. Further, this work performs computer simulations to investigate the effect of oxidation on the stability and conformation of the catalytic kinase domain (KD) of FAK. It is found that the oxidation of highly reactive amino acids (AAs) Cys427, Met442, Cys559, Met571, Met617, and Met643 changes the conformation and increases the structural flexibility of the FAK protein and thus modulates its function and activity. Low-dose DBD-NBP-induces host cell cycle arrest, ECM breakdown, and subsequent migration, thus contributing to the enhanced wound healing process.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 10
DOI: 10.1002/adhm.202200527
|
“The adsorption and decomposition of SF6 over defective and hydroxylated MgO surfaces: A DFT study”. Cui Z, Hao Y, Jafarzadeh A, Li S, Bogaerts A, Li L, Surfaces and interfaces 36, 102602 (2023). http://doi.org/10.1016/j.surfin.2022.102602
Abstract: Plasma degradation is one of the most effective methods for the abatement of greenhouse gas sulfur hexafluoride
(SF6). To evaluate the potential of MgO as a catalyst in plasma degradation, we investigate the catalytic properties
of MgO on SF6 adsorption and activation by density functional theory (DFT) where the O-defective and
hydroxylated surfaces are considered as two typical plasma-generated surfaces. Our results show that perfect
MgO (001) and (111) surfaces cannot interact with SF6 and only physical adsorption happens. In case of Odefective
MgO surfaces, the O vacancy is the most stable adsorption site. SF6 undergoes a decomposition to SF5
and F over the O-defective MgO (001) surface and undergoes an elongation of the bottom S-F bond over the Odefective
(111) surface. Besides, SF6 shows a physically adsorption at the stepsite of the MgO (001) surface,
accompanied by small changes in its bond angle and length. Furthermore, SF6 is found to be physically and
chemically adsorbed over 0.5 and 1.0 ML (monolayer) H-covered O-terminated MgO (111) surfaces, respectively.
The SF6 molecule undergoes a self-decomposition on the 1.0 ML hydroxylated surface via a surface bonding
process. This study shows that defective and hydroxylated MgO surfaces have the surface capacities for SF6
activation, which shows that MgO has potential as packing material in SF6 waste treatment in packed-bed
plasmas.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.2
DOI: 10.1016/j.surfin.2022.102602
|
“Methane coupling in nanosecond pulsed plasmas: Correlation between temperature and pressure and effects on product selectivity”. Morais E, Delikonstantis E, Scapinello M, Smith G, Stefanidis GD, Bogaerts A, Chemical engineering journal 462, 142227 (2023). http://doi.org/10.1016/j.cej.2023.142227
Abstract: We present a zero-dimensional kinetic model to characterise specifically the gas-phase dynamics of methane
conversion in a nanosecond pulsed discharge (NPD) plasma reactor. The model includes a systematic approach to
capture the nanoscale power discharges and the rapid ensuing changes in electric field, gas and electron temperature,
as well as species densities. The effects of gas temperature and reactor pressure on gas conversion and
product selectivity are extensively investigated and validated against experimental work. We discuss the
important reaction pathways and provide an analysis of the dynamics of the heating and cooling mechanisms. H
radicals are found to be the most populous plasma species and they participate in hydrogenation and dehydrogenation
reactions, which are the dominant recombination reactions leading to C2H4 and C2H2 as main
products (depending on the pressure).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 15.1
DOI: 10.1016/j.cej.2023.142227
|
“Modelling post-plasma quenching nozzles for improving the performance of CO2 microwave plasmas”. Van Alphen S, Hecimovic A, Kiefer CK, Fantz U, Snyders R, Bogaerts A, Chemical engineering journal 462, 142217 (2023). http://doi.org/10.1016/j.cej.2023.142217
Abstract: Given the ecological problems associated to the CO2 emissions of fossil fuels, plasma technology has gained
interest for conversion of CO2 into value-added products. Microwave plasmas operating at atmospheric pressure
have proven to be especially interesting, due to the high gas temperatures inside the reactor (i.e. up to 6000 K)
allowing for efficient thermal dissociation of CO2 into CO and O2. However, the performance of these high
temperature plasmas is limited by recombination of CO back into CO2 once the gas cools down in the afterglow.
In this work, we computationally investigated several quenching nozzles, developed and experimentally tested
by Hecimovic et al., [1] for their ability to quickly cool the gas after the plasma, thereby quenching the CO
recombination reactions. Using a 3D computational fluid dynamics model and a quasi-1D chemical kinetics
model, we reveal that a reactor without nozzle lacks gas mixing between hot gas in the center and cold gas near
the reactor walls. Especially at low flow rates, where there is an inherent lack of convective cooling due to the
low gas flow velocity, the temperature in the afterglow remains high (between 2000 and 3000 K) for a relatively
long time (in the 0.1 s range). As shown by our quasi-1D chemical kinetics model, this results in a important loss
of CO due to recombination reactions. Attaching a nozzle in the effluent of the reactor induces fast gas quenching
right after the plasma. Indeed, it introduces (i) more convective cooling by forcing cool gas near the walls to mix
with hot gas in the center of the reactor, as well as (ii) more conductive cooling through the water-cooled walls of
the nozzle. Our model shows that gas quenching and the suppression of recombination reactions have more
impact at low flow rates, where recombination is the most limiting factor in the conversion process.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 15.1
DOI: 10.1016/j.cej.2023.142217
|
“Hybrid plasma-thermal system for methane conversion to ethylene and hydrogen”. Liu R, Hao Y, Wang T, Wang L, Bogaerts A, Guo H, Yi Y, Chemical engineering journal 463, 142442 (2023). http://doi.org/10.1016/j.cej.2023.142442
Abstract: By combining dielectric barrier discharge plasma and external heating, we exploit a two-stage hybrid plasmathermal
system (HPTS), i.e., a plasma stage followed by a thermal stage, for direct non-oxidative coupling of
CH4 to C2H4 and H2, yielding a CH4 conversion of ca. 17 %. In the two-stage HPTS, the plasma first converts CH4
into C2H6 and C3H8, which in the thermal stage leads to a high C2H4 selectivity of ca. 63 % by pyrolysis, with H2
selectivity of ca. 64 %.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 15.1
DOI: 10.1016/j.cej.2023.142442
|
“NH3and HNOxFormation and Loss in Nitrogen Fixation from Air with Water Vapor by Nonequilibrium Plasma”. Vervloessem E, Gromov M, De Geyter N, Bogaerts A, Gorbanev Y, Nikiforov A, ACS Sustainable Chemistry and Engineering 11, 4289 (2023). http://doi.org/10.1021/acssuschemeng.3c00208
Abstract: The current global energy crisis indicated that increasing our
insight into nonfossil fuel nitrogen fixation pathways for synthetic fertilizer
production is more crucial than ever. Nonequilibrium plasma is a good candidate
because it can use N2 or air as a N source and water directly as a H source, instead
of H2 or fossil fuel (CH4). In this work, we investigate NH3 gas phase formation
pathways from humid N2 and especially humid air up to 2.4 mol % H2O (100%
relative humidity at 20 °C) by optical emission spectroscopy and Fouriertransform
infrared spectroscopy. We demonstrate that the nitrogen fixation
capacity is increased when water vapor is added, as this enables HNO2 and NH3
production in both N2 and air. However, we identified a significant loss
mechanism for NH3 and HNO2 that occurs in systems where these species are
synthesized simultaneously; i.e., downstream from the plasma, HNO2 reacts with NH3 to form NH4NO2, which rapidly decomposes
into N2 and H2O. We also discuss approaches to prevent this loss mechanism, as it reduces the effective nitrogen fixation when not
properly addressed and therefore should be considered in future works aimed at optimizing plasma-based N2 fixation. In-line removal
of HNO2 or direct solvation in liquid are two proposed strategies to suppress this loss mechanism. Indeed, using liquid H2O is
beneficial for accumulation of the N2 fixation products. Finally, in humid air, we also produce NH4NO3, from the reaction of HNO3
with NH3, which is of direct interest for fertilizer application.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 8.4
DOI: 10.1021/acssuschemeng.3c00208
|
“Postplasma Catalytic Model for NO Production: Revealing the Underlying Mechanisms to Improve the Process Efficiency”. Eshtehardi HA, Van ‘t Veer K, Delplancke M-P, Reniers F, Bogaerts A, ACS Sustainable Chemistry and Engineering 11, 1720 (2023). http://doi.org/10.1021/acssuschemeng.2c05665
Abstract: Plasma catalysis is emerging for plasma-assisted gas conversion
processes. However, the underlying mechanisms of plasma catalysis are poorly
understood. In this work, we present a 1D heterogeneous catalysis model with axial
dispersion (i.e., accounting for back-mixing and molecular diffusion of fluid elements in
the process stream in the axial direction), for plasma-catalytic NO production from
N2/O2 mixtures. We investigate the concentration and reaction rates of each species
formed as a function of time and position across the catalyst, in order to determine the
underlying mechanisms. To obtain insights into how the performance of the process
can be further improved, we also study how changes in the postplasma gas flow
composition entering the catalyst bed and in the operation conditions of the catalytic
stage affect the performance of NO production.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 8.4
DOI: 10.1021/acssuschemeng.2c05665
|
“Postplasma Catalytic Model for NO Production: Revealing the Underlying Mechanisms to Improve the Process Efficiency”. Eshtehardi HA, Van ‘t Veer K, Delplancke M-P, Reniers F, Bogaerts A, ACS Sustainable Chemistry and Engineering 11, 1720 (2023). http://doi.org/10.1021/acssuschemeng.2c05665
Abstract: Plasma catalysis is emerging for plasma-assisted gas conversion
processes. However, the underlying mechanisms of plasma catalysis are poorly
understood. In this work, we present a 1D heterogeneous catalysis model with axial
dispersion (i.e., accounting for back-mixing and molecular diffusion of fluid elements in
the process stream in the axial direction), for plasma-catalytic NO production from
N2/O2 mixtures. We investigate the concentration and reaction rates of each species
formed as a function of time and position across the catalyst, in order to determine the
underlying mechanisms. To obtain insights into how the performance of the process
can be further improved, we also study how changes in the postplasma gas flow
composition entering the catalyst bed and in the operation conditions of the catalytic
stage affect the performance of NO production.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 8.4
DOI: 10.1021/acssuschemeng.2c05665
|
“Modelling post-plasma quenching nozzles for improving the performance of CO2 microwave plasmas”. Van Alphen S, Hecimovic A, Kiefer CK, Fantz U, Snyders R, Bogaerts A, Chemical engineering journal 462, 142217 (2023). http://doi.org/10.1016/j.cej.2023.142217
Abstract: Given the ecological problems associated to the CO2 emissions of fossil fuels, plasma technology has gained
interest for conversion of CO2 into value-added products. Microwave plasmas operating at atmospheric pressure
have proven to be especially interesting, due to the high gas temperatures inside the reactor (i.e. up to 6000 K)
allowing for efficient thermal dissociation of CO2 into CO and O2. However, the performance of these high
temperature plasmas is limited by recombination of CO back into CO2 once the gas cools down in the afterglow.
In this work, we computationally investigated several quenching nozzles, developed and experimentally tested
by Hecimovic et al., [1] for their ability to quickly cool the gas after the plasma, thereby quenching the CO
recombination reactions. Using a 3D computational fluid dynamics model and a quasi-1D chemical kinetics
model, we reveal that a reactor without nozzle lacks gas mixing between hot gas in the center and cold gas near
the reactor walls. Especially at low flow rates, where there is an inherent lack of convective cooling due to the
low gas flow velocity, the temperature in the afterglow remains high (between 2000 and 3000 K) for a relatively
long time (in the 0.1 s range). As shown by our quasi-1D chemical kinetics model, this results in a important loss
of CO due to recombination reactions. Attaching a nozzle in the effluent of the reactor induces fast gas quenching
right after the plasma. Indeed, it introduces (i) more convective cooling by forcing cool gas near the walls to mix
with hot gas in the center of the reactor, as well as (ii) more conductive cooling through the water-cooled walls of
the nozzle. Our model shows that gas quenching and the suppression of recombination reactions have more
impact at low flow rates, where recombination is the most limiting factor in the conversion process.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 15.1
DOI: 10.1016/j.cej.2023.142217
|
“Dry reforming in a dielectric barrier discharge reactor with non-uniform discharge gap : effects of metal rings on the discharge behavior and performance”. Wang J, Zhang K, Meynen V, Bogaerts A, Chemical engineering journal , 142953 (2023). http://doi.org/10.1016/J.CEJ.2023.142953
Abstract: The application of dielectric barrier discharge (DBD) plasma reactors is promising in various environmental and energy processes, but is limited by their low energy yield. In this study, we put a number of stainless steel rings over the inner electrode rod of the DBD reactor to change the local discharge gap and electric field, and we studied the dry reforming performance. At 50 W supplied power, the metal rings mostly have a negative impact on the performance, which we attribute to the non-uniform spatial distribution of the discharges caused by the rings. However, at 30 W supplied power, the energy yield is higher than at 50 W and the placement of the rings improves the performance of the reactor. More rings and with a larger cross-sectional diameter can further improve the performance. The reactor with 20 rings with a 3.2 mm cross-sectional diameter exhibits the best performance in this study. Compared to the reactor without rings, it increases the CO2 conversion from 7% to 16 %, the CH4 conversion from 12% to 23%, and the energy yield from 0.05 mmol/kJ supplied power to 0.1 mmol/kJ (0.19 mmol/kJ if calculated from the plasma power), respectively. The presence of the rings increases the local electric field, the displaced charge and the discharge fraction, and also makes the discharge more stable and with more uniform intensity. It also slightly improves the selectivity to syngas. The performance improvement observed by placing stainless steel rings in this study may also be applicable to other plasma-based processes.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 15.1
DOI: 10.1016/J.CEJ.2023.142953
|
“Inactivation of SARS-CoV-2 and other enveloped and non-enveloped viruses with non-thermal plasma for hospital disinfection”. Sahun M, Privat-Maldonado A, Lin A, De Roeck N, Van de Heyden L, Hillen M, Michiels J, Steenackers G, Smits E, Ariën KK, Jorens PG, Delputte P, Bogaerts A, ACS Sustainable Chemistry and Engineering , 1 (2023). http://doi.org/10.1021/ACSSUSCHEMENG.2C07622
Abstract: As recently highlighted by the SARS-CoV-2 pandemic, viruses have become an increasing burden for health, global economy, and environment. The control of transmission by contact with contaminated materials represents a major challenge, particularly in hospital environments. However, the current disinfection methods in hospital settings suffer from numerous drawbacks. As a result, several medical supplies that cannot be properly disinfected are not reused, leading to severe shortages and increasing amounts of waste, thus prompting the search for alternative solutions. In this work, we report that non-thermal plasma (NTP) can effectively inactivate SARS-CoV-2 from non-porous and porous materials commonly found in healthcare facilities. We demonstrated that 5 min treatment with a dielectric barrier discharge NTP can inactivate 100% of SARS-CoV-2 (Wuhan and Omicron strains) from plastic material. Using porcine respiratory coronavirus (surrogate for SARS-CoV-2) and coxsackievirus B3 (highly resistant non-enveloped virus), we tested the NTP virucidal activity on hospital materials and obtained complete inactivation after 5 and 10 min, respectively. We hypothesize that the produced reactive species and local acidification contribute to the overall virucidal effect of NTP. Our results demonstrate the potential of dielectric barrier discharge NTPs for the rapid, efficient, and low-cost disinfection of healthcare materials.
Keywords: A1 Journal article; Engineering sciences. Technology; Center for Oncological Research (CORE); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 8.4
DOI: 10.1021/ACSSUSCHEMENG.2C07622
|
“Challenges in unconventional catalysis”. Bogaerts A, Centi G, Hessel V, Rebrov E, Catalysis today 420, 114180 (2023). http://doi.org/10.1016/j.cattod.2023.114180
Abstract: Catalysis science and technology increased efforts recently to progress beyond conventional “thermal” catalysis and face the challenges of net-zero emissions and electrification of production. Nevertheless, a better gaps and opportunities analysis is necessary. This review analyses four emerging areas of unconventional or less- conventional catalysis which share the common aspect of using directly renewable energy sources: (i) plasma catalysis, (ii) catalysis for flow chemistry and process intensification, (iii) application of electromagnetic (EM) fields to modulate catalytic activity and (iv) nanoscale generation at the catalyst interface of a strong local EM by plasmonic effect. Plasma catalysis has demonstrated synergistic effects, where the outcome is higher than the sum of both processes alone. Still, the underlying mechanisms are complex, and synergy is not always obtained. There is a crucial need for a better understanding to (i) design catalysts tailored to the plasma environment, (ii) design plasma reactors with optimal transport of plasma species to the catalyst surface, and (iii) tune the plasma conditions so they work in optimal synergy with the catalyst. Microfluidic reactors (flow chemistry) is another emerging sector leading to the intensification of catalytic syntheses, particularly in organic chemistry. New unconventional catalysts must be designed to exploit in full the novel possibilities. With a focus on (a) continuous-flow photocatalysis, (b) electrochemical flow catalysis, (c) microwave flow catalysis and (d) ultra sound flow activation, a series of examples are discussed, with also indications on scale-up and process indus trialisation. The third area discussed regards the effect on catalytic performances of applying oriented EM fields spanning several orders of magnitude. Under well-defined conditions, gas breakdown and, in some cases, plasma formation generates activated gas phase species. The EM field-driven chemical conversion processes depend further on structured electric/magnetic catalysts, which shape the EM field in strength and direction. Different effects influencing chemical conversion have been reported, including reduced activation energy, surface charging, hot spot generation, and selective local heating. The last topic discussed is complementary to the third, focusing on the possibility of tuning the photo- and electro-catalytic properties by creating a strong localised electrical field with a plasmonic effect. The novel possibilities of hot carriers generated by the plasmonic effect are also discussed. This review thus aims to stimulate the reader to make new, creative catalysis to address the challenges of reaching a carbon-neutral world.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.3
DOI: 10.1016/j.cattod.2023.114180
|
“Phototoxicity and cell passage affect intracellular reactive oxygen species levels and sensitivity towards non-thermal plasma treatment in fluorescently-labeled cancer cells”. Verswyvel H, Deben C, Wouters A, Lardon F, Bogaerts A, Smits E, Lin A, Journal of physics: D: applied physics 56, 294001 (2023). http://doi.org/10.1088/1361-6463/accc3d
Abstract: Live-cell imaging with fluorescence microscopy is a powerful tool, especially in cancer research, widely-used for capturing dynamic cellular processes over time. However, light-induced toxicity (phototoxicity) can be incurred from this method, via disruption of intracellular redox balance and an overload of reactive oxygen species (ROS). This can introduce confounding effects in an experiment, especially in the context of evaluating and screening novel therapies. Here, we aimed to unravel whether phototoxicity can impact cellular homeostasis and response to non-thermal plasma (NTP), a therapeutic strategy which specifically targets the intracellular redox balance. We demonstrate that cells incorporated with a fluorescent reporter for live-cell imaging have increased sensitivity to NTP, when exposed to ambient light or fluorescence excitation, likely through altered proliferation rates and baseline intracellular ROS levels. These changes became even more pronounced the longer the cells stayed in culture. Therefore, our results have important implications for research implementing this analysis technique and are particularly important for designing experiments and evaluating redox-based therapies like NTP.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Center for Oncological Research (CORE)
Impact Factor: 3.4
DOI: 10.1088/1361-6463/accc3d
|