“Mitigation strategies for radiation damage in the analysis of ancient materials”. Bertrand L, Schoeeder S, Anglos D, Breese MBH, Janssens K, Moini M, Simon A, Trends in analytical chemistry 66, 128 (2015). http://doi.org/10.1016/J.TRAC.2014.10.005
Abstract: The study of materials in cultural heritage artifacts and micro-samples benefits from diagnostic techniques based on intense radiation sources, such as synchrotrons, ion-beam accelerators and lasers. While most of the corresponding techniques are classified as non-destructive, investigation with photons or charged particles entails a number of fundamental processes that may induce changes in materials. These changes depend on irradiation parameters, properties of materials and environmental factors. In some cases, radiation-induced damage may be detected by visual inspection. When it is not, irradiation may still lead to atomic and molecular changes resulting in immediate or delayed alteration and bias of future analyses. Here we review the effects of radiation reported on a variety of cultural heritage materials and describe the usual practice for assessing short-term and long-term effects. This review aims to raise awareness and encourage subsequent research activities to limit radiation side effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 35
DOI: 10.1016/J.TRAC.2014.10.005
|
“Recent trends in quantitative aspects of microscopic X-ray fluorescence analysis”. Janssens K, de Nolf W, van der Snickt G, Vincze L, Vekemans B, Terzano R, Brenker FE, Trends in analytical chemistry 29, 464 (2010). http://doi.org/10.1016/J.TRAC.2010.03.003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 48
DOI: 10.1016/J.TRAC.2010.03.003
|
“Analytical techniques for the detection of amphetamine-type substances in different matrices : a comprehensive review”. Drăgan A-M, Parrilla M, Feier B, Oprean R, Cristea C, De Wael K, Trac-Trends In Analytical Chemistry 145, 116447 (2021). http://doi.org/10.1016/J.TRAC.2021.116447
Abstract: This current review focuses on contributions to amphetamine-type substances (ATS) analysis. This type of synthetic illicit drugs has been increasingly present worldwide reaching 5% of the market on illicit drugs in 2019. The increment of their production in many clandestine laboratories and easy distribution among society are two of the main concerns towards the battle against synthetic drugs. Therefore, the first part of this review details the classification and mechanism of action of ATS in the human body. Second, the pharmacological and toxicological effects of ATS on human health are described to motivate the need of early detection of ATS. Subsequently, the most used laboratory-based and portable methods are presented and critically discussed along the review. Finally, a careful discussion on the advantages and disadvantages of portable techniques employed on the field are addressed as potential tools for on-site ATS detection by law enforcement officers.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 8.442
DOI: 10.1016/J.TRAC.2021.116447
|
“Mapping the gaps in chemical analysis for the characterisation of aptamer-target interactions”. Daems E, Moro G, Campos R, De Wael K, Trac-Trends In Analytical Chemistry 142, 116311 (2021). http://doi.org/10.1016/J.TRAC.2021.116311
Abstract: Aptamers are promising biorecognition elements with a wide applicability from therapeutics to bio-sensing. However, to successfully use these biomolecules, a complete characterisation of their bindingperformance in the presence of the target is crucial. Several multi-analytical approaches have been re-ported including techniques to describe kinetic and thermodynamic aspects of the aptamer-targetinteraction, and techniques which allow an in-depth understanding of the aptamer-target structures.Recent literature shows the need of a critical data interpretation, a combination of characterisationtechniques and suggests the key role of the characterisation protocol design. Indeed, thefinal applicationof the aptamer should be considered before choosing the characterisation method. All the limitations andcapabilities of the analytical tools in use for aptamer characterisation should be taken into account. Here,we present a critical overview of the current methods and multi-analytical approaches to study aptamer-target binding, aiming to provide researchers with guidelines for the design of characterisation protocols.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
DOI: 10.1016/J.TRAC.2021.116311
|
“Colloquium Spectroscopicum Internationale 34, Antwerp, Belgium, 4-9 September 2005: preface”. Janssens K, Bogaerts A, van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 70, 907 (2006). http://doi.org/10.1016/j.talanta.2006.05.044
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
DOI: 10.1016/j.talanta.2006.05.044
|
“Fast steel-cleanness characterization by means of laser-assisted plasma spectrometric methods”. Mueller G, Stahnke F, Bleiner D, Talanta : the international journal of pure and applied analytical chemistry
T2 –, 34th Colloquium Spectroscopicum Internationale, SEP 04-09, 2005, Univ Antwerp, Antwerp, BELGIUM (2006). http://doi.org/10.1016/J.TALANTA.2006.05.047
Abstract: Laser-assisted plasma spectrometry is a palette of analytical techniques (L-OES, LA-ICP-MS) capable of fast spatially-resolved elemental analysis in the micrometer range. For fast estimation of the occurrence in steel samples of non-metallic inclusions, which degrade the material's technical properties, simultaneous OES detection and sequential ICP-MS detection were compared. Histograms were obtained for the intensity distribution of the acquired signals (laser pulse statistics). The skewness coefficient of the histograms for Al (indicator of non-metallic inclusions) was found to be clearly dependent on the fraction of non-metallic inclusions in the case of scanning L-OES. For LA-ICP-MS less clear dependence was observed, which was influenced by the acquisition characteristics. In fact, less measurement throughput limited for LA-ICP-MS the counting statistics to an extent that overrides the benefit of higher detection power as compared to L-OES. (c) 2006 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
Times cited: 12
DOI: 10.1016/J.TALANTA.2006.05.047
|
“FIB, TEM and LA-ICPMS investigations on melt inclusions in Martian meteorites –, Analytical capabilities and geochemical insights”. Bleiner D, Macri M, Gasser P, Sautter V, Maras A, Talanta : the international journal of pure and applied analytical chemistry (2006). http://doi.org/10.1016/J.TALANTA.2005.08.022
Abstract: In order to obtain full information coverage on melt inclusions in Martian meteorites (subgroup nakhlites) complementary micro-analytical techniques were used, i.e. focused ion beam, transmission electron microscopy and laser ablation. Using focused ion beam several lamellae for transmission electron microscopy were prepared and secondary electron images of cross-sections could be acquired. Laser ablation-inductively coupled plasma mass spectrometry analyses were performed on selected inclusions to obtain mass-oriented bulk composition of inclusions at depth. The differences in composition between melt inclusions in olivine and augite crystals would suggest a xenocrystic origin for olivine. Furthermore, electron diffraction patterns clearly indicated that the SiO2-rich phase in inclusions from augite in meteorites from Northwest Africa site is re-crystallized, whereas it is still vitreous in the inclusions from Nakhla sampling site. Therefore, different post-entrapment evolutions were active for the two nakhlite meteorite sets, the Nakhla and the NWA817 set. Melt inclusions in Nakhla olivine presented alteration veins, which were presumably produced before their landing on Earth. If this is the case, this would indicate a alteration stage already on Mars with all the consequence in terms of climate history. Melt inclusions in Nakhla augite resulted unaffected by any alteration or modification following the entrapment, and therefore represent the best candidate to indicate the pristine magma composition. (c) 2005 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
Times cited: 9
DOI: 10.1016/J.TALANTA.2005.08.022
|
“An adhesive conducting electrode material based on commercial mesoporous titanium dioxide as a support for Horseradish peroxidase for bioelectrochemical applications”. Rahemi V, Trashin S, Meynen V, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 146, 689 (2016). http://doi.org/10.1016/J.TALANTA.2015.06.041
Abstract: An adhesive conducting electrode material containing of graphite, biocompatible ion exchange polymer nafion® and commercial mesoporous TiO2 impregnated with horseradish peroxidase (HRP) is prepared and characterized by amperometric, UVvis and N2 sorption methods. The factors influencing the performance of the resulting biosensor are studied in detail. The optimal electrode material consists of 45% graphite, 50% impregnated HRPTiO2 and 5% nafion®. The optimum conditions for H2O2 reduction are an applied potential of 0.3 V and 0.1 mM hydroquinone. Sensitivity and limit of detection in the optimum conditions are 1 A M−1 cm−2 and 1 µM correspondingly. The N2 sorption results show that the pore volume of TiO2 decreases sharply upon adsorption of HRP. The preparation process of the proposed enzyme electrode is straightforward and potentially can be used for preparation of carbon paste electrodes for bioelectrochemical detections.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 7
DOI: 10.1016/J.TALANTA.2015.06.041
|
“Chemical boundary conditions for the classification of aerosol particles using computer controlled electron probe microanalysis”. Anaf W, Horemans B, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 101, 420 (2012). http://doi.org/10.1016/J.TALANTA.2012.09.051
Abstract: A method for the classification of individual aerosol particles using computer controlled electron probe microanalysis is presented. It is based on chemical boundary conditions (CBC) and enables quick and easy processing of a large set of elemental concentration data (mass%), derived from the X-ray spectra of individual particles. The particles are first classified into five major classes (sea salt related, secondary inorganic, minerals, iron-rich and carbonaceous), after which advanced data mining can be performed by examining the elemental composition of particles within each class into more detail (e.g., by ternary diagrams). The CBC method is validated and evaluated by comparing its results with the output obtained with hierarchical cluster analysis (HCA) for well-known standard particles as well as real aerosol particles collected with a cascade impactor. The CBC method gives reliable results and has a major advantage compared to HCA. CBC is based on boundary conditions that are derived from chemical logical thinking and does not require a translation of a mathematical algorithm output as does HCA. Therefore, the CBC method is more objective and enables comparison between samples without intermediate steps.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 3
DOI: 10.1016/J.TALANTA.2012.09.051
|
“Optimization of the ion chromatographic quantification of airborne fluoride, acetate and formate in the Metropolitan Museum of Art, New York”. Kontozova-Deutsch V, Deutsch F, Bencs L, Krata A, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 86, 372 (2011). http://doi.org/10.1016/J.TALANTA.2011.09.030
Abstract: Ion chromatographic (IC) methods have been compared in order to achieve an optimal separation of fluoride, acetate and formate under various elution conditions on two formerly introduced analytical columns (i and ii) and a novel one (iii): (i) an IonPac AS14 (250 mm × 4 mm I.D.), (ii) Allsep A-2 (150 mm × 4.6 mm I.D.), and (iii) an IC SI-50 4E (250 mm (length) × 4 mm (internal diameter – I.D.)). The IC conditions for the separation of the anions concerned were optimized on the IC SI-50 4E column. A near baseline separation of these anions was attained on the IonPac AS14, whereas the peaks of fluoride and acetate could not be resolved on the Allsep A-2. A baseline separation for the three anions was achieved on the IC SI-50 4E column, when applying an eluent mixture of 3.2 mmol/L Na2CO3 and 1.0 mmol/L NaHCO3 with a flow rate of 1.0 mL/min. The highest precision of 1.7, 3.0 and 2.8% and the best limits of detection (LODs) of 0.014, 0.22 and 0.17 mg/L for fluoride, acetate and formate, respectively, were obtained with the IC SI-50 4E column. Hence, this column was applied for the determination of the acetic and formic acid contents of air samples taken by means of passive gaseous sampling at the Metropolitan Museum of Art in New York, USA. Atmospheric concentrations of acetic and formic acid up to 1050 and 450 μg/m3, respectively, were found in non-aerated showcases of the museum. In galleries and outdoors, rather low levels of acetic and formic acid were detected with average concentrations of 50 and 10 μg/m3, respectively. The LOD data of acetate and formate on the IC SI-50 4E column correspond to around 0.5 μg/m3 for both acetic and formic acid in air samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 19
DOI: 10.1016/J.TALANTA.2011.09.030
|
“Polymer platforms for selective detection of cocaine in street samples adulterated with levamisole”. Florea A, Cowen T, Piletsky S, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 186, 362 (2018). http://doi.org/10.1016/J.TALANTA.2018.04.061
Abstract: Accurate drug detection is of utmost importance for fighting against drug abuse. With a high number of cutting agents and adulterants being added to cut or mask drugs in street powders the number of false results is increasing. We demonstrate for the first time the usefulness of employing polymers readily synthesized by electrodeposition to selectively detect cocaine in the presence of the commonly used adulterant levamisole. The polymers were selected by computational modelling to exhibit high binding affinity towards cocaine and deposited directly on the surface of graphene-modified electrodes via electropolymerization. The resulting platforms allowed a distinct electrochemical signal for cocaine, which is otherwise suppressed by levamisole. Square wave voltammetry was used to quantify cocaine alone and in the presence of levamisole. The usefulness of the platforms was demonstrated in the screening of real street samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 9
DOI: 10.1016/J.TALANTA.2018.04.061
|
“Stable carbon isotopic ratio measurement of polycyclic aromatic hydrocarbons as a tool for source identification and apportionment : a review of analytical methodologies”. Buczyńska AJ, Geypens B, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 105, 435 (2013). http://doi.org/10.1016/J.TALANTA.2012.10.075
Abstract: The measurement of the ratio of stable isotopes of carbon (13C/12C expressed as a δ13C) in the individual components of a sample may be used as a means to identify the origin of these components. This article reviews the approaches and reports on the successes and failures of source identification and apportionment of Polycyclic Aromatic Hydrocarbons (PAHs) with the use of compound-specific isotope analysis (CSIA). One of the conditions for a precise and accurate analysis of isotope ratios with the use of GC-C-IRMS is the need for well separated peaks, with no co-elutions, and reduced unresolved complex mixture (UCM). Additionally, special care needs to be taken for an investigation of possible isotope fractionation effects introduced during the analytical treatment of samples. With the above-mentioned problems in mind, this review discusses in detail and compares current laboratory methodologies, mainly in the extraction and subsequent clean-up techniques used for environmental samples (air particulate matter, soil and sediments). Sampling strategies, the use of isotopic internal standards and the ranges for precision and accuracy are also reported and discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 19
DOI: 10.1016/J.TALANTA.2012.10.075
|
“Electrodeposition of gold nanoparticles on boron doped diamond electrodes for the enhanced reduction of small organic molecules”. Bottari F, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 801, 521 (2017). http://doi.org/10.1016/J.JELECHEM.2017.07.053
Abstract: The performance of gold nanoparticles electrodeposited on boron doped diamond (BDD) electrodes was investigated in respect to the reduction of chloramphenicol (CAP), an antibiotic of the phenicols family. The chosen deposition protocol, three nucleation-growing pulses, shows a remarkable surface coverage, with an even distribution of average-sized gold particles (~ 50 nm), and it was proven capable of generating a three-fold increase in the CAP reduction current. A calibration plot for CAP detection was obtained in the micromolar range (535 μM) with good correlation coefficient (0.9959) and an improved sensitivity of 0.053 μA μM− 1 mm− 2 compared to the electrochemistry of CAP at a bare BDD electrode.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.012
Times cited: 4
DOI: 10.1016/J.JELECHEM.2017.07.053
|
“Electrochemical identification of hazardous phenols and their complex mixtures in real samples using unmodified screen-printed electrodes”. Barich H, Cánovas R, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 904, 115878 (2022). http://doi.org/10.1016/J.JELECHEM.2021.115878
Abstract: The electrochemical behavior of some of the most relevant endocrine-disrupting phenols using unmodified carbon screen-printed electrodes (SPEs) is described for the first time. Experiments were made to assess the electrochemical behavior of phenol (PHOH), pentachlorophenol (PCP), 4-tert octylphenol (OP) and bisphenol A (BPA) and their determination in the most favorable conditions, using voltammetric methods such as cyclic voltammetry (CV), linear sweep voltammetry (LSV) and square wave voltammetry (SWV) in Britton Robinson (BR) buffer. Further, the usefulness of the electrochemical approach was validated with real samples from a local river and was compared to commercial phenols test kit, which is commonly used for on-site screening in industrial streams and wastewaters. Finally, the approach was compared with a lab-bench standard method using real samples, i.e., high-performance liquid chromatography with a photodiode array detector (HPLC-DAD).
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.5
DOI: 10.1016/J.JELECHEM.2021.115878
|
“Voltammetric sensing using an array of modified SPCE coupled with machine learning strategies for the improved identification of opioids in presence of cutting agents”. Ortiz-Aguayo D, De Wael K, del Valle M, Journal Of Electroanalytical Chemistry 902, 115770 (2021). http://doi.org/10.1016/J.JELECHEM.2021.115770
Abstract: This work reports the use of modified screen-printed carbon electrodes (SPCEs) for the identification of three drugs of abuse and two habitual cutting agents, caffeine and paracetamol, combining voltammetric sensing and chemometrics. In order to achieve this goal, codeine, heroin and morphine were subjected to Square Wave Voltammetry (SWV) at pH 7, in order to elucidate their electrochemical fingerprints. The optimized SPCEs electrode array, which have a differentiated response for the three oxidizable compounds, was derived from Carbon, Prussian blue, Cobalt (II) phthalocyanine, Copper (II) oxide, Polypyrrole and Palladium nanoparticles ink-modified carbon electrodes. Finally, Principal Component Analysis (PCA) coupled with Silhouette parameter assessment was used to select the most suitable combination of sensors for identification of drugs of abuse in presence of cutting agents.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 3.012
DOI: 10.1016/J.JELECHEM.2021.115770
|
“Concentration profiles of metal contaminants in fluvial sediments of a rural-urban drainage basin in Tanzania”. Hellar-Kihampa H, Potgieter-Vermaak S, De Wael K, Lugwisha E, van Espen P, Van Grieken R, International journal of environmental analytical chemistry 94, 77 (2014). http://doi.org/10.1080/03067319.2013.791976
Abstract: This study investigated concentration profiles of trace, rare earth and platinum group metals in fluvial sediments from the Pangani river basin (43,650 km2), one of the largest river basins in Tanzania, to assess its environmental quality. Sediment samples were collected in two distinct seasons from 12 representative sites of diverse land-use practices and characterised by ICP-MS after optimised microwave digestion. Ecological risks were assessed by evaluation of pollution index and comparison with legislated sediment quality guidelines (SQG). The results revealed contamination by some trace metals (e.g. Pb, V, Cu, Cr, Ni, Cd, As, Co, Mn and Zn) in concentrations ranging from 0.7 to 2940 mg kg−1, and four rare earth elements (Y, Ce, Nd, Yb) in concentrations ranging from 0.9 (Yb) to 500 mg kg−1 dry weight (Ce), which significantly exceeded the estimated background values at some stations. Palladium was the only platinum group element that was detected in quantifiable concentrations (0.33.5 mg kg−1). Concentrations of some trace metals exceeded the SQGs at some localised areas. Principal component analysis and multivariate correlations indicated geochemical characteristics of the area as the major control of metal concentrations and spatial variability. Organic matter and clay contents also played a significant role in metal distributions. Assessment of land-use practices upstream of the sampling locations was used to trace potential anthropogenic sources of metal enrichments, where highest levels were found in areas close to urban centres and agricultural activities. The study provides baseline data for future monitoring programs, and highlights the need for more comprehensive analysis involving a wider spatio-temporal scale and ecotoxicological risk assessment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.208
Times cited: 5
DOI: 10.1080/03067319.2013.791976
|
“Design and development of a new program for data processing of mass spectra acquired by means of a high-resolution double-focusing glow-discharge mass spectrometer”. Robben J, Dufour D, Gijbels R, Fresenius' journal of analytical chemistry 370, 663 (2001). http://doi.org/10.1007/s002160100881
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 2
DOI: 10.1007/s002160100881
|
“Modeling of the sputtering process of cubic silver halide microcrystals and its relevance in depth profiling by secondary ion-mass spectrometry (SIMS)”. Lenaerts J, Verlinden G, Ignatova VA, van Vaeck L, Gijbels R, Geuens I, Fresenius' journal of analytical chemistry 370, 654 (2001). http://doi.org/10.1007/s002160100880
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 3
DOI: 10.1007/s002160100880
|
“New developments and applications in GDMS”. Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 364, 367 (1999). http://doi.org/10.1007/s002160051352
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 17
DOI: 10.1007/s002160051352
|
“Recent trends in solids mass spectrometry: GDMS and other methods”. Gijbels R, Bogaerts A, Fresenius' journal of analytical chemistry 359, 326 (1997). http://doi.org/10.1007/s002160050581
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 5
DOI: 10.1007/s002160050581
|
“Three-dimensional modeling of a direct current glow discharge in argon: is it better than one-dimensional modeling?”.Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 359, 331 (1997). http://doi.org/10.1007/s002160050582
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 9
DOI: 10.1007/s002160050582
|
“The use of synchrotron radiation for the characterization of artists' pigments and paintings”. Janssens K, Alfeld M, van der Snickt G, de Nolf W, Vanmeert F, Radepont M, Monico L, et al, Annual review of analytical chemistry 6, 399 (2013). http://doi.org/10.1146/ANNUREV-ANCHEM-062012-092702
Abstract: We review methods and recent studies in which macroscopic to (sub)microscopic X-ray beams were used for nondestructive analysis and characterization of pigments, paint microsamples, and/or entire paintings. We discuss the use of portable laboratory- and synchrotron-based instrumentation and describe several variants of X-ray fluorescence (XRF) analysis used for elemental analysis and imaging and combined with X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Macroscopic and microscopic (μ-)XRF variants of this method are suitable for visualizing the elemental distribution of key elements in paint multilayers. Technical innovations such as multielement, large-area XRF detectors have enabled such developments. The use of methods limited to elemental analysis or imaging usually is not sufficient to elucidate the chemical transformations that take place during natural pigment alteration processes. However, synchrotron-based combinations of μ-XRF, μ-XAS, and μ-XRD are suitable for such studies.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.435
Times cited: 46
DOI: 10.1146/ANNUREV-ANCHEM-062012-092702
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 85, 670 (2013). http://doi.org/10.1021/ac3031459
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 29
DOI: 10.1021/ac3031459
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 80, 4317 (2008). http://doi.org/10.1021/ac8006297
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 53
DOI: 10.1021/ac8006297
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 78, 3917 (2006). http://doi.org/10.1021/ac060597m
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 112
DOI: 10.1021/ac060597m
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 76, 3313 (2004). http://doi.org/10.1021/ac040052x
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 32
DOI: 10.1021/ac040052x
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 74, 2691 (2002). http://doi.org/10.1021/ac020190r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 18
DOI: 10.1021/ac020190r
|
“Atomic spectroscopy: a review”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 82, 4653 (2010). http://doi.org/10.1021/ac1010469
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 65
DOI: 10.1021/ac1010469
|
“Automated particle analysis of populations of silver halide microcrystals by electron probe microanalysis under cryogenic conditions”. Gregory CL, Nullens HA, Gijbels RH, van Espen PJ, Geuens I, de Keyzer R, Analytical chemistry 70, 2551 (1998). http://doi.org/10.1021/ac9710644
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 12
DOI: 10.1021/ac9710644
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of spectromicroscopic methods : 3 : synthesis, characterization, and detection of different crystal forms of the chrome yellow pigment”. Monico L, Janssens K, Miliani C, Brunetti BG, Vagnini M, Vanmeert F, Falkenberg G, Abakumov A, Lu Y, Tian H, Verbeeck J, Radepont M, Cotte M, Hendriks E, Geldof M, van der Loeff L, Salvant J, Menu M;, Analytical chemistry 85, 860 (2013). http://doi.org/10.1021/ac302158b
Abstract: The painter, Vincent van Gogh, and some of his contemporaries frequently made use of the pigment chrome yellow that is known to show a tendency toward darkening. This pigment may correspond to various chemical compounds such as PbCrO4 and PbCr1-xSxO4, that may each be present in various crystallographic forms with different tendencies toward degradation. Investigations by X-ray diffraction (XRD), mid-Fourier Transform infrared (FTIR), and Raman instruments (benchtop and portable) and synchrotron radiation-based micro-XRD and X-ray absorption near edge structure spectroscopy performed on oil-paint models, prepared with in-house synthesized PbCrO4 and PbCr1-xSxO4, permitted us to characterize the spectroscopic features of the various forms. On the basis of these results, an extended study has been carried out on historic paint tubes and on embedded paint microsamples taken from yellow-orange/pale yellow areas of 12 Van Gogh paintings, demonstrating that Van Gogh effectively made use of different chrome yellow types. This conclusion was also confirmed by in situ mid-FTIR investigations on Van Goghs Portrait of Gauguin (Van Gogh Museum, Amsterdam).
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 79
DOI: 10.1021/ac302158b
|