|
“Enamels in stained glass windows: preparation, chemical composition, microstructure and causes of deterioration”. Schalm O, van der Linden V, Frederickx P, Luyten S, van der Snickt G, Caen J, Schryvers D, Janssens K, Cornelis E, van Dyck D, Schreiner M, Spectrochimica acta: part B : atomic spectroscopy 64, 812 (2009). http://doi.org/10.1016/j.sab.2009.06.005
Abstract: Stained glass windows incorporating dark blue and purple enamel paint layers are in some cases subject to severe degradation while others from the same period survived the ravages of time. A series of dark blue, greenblue and purple enamel glass paints from the same region (Northwestern Europe) and from the same period (16early 20th centuries) has been studied by means of a combination of microscopic X-ray fluorescence analysis, electron probe micro analysis and transmission electron microscopy with the aim of better understanding the causes of the degradation. The chemical composition of the enamels diverges from the average chemical composition of window glass. Some of the compositions appear to be unstable, for example those with a high concentration of K2O and a low content of CaO and PbO. In other cases, the deterioration of the paint layers was caused by the less than optimal vitrification of the enamel during the firing process. Recipes and chemical compositions indicate that glassmakers of the 1617th century had full control over the color of the enamel glass paints they made. They mainly used three types of coloring agents, based on Co (dark blue), Mn (purple) and Cu (light-blue or greenblue) as coloring elements. Bluepurple enamel paints were obtained by mixing two different coloring agents. The coloring agent for redpurple enamel, introduced during the 19th century, was colloidal gold embedded in grains of lead glass.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
Impact Factor: 3.241
Times cited: 28
DOI: 10.1016/j.sab.2009.06.005
|
|
|
“Change in silica sources in Roman and post Roman glass”. Aerts A, Janssens K, Velde B, Dijkman W, Spectrochimica acta: part B : atomic spectroscopy 58, 659 (2003). http://doi.org/10.1016/S0584-8547(02)00287-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(02)00287-2
|
|
|
“Characterization of the main causes of deterioration of grisaille paint layers in 19th C. stained-glass windows by J.-B. Capronnier”. Schalm O, Janssens K, Caen J, Spectrochimica acta: part B : atomic spectroscopy 58, 589 (2003). http://doi.org/10.1016/S0584-8547(02)00282-3
Abstract: Twenty-seven glass fragments containing dark coloured grisaille paint layers of different qualities were collected from ten windows of the cathedral St. Michael & St. Gudule in Brussels (Belgium). The windows were made by J.-B. Capronnier (18141891) and cover the period between 1843 and 1878. The samples were cross-sectioned and examined in an electron microscope. Grisaille paint layers are not homogeneous and therefore, it is not meaningful to characterize them in terms of their average composition. Instead, parameters such as granularity, the number of residual gas bubbles per running millimetre of paint, the type of pigments, and the thickness of the paint layer were used to characterize them. The microscopic morphology allows a classification of the grisaille paint layers in four groups, every group associated with a quality level. Moreover, the main causes of the accelerated degradation of some of these paint layers could be explained. The classification made it possible to distinguish two periods in the work of Capronnier: (1) the early period (18431848) is characterized by the presence of either single granular paint layers or of double-layered systems consisting of a granular paint layer on top of a well-melted paint layer. The granular grisaille paint layers tend to pulverize; (2) the later period (18481878) is characterized by the presence of only well-vitrified paint layers. No sign of deterioration was found on the well-vitrified paint layers.
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(02)00282-3
|
|
|
“Composition of 12-18th century window glass in Belgium : non-figurative windows in secular buildings and stained-glass windows in religious buildings”. Schalm O, Janssens K, Wouters H, Caluwé, D, Spectrochimica acta: part B : atomic spectroscopy
T2 –, 18th International Congress on X-Ray Optics and Microanalysis, September 25-30, 2005, National Institute of Nuclear Physics, Frascati, Italy 62, 663 (2007). http://doi.org/10.1016/J.SAB.2007.03.006
Abstract: A set of ca. 500 window glass fragments originating from different historical sites in Belgium and covering the period 12(th)- 18(th) century was analyzed by rneans of electron probe microanalysis. Most samples are archaeological finds deriving from non-figurative windows in secular buildings. However. the analyzed set also contains glass sampled from still existing non-figurative windows in secular buildings and stained-glass windows in religious buildings. A sudden compositional change at the end of the 14(th) century can be noticed among the series of glass compositions that were obtained. These changes could be related to the use of different glassmaker recipes and to the introduction of new raw materials for glass making. (c) 2007 Elsevier B.V All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 50
DOI: 10.1016/J.SAB.2007.03.006
|
|
|
“A flexible and accurate quantification algorithm for EPXMA based on thin-film element yields”. Schalm O, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 58, 669 (2003). http://doi.org/10.1016/S0584-8547(02)00290-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(02)00290-2
|
|
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 1: theory”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 75 (2000). http://doi.org/10.1016/S0584-8547(99)00172-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00172-X
|
|
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 2: application”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 1039 (2000). http://doi.org/10.1016/S0584-8547(00)00220-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00220-2
|
|
|
“Localised and non-destructive analysis of metallic artefacts from ancient Egypt by means of a compact μ-XRF instrument”. Vittiglio G, Janssens K, Adams F, Oost A, Spectrochimica acta: part B : atomic spectroscopy 54, 1697 (1999). http://doi.org/10.1016/S0584-8547(99)00100-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00100-7
|
|
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
|
|
“mu-X-ray fluorescence and mu-X-ray diffraction investigations of sediment from the Ruprechtov nuclear waste disposal natural analog site”. Denecke MA, de Nolf W, Janssens K, Brendebach B, Falkenberg G, Noseck U, Rothkirch A, Spectrochimica acta: part B : atomic spectroscopy 63, 484 (2008). http://doi.org/10.1016/J.SAB.2008.01.001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2008.01.001
|
|
|
“Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies”. de Nolf W, Jaroszewicz J, Terzano R, Lind OC, Salbu B, Vekemans B, Janssens K, Falkenberg G, Spectrochimica acta: part B : atomic spectroscopy 64, 775 (2009). http://doi.org/10.1016/J.SAB.2009.06.003
Abstract: The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.30.5° are obtained at the bending magnet source when a pink beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.10.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2009.06.003
|
|
|
“Spatially resolved micro-X-ray fluorescence and micro-X-ray absorption fine structure study of a fractured granite bore core following a radiotracer experiment”. Denecke MA, Brendebach B, de Nolf W, Falkenberg G, Janssens K, Simon R, Spectrochimica acta: part B : atomic spectroscopy 64, 791 (2009). http://doi.org/10.1016/J.SAB.2009.05.025
Abstract: Spatially resolved X-ray absorption and fluorescence investigation with a micrometer-scale resolution on actinide-containing samples provide information necessary for safety assessment of nuclear waste disposal. In this paper one example of such an experiment is presented. This example entails neptunium speciation in a fractured granite bore core from the Swedish Äspö Hard Rock Laboratory following a radiotracer experiment using µ-XAFS and µ-XRF. In order to probe micro-volumes below the surface in the granite samples and thereby avoid potential changes in the Np speciation during cutting of the bore core, a confocal irradiationdetection geometry is employed. µ-XAFS results for a selected granite bore core cross section with ~ 3 nmol Np/g reveal that Np, originally introduced as Np(V) in the tracer cocktail, is present in the granite in its reduced Np(IV) form. The Np(IV) is often present as particles, tens of µm in size. Elemental distribution maps show the tracer Np to be located in fissures and permeable channels not larger than 100 µm. The Np distribution appears often correlated with Zn also present in some fissures. We observe small granite fissures containing Fe (presumably Fe(II)), where we do not detect any Np. It is feasible that inflowing Np(V) has a shorter residence time in large fractures, while in the smaller fissures migration is slower, leading to longer residence times, i.e., reaction times, where it is reduced to less soluble Np(IV) and becomes thereby immobilized.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 21
DOI: 10.1016/J.SAB.2009.05.025
|
|
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials”. Kempenaers L, Vincze L, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 55, 651 (2000). http://doi.org/10.1016/S0584-8547(00)00207-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00207-X
|
|
|
“Blue enamel on sixteenth- and seventeenth-century window glass : deterioration, microstructure, composition and preparation”. van der Snickt G, Schalm O, Caen J, Janssens K, Schreiner M, Studies in conservation 51, 212 (2006). http://doi.org/10.1179/SIC.2006.51.3.212
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 0.578
Times cited: 8
DOI: 10.1179/SIC.2006.51.3.212
|
|
|
“Homogeneity, composition and deterioration of window glass fragments and paint layers from two seventeenth-century stained glass windows created by Jan de Caumont (similar to 1580-1659)”. Schalm O, Caen J, Janssens K, Studies in conservation 55, 216 (2010). http://doi.org/10.1179/SIC.2010.55.3.216
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 0.578
Times cited: 2
DOI: 10.1179/SIC.2010.55.3.216
|
|
|
“Lead soaps in paintings : friends or foes?”.Cotte M, Checroun E, De Nolf W, Taniguchi Y, De Viguerie L, Burghammer M, Walter P, Rivard C, Salome M, Janssens K, Susini J, Studies in conservation 62, 2 (2017). http://doi.org/10.1080/00393630.2016.1232529
Abstract: The origin(s) and role(s) of metal soaps in paints are a worldwide concern today. These hybrid compounds, containing both fatty acid chains and metals associated with a carboxylate function, are increasingly identified in paints. As reviewed in the first part of this work, the presence of metal soaps in paints is differently interpreted in scientific publications: metal soaps are sometimes considered to play a positive role as anchor points, during paint drying processes; they can also be considered as responsible for many degradation processes (protrusions, efflorescences, darkening, etc.). Their origins are also interpreted in various ways. In some paintings (in particular from the twentieth century), they have sometimes introduced on purpose, as additives, to modify the physical properties of the painting materials. In older paintings, metal soaps are usually thought to result from an uncontrolled reaction of oil with lead-based pigments, in particular lead white, red lead, and lead tin yellow. In the second part of this work, the review of historical recipes of lead-based paint shows an important number of recipes based on controlled mixing of oil with lead driers. In the third part, the experimental reproduction of such traditional recipes using walnut oil and litharge (PbO) shows that lead soaps can be formed, both in about one hour at approximate to 100 degrees C, or in about one month at room temperature. It shows as well that after a few years, litharge is no longer detected in the paint medium, while different lead carbonates are. Finally, the micro-infrared spectroscopy and micro-X-ray diffraction re-analysis of protrusions from a nine-year model painting shows together with lead soaps, the presence of Pb-5(CO3)(3)(OH)(2)O ('synthetic plumbonacrite'), an unusual phase recently observed in a protrusion from a painting by Vincent Van Gogh. This work highlights (i) the multiple origins and roles of metal soaps in paints and (ii) the importance of combining the analysis of fragments from historical paintings with the analysis and reproduction of historical recipes. In particular, we show that the components detected today in historical paintings may severely differ from those originally used or prepared by the painter, complicating the assessment of the painter's intentions. More than the presence of metal soaps, the key questions to be tackled should be about their origins and (re)mobilization.
Keywords: A1 Journal article; Art; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 0.578
Times cited: 26
DOI: 10.1080/00393630.2016.1232529
|
|
|
“Micro X-ray diffraction and fluorescence tomography for the study of multilayered automotive paints”. de Nolf W, Janssens K, Surface and interface analysis 42, 411 (2010). http://doi.org/10.1002/SIA.3125
Abstract: Combined microscopic X-ray fluorescence/microscopic X-ray diffraction (µ-XRF/µ-XRD) tomography is a recently developed method that allows the visualization of the distribution of chemical elements and the associated crystalline phases inside complex, heterogeneous materials of extended thickness (millimeter range) in a nondestructive fashion. In this paper, the accuracy and resolution with which the individual layers in a multilayer stack of automotive paints can be distinguished is evaluated, and some of their properties measured. A paint layer system of eight layers was investigated, in which eight different crystalline substances were identified, each layer consisting of an organic, synthetic resin doped with finely milled inorganic compounds that serve as pigments or to strengthen the layer. In the XRD tomograms, all paint layers could be straightforwardly distinguished and their average thickness calculated. In case the filtered back projection method was used for tomogram reconstruction, a spatial resolution comparable to the microbeam size was obtained indicating no significant reconstruction blurring. When a more robust reconstruction method, such as the maximum-likelihood expectation maximization method, was employed, tomograms showing fewer artifacts were obtained, but with a spatial resolution that was two times worse. In the corresponding XRF tomograms, significant self-absorption distorted the element-specific tomograms corresponding to the low-energy (<7 keV) characteristic radiation and limited their usefulness. It can be concluded that microbeam XRD tomography allows the accurate visualization of the distribution of crystalline phases in multilayered automotive paint materials of millimeter dimensions with sufficient resolution to allow separate characterization of each layer in terms of its crystal-phase composition and thickness.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.132
Times cited: 70
DOI: 10.1002/SIA.3125
|
|
|
“Colloquium Spectroscopicum Internationale 34, Antwerp, Belgium, 4-9 September 2005: preface”. Janssens K, Bogaerts A, van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 70, 907 (2006). http://doi.org/10.1016/j.talanta.2006.05.044
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
DOI: 10.1016/j.talanta.2006.05.044
|
|
|
“An adhesive conducting electrode material based on commercial mesoporous titanium dioxide as a support for Horseradish peroxidase for bioelectrochemical applications”. Rahemi V, Trashin S, Meynen V, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 146, 689 (2016). http://doi.org/10.1016/J.TALANTA.2015.06.041
Abstract: An adhesive conducting electrode material containing of graphite, biocompatible ion exchange polymer nafion® and commercial mesoporous TiO2 impregnated with horseradish peroxidase (HRP) is prepared and characterized by amperometric, UVvis and N2 sorption methods. The factors influencing the performance of the resulting biosensor are studied in detail. The optimal electrode material consists of 45% graphite, 50% impregnated HRPTiO2 and 5% nafion®. The optimum conditions for H2O2 reduction are an applied potential of 0.3 V and 0.1 mM hydroquinone. Sensitivity and limit of detection in the optimum conditions are 1 A M−1 cm−2 and 1 µM correspondingly. The N2 sorption results show that the pore volume of TiO2 decreases sharply upon adsorption of HRP. The preparation process of the proposed enzyme electrode is straightforward and potentially can be used for preparation of carbon paste electrodes for bioelectrochemical detections.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 7
DOI: 10.1016/J.TALANTA.2015.06.041
|
|
|
“Chemical boundary conditions for the classification of aerosol particles using computer controlled electron probe microanalysis”. Anaf W, Horemans B, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 101, 420 (2012). http://doi.org/10.1016/J.TALANTA.2012.09.051
Abstract: A method for the classification of individual aerosol particles using computer controlled electron probe microanalysis is presented. It is based on chemical boundary conditions (CBC) and enables quick and easy processing of a large set of elemental concentration data (mass%), derived from the X-ray spectra of individual particles. The particles are first classified into five major classes (sea salt related, secondary inorganic, minerals, iron-rich and carbonaceous), after which advanced data mining can be performed by examining the elemental composition of particles within each class into more detail (e.g., by ternary diagrams). The CBC method is validated and evaluated by comparing its results with the output obtained with hierarchical cluster analysis (HCA) for well-known standard particles as well as real aerosol particles collected with a cascade impactor. The CBC method gives reliable results and has a major advantage compared to HCA. CBC is based on boundary conditions that are derived from chemical logical thinking and does not require a translation of a mathematical algorithm output as does HCA. Therefore, the CBC method is more objective and enables comparison between samples without intermediate steps.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 3
DOI: 10.1016/J.TALANTA.2012.09.051
|
|
|
“Optimization of the ion chromatographic quantification of airborne fluoride, acetate and formate in the Metropolitan Museum of Art, New York”. Kontozova-Deutsch V, Deutsch F, Bencs L, Krata A, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 86, 372 (2011). http://doi.org/10.1016/J.TALANTA.2011.09.030
Abstract: Ion chromatographic (IC) methods have been compared in order to achieve an optimal separation of fluoride, acetate and formate under various elution conditions on two formerly introduced analytical columns (i and ii) and a novel one (iii): (i) an IonPac AS14 (250 mm × 4 mm I.D.), (ii) Allsep A-2 (150 mm × 4.6 mm I.D.), and (iii) an IC SI-50 4E (250 mm (length) × 4 mm (internal diameter – I.D.)). The IC conditions for the separation of the anions concerned were optimized on the IC SI-50 4E column. A near baseline separation of these anions was attained on the IonPac AS14, whereas the peaks of fluoride and acetate could not be resolved on the Allsep A-2. A baseline separation for the three anions was achieved on the IC SI-50 4E column, when applying an eluent mixture of 3.2 mmol/L Na2CO3 and 1.0 mmol/L NaHCO3 with a flow rate of 1.0 mL/min. The highest precision of 1.7, 3.0 and 2.8% and the best limits of detection (LODs) of 0.014, 0.22 and 0.17 mg/L for fluoride, acetate and formate, respectively, were obtained with the IC SI-50 4E column. Hence, this column was applied for the determination of the acetic and formic acid contents of air samples taken by means of passive gaseous sampling at the Metropolitan Museum of Art in New York, USA. Atmospheric concentrations of acetic and formic acid up to 1050 and 450 μg/m3, respectively, were found in non-aerated showcases of the museum. In galleries and outdoors, rather low levels of acetic and formic acid were detected with average concentrations of 50 and 10 μg/m3, respectively. The LOD data of acetate and formate on the IC SI-50 4E column correspond to around 0.5 μg/m3 for both acetic and formic acid in air samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 19
DOI: 10.1016/J.TALANTA.2011.09.030
|
|
|
“Polymer platforms for selective detection of cocaine in street samples adulterated with levamisole”. Florea A, Cowen T, Piletsky S, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 186, 362 (2018). http://doi.org/10.1016/J.TALANTA.2018.04.061
Abstract: Accurate drug detection is of utmost importance for fighting against drug abuse. With a high number of cutting agents and adulterants being added to cut or mask drugs in street powders the number of false results is increasing. We demonstrate for the first time the usefulness of employing polymers readily synthesized by electrodeposition to selectively detect cocaine in the presence of the commonly used adulterant levamisole. The polymers were selected by computational modelling to exhibit high binding affinity towards cocaine and deposited directly on the surface of graphene-modified electrodes via electropolymerization. The resulting platforms allowed a distinct electrochemical signal for cocaine, which is otherwise suppressed by levamisole. Square wave voltammetry was used to quantify cocaine alone and in the presence of levamisole. The usefulness of the platforms was demonstrated in the screening of real street samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 9
DOI: 10.1016/J.TALANTA.2018.04.061
|
|
|
“Stable carbon isotopic ratio measurement of polycyclic aromatic hydrocarbons as a tool for source identification and apportionment : a review of analytical methodologies”. Buczyńska AJ, Geypens B, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 105, 435 (2013). http://doi.org/10.1016/J.TALANTA.2012.10.075
Abstract: The measurement of the ratio of stable isotopes of carbon (13C/12C expressed as a δ13C) in the individual components of a sample may be used as a means to identify the origin of these components. This article reviews the approaches and reports on the successes and failures of source identification and apportionment of Polycyclic Aromatic Hydrocarbons (PAHs) with the use of compound-specific isotope analysis (CSIA). One of the conditions for a precise and accurate analysis of isotope ratios with the use of GC-C-IRMS is the need for well separated peaks, with no co-elutions, and reduced unresolved complex mixture (UCM). Additionally, special care needs to be taken for an investigation of possible isotope fractionation effects introduced during the analytical treatment of samples. With the above-mentioned problems in mind, this review discusses in detail and compares current laboratory methodologies, mainly in the extraction and subsequent clean-up techniques used for environmental samples (air particulate matter, soil and sediments). Sampling strategies, the use of isotopic internal standards and the ranges for precision and accuracy are also reported and discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 19
DOI: 10.1016/J.TALANTA.2012.10.075
|
|
|
“Evaluation of a calibration transfer between a bench top and portable Mid-InfraRed spectrometer for cocaine classification and quantification”. Eliaerts J, Meert N, Dardenne P, Van Durme F, Baeten V, Samyn N, De Wael K, Talanta 209, 120481 (2020). http://doi.org/10.1016/J.TALANTA.2019.120481
Abstract: A portable Fourier Transform Mid-InfraRed (FT-MIR) spectrometer using Attenuated Total Reflectance (ATR) sampling is used for daily routine screening of seized powders. Earlier, ATR-FT-MIR combined with Support Vector Machines (SVM) algorithms resulted in a significant improvement of the screening method to a reliable and straightforward classification and quantification tool for both cocaine and levamisole. However, can this tool be transferred to new (hand-held) devices, without loss of the extensive data set? The objective of this study was to perform a calibration transfer between a newly purchased bench top (BT) spectrometer and a portable (P) spectrometer with existing calibration models. Both instruments are from the same brand and have identical characteristics and acquisition parameters (FT instrument, resolution of 4 cm(-1) and wavenumber range 4000 to 500 cm(-1)). The original SVM classification model (n = 515) and SVM quantification model (n = 378) were considered for the transfer trial. Three calibration transfer strategies were assessed: 1) adjustment of slope and bias; 2) correction of spectra from the new instrument BT to P using Piecewise Direct Standardization (PDS) and 3) building a new mixed instrument model with spectra of both instruments. For each approach, additional cocaine powders were measured (n = 682) and the results were compared with GC-MS and GC-FID. The development of a mixed instrument model was the most successful in terms of performance. The future strategy of a mixed model allows applying the models, developed in the laboratory, to portable instruments that are used on-site, and vice versa. The approach offers opportunities to exchange data within a network of forensic laboratories using other FT-MIR spectrometers.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.1
Times cited: 2
DOI: 10.1016/J.TALANTA.2019.120481
|
|
|
“Macroscopic mid-FTIR mapping and clustering-based automated data-reduction : an advanced diagnostic tool for in situ investigations of artworks”. Sciutto G, Legrand S, Catelli E, Prati S, Malegori C, Oliveri P, Janssens K, Mazzeo R, Talanta 209, 120575 (2020). http://doi.org/10.1016/J.TALANTA.2019.120575
Abstract: The present study describes a multivariate strategy that can be used for automatic on-site processing of reflection mode macro FTIR mapping (MA-rFTIR) data obtained during investigation of artworks. The chemometric strategy is based on the integration of principal component analysis (PCA) with a clustering approach in the space subtended by the three lowest-order principal components and allows to automatically identify the regions of interest (ROIs) of the area scanned and to extract the average FTIR spectra related to each ROI. Thanks to the automatic data management, in-field HSI (hyperspectral imaging)-based analyses may be performed even by staff lacking specific advanced chemometric expertise, as it is sometimes the case for conservation scientists or conservators with a scientific background. MA-rFTIR was only recently introduced in the conservation field and, in this work the technique was employed to characterize the surface of metallic artefacts. The analytical protocol was employed as part of a rapid procedure to evaluate the conservation state and the performance of cleaning methods on bronze objects. Both activities are commonly part of restoration campaigns of bronzes and require an on-site analytical procedure for efficient and effective diagnosis. The performance of the method was first evaluated on aged standard samples (bronzes with a layer of green basic copper hydroxysulphate, treated with different organic coatings) and then scrutinized in situ on areas of the 16th century Neptune fountain statue (Piazza del Nettuno, Bologna, Italy) by Gianbologna.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.1
DOI: 10.1016/J.TALANTA.2019.120575
|
|
|
“The opportunity of 6-monoacetylmorphine to selectively detect heroin at preanodized screen printed electrodes”. Felipe Montiel N, Parrilla M, Beltrán V, Nuyts G, Van Durme F, De Wael K, Talanta , 122005 (2021). http://doi.org/10.1016/j.talanta.2020.122005
Abstract: The illicit consumption of heroin is an increasing concern in our society. For this reason, rapid analytical methods to seize heroin samples in the field are of paramount importance to hinder drug trafficking, and thus prevent the availability of heroin in the drug market. The present work reports on the enriched electrochemical fingerprint of heroin, allowing its selective detection in street samples, based on the use of electrochemical pretreated screen printed electrodes (p-SPE). The voltammetric identification is built on two oxidation peaks of both heroin and its degradation product 6-monoacetylmorphine (6-MAM), generated in alkaline conditions. Interestingly, an anodic pretreatment of the screen printed electrodes (SPE) shifts the peak potential of paracetamol (the most encountered cutting agent in heroin seizures), allowing the detection of 6-MAM peak, overlapping with the paracetamol signal in the case of untreated SPE. Subsequently, the characterization of the p-SPE with scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy, Raman and Fourier transform infrared (FTIR) spectroscopy is provided to demonstrate local changes on the surface of the electrode. From an analytical perspective, p-SPE provide higher sensitivity (0.019 μA μM-1), excellent reproducibility (6-MAM, RSD = 2.85%, and heroin RSD = 0.91%, n = 5) and lower limits of detection (LOD) (5.2 μM) in comparison to untreated SPE. The proposed protocol which integrates a tailor-made script is interrogated against common cutting agents, and finally, validated with the screening of 14 street samples, also analyzed by standard methods. Besides, a comparison with portable spectroscopic techniques on the confiscated samples shows the better performance of the electrochemical strategy. Overall, this sensing approach offers promising results for the rapid on-site profiling of suspicious heroin samples, also in the presence of paracetamol.
Keywords: A1 Journal Article; Antwerp X-ray Analysis, Electrochemistry and Speciation (AXES) ;
Impact Factor: 4.162
DOI: 10.1016/j.talanta.2020.122005
|
|
|
“Aptamer-ligand recognition studied by native ion mobility-mass spectrometry”. Daems E, Dewaele D, Barylyuk K, De Wael K, Sobott F, Talanta 224, 121917 (2021). http://doi.org/10.1016/J.TALANTA.2020.121917
Abstract: The range of applications for aptamers, small oligonucleotide-based receptors binding to their targets with high specificity and affinity, has been steadily expanding. Our understanding of the mechanisms governing aptamer-ligand recognition and binding is however lagging, stymieing the progress in the rational design of new aptamers and optimization of the known ones. Here we demonstrate the capabilities and limitations of native ion mobility-mass spectrometry for the analysis of their higher-order structure and non-covalent interactions. A set of related cocaine-binding aptamers, displaying a range of folding properties and ligand binding affinities, was used as a case study in both positive and negative electrospray ionization modes. Using carefully controlled experimental conditions, we probed their conformational behavior and interactions with the high-affinity ligand quinine as a surrogate for cocaine. The ratios of bound and unbound aptamers in the mass spectra were used to rank them according to their apparent quinine-binding affinity, qualitatively matching the published ranking order. The arrival time differences between the free aptamer and aptamer-quinine complexes were consistent with a small ligand-induced conformational change, and found to inversely correlate with the affinity of binding. This mass spectrometry-based approach provides a fast and convenient way to study the molecular basis of aptamer-ligand recognition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
DOI: 10.1016/J.TALANTA.2020.121917
|
|
|
“Unlocking the full potential of voltammetric data analysis : a novel peak recognition approach for (bio)analytical applications”. Van Echelpoel R, de Jong M, Daems D, van Espen P, De Wael K, Talanta 233, 122605 (2021). http://doi.org/10.1016/J.TALANTA.2021.122605
Abstract: Bridging the gap between complex signal data output and clear interpretation by non-expert end-users is a major challenge many scientists face when converting their scientific technology into a real-life application. Currently, pattern recognition algorithms are the most frequently encountered signal data interpretation algorithms to close this gap, not in the least because of their straight-forward implementation via convenient software packages. Paradoxically, just because their implementation is so straight-forward, it becomes cumbersome to integrate the expert's domain-specific knowledge. In this work, a novel signal data interpretation approach is presented that uses this domain-specific knowledge as its fundament, thereby fully exploiting the unique expertise of the scientist. The new approach applies data preprocessing in an innovative way that transcends its usual purpose and is easy to translate into a software application. Multiple case studies illustrate the straight-forward application of the novel approach. Ultimately, the approach is highly suited for integration in various (bio)analytical applications that require interpretation of signal data.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
DOI: 10.1016/J.TALANTA.2021.122605
|
|
|
“Non-invasive and non-destructive examination of artistic pigments, paints, and paintings by means of X-Ray methods”. Janssens K, van der Snickt G, Vanmeert F, Legrand S, Nuyts G, Alfeld M, Monico L, Anaf W, de Nolf W, Vermeulen M, Verbeeck J, De Wael K, Topics in Current Chemistry 374, 81 (2016). http://doi.org/10.1007/S41061-016-0079-2
Abstract: Recent studies are concisely reviewed, in which X-ray beams of (sub)micrometre to millimetre dimensions have been used for non-destructive analysis and characterization of pigments, minute paint samples, and/or entire paintings from the seventeenth to the early twentieth century painters. The overview presented encompasses the use of laboratory and synchrotron radiation-based instrumentation and deals with the use of several variants of X-ray fluorescence (XRF) as a method of elemental analysis and imaging, as well as with the combined use of X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Microscopic XRF is a variant of the method that is well suited to visualize the elemental distribution of key elements, mostly metals, present in paint multi-layers, on the length scale from 1 to 100 μm inside micro-samples taken from paintings. In the context of the characterization of artists pigments subjected to natural degradation, the use of methods limited to elemental analysis or imaging usually is not sufficient to elucidate the chemical transformations that have taken place. However, at synchrotron facilities, combinations of μ-XRF with related methods such as μ-XAS and μ-XRD have proven themselves to be very suitable for such studies. Their use is often combined with microscopic Fourier transform infra-red spectroscopy and/or Raman microscopy since these methods deliver complementary information of high molecular specificity at more or less the same length scale as the X-ray microprobe techniques. Since microscopic investigation of a relatively limited number of minute paint samples, taken from a given work of art, may not yield representative information about the entire artefact, several methods for macroscopic, non-invasive imaging have recently been developed. Those based on XRF scanning and full-field hyperspectral imaging appear very promising; some recent published results are discussed.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.033
Times cited: 50
DOI: 10.1007/S41061-016-0079-2
|
|
|
“Mitigation strategies for radiation damage in the analysis of ancient materials”. Bertrand L, Schoeeder S, Anglos D, Breese MBH, Janssens K, Moini M, Simon A, Trends in analytical chemistry 66, 128 (2015). http://doi.org/10.1016/J.TRAC.2014.10.005
Abstract: The study of materials in cultural heritage artifacts and micro-samples benefits from diagnostic techniques based on intense radiation sources, such as synchrotrons, ion-beam accelerators and lasers. While most of the corresponding techniques are classified as non-destructive, investigation with photons or charged particles entails a number of fundamental processes that may induce changes in materials. These changes depend on irradiation parameters, properties of materials and environmental factors. In some cases, radiation-induced damage may be detected by visual inspection. When it is not, irradiation may still lead to atomic and molecular changes resulting in immediate or delayed alteration and bias of future analyses. Here we review the effects of radiation reported on a variety of cultural heritage materials and describe the usual practice for assessing short-term and long-term effects. This review aims to raise awareness and encourage subsequent research activities to limit radiation side effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 35
DOI: 10.1016/J.TRAC.2014.10.005
|
|