|
“Co-crystallization with 1-(2-pyridylazo)-2-naphthol, and X-ray fluorescence, for trace metal analysis of water”. Vanderstappen MG, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 25, 653 (1978). http://doi.org/10.1016/0039-9140(78)80166-0
Abstract: Adding 20mg of 1-(2-pyridylazo)-2-naphthol (PAN) to a water sample at 70°, and filtering off the precipitate after cooling, gives efficient preconcentration prior to X-ray fluorescence analysis of water. Up to the capacity of about 100 μeq of PAN used, the trace metal recoveries are around 90% or higher for Cr3+, Mn2+, Ni2+, Cu2+, Zn2+, Hg2+ and Eu3+, and above 70% for many other ions. The recovery yields usually do not vary critically with pH in the neutral pH-range, and are practically independent of the sample salinity, sample volume and trace-metal concentration. Enrichment factors as high as 2 × 105 can be achieved. Counting statistics would then allow detection limits of 0.03 ppM. The blank levels in commercial PAN, however, lead to typical detection limits of about 1 ppm. The coefficient of variation is typically in the 510% range at the 10-ppM level. The accuracy and applicability of the procedure are illustrated by comparative analyses on samples of synthetic solutions, river and drinking water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(78)80166-0
|
|
|
“Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water”. Van Grieken RE, Bresseleers CM, Vanderborght BM, Analytical chemistry 49, 1326 (1977). http://doi.org/10.1021/AC50017A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50017A011
|
|
|
“Enrichment of trace metals in water by adsorption on activated carbon”. Vanderborght BM, Van Grieken RE, Analytical chemistry 49, 311 (1977)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Elemental trace analysis of small samples by proton-induced X-ray-emission”. Johansson TB, Van Grieken RE, Nelson JW, Winchester JW, Analytical chemistry 47, 855 (1975). http://doi.org/10.1021/AC60356A035
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60356A035
|
|
|
“Absorption correction for X-ray-fluorescence analysis of aerosol loaded filters”. Adams FC, Van Grieken RE, Analytical chemistry 47, 1767 (1975). http://doi.org/10.1021/AC60361A040
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60361A040
|
|
|
“Geometry errors in 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 13, 225 (1973). http://doi.org/10.1007/BF02514126
Abstract: The effects of inaccurate sample sizes and sample positioning on 14 MeV neutron activation analysis results are estimated for 30, 20 and 10 mm diameter targets. It appears that axial positioning is the most critical parameter and that using a larger tritium target will yield an overall improvement of the reproducibility.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02514126
|
|
|
“Spatial neutron flux distributions around A 14 MeV neutron generator”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 10, 95 (1972). http://doi.org/10.1007/BF02518771
Abstract: The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02518771
|
|
|
“The half-life of 28Al”. Van Schandevijl R, Van Grieken R, Hoste J, Journal of radioanalytical chemistry 9, 55 (1971). http://doi.org/10.1007/BF02514012
Abstract: The half-life of28Al was redetermined on aluminium samples of different origin. Three different counting techniques were applied. The availability of highly purified samples (up to 99.9999%), the use of very fast electronic counting equipment and a complete automatisation allowed a good precision to be obtained in the final result of 2.2405 min.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02514012
|
|
|
“Simultaneous determination of silicon and phosphorus in cast iron by 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 6, 385 (1970). http://doi.org/10.1007/BF02513966
Abstract: A fast (10 min), non-destructive simultaneous determination of silicon and phosphorus in cast iron and steel by 14 MeV neutron activation was developed. The 1.78 MeV28Al activity (T=2.24 min) induced by the reaction28Si(n, p)28Al is counted on a NaI(Tl) detector. Two measurements are made to correct for the 1.81 MeV56Mn activity (T=2.58 hr) from the iron matrix. However,28Al is also produced via31P(n, α)28Al. By (n, 2n) reaction, phosphorus yields also30P (T=2.6 min), the 0.511 MeV annihilation radiation of which is counted by two opposite NaI(Tl) detectors in coincidence. Again, two successive coincidence measurements are carried out in order to take into account the53Fe activity (β+; T=8.9 min) from54Fe(n, 2n)53Fe. The28Al measurement is appropriately corrected via the computed phosphorus content. An oxygen flux monitor was used to normalize to the same flux. Nuclear interferences have been examined. Special attention has been paid to the presence of copper. The standard deviation for phosphorus being as high as ca. 0.09% P for a single determination, this technique can only be practical as an independent phosphorus analysis for high phosphorus cast irons. The precision on the28Al measurement is 5% relative for 0.2% Si and 2.5% above 1% Si.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02513966
|
|