Details
   web
Record
Author Van den Broek, W.; Reed, B.W.; Béché, A.; Velazco, A.; Verbeeck, J.; Koch, C.T.
Title Various compressed sensing setups evaluated against Shannon sampling under constraint of constant illumination Type A1 Journal article
Year (down) 2019 Publication IEEE transactions on computational imaging Abbreviated Journal
Volume 5 Issue 3 Pages 502-514
Keywords A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Abstract Under the constraint of constant illumination, an information criterion is formulated for the Fisher information that compressed sensing measurements in optical and transmission electron microscopy contain about the underlying parameters. Since this approach requires prior knowledge of the signal's support in the sparse basis, we develop a heuristic quantity, the detective quantum efficiency (DQE), that tracks this information criterion well without this knowledge. In this paper, it is shown that for the investigated choice of sensing matrices, and in the absence of read-out noise, i.e., with only Poisson noise present, compressed sensing does not raise the amount of Fisher information in the recordings above that of Shannon sampling. Furthermore, enabled by the DQE's analytical tractability, the experimental designs are optimized by finding out the optimal fraction of on pixels as a function of dose and read-out noise. Finally, we introduce a regularization and demonstrate, through simulations and experiment, that it yields reconstructions attaining minimum mean squared error at experimental settings predicted by the DQE as optimal.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000480352600013 Publication Date 2019-01-24
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2333-9403 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.546 Times cited 7 Open Access
Notes ; This work was supported by the Hercules fund from the Flemish Government (Qu-Ant-EM microscope used for the experimental data). The work of W. Van den Broek was supported by the DFG under Grant BR 5095/2-1 (Compressed sensing in ptychography and transmission electron microscopy). The work of A. Beche, A. Velazco, and J. Verbeeck was supported by the FWO under Grant G093417N (Compressed sensing enabling low dose imaging in transmission electron microscopy). The work of Christoph T. Koch was supported by the DFG under Grant CRC 951. The associate editor coordinating the review of this manuscript and approving it for publication was Dr. Chrysanthe Preza. ; Approved Most recent IF: NA
Call Number UA @ admin @ c:irua:161792 Serial 5368