|
“Application of high-energy polarised beam energy dispersive X-ray fluorescence spectrometry to cadmium determination in saline solutions”. van Meel K, Fontàs C, Van Grieken R, Queralt I, Hidalgo M, Marguí, E, Journal of analytical atomic spectrometry 23, 1034 (2008). http://doi.org/10.1039/B718382H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B718382H
|
|
|
“Chemical characterization and multivariate analysis of atmospheric PM2.5 particles”. Ravindra K, Stranger M, Van Grieken R, Journal of atmospheric chemistry 59, 199 (2008). http://doi.org/10.1007/S10874-008-9102-5
Abstract: The new European Council Directive (PE-CONS 3696/07) frames the inhalable (PM10) and fine particles (PM2.5) on priority to chemically characterize these fractions in order to understand their possible relation with health effects. Considering this, PM2.5 was collected during four different seasons to evaluate the relative abundance of bulk elements (Cl, S, Si, Al, Br, Cu, Fe, Ti, Ca, K, Pb, Zn, Ni, Mn, Cr and V) and water soluble ions (F−, Cl−, NO2 −, NO3 −, SO4 2−, Na+, NH4 +, Ca2+ and Mg2+) over Menen, a Belgian city near the French border. The air quality over Menen is influenced by industrialized regions on both sides of the border. The most abundant ionic species were NO3 −, SO4 2− and NH4 +, and they showed distinct seasonal variation. The elevated levels of NO3 − during spring and summer were found to be related to the larger availability of the NOx precursor. The various elemental species analyzed were distinguished into crustal and anthropogenic source categories. The dominating elements were S and Cl in the PM2.5 particles. The anthropogenic fraction (e.g. Zn, Pb, and Cu) shows a more scattered abundance. Furthermore, the ions and elemental data were also processed using principal component analysis and cluster analysis to identify their sources and chemistry. These approach identifies anthropogenic (traffic and industrial) emissions as a major source for fine particles. The variations in the natural/anthropogenic fractions of PM2.5 were also found to be a function of meteorological conditions as well as of long-range transport of air masses from the industrialized regions of the continent.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10874-008-9102-5
|
|
|
“Fast analysis of decabrominated diphenyl ether using low-pressure gas chromatography.electron-capture negative ionization mass spectrometry”. Dirtu AC, Ravindra K, Roosens L, Van Grieken R, Neels H, Blust R, Covaci A, Journal of chromatography : A 1186, 295 (2008). http://doi.org/10.1016/J.CHROMA.2007.07.034
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
DOI: 10.1016/J.CHROMA.2007.07.034
|
|
|
“Airborne particulate matter and BTEX in office environments”. Horemans B, Worobiec A, Buczyńska A, van Meel K, Van Grieken R, Journal of environmental monitoring 10, 867 (2008). http://doi.org/10.1039/B804475A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1039/B804475A
|
|
|
“Mass and ionic composition of atmospheric fine particles over Belgium and their relation with gaseous air pollutants”. Bencs L, Ravindra K, de Hoog J, Rasoazanany EO, Deutsch F, Bleux N, Berghmans P, Roekens E, Krata A, Van Grieken R, Journal of environmental monitoring 10, 1148 (2008). http://doi.org/10.1039/B805157G
Abstract: Mass, major ionic components (MICs) of PM2.5, and related gaseous pollutants (SO2, NOx, NH3, HNO2, and HNO3) were monitored over six locations of different anthropogenic influence (industrial, urban, suburban, and rural) in Belgium. SO42-, NO3-, NH4+, and Na+ were the primary ions of PM2.5 with averages diurnal concentrations ranging from 0.44.5, 0.37.6, 0.94.9, and 0.41.2 µg m-3, respectively. MICs formed 39% of PM2.5 on an average, but it could reach up to 8098%. The SO2, NO, NO2, HNO2, and HNO3 levels showed high seasonal and site-specific fluctuations. The NH3 levels were similar over all the sites (26 µg m-3), indicating its relation to the evenly distributed animal husbandry activities. The sulfur and nitrogen oxidation ratios for PM2.5 point towards a low-to-moderate formation of secondary sulfate and nitrate aerosols over five cities/towns, but their fairly intensive formation over the rural Wingene. Cluster analysis revealed the association of three groups of compounds in PM2.5: (i) NH4NO3, KNO3; (ii) Na2SO4; and (iii) MgCl2, CaCl2, MgF2, CaF2, corresponding to anthropogenic, sea-salt, and mixed (sea-salt + anthropogenic) aerosols, respectively. The neutralization and cation-to-anion ratios indicate that MICs of PM2.5 appeared mostly as (NH4)2SO4 and NH4NO3 salts. Sea-salt input was maximal during winter reaching up to 12% of PM2.5. The overall average Cl-loss for sea-salt particles of PM2.5 at the six sites varied between 69 and 96% with an average of 87%. Principal component analysis revealed vehicular emission, coal/wood burning and animal farming as the dominating sources for the ionic components of PM2.5.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B805157G
|
|
|
“Sample damage during X-ray fluorescence analysis: case study on ammonium salts in atmospheric aerosols”. van Meel K, Worobiec A, Stranger M, Van Grieken R, Journal of environmental monitoring 10, 989 (2008). http://doi.org/10.1039/B807909A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1039/B807909A
|
|
|
“A new method for the evaluation of the reversible and irreversible fouling propensity of MBR mixed liquor”. Huyskens C, Brauns E, van Hoof E, de Wever H, Journal of membrane science 323, 185 (2008). http://doi.org/10.1016/J.MEMSCI.2008.06.021
Abstract: In this paper, a new fouling measurement method is presented as a pragmatic approach to determine a mixed liquor's fouling propensity. The MBR-VFM (VITO Fouling Measurement) uses a specific measurement protocol consisting of alternating filtration and physical cleaning steps, which enables the calculation of both the reversible and the irreversible fouling resistances. The MBR-VFM principle, set-up and measurement protocol are described as well as the evaluation of the fouling measurement method. Finally, the MBR-VFM was validated by comparing the fouling propensity measured on-line by the MBR-VFM in a lab-scale MBR with the fouling of the MBR membranes themselves. Our experiments indicated that the MBR-VFM can accurately measure fouling and that it can even be detected earlier than can be seen from the on-line filtration data of the lab-scale system itself. Furthermore, the differences measured in reversible and irreversible fouling seemed to be related to the observed impact of physical and chemical cleaning respectively. Therefore, the application of the MBR-VFM as an on-line sensor in an advanced control system, enabling the deployment of the measured fouling data for the control of membrane cleaning, seems feasible and will be tested in the near future.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1016/J.MEMSCI.2008.06.021
|
|
|
“Recognition of uranium oxides in soil particulate matter by means of ì-Raman spectrometry”. Stefaniak EA, Sajó, I, Alsecz A, Worobiec A, Máthé, Z, Török S, Van Grieken R, Journal of nuclear materials 381, 278 (2008). http://doi.org/10.1016/J.JNUCMAT.2008.08.036
Abstract: Soil samples from an abandoned uranium mine have been investigated in order to determine the molecular phases of uranium compounds. The experiments were carried out with soil particulate matter, collected randomly from the area of the formerly exploited ore. To select the particles rich with uranium, scanning electron microscopy with energy-dispersive X-ray attachment (SEM/EDX) was applied first. Afterwards, the particles were relocated and measured by l-Raman spectrometry (MRS). Residues of the main deposit, uraninite UO2, were detected, along with its alteration products. In terms of Raman scattering properties, uranium oxides are quite sensitive to the laser beam wavelength, which results in very specific features of their Raman spectra. In this paper the Raman spectra of uranium oxides of different origin and oxidation states, measured with 514 and 785 nm lasers, are also presented
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.JNUCMAT.2008.08.036
|
|
|
“Monitoring of NO2 in the ambient air with passive samplers before and after a road reconstruction event”. Stranger M, Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Worobiec A, Naveau I, Roekens E, Van Grieken R, Microchemical journal 90, 93 (2008). http://doi.org/10.1016/J.MICROC.2008.04.001
Abstract: Nitrogen dioxide (NO2) concentrations were used to evaluate the air quality before and after the infrastructural change of an important traffic artery in Mortsel, Antwerp (Belgium). During the reconstruction works two pairs of traffic lanes were reduced to one in each direction. Two sampling campaigns were conducted: the first one before the works in 2003 and the second one in 2005, after the road works were finished. Sampling was performed on a weekly base with the use of passive diffusion tubes on the streets, and also indoors in nearby houses. The samples were analyzed by ion chromatography, from which data the NO2 concentrations in air could be calculated. These results were compared with NO2 values from the air monitoring station 42R801 of the Flemish Environment Agency in Borgerhout, Antwerp. On the base of different NO2 concentrations, correlated well with the traffic density, sampling locations were classified into three groups as follows: 1) heavily polluted (heavy traffic); 2) moderately polluted (medium traffic); or 3) less polluted (low traffic density). Sampling sites located further from the road works, enclosed to the group less polluted, showedthe lowestNO2 concentrations. The highestNO2 levelwas found for the locations close to reconstructionworks, which belonged to the group heavily polluted. The contribution of NO2 was at the samelevel before and after the roadworks. During the first campaign it ranged from30±7 µg/m3 to 71±11 µg/m3 and during the second sampling itwas between 36±17 µg/m3 and 73±17 µg/m3. These modernizationworks had no impact on preventing the traffic-related pollutant as NO2 and as a consequence no significant effect on the air quality in the studied region. It has been proven that the impact of traffic on the air quality is unmistakably high and simply reduction of the number of the traffic lanes, intended to discourage the traffic flow, had apparently no environmentally advantageous effect
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2008.04.001
|
|
|
“Redistribution of uranium and thorium by soil/plant interaction in a recultivated mining area”. Mihucz VG, Varga Z, Tatár E, Virág I, Van Grieken R, Koleszár Z, Záray G, Microchemical journal 90, 44 (2008). http://doi.org/10.1016/J.MICROC.2008.03.004
Abstract: During the recultivation of the uranium mining area of Kõvágószõlõs (Hungary), the tailings were covered with clay and loess soil layers having a thickness of 30 cm and 100 cm, respectively. In the loess covering layer, acacia (Robinia pseudoacacia), poplars (Populus × albus, Populus × canescens), oak (Quercus pubescens), silver tree (Eleagnus angustifolia) were planted between 1996 and 2004. In order to establish the extent of the uranium and thorium transport from the sludge to the leaves by uptake and translocation processes through roots with a length higher than 1.3 m results in a remarkable redistribution of these pollutants, a gray poplar tree, growing spontaneously in the last uncovered tailing, being selected as reference tree. The U and Th concentrations in the leaves of the above-mentioned trees, in the covering layers as well as in the original sludge were determined by inductively coupled plasma sector field mass spectrometry (ICP-SF-MS). Generally, the Th concentration of the soils was about 4 times higher than that of uranium, while uranium concentration was about 10130 times higher than that of thorium in the leaf samples and its concentration ranged from 28 to 1045 ng g− 1, the last value belonging to the poplar tree growing on the last uncovered tailing. In order to assume the mobility and bioavailability of uranium if the dry leaves fall down, the uranium species in the leaves of the poplar tree growing in the uncovered reservoir were determined applying ultrasound-assisted extraction with distilled water and ammonium acetate as well as high performance liquid chromatographic (HPLC)-ICP-SF-MS technique. About 20% of total uranium could be extracted in form of uranyl cations and a presumably negatively charged uranium compound. Estimations revealed that the annual increment of U in the soil surface layer due to the dead fallen leaves in case of the investigated gray poplar (Populus × canescens) is about 1.2%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MICROC.2008.03.004
|
|
|
“A seasonal study of atmospheric conditions influenced by the intensive tourist flow in the Royal Museum of Wawel Castle in Cracow, Poland”. Worobiec A, Samek L, Karaszkiewicz P, Kontozova-Deutsch V, Stefaniak EA, van Meel K, Krata A, Bencs L, Van Grieken R, Microchemical journal 90, 99 (2008). http://doi.org/10.1016/J.MICROC.2008.04.005
Abstract: Increasingmass tourismcan generate importantmicroclimatic perturbations and also elevate indoor pollution by the transport of fine particulatematter. The purpose of this researchwas to study the indoor air conditions in the RoyalMuseum ofWawel Castle in Cracow, Poland, displaying amongst other valuable works of art also a unique collection of Flemish tapestries. The investigation involved in the determination of transport and deposition of particulate matter brought in by visitors. The microclimate inside the exhibition rooms was also monitored. Samples of suspended particulateswere collected inside and outside themuseuminwinterand summer2006.On days with intensive tourist visits the concentration of total suspended particulates was significantly higher (i.e., 130 µg/m3 inwinter and 49 µg/m3 in summer) than on those days without tourists (i.e., 73 µg/m3 and 22 µg/m3 in winter and summer, respectively). The concentrations of all investigated elementswere also considerably higher during the tourist flow. This was especially valid for soil dust associated elements (Si, K, Ca, Al, and Ti), with considerably higher levels in summer than winter. This could be linked with much more frequent tourist activity in the summer period. Also, the concentration of Clwasmuch higher inwinter than summer, due to the use of deicing salts on the roads and pavements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2008.04.005
|
|
|
“Complementary analysis of historical glass by scanning electron microscopy with energy dispersive X-ray spectroscopy and laser ablation inductiveley coupled plasma mass spectrometry”. Wagner B, Nowak A, Bulska E, Kunicki-Goldfinger J, Schalm O, Janssens K, schalm, Microchimica acta 162, 415 (2008). http://doi.org/10.1007/S00604-007-0835-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 28
DOI: 10.1007/S00604-007-0835-7
|
|
|
“Application of EPMA and XRF for the investigation of particulate pollutants in the field of cultural heritage”. Kontozova-Deutsch V, Deutsch F, Godoi RHM, Spolnik Z, Wei W, Van Grieken R, Microchimica acta 161, 465 (2008). http://doi.org/10.1007/S00604-007-0917-6
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-007-0917-6
|
|
|
“Investigation of gaseous and particulate air pollutants at the Basilica Saint-Urbain in Troyes, related to the preservation of the medieval stained glass windows”. Kontozova-Deutsch V, Godoi RHM, Worobiec A, Spolnik Z, Krata A, Deutsch F, Van Grieken R, Microchimica acta 162, 425 (2008). http://doi.org/10.1007/S00604-007-0930-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S00604-007-0930-9
|
|
|
“Analiza pierwiastkowa zabytkowych obiektów szklanych”. Wagner B, Nowak A, Bulska E, Kunicki-Goldfinger J, Schalm O, Janssens K, Nauka i Zabytki , 71 (2008)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Removal of natural organic matter from water by using ion-exchange resins”. Kabsch-Korbutowicz M, Krupinska B, Przemysl chemiczny
T2 –, Scientific and Technical Conference on Water and Wastewater Basis for, Environmental Protection (School of Quality Water 2008), MAY 28-30, 2008, Kolobrzeg, POLAND 87, 473 (2008)
Abstract: Four aq. solns. contg. natural peat components and the water from Odra river were treated with 3 anion-exchange resins (2.5 to 15 cm(3) of resin per 1 dm(3) of the sample) for 5-60 min to remove the org. matter. The process efficiency was detd. by UV absorbance (254 nm) and colour intensity measurements. The treatment resulted in discoloration of the solns. A resin with weak alky, was the most efficient. The degree of removal increased with increasing the resin dose and contact time. The presence of inorg. anions in the soins. contributed to a decrease of process effectivity.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Infrared investigation of hard human teeth tissues exposed to various doses of ionizing radiation from the 1986 Chernobyl accident”. Darchuk LA, Zaverbna LV, Bebeshko VG, Worobiec A, Stefaniak EA, Van Grieken R, Spectroscopy 22, 105 (2008). http://doi.org/10.1155/2008/843612
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1155/2008/843612
|
|
|
“Efficient separation of acetate and formate by ion chromatography: application to air samples in a cultural heritage environment”. Kontozova-Deutsch V, Krata A, Deutsch F, Bencs L, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 75, 418 (2008). http://doi.org/10.1016/J.TALANTA.2007.11.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.11.025
|
|
|
“Variation in particulate PAHs levels and their relation with the transboundary movement of the air masses”. Ravindra K, Wauters E, Van Grieken R, The science of the total environment 396, 100 (2008). http://doi.org/10.1016/J.SCITOTENV.2008.02.018
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SCITOTENV.2008.02.018
|
|
|
“Assessment of aerosol particles within the Rubens' House Museum in Antwerp, Belgium”. Godoi RHM, Potgieter-Vermaak S, Godoi AFL, Stranger M, Van Grieken R, X-ray spectrometry 37, 298 (2008). http://doi.org/10.1002/XRS.1049
Abstract: The majority of researchers, conservators and curators recognise that atmospheric pollution is one of the major threats to works of art. In principle, all atmospheric particles, when deposited onto art objects can be considered harmful because of their potential in causing deterioration. Moreover, under certain conditions, particulate matter can induce and intensify surface damage, particularly because of its potential to serve as centre for moisture condensation and adsorbent of gaseous pollutants. To investigate the potential harm that these particles can cause, comprehensive characterisation of the particulate matter is necessary. Particulate matter was collected at the Rubens' House Museum in Antwerp, Belgium, where a unique exhibit of the paintings and living quarters of Peter Paul Rubens (1577-1640) are seen. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental and molecular compositions. They were analysed by electron probe micro-analysis, utilising facilities for low-Z element determination, and by energy-dispersive x-ray fluorescence, to investigate the elemental composition of individual particles and bulk samples, and by micro Raman spectrometry, to elucidate the molecular composition. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could contribute to the chemical reactions taking place on the surfaces of artefacts and which could potentially cause degradation of the objects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1049
|
|
|
“Editorial: Award for best XRS referee during 2007-2008”. Van Grieken R, X-ray spectrometry 37, 571 (2008). http://doi.org/10.1002/XRS.1107
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1107
|
|
|
Schalm O, Caen J, Janssens K (2007) Chemical composition of 19th century window glass originating from stianed glass windows located in Belgium. 169–178
Keywords: P2 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Combined use of μ-XRF and μ-XRD for characterization of radioactive particle clusters released during the Chernobyl reactor incident”. Jaroszewicz J, de Nolf W, Janssens K, Claussen-Kjerre L, Lind OC, Salbu B, Falkenberg G (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Combined use of μ-XRF and μ-XRD to determine the heterogeneity, the chemical and phase composition of Ti-B-C ceramics prepared by the pulse plasma sintering (PPS) method”. Jaroszewicz J, de Nolf W, Janssens K, Michalski A, Falkenberg G (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Confocal μ-XRF and μ-XAFS studies of fractured granite following a radiotracer migration experiment”. Denecke MA, Janssens K, Brendebach B, Falkenberg G, de Nolf W, Römer J (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Confocal μ-XRF and μ-XAFS studies on fractured granite following a radiotracer migration experiment”. Denecke MA, Janssens K, Brendebach B, Falkenberg G, Römer J, Simon R, Vekemans B, (2007)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Depth profiling of multilayered systems by means of confocal μ-XRF in the laboratory an at HASYLAB BL L: a comparison”. Alfeld M, Vekemans B, Janssens K, Falkenberg G, Broekaert JAC, Gao N, Gibson D (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of Zn distribution inside edible plants grown on a polluted soil amended with compost by XRF microtomography”. Terzano R, al Chami Z, Vekemans B, Janssens K, Miano T, Ruggiero P (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Pigment identification by scanning μ-XRF/μ-XRD”. de Nolf W, Vekemans B, Janssens K, van der Snickt G, Falkenberg G (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Study of the degradation on historical documents induced by iron gall ink by means of scanning μ-XRF/μ-XRD”. de Nolf W, Janssens K, Rouchon V, Falkenberg G (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|