toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Jain, R.; Rather, J.A. pdf  doi
openurl 
  Title Stripping voltammetry of tinidazole in solubilized system and biological fluids Type A1 Journal article
  Year (down) 2011 Publication Colloids and surfaces: A: physicochemical and engineering aspects Abbreviated Journal  
  Volume 378 Issue Pages 27-33  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The adsorptive voltammetric behaviour of tinidazole onto the HMDE was investigated and validated in solubilized system and biological fluids by CV, SWCAdSV and DPCAdSV. Addition of CTAB to the solution containing drug enhanced the peak current while anionic and non-ionic surfactants showed an opposite effect. The electrode process is irreversible and adsorption controlled. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for tinidazole determination. Under optimized conditions; the adsorptive stripping peak current is linear over the concentration range 7.0 × 10−9 to 6.2 × 10−7 mol/L with detection limit of 4.5 × 10−10 mol/L. The precision of the proposed method in terms of RSD is 1.2% and mean recovery of 100.01%. The applicability of proposed method is further extended to in vitro determination of the drug in biological fluids.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000289544600004 Publication Date 2011-02-02  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0927-7757 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:98688 Serial 8584  
Permanent link to this record
 

 
Author Jain, R.; Rather, J.A. pdf  doi
openurl 
  Title Voltammetric determination of antibacterial drug gemifloxacin in solubilized systems at multi-walled carbon nanotubes modified glassy carbon electrode Type A1 Journal article
  Year (down) 2011 Publication Colloids and surfaces: B : biointerfaces Abbreviated Journal  
  Volume 83 Issue 2 Pages 340-346  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A sensitive electroanalytical method for determination of gemifloxacin in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at multi-walled carbon nanotubes modified glassy carbon electrode in the presence of CTAB. Solubilized system of different surfactants including SDS, Tween-20 and CTAB were taken for the study of electrochemical behaviour of gemifloxacin at modified electrode. The reduction peak current increases in the presence of CTAB while other surfactants show opposite effect. The modified electrode exhibits catalytic activity, high sensitivity, stability and is applicable over wide range of concentration for the determination of gemifloxacin. The mechanism of electrochemical reduction of gemifloxacin has been proposed on the basis of CV, SWV, DPV and coulometeric techniques. The proposed squarewave voltammetric method shows linearity over the concentration range 2.4715.5 μg/mL. The achieved limits of detection (LOD) and quantification (LOQ) are 0.90 ng/mL and 3.0 ng/mL respectively.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000287268000020 Publication Date 2010-12-08  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0927-7765 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:98687 Serial 8744  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: