|   | 
Details
   web
Records
Author Gijbels, R.; van Grieken, R.; Blommaert, W.; Van 't dack, L.; van Espen, P.; Nullens, H.; Saelens, R.
Title Application of analytical methods for trace elements in geothermal waters : part 2 : Plombières, Bains-les-Bains, Bourbonne (Vosges) Type MA3 Book as author
Year (down) 1983 Publication Abbreviated Journal
Volume Issue Pages
Keywords MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication S.l. Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:117472 Serial 140
Permanent link to this record
 

 
Author Vandelannoote, R.; Blommaert, W.; Gijbels, R.; van Grieken, R.
Title Analysis of geothermal waters by spark source mass spectrometry Type A3 Journal article
Year (down) 1981 Publication Fresenius' Zeitschrift für analytische Chemie Abbreviated Journal
Volume 309 Issue 4 Pages 291-294
Keywords A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Although the analysis of thermal water by spark-source mass spectrometry (SSMS) is rather timeconsuming, it allows the detection of about 20 elements of geochemical interest down to the ppb-level. A physical preconcentration is proposed in order to collect elements having quite different chemical properties, e.g. alkalis, transition elements, and elements occurring in anionic form. The relative sensitivity factors appear to be rather independent of the salt content of the graphite electrodes. Contrary to neutron activation analysis, SSMS has a quite uniform elemental sensitivity, and allows to determine elements for which neutron activation is not suitable, e.g. Sn and Pb. The precision of SSMS is however by a factor of about 2 worse than that obtained for neutron activation.
Address
Corporate Author Thesis
Publisher Place of Publication München Editor
Language Wos Publication Date 2004-11-15
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0016-1152;1618-2650; ISBN Additional Links UA library record
Impact Factor Times cited 8 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116638 Serial 100
Permanent link to this record
 

 
Author Tavernier, S.M.F.; Nies, E.; Gijbels, R.
Title Hard-spere model for hydrodynamic chromatography systems Type A1 Journal article
Year (down) 1981 Publication Analytical proceedings Abbreviated Journal
Volume 18 Issue Pages 31-34
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication London Editor
Language Wos Publication Date 2004-03-18
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0144-557X; ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:110347 Serial 1409
Permanent link to this record
 

 
Author Gijbels, R.; van Grieken, R.; Vandelannoote, R.; Blommaert, W.; Van 't dack, L.
Title Trace element geochemistry in thermal waters from Amélie-les-Bains (Eastern Pyrenees, France) Type P3 Proceeding
Year (down) 1980 Publication Abbreviated Journal
Volume Issue Pages 123-126
Keywords P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication S.l. Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:111509 Serial 3690
Permanent link to this record
 

 
Author Gijbels, R.; van Grieken, R.; Blommaert, W.; Vandelannoote, R.; Van 't dack, L.
Title Trace element geochemistry in thermal waters from Plombières and Bains (Vosges) Type P3 Proceeding
Year (down) 1980 Publication Abbreviated Journal
Volume Issue Pages 396-409
Keywords P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Reidel Place of Publication Dordrecht Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:111508 Serial 3691
Permanent link to this record
 

 
Author Blommaert, W.; Vandelannoote, R.; Van 't dack, L.; Gijbels, R.; van Grieken, R.
Title Relative evaluation of neutron activation, X-ray fluorescence and spark source mass spectrometry for multi-element analysis of geothermal waters Type A3 Journal article
Year (down) 1980 Publication Journal of radioanalytical chemistry Abbreviated Journal
Volume 57 Issue Pages 382-400
Keywords A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0134-0719 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved
Call Number UA @ lucian @ c:irua:111432 Serial 2859
Permanent link to this record
 

 
Author Vandelannoote, R.; Blommaert, W.; van Grieken, R.; Gijbels, R.
Title L'analyse des eaux géothermales par spectrométrie de masse à étincelles Type A3 Journal article
Year (down) 1979 Publication Spectra 2000: la revue de l'instrumentation Abbreviated Journal
Volume 53 Issue Pages 66
Keywords A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Paris Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0399-1172 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116645 Serial 98
Permanent link to this record
 

 
Author van Grieken, R.; Gijbels, R.; Blommaert, W.; Vandelannoote, R.; Van 't dack, L.
Title Geothermal water analysis by X-ray fluorescence and neutron activation Type H3 Book chapter
Year (down) 1978 Publication Abbreviated Journal
Volume Issue Pages 368-378
Keywords H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher US Energy Research and Development Administration Place of Publication S.l. Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved PHYSICS, APPLIED 47/145 Q2 #
Call Number UA @ lucian @ c:irua:117464 Serial 1335
Permanent link to this record
 

 
Author Gijbels, R.; van Grieken, R.; Blommaert, W.; Vandelannoote, R.; Van 't dack, L.
Title Application of trace element analysis to geothermal waters Type P3 Proceeding
Year (down) 1977 Publication Abbreviated Journal
Volume Issue Pages 429-439
Keywords P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Directorate General for Research, Science and Education Place of Publication Brussels Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:117462 Serial 143
Permanent link to this record
 

 
Author Gijbels, R.; van Grieken, R.
Title Application of analytical methods for trace elements in geothermal waters : part 1 : Amélie-les-Bains (Eastern Pyrenees) Type MA3 Book as author
Year (down) 1977 Publication Abbreviated Journal
Volume Issue Pages
Keywords MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication S.l. Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:117471 Serial 139
Permanent link to this record
 

 
Author Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A.
Title Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects Type A1 Journal article
Year (down) 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 64 Issue 2 Pages 187-196
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1973P353000003 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 11 Open Access
Notes Approved CHEMISTRY, PHYSICAL 54/144 Q2 # PHYSICS, ATOMIC, MOLECULAR & CHEMICAL 9/35 Q2 #
Call Number UA @ lucian @ c:irua:116363 Serial 3464
Permanent link to this record
 

 
Author Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A.
Title Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen Type A1 Journal article
Year (down) 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 65 Issue 1 Pages 1-17
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1973Q019300001 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 12 Open Access
Notes Approved
Call Number UA @ lucian @ c:irua:116364 Serial 3465
Permanent link to this record
 

 
Author Gijbels, R.; Dams, R.
Title Determination of silicon in natural and pollution aerosols by 14-MeV neutron activation analysis Type A1 Journal article
Year (down) 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 63 Issue 2 Pages 369-381
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Abstract The determination of silicon via the 28Si(n,p)28 Al reaction by means of 14-MeV neutrons is applied to the analysis of pollution and natural aerosols. A Whatman 41 filter (40 cm2) on which airborne particulate material has been collected is compressed into a 3 × 12.7 mm pellet. Standards are prepared in the same way from clean filters spiked with a silicate solution. After a 50-s irradiation and a 75-s decay time, the sample is counted for 2 min with 5 × 5 NaI(Tl) well detector. The 1.779-MeV photopeak of 28Al is measured with a single channel sealer chain or with a multichannel analyser. The reproducibility, sensitivity and liability to interference from other elements were investigated for both counting systems. The homogeneity of the pellets and the filters was checked. The overall precision of one single-channel determination was estimated to be 3.5% after a 24-h high-volume sampling time. Samples collected in urban, industrial and remote areas with concentrations ranging from 0.05 to 15 μg Si m-3 air were analysed and the results are discussed.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1973O944700013 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 16 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116365 Serial 672
Permanent link to this record
 

 
Author van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J.
Title Determination of oxygen, silicon, phosphorus and copper in iron and steel by 14 MeV neutron activation analysis Type MA3 Book as author
Year (down) 1971 Publication Abbreviated Journal
Volume Issue Pages
Keywords MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication S.l. Editor
Language Wos Publication Date 0000-00-00
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:117466 Serial 669
Permanent link to this record
 

 
Author van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J.
Title The determination of silicon in steel by 14-mev neutron activation analysis Type A1 Journal article
Year (down) 1968 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 43 Issue Pages 199-209
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1968C007600004 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 19 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116357 Serial 673
Permanent link to this record
 

 
Author van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J.
Title Internal standard activation analysis of silicon in steel Type A1 Journal article
Year (down) 1968 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 43 Issue Pages 381-395
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1968C185100003 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 14 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116358 Serial 1701
Permanent link to this record